RESUMEN
PURPOSE: The study aimed to investigate the pattern of failure and describe compromises in the definition and coverage of the target for patients treated with curatively intended radiotherapy (RT) for sinonasal cancer (SNC). METHODS AND MATERIAL: Patients treated with curatively intended RT in 2008-2015 in Denmark for SNC were eligible for the retrospective cohort study. Information regarding diagnosis and treatment was retrieved from the national database of the Danish Head and Neck Cancer Group (DAHANCA). Imaging from the diagnosis of recurrences was collected, and the point of origin (PO) of the recurrent tumour was estimated. All treatment plans were collected and reviewed with the focus on target coverage, manual modifications of target volumes, and dose to organs at risk (OARs) above defined constraints. RESULTS: A total of 184 patients were included in the analysis, and 76 (41%) relapsed. The majority of recurrences involved T-site (76%). Recurrence imaging of 39 patients was evaluated, and PO was established. Twenty-nine POs (74%) were located within the CTV, and the minimum dose to the PO was median 64.1 Gy (3.1-70.7). The criteria for target coverage (V95%) was not met in 89/184 (48%) of the CTV and 131/184 (71%) of the PTV. A total of 24% of CTVs had been manually modified to spare OARs of high-dose irradiation. No difference in target volume modifications was observed between patients who suffered recurrence and patients with lasting remission. CONCLUSION: The majority of relapses after radical treatment of SNC were located in the T-site (the primary tumour site). Multiple compromises with regards to target coverage and tolerance levels for OARs in the sinonasal region, as defined from RT guidelines, were taken. No common practice in this respect could be derived from the study.
Asunto(s)
Neoplasias de los Senos Paranasales , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Dinamarca/epidemiología , Humanos , Recurrencia Local de Neoplasia/epidemiología , Recurrencia Local de Neoplasia/radioterapia , Neoplasias de los Senos Paranasales/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios RetrospectivosRESUMEN
BACKGROUND: Deformable image registrations are prone to errors in aligning reliable anatomically features. Consequently, identification of registration inaccuracies is important. Particularly thoracic three-dimensional (3D) computed tomography (CT)-CT image registration is challenging due to lack of contrast in lung tissue. This study aims for validation of thoracic CT-CT image registration using auto-segmented anatomically landmarks. MATERIAL AND METHODS: Five lymphoma patients were CT scanned three times within a period of 18 months, with the initial CT defined as the reference scan. For each patient the two successive CT scans were registered to the reference CT using three different image registration algorithms (Demons, B-spline and Affine). The image registrations were evaluated using auto-segmented anatomical landmarks (bronchial branch points) and Dice Similarity Coefficients (DSC). Deviation of corresponding bronchial landmarks were used to quantify inaccuracies in respect of both misalignment and geometric location within lungs. RESULTS: The median bronchial branch point deviations were 1.6, 1.1 and 4.2 (mm) for the three tested algorithms (Demons, B-spline and Affine). The maximum deviations (> 15 mm) were found within both Demons and B-spline image registrations. In the upper part of the lungs the median deviation of 1.7 (mm) was significantly different (p < 0.02) relative to the median deviations of 2.0 (mm), found in the middle and lower parts of the lungs. The DSC revealed similar registration discrepancies among the three tested algorithms, with DSC values of 0.96, 0.97 and 0.91, for respectively Demons, B-spline and the Affine algorithms. CONCLUSION: Bronchial branch points were found useful to validate thoracic CT-CT image registration. Bronchial branch points identified local registration errors > 15 mm in both Demons and B-spline deformable algorithms.
Asunto(s)
Puntos Anatómicos de Referencia/diagnóstico por imagen , Imagenología Tridimensional , Pulmón/diagnóstico por imagen , Algoritmos , Humanos , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos XRESUMEN
BACKGROUND: Fiducials can be used as surrogate for target position during radiotherapy. However, fiducial motion could lead to potential position errors when using fiducials in four-dimensional computed tomography (4DCT) treatment planning and for gated image guided radiotherapy (IGRT). MATERIAL AND METHODS: One gold marker (GM) and 5, 10 and 15 mm nickel-titanium (NiTi) stents were inserted in a moving phantom for the purpose of fiducial detection in 4DCT and gated IGRT. Fiducial position errors in 4DCT and BrainLAB's gated IGRT were defined as residuals between fiducial detection and the actual physical position at the instance of image acquisition. RESULTS: Fiducials position errors correlate to speed, fiducial type and orientation during 4DCT acquisition. Lower detection accuracy was measured for the 5 mm NiTi-stent relative to the 10 and 15 mm NiTi stents and GM. Fiducials with orientation 45° relative to the scan direction showed a lower detection accuracy relative to parallel and perpendicular orientations. The standard deviation of position errors in 4DCT were up to 2.2 mm with a maximum deviation of 4.0 mm. Using BrainLAB's gated IGRT the fiducials were detected with a standard deviation of 0.6 mm and a maximum deviation of 1.9 mm. For gated IGRT no correlation to fiducial speed was found. CONCLUSIONS: Clinical use of fiducials in combination with treatment planning on mid-ventilation CT phase for moving target should include margins up to 5.5 mm due to potential systematic position errors.
Asunto(s)
Marcadores Fiduciales , Tomografía Computarizada Cuatridimensional , Posicionamiento del Paciente , Errores de Configuración en Radioterapia , Radioterapia Guiada por Imagen , Neoplasias Torácicas/diagnóstico por imagen , Neoplasias Torácicas/radioterapia , Humanos , Movimiento , Níquel , Fantasmas de Imagen , Respiración , Stents , TitanioRESUMEN
PURPOSE: To investigate the accuracy and potential limitations of MV image-based dynamic multileaf collimator (DMLC) tracking in a porcine model on a linear accelerator. METHODS AND MATERIALS: A thermo-expandable NiTi stent designed for kilovoltage (kV) X-ray visualization of lung lesions was inserted into the bronchia of three anaesthetized Göttingen minipigs. A four-dimensional computed tomography scan was used for planning a five-field conformal treatment with circular multileaf collimator (MLC) apertures. A 22.5 Gy single fraction treatment was delivered to the pigs. The peak-to-peak stent motion was 3 to 8 mm, with breathing periods of 1.2 to 4 s. Before treatment, X-ray images were used for image-guided setup based on the stent. During treatment delivery, continuous megavoltage (MV) portal images were acquired at 7.5 Hz. The stent was segmented in the images and used for continuous adaptation of the MLC aperture. Offline, the tracking error in beam's eye view of the treatment beam was calculated for each MV image as the difference between the MLC aperture center and the segmented stent position. The standard deviations of the systematic error Σ and the random error σ were determined and compared with the would-be errors for a nontracking treatment with pretreatment image-guided setup. RESULTS: Reliable stent segmentation was obtained for 11 of 15 fields. Segmentation failures occurred when image contrast was dominated by overlapping anatomical structures (ribs, diaphragm) rather than by the stent, which was designed for kV rather than MV X-ray visibility. For the 11 fields with reliable segmentation, Σ was 0.5 mm/0.4 mm in the two imager directions, whereas σ was 0.5 mm/1.1 mm. Without tracking, Σ and σ would have been 1.7 mm/1.4 mm and 0.8 mm/1.4 mm, respectively. CONCLUSION: For the first time, in vivo DMLC tracking has been demonstrated on a linear accelerator showing the potential for improved targeting accuracy. The study mimicked the envisioned patient workflow of future patient treatments. Clinical implementation of MV image-based tracking would require markers designed for MV visibility.