Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
ACS Sens ; 9(7): 3660-3670, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38968930

RESUMEN

DNA-based tension sensors have innovated the imaging and calibration of mechanosensitive receptor-transmitted molecular forces, such as integrin tensions. However, these sensors mainly serve as binary reporters, only indicating if molecular forces exceed one predefined threshold. Here, we have developed tandem tension sensor (TTS), which comprises two consecutive force-sensing units, each with unique force detection thresholds and distinct fluorescence spectra, thereby enabling the quantification of molecular forces with dual reference levels. With TTS, we revealed that vinculin is not required for transmitting integrin tensions at approximately 10 pN (piconewtons) but is essential for elevating integrin tensions beyond 20 pN in focal adhesions (FAs). Such high tensions have emerged during the early stage of FA formation. TTS also successfully detected changes in integrin tensions in response to disrupted actin formation, inhibited myosin activity, and tuned substrate elasticity. We also applied TTS to examine integrin tensions in platelets and revealed two force regimes, with integrin tensions surpassing 20 pN at cell central regions and 13-20 pN integrin tensions at the cell edge. Overall, TTS, especially the construct consisting of a hairpin DNA (13 pN opening force) and a shearing DNA (20 pN opening force), stands as a valuable tool for the quantification of receptor-transmitted molecular forces within living cells.


Asunto(s)
Integrinas , Integrinas/metabolismo , Humanos , Vinculina/metabolismo , Adhesiones Focales , Técnicas Biosensibles/métodos , Animales , ADN/química , Plaquetas/citología , Plaquetas/metabolismo
2.
J Mater Chem B ; 12(2): 286-331, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-37955235

RESUMEN

The Curie temperature is an important thermo-characteristic of magnetic materials, which causes a phase transition from ferromagnetic to paramagnetic by changing the spontaneous re-arrangement of their spins (intrinsic magnetic mechanism) due to an increase in temperature. The self-control-temperature (SCT) leads to the conversion of ferro/ferrimagnetic materials to paramagnetic materials, which can extend the temperature-based applications of these materials from industrial nanotechnology to the biomedical field. In this case, magnetic induction hyperthermia (MIH) with self-control-temperature has been proposed as a physical thermo-therapeutic method for killing cancer tumors in a biologically safe environment. Specifically, the thermal source of MIH is magnetic nanoparticles (MNPs), and thus their biocompatibility and Curie temperature are two important properties, where the former is required for their clinical application, while the latter acts as a switch to automatically control the temperature of MIH. In this review, we focus on the Curie temperature of magnetic materials and provide a complete overview beginning with basic magnetism and its inevitable relation with Curie's law, theoretical prediction and experimental measurement of the Curie temperature. Furthermore, we discuss the significance, evolution from different types of alloys to ferrites and impact of the shape, size, and concentration of particles on the Curie temperature considering the proposed SCT-based MIH together with their biocompatibility. Also, we highlight the thermal efficiency of MNPs in destroying tumor cells and the significance of a low Curie temperature. Finally, the challenges, concluding remarks, and future perspectives in promoting self-control-temperature based MIH to clinical application are discussed.


Asunto(s)
Hipertermia Inducida , Neoplasias , Humanos , Temperatura , Hipertermia Inducida/métodos , Magnetismo , Imanes , Hipertermia
3.
ACS Sens ; 8(10): 3701-3712, 2023 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-37738233

RESUMEN

Integrin tensions are critical for cell mechanotransduction. By converting force to fluorescence, molecular tension sensors image integrin tensions in live cells with a high resolution. However, the fluorescence signal intensity results collectively from integrin tension magnitude, tension dwell time, integrin density, sensor accessibility, and so forth, making it highly challenging to specifically monitor the molecular force level of integrin tensions. Here, a ratiometric tension sensor (RTS) was developed to exclusively monitor the integrin tension magnitude. The RTS consists of two tension-sensing units that are coupled in series and always subject to the same integrin tension. These two units are activated by tension to fluoresce in separate spectra and with different activation rates. The ratio of their activation probabilities, reported by fluorescence ratiometric measurement, is solely determined by the local integrin tension magnitude. RTS responded sensitively to the variation of integrin tension magnitude in platelets and focal adhesions due to different cell plating times, actomyosin inhibition, or vinculin knockout. At last, RTS confirmed that integrin tension magnitude in platelets and focal adhesions decreases monotonically with the substrate rigidity, verifying the rigidity dependence of integrin tensions in live cells and suggesting that integrin tension magnitude could be a key biomechanical factor in cell rigidity sensing.


Asunto(s)
Integrinas , Mecanotransducción Celular , Integrinas/análisis , Integrinas/metabolismo , Adhesiones Focales/metabolismo , Fenómenos Mecánicos , Citoesqueleto de Actina/metabolismo
4.
Nanoscale Adv ; 5(18): 5015-5028, 2023 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-37705767

RESUMEN

Theoretical and micromagnetic simulation studies of magnetic nanospheres with vortex configurations suggest that such nanostructured materials have technological advantages over conventional nanosystems for applications based on high-power-rate absorption and subsequent emission. However, full experimental evidence of magnetic vortex configurations in spheres of submicrometer size is still lacking. Here, we report the microwave irradiation fabrication of Fe3O4 nanospheres and establish their magnetic vortex configuration based on experimental results, theoretical analysis, and micromagnetic simulations. Detailed magnetic and electrical measurements, together with Mössbauer spectroscopy data, provide evidence of a loss of stoichiometry in vortex nanospheres owing to the presence of a surface oxide layer, defects, and a higher concentration of cation vacancies. The results indicate that the magnetic vortex spin configuration can be established in bulk spherical magnetite materials. This study provides crucial information that can aid the synthesis of magnetic nanospheres with magnetically tailored properties; consequently, they may be promising candidates for future technological applications based on three-dimensional magnetic vortex structures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA