Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ultraschall Med ; 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38537666

RESUMEN

PURPOSE: The use of tissue adhesive instead of a drain following mastectomy was a point of interest for many breast surgeons. Postoperative formation of multiple unusual sonographic lesions was observed in patients that underwent mastectomy with TissuGlu. The aim of this study was to describe the sonographic features of these lesions and, when possible, to examine them histologically. MATERIALS AND METHODS: This study includes 98 patients, 49 underwent mastectomy with the application of TissuGlu and 49 with drain insertion. Unusual postoperative sonographic findings were thoroughly described. A histological examination was carried out according to the guideline recommendations. RESULTS: Unusual sonographic findings were detected in 87.8% of patients in the TissuGlu group and in only 4% of the patients in the drain group. These lesions were detectable between 6 and 59 months postoperatively. 47 breasts of the TissuGlu group were classified as category 3, while only 2 breasts as category 4. Lesions were on average 7.5 mm in diameter, echogenic or isoechoic with posterior shadowing, an irregular and ill circumscribed marginal contour, and a horizontal axis. All histologically examined lesions (n=29) were benign. Granulomatous tissue was histologically proven in 63% of those lesions (n=17), while residual adhesive material could be detected in 18.5% of lesions (n=5). CONCLUSION: The use of TissuGlu adhesive after mastectomy may cause the formation of unusual palpable granulomas, with or without residual adhesive materials. Sonographic description of lesions will help physicians to differentiate between granulomas and local relapse.

2.
J Ultrasound Med ; 42(8): 1729-1736, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36789976

RESUMEN

OBJECTIVES: We evaluated whether lesion-to-fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI-RADS) 3 or 4 lesions has the potential to further refine the assessment of B-mode ultrasound alone in breast cancer diagnostics. METHODS: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI-RADS 3 and 4a-c by conventional B-mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI-RADS 3 and BI-RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion-to-fat ratio measured by shear wave elastography were evaluated. RESULTS: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B-mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI-RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI-RADS 3. Additional lesion-to-fat ratio in BI-RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. CONCLUSIONS: Adding lesion-to-fat ratio measured by shear wave elastography to conventional B-mode ultrasound in BI-RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI-RADS 3 definition of <2% of undetected malignancies.


Asunto(s)
Neoplasias de la Mama , Diagnóstico por Imagen de Elasticidad , Humanos , Femenino , Sensibilidad y Especificidad , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía Mamaria/métodos , Reproducibilidad de los Resultados , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Biopsia , Elasticidad , Diagnóstico Diferencial
3.
Ultraschall Med ; 44(2): 162-168, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34425600

RESUMEN

PURPOSE: In this prospective, multicenter trial we evaluated whether additional shear wave elastography (SWE) for patients with BI-RADS 3 or 4 lesions on breast ultrasound could further refine the assessment with B-mode breast ultrasound for breast cancer diagnosis. MATERIALS AND METHODS: We analyzed prospective, multicenter, international data from 1288 women with breast lesions rated by conventional 2 D B-mode ultrasound as BI-RADS 3 to 4c and undergoing 2D-SWE. After reclassification with SWE the proportion of undetected malignancies should be < 2 %. All patients underwent histopathologic evaluation (reference standard). RESULTS: Histopathologic evaluation showed malignancy in 368 of 1288 lesions (28.6 %). The assessment with B-mode breast ultrasound resulted in 1.39 % (6 of 431) undetected malignancies (malignant lesions in BI-RADS 3) and 53.80 % (495 of 920) unnecessary biopsies (biopsies in benign lesions). Re-classifying BI-RADS 4a patients with a SWE cutoff of 2.55 m/s resulted in 1.98 % (11 of 556) undetected malignancies and a reduction of 24.24 % (375 vs. 495) of unnecessary biopsies. CONCLUSION: A SWE value below 2.55 m/s for BI-RADS 4a lesions could be used to downstage these lesions to follow-up, and therefore reduce the number of unnecessary biopsies by 24.24 %. However, this would come at the expense of some additionally missed cancers compared to B-mode breast ultrasound (rate of undetected malignancies 1.98 %, 11 of 556, versus 1.39 %, 6 of 431) which would, however, still be in line with the ACR BI-RADS 3 definition (< 2 % of undetected malignancies).


Asunto(s)
Neoplasias de la Mama , Diagnóstico por Imagen de Elasticidad , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Prospectivos , Sensibilidad y Especificidad , Diagnóstico Diferencial , Reproducibilidad de los Resultados , Ultrasonografía Mamaria/métodos , Biopsia
4.
Ultraschall Med ; 44(5): 520-536, 2023 Oct.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-37072031

RESUMEN

Alongside mammography, breast ultrasound is an important and well-established method in assessment of breast lesions. With the "Best Practice Guideline", the DEGUM Breast Ultrasound (in German, "Mammasonografie") working group, intends to describe the additional and optional application modalities for the diagnostic confirmation of breast findings and to express DEGUM recommendations in this Part II, in addition to the current dignity criteria and assessment categories published in Part I, in order to facilitate the differential diagnosis of ambiguous lesions.The present "Best Practice Guideline" has set itself the goal of meeting the requirements for quality assurance and ensuring quality-controlled performance of breast ultrasound. The most important aspects of quality assurance are explained in this Part II of the Best Practice Guideline.


Asunto(s)
Mamografía , Ultrasonografía Mamaria , Femenino , Humanos , Mamografía/métodos
5.
Eur Radiol ; 32(6): 4101-4115, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35175381

RESUMEN

OBJECTIVES: AI-based algorithms for medical image analysis showed comparable performance to human image readers. However, in practice, diagnoses are made using multiple imaging modalities alongside other data sources. We determined the importance of this multi-modal information and compared the diagnostic performance of routine breast cancer diagnosis to breast ultrasound interpretations by humans or AI-based algorithms. METHODS: Patients were recruited as part of a multicenter trial (NCT02638935). The trial enrolled 1288 women undergoing routine breast cancer diagnosis (multi-modal imaging, demographic, and clinical information). Three physicians specialized in ultrasound diagnosis performed a second read of all ultrasound images. We used data from 11 of 12 study sites to develop two machine learning (ML) algorithms using unimodal information (ultrasound features generated by the ultrasound experts) to classify breast masses which were validated on the remaining study site. The same ML algorithms were subsequently developed and validated on multi-modal information (clinical and demographic information plus ultrasound features). We assessed performance using area under the curve (AUC). RESULTS: Of 1288 breast masses, 368 (28.6%) were histopathologically malignant. In the external validation set (n = 373), the performance of the two unimodal ultrasound ML algorithms (AUC 0.83 and 0.82) was commensurate with performance of the human ultrasound experts (AUC 0.82 to 0.84; p for all comparisons > 0.05). The multi-modal ultrasound ML algorithms performed significantly better (AUC 0.90 and 0.89) but were statistically inferior to routine breast cancer diagnosis (AUC 0.95, p for all comparisons ≤ 0.05). CONCLUSIONS: The performance of humans and AI-based algorithms improves with multi-modal information. KEY POINTS: • The performance of humans and AI-based algorithms improves with multi-modal information. • Multimodal AI-based algorithms do not necessarily outperform expert humans. • Unimodal AI-based algorithms do not represent optimal performance to classify breast masses.


Asunto(s)
Inteligencia Artificial , Neoplasias de la Mama , Algoritmos , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Humanos , Imagen Multimodal
6.
Ultraschall Med ; 43(6): 570-582, 2022 Dec.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-34921376

RESUMEN

For many years, breast ultrasound has been used in addition to mammography as an important method for clarifying breast findings. However, differences in the interpretation of findings continue to be problematic 1 2. These differences decrease the diagnostic accuracy of ultrasound after detection of a finding and complicate interdisciplinary communication and the comparison of scientific studies 3. In 1999, the American College of Radiology (ACR) created a working group (International Expert Working Group) that developed a classification system for ultrasound examinations based on the established BI-RADS classification of mammographic findings under consideration of literature data 4. Due to differences in content, the German Society for Ultrasound in Medicine (DEGUM) published its own BI-RADS-analogue criteria catalog in 2006 3. In addition to the persistence of differences in content, there is also an issue with formal licensing with the current 5th edition of the ACR BI-RADS catalog, even though the content is recognized by the DEGUM as another system for describing and documenting findings. The goal of the Best Practice Guideline of the Breast Ultrasound Working Group of the DEGUM is to provide colleagues specialized in senology with a current catalog of ultrasound criteria and assessment categories as well as best practice recommendations for the various ultrasound modalities.


Asunto(s)
Neoplasias de la Mama , Medicina , Femenino , Humanos , Ultrasonografía Mamaria/métodos , Mamografía/métodos , Neoplasias de la Mama/diagnóstico por imagen
7.
Ultraschall Med ; 40(2): 212-220, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30125909

RESUMEN

PURPOSE: The aim of the present study was to determine the accuracy of breast cancer measurement with 2 D shear wave elastography (2 D SWE), B-mode ultrasound, and mammography by comparing these methods with the actual histopathological tumor size. MATERIALS AND METHODS: 135 patients with proven malignant breast lesions at two centers were included in a prospective study. The maximum lesion diameter was measured by 2 D SWE, B-mode ultrasound, and mammography. After surgery, the histopathological tumor size was measured by a pathologist. RESULTS: The mean difference in tumor size on 2 D SWE, B-mode ultrasound, and mammography on the one hand, and the actual tumor size on the other, was -0.03 cm, 0.16 cm and 0.10 cm, respectively. Lesion size on histopathological investigation was overestimated by 2 D SWE (p = 0.004) and underestimated by B-mode imaging (p < 0.001). All three imaging methods underestimated the size of invasive lobular cancers and lesions > 15 mm; 2 D SWE was most accurate in this regard. CONCLUSION: 2 D SWE predicted lesion size more precisely than B-mode ultrasound or mammography. In cases of invasive lobular carcinoma, all three imaging methods underestimated lesion size, with 2 D SWE coming closest to the actual tumor size.


Asunto(s)
Neoplasias de la Mama , Diagnóstico por Imagen de Elasticidad , Ultrasonografía Mamaria , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Mamografía , Estudios Prospectivos
8.
Arch Gynecol Obstet ; 298(4): 755-761, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30083777

RESUMEN

OBJECTIVE: Synthetic meshes and acellular dermal matrices are increasingly used in implant-based breast reconstruction. The objective of this study was to determine the incidence and severity of complications following the implantation of the partially absorbable bi-component soft mesh SERAGYN® BR and assess risk factors for adverse operative outcomes. METHODS: A retrospective clinical study was performed: The SERAGYN® BR soft mesh was utilized in 148 operations (skin-sparing mastectomy, nipple-sparing mastectomy, breast-conserving surgery, and secondary reconstruction after mastectomy) in four different institutions in Germany from June 2012 to February 2014. We analyzed whether the results were affected by tumor morphology (e.g., grading), patient characteristics and comorbidities, previous surgery or therapies, and use of alloplastic materials. RESULTS: The SERAGYN® BR soft mesh was successfully implanted in 131 of 148 operations. The rate of reconstructive failure was 11.5%. The most common complication was seroma (25.7%), followed by hematoma and skin infection (each 14.2%). Wound-healing issues were detected in 13.5% cases, secondary wound infections in 10.8%. 83.8% of operations had no severe complications. Independent predictors for reconstructive failure were wound-healing issues, nipple- or skin necrosis, wound- or skin infections, a high volume of excised tissue, hematomas, seromas, and sentinel lymph node excisions. A higher body mass index was correlated with a higher rate of infection. CONCLUSION: SERAGYN® BR mesh can be used successfully in breast reconstructive surgery. Rates of major complications or reconstructive failure are comparable to the use of other synthetic or biological meshes.


Asunto(s)
Implantación de Mama/métodos , Neoplasias de la Mama/cirugía , Mallas Quirúrgicas , Adolescente , Adulto , Anciano , Implantación de Mama/efectos adversos , Femenino , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Seroma/epidemiología , Cicatrización de Heridas , Adulto Joven
9.
Arch Gynecol Obstet ; 290(4): 697-704, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24781718

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the safety and efficacy of SprayShield™ Adhesion Barrier in preventing and/or reducing postoperative adhesion during gynecological surgery. DESIGN: This was a prospective, controlled, blinded, and randomized study. Patient blinding was performed intraoperatively. Subjects were randomly assigned to the SprayShield™ or the control group in a 2:1 ratio. SETTING: The study was conducted at the Clinic of Gynaecology and Obstetrics, at the University Hospital for Gynecology in Germany. PATIENTS: Fifteen patients participated in this study; nine patients were assigned to the SprayShield™ and six patients to the control group. INTERVENTIONS: During first operation (FLL) in the SprayShield™ group, the agent was applied to all myomectomy suture lines. Patients in the control group did not receive any anti-adhesion treatment, only good surgical practice. A second-look laparoscopy (SLL) was performed 8-12 weeks after myomectomy to evaluate adhesion formation. MAIN OUTCOME MEASURES: Main outcome measures were incidence, severity, and extent of uterine adhesions. RESULTS: No significant differences were found between the two study groups. CONCLUSIONS: SprayShield™ is easy to use. No serious adverse event related to SprayShield™ was observed. Efficacy data are inconclusive regarding the performance of SprayShield™. Further studies are needed to better understand this performance.


Asunto(s)
Vendas Hidrocoloidales , Laparoscopía , Miomectomía Uterina/métodos , Implantes Absorbibles , Adulto , Femenino , Humanos , Estudios Prospectivos , Segunda Cirugía , Método Simple Ciego , Adherencias Tisulares/prevención & control
10.
Radiology ; 266(1): 72-80, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23023963

RESUMEN

PURPOSE: To study T1 baseline signal intensity (SI) and contrast material enhancement kinetics of normal breast parenchyma by using dynamic contrast-enhanced (DCE) magnetic resonance (MR) mammography and to determine the influence of anthropometric measures and menopausal status on the variability of these features. MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained. Between June 2008 and September 2011, 345 women (age range, 26-81 years; mean age, 51.3 years ± 11.6 [standard deviation]) underwent DCE MR mammography, with T1-weighted three-dimensional MR images (repetition time msec/echo time msec, 8.86/4.51; flip angle, 25°) acquired with a 1.5-T whole-body MR unit before and 1, 2, 3, 4, and 5 minutes after a gadobutrol bolus injection of 0.1 mmol per kilogram of body weight. Regions of interest were traced manually, and T1 SI of parenchyma was recorded. The influence of different predictors of T1 baseline SI and contrast enhancement was studied by using random-effects models. RESULTS: T1 baseline SI varied considerably between women, with a mean of 167.7 ± 49.2 (71.4-424.7 [range]) and 175.9 ± 48.9 (51.8-458.3) in the right and the left breast, respectively (P < .01). T1 baseline SI increased linearly with age (P < .0001) and body weight (P < .0001). After contrast material delivery, relative percentage of enhancement was 8.1%, 13.8%, 18.2%, 22.1%, and 24.6% at 1, 2, 3, 4, and 5 minutes, respectively, but varied considerably between women. Contrast enhancement was 9.3% in the lowest quintile and 47.4% in the highest. Contrast enhancement increased with body weight (P < .01) but decreased in postmenopausal women (P < .01). Women with higher baseline T1 SI tended to have a higher contrast enhancement slope. CONCLUSION: Anthropometric measures and menopausal status contribute to a large variability in contrast enhancement of normal breast parenchyma. This might influence the interpretation of contrast enhancement kinetics of breast lesions and current strategies for determining contrast medium dose for breast MR imaging.


Asunto(s)
Peso Corporal/fisiología , Mama/anatomía & histología , Mama/fisiología , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Compuestos Organometálicos/farmacocinética , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento/metabolismo , Envejecimiento/patología , Medios de Contraste/farmacocinética , Femenino , Humanos , Menopausia , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Onkologie ; 36(1-2): 12-6, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23429326

RESUMEN

BACKGROUND: This study aims to assess the role of ductoscopy for detecting intraductal anomalies in patients with nipple discharge in comparison to conventional tests and to find an effective combination of both approaches. MATERIALS AND METHODS: Prior to duct excision, ductoscopy was performed in 97 women. Histologic and all other diagnostic results were compared. Sensitivity, specificity, and efficiency were calculated for all methods. These parameters were also calculated for all possible test combinations in 12 patients who had completed all tests. RESULTS: Breast sonography reached the highest sensitivity (64.1%) and efficiency (64%); mammography had the highest specificity (100%). The sensitivity of ductoscopy was 53.2%, its specificity 60%, and its efficiency 55.1%. Among combinations of all methods, the combination ductoscopy + galactography was the most sensitive (80%). Mammography, magnetic resonance imaging, and ductoscopy were each 100% specific. Ductoscopy was the most efficient (75%) single method. CONCLUSION: Ductoscopy is a valuable test for diagnosing intraductal lesions in patients with nipple discharge. It is more efficient than conventional tests in patients undergoing all tests.


Asunto(s)
Enfermedades de la Mama/diagnóstico , Endoscopía/métodos , Pezones/patología , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
12.
Radiology ; 262(2): 435-49, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22282182

RESUMEN

PURPOSE: To determine whether adding shear-wave (SW) elastographic features could improve accuracy of ultrasonographic (US) assessment of breast masses. MATERIALS AND METHODS: From September 2008 to September 2010, 958 women consented to repeat standard breast US supplemented by quantitative SW elastographic examination in this prospective multicenter institutional review board-approved, HIPAA-compliant protocol. B-mode Breast Imaging Reporting and Data System (BI-RADS) features and assessments were recorded. SW elastographic evaluation (mean, maximum, and minimum elasticity of stiffest portion of mass and surrounding tissue; lesion-to-fat elasticity ratio; ratio of SW elastographic-to-B-mode lesion diameter or area; SW elastographic lesion shape and homogeneity) was performed. Qualitative color SW elastographic stiffness was assessed independently. Nine hundred thirty-nine masses were analyzable; 102 BI-RADS category 2 masses were assumed to be benign; reference standard was available for 837 category 3 or higher lesions. Considering BI-RADS category 4a or higher as test positive for malignancy, effect of SW elastographic features on area under the receiver operating characteristic curve (AUC), sensitivity, and specificity after reclassifying category 3 and 4a masses was determined. RESULTS: Median participant age was 50 years; 289 of 939 (30.8%) masses were malignant (median mass size, 12 mm). B-mode BI-RADS AUC was 0.950; eight of 303 (2.6%) BI-RADS category 3 masses, 18 of 193 (9.3%) category 4a lesions, 41 of 97 (42%) category 4b lesions, 42 of 57 (74%) category 4c lesions, and 180 of 187 (96.3%) category 5 lesions were malignant. By using visual color stiffness to selectively upgrade category 3 and lack of stiffness to downgrade category 4a masses, specificity improved from 61.1% (397 of 650) to 78.5% (510 of 650) (P<.001); AUC increased to 0.962 (P=.005). Oval shape on SW elastographic images and quantitative maximum elasticity of 80 kPa (5.2 m/sec) or less improved specificity (69.4% [451 of 650] and 77.4% [503 of 650], P<.001 for both), without significant improvement in sensitivity or AUC. CONCLUSION: Adding SW elastographic features to BI-RADS feature analysis improved specificity of breast US mass assessment without loss of sensitivity.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Aumento de la Imagen/métodos , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Anciano de 80 o más Años , Europa (Continente) , Femenino , Humanos , Internacionalidad , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resistencia al Corte , Estados Unidos , Adulto Joven
13.
Eur Radiol ; 22(12): 2633-40, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22772146

RESUMEN

OBJECTIVES: To investigate effects of menopausal status, oral contraceptives (OC), and postmenopausal hormone therapy (HT) on normal breast parenchymal contrast enhancement (CE) and non-mass-like enhancing areas in magnetic resonance mammography (MRM). METHODS: A total of 459 female volunteers (mean age 49.1 ± 12.5 years) underwent T1-weighted 3D MRM 1-5 min after bolus injection of gadobutrol. Quantitative analysis was performed in normal breast parenchyma by manually tracing regions of interest and calculating percentage CE. Semiquantitative analysis was performed in non-mass-like enhancing areas, and signal intensity changes were characterised by five predefined kinetic curve types. The influence of OC (n = 69) and HT (n = 24) on CE was studied using random effects models. RESULTS: Breast parenchymal enhancement was significantly higher in premenopausal than in postmenopausal women (P < 0.001). CE decreased significantly with the use of OC (P = 0.01), while HT had negligible effects (P = 0.52). Prevalence of kinetic curve types of non-mass-like enhancement differed strongly between pre- and postmenopausal women (P < 0.0001), but was similar in OC users and non-OC users (P = 0.61) as well as HT users and non-HT users (P = 0.77). CONCLUSIONS: Normal breast parenchymal enhancement and non-mass-like enhancing areas were strongly affected by menopausal status, while they were not affected by HT use and only moderately by OC use. KEY POINTS: Breast parenchymal enhancement at MR mammography is stronger in premenopausal than postmenopausal women. The prevalence of strong enhancing non-mass-like areas is greater before menopause. Such enhancing non-mass-like areas may impair lesion detection in premenopausal women. Breast parenchymal enhancement is only marginally affected by hormone use. Discontinuation of hormone use before MR mammography may be unnecessary.


Asunto(s)
Neoplasias de la Mama/patología , Medios de Contraste/farmacocinética , Imagen por Resonancia Magnética/métodos , Compuestos Organometálicos/farmacocinética , Adulto , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Anticonceptivos Orales/administración & dosificación , Terapia de Reemplazo de Estrógeno , Femenino , Humanos , Imagenología Tridimensional , Menopausia , Premenopausia , Estudios Prospectivos , Análisis de Regresión , Reproducibilidad de los Resultados
14.
Eur J Cancer ; 161: 1-9, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34879299

RESUMEN

BACKGROUND: Shear wave elastography (SWE) and strain elastography (SE) have shown promising potential in breast cancer diagnostics by evaluating the stiffness of a lesion. Combining these two techniques could further improve the diagnostic performance. We aimed to exploratorily define the cut-offs at which adding combined SWE and SE to B-mode breast ultrasound could help reclassify Breast Imaging Reporting and Data System (BI-RADS) 3-4 lesions to reduce the number of unnecessary breast biopsies. METHODS: We report the secondary results of a prospective, multicentre, international trial (NCT02638935). The trial enrolled 1288 women with BI-RADS 3 to 4c breast masses on conventional B-mode breast ultrasound. All patients underwent SWE and SE (index test) and histopathologic evaluation (reference standard). Reduction of unnecessary biopsies (biopsies in benign lesions) and missed malignancies after recategorising with SWE and SE were the outcome measures. RESULTS: On performing histopathologic evaluation, 368 of 1288 breast masses were malignant. Following the routine B-mode breast ultrasound assessment, 53.80% (495 of 920 patients) underwent an unnecessary biopsy. After recategorising BI-RADS 4a lesions (SWE cut-off ≥3.70 m/s, SE cut-off ≥1.0), 34.78% (320 of 920 patients) underwent an unnecessary biopsy corresponding to a 35.35% (320 versus 495) reduction of unnecessary biopsies. Malignancies in the new BI-RADS 3 cohort were missed in 1.96% (12 of 612 patients). CONCLUSION: Adding combined SWE and SE to routine B-mode breast ultrasound to recategorise BI-RADS 4a patients could help reduce the number of unnecessary biopsies in breast diagnostics by about 35% while keeping the rate of undetected malignancies below the 2% ACR BI-RADS 3 definition.


Asunto(s)
Biopsia/métodos , Neoplasias de la Mama/diagnóstico , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Humanos , Persona de Mediana Edad
15.
Eur J Cancer ; 177: 1-14, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36283244

RESUMEN

BACKGROUND: Breast ultrasound identifies additional carcinomas not detected in mammography but has a higher rate of false-positive findings. We evaluated whether use of intelligent multi-modal shear wave elastography (SWE) can reduce the number of unnecessary biopsies without impairing the breast cancer detection rate. METHODS: We trained, tested, and validated machine learning algorithms using SWE, clinical, and patient information to classify breast masses. We used data from 857 women who underwent B-mode breast ultrasound, SWE, and subsequent histopathologic evaluation at 12 study sites in seven countries from 2016 to 2019. Algorithms were trained and tested on data from 11 of the 12 sites and externally validated using the additional site's data. We compared findings to the histopathologic evaluation and compared the diagnostic performance between B-mode breast ultrasound, traditional SWE, and intelligent multi-modal SWE. RESULTS: In the external validation set (n = 285), intelligent multi-modal SWE showed a sensitivity of 100% (95% CI, 97.1-100%, 126 of 126), a specificity of 50.3% (95% CI, 42.3-58.3%, 80 of 159), and an area under the curve of 0.93 (95% CI, 0.90-0.96). Diagnostic performance was significantly higher compared to traditional SWE and B-mode breast ultrasound (P < 0.001). Unlike traditional SWE, positive-predictive values of intelligent multi-modal SWE were significantly higher compared to B-mode breast ultrasound. Unnecessary biopsies were reduced by 50.3% (79 versus 159, P < 0.001) without missing cancer compared to B-mode ultrasound. CONCLUSION: The majority of unnecessary breast biopsies might be safely avoided by using intelligent multi-modal SWE. These results may be helpful to reduce diagnostic burden for patients, providers, and healthcare systems.


Asunto(s)
Neoplasias de la Mama , Diagnóstico por Imagen de Elasticidad , Humanos , Femenino , Diagnóstico por Imagen de Elasticidad/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Estudios Retrospectivos , Ultrasonografía Mamaria , Biopsia , Sensibilidad y Especificidad , Reproducibilidad de los Resultados , Diagnóstico Diferencial
16.
Anticancer Res ; 41(6): 3075-3082, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34083300

RESUMEN

AIM: Quality of life and patient satisfaction after subpectoral breast reconstruction with meshes or acellular dermal matrices (ADM) and implants were assessed using the BreastQ questionnaire to investigate a potential influence of the materials on these parameters. PATIENTS AND METHODS: The BreastQ questionnaire was completed by 121 patients, who had received material-assisted, heterologous, subpectoral breast reconstruction between 2010 and 2018. RESULTS: Answers were similar independent of the reconstruction materials used. After prophylactic mastectomy, the physical wellbeing (chest) improved significantly with all materials (p=0.04). Postoperative radiotherapy significantly reduced satisfaction with outcome (p=0.005). Patients under 50 years old had significantly better postoperative sexual wellbeing than older patients (p=0.03). CONCLUSION: No influence was detected of the materials on the postoperative quality of life and patient satisfaction. An overall better quality of life was reported by younger and normal-weight patients with prophylactic or nipple-sparing mastectomy without radiotherapy.


Asunto(s)
Implantación de Mama/métodos , Implantes de Mama , Músculos Pectorales/cirugía , Calidad de Vida , Neoplasias de la Mama/psicología , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mastectomía , Satisfacción del Paciente , Estudios Retrospectivos
17.
In Vivo ; 35(5): 2739-2746, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34410963

RESUMEN

AIM: This research compares postoperative complication rates with Strattice™, SERAGYN® BR, and TiLOOP® Bra interposition devices for subpectoral implant placement after skin or nipple sparing mastectomy. PATIENTS AND METHODS: 188 breast reconstructions in 157 patients after primary (n=96), secondary (n=71), or prophylactic (n=21) surgery were analyzed regarding major and minor complications. RESULTS: With acellular dermal matrix (ADM) Strattice™, 27.5% major and 27.5% minor complications occurred. Implant loss rates were 27.3% in primary and 30.8% in secondary reconstructions. With SERAGYN® BR, 11.1% major and 13,0% minor complications occurred. Implant losses (6.1%) occurred exclusively in primary reconstructions. With TiLOOP® Bra, 14.9% major and 9.6% minor complications occurred. Implant loss rates were 7.7% in primary and 7.1% in secondary reconstructions. CONCLUSION: ADM was associated with high complication rates in primary and secondary reconstructions. Low complication rates were seen with mesh interposition devices in primary, secondary, and prophylactic reconstructions.


Asunto(s)
Dermis Acelular , Implantación de Mama , Implantes de Mama , Neoplasias de la Mama , Mamoplastia , Animales , Implantación de Mama/efectos adversos , Implantes de Mama/efectos adversos , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mamoplastia/efectos adversos , Mastectomía/efectos adversos , Polipropilenos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Porcinos
18.
Anticancer Res ; 41(4): 2017-2024, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33813408

RESUMEN

BACKGROUND/AIM: Synthetic meshes (SMs) and acellular dermal matrices (ADMs) are used in reconstructive breast surgery. In the absence of prospective comparative studies, the identification of differences relies on retrospective analyses. PATIENTS AND METHODS: Our analysis focused on the impact of pre- and postoperative radiotherapy (RTX) and material-related differences. The analysis included 281 breast cancer patients (362 breasts) after nipple- and skin-sparing mastectomy with subpectoral implant insertion. RESULTS: Overall, the implant loss rate was 23.1% using porcine ADM, 7% using partially resorbable SM (prSM), and 5.6% using non-resorbable SM (nrSM). After RTX, the implant loss rate was 56.3% with ADM, 13% with prSM and 13.2% with nrSM. The ADM group showed a significant effect of RTX on the postoperative seroma rate, wound infections, and implant loss rate. When prSM was used, RTX showed no significant effect. When using the nrSM, RTX significantly influenced complication rates regarding wound infections and implant loss. CONCLUSION: In material-assisted breast reconstructions with pre- or post-operative RTX, there is a significantly higher implant loss rate when using porcine ADM compared to SM.


Asunto(s)
Dermis Acelular , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Mamoplastia , Radioterapia Adyuvante/efectos adversos , Mallas Quirúrgicas , Adulto , Anciano , Implantación de Mama/instrumentación , Implantación de Mama/métodos , Implantes de Mama , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Femenino , Humanos , Mamoplastia/instrumentación , Mamoplastia/métodos , Mastectomía Segmentaria/instrumentación , Mastectomía Segmentaria/métodos , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Pronóstico , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
19.
Anticancer Res ; 41(2): 859-867, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33517291

RESUMEN

BACKGROUND/AIM: This trial intended to identify patient- and therapy-specific risk factors influencing the genesis of seroma and the extent of its formation. PATIENTS AND METHODS: Within a prospective randomized controlled trial, 70 patients (n=35 TissuGlu®; n=35 drain) underwent a mastectomy with or without sentinel lymphonodectomy. Specific seroma-associated risk factors were recorded. Regular outpatient aftercare was performed during a 90-day postoperative follow-up. RESULTS: A statistically significant increase in the postoperative seroma rate was demonstrated for those with pre-adiposity compared to normal body weight (p=0.016), as well as for the state of health evaluated by the score of American Society of Anesthesiologists (ASA) (ASA III compared to I; p=0.046), the presence of diabetes mellitus (p<0.001) and the reduction of the length of the surgical procedure (p=0.044). CONCLUSION: A high body mass index, a poor state of health (ASA score), and diabetes mellitus, as well as a shorter duration of surgery, favor the incidence of postoperative seroma.


Asunto(s)
Neoplasias de la Mama/cirugía , Diabetes Mellitus/epidemiología , Mastectomía/efectos adversos , Complicaciones Posoperatorias/epidemiología , Seroma/etiología , Anciano , Anciano de 80 o más Años , Peso Corporal , Femenino , Humanos , Escisión del Ganglio Linfático , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Factores de Riesgo , Ganglio Linfático Centinela/cirugía , Seroma/epidemiología
20.
Int J Gynecol Cancer ; 20(1): 179-83, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20130520

RESUMEN

BACKGROUND: Mesh reconstruction, especially in combination with vacuum-assisted closure, might improve healing and reduce the surgical morbidity of extensive inguinofemoral lymphadenectomy or extensive local resection in progressive cancer of the vulva. CASES: Radical vulvectomy combined with inguinofemoral lymphadenectomy was performed in 2 patients (P1, P2). The inguinofemoral wound bed was stabilized by polypropylene mesh implantation and sealed with vacuum closure system. In 1 patient with local recurrence of vulvar cancer (P3), local excision and stabilization of the wound were performed by mesh implantation. CONCLUSIONS: Mesh implantation fulfills 2 purposes: (1) it protects exposed vessels and the wound can be vacuum sealed; and (2) it stabilizes the surgical bed, permitting the required radical excision locally and inside the vascular compartment.


Asunto(s)
Carcinoma/cirugía , Terapia de Presión Negativa para Heridas/métodos , Recurrencia Local de Neoplasia/cirugía , Polipropilenos/uso terapéutico , Mallas Quirúrgicas , Neoplasias de la Vulva/cirugía , Adulto , Anciano , Carcinoma/patología , Terapia Combinada , Femenino , Humanos , Metástasis de la Neoplasia , Neoplasias de la Vulva/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA