RESUMEN
BACKGROUND: A simultaneous integrated boost (SIB) may result in increased out-of-field (DOOF) and photoneutron (HPN) doses in volumetric modulated arc therapy (VMAT) for prostate cancer (PCA). This work therefore aimed to compare DOOF and HPN in flattened (FLAT) and flattening filter-free (FFF) 6MV and 10-MV VMAT treatment plans with and without SIB. METHODS: Eight groups of 30 VMAT plans for PCA with 6 MV or 10 MV, with or without FF and with uniform (2â¯Gy) or SIB target dose (2.5/3.0â¯Gy) prescriptions (CONV, SIB), were generated. All 240 plans were delivered on a slab-phantom and compared with respect to measured DOOF and HPN in 61.8â¯cm distance from the isocenter. The 6 and 10-MV flattened VMAT plans with conventional fractionation (6- and 10-MV FLAT CONV) served as standard reference groups. Doses were analyzed as a function of delivered monitor units (MU) and weighted equivalent square field size Aeq. Pearson's correlation coefficients between the presented quantities were determined. RESULTS: The SIB plans resulted in decreased HPN over an entire prostate RT treatment course (10-MV SIB vs. CONV -38.2%). Omission of the flattening filter yielded less HPN (10-MV CONV -17.2%; 10-MV SIB -22.5%). The SIB decreased DOOF likewise by 39% for all given scenarios, while the FFF mode reduced DOOF on average by 60%. A strong Pearson correlation was found between MU and HPN (râ¯> 0.9) as well as DOOF (0.7â¯< râ¯< 0.9). CONCLUSION: For a complete treatment, SIB reduces both photoneutron and OOF doses to almost the same extent as FFF deliveries. It is recommended to apply moderately hypofractionated 6MV SIB FFF-VMAT when considering photoneutron or OOF doses.
Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Próstata/radioterapia , Fraccionamiento de la Dosis de Radiación , Próstata , Dosificación RadioterapéuticaRESUMEN
BACKGROUND: Stereotactic body radiotherapy (SBRT) is an effective therapeutic approach in patients with liver metastases. However, long-term changes in hepatic normal tissue have to be taken into account in multimodal treatment regimes. Magnetic-resonance-imaging (MRI) based morphologic liver alterations (MMA) after liver SBRT have been analyzed longitudinally. MATERIAL AND METHODS: 57 patients treated with gantry-based or robotic-based SBRT of 69 treatment volumes of liver metastases, who had long-term follow-up (FU) ≥6 months were included in this retrospective analysis. Post-SBRT MMAs were contoured on each contrast-enhanced-T1-weighted (T1w) MRI-sequence. Morphologic/volumetric data of the liver and MMAs were evaluated longitudinally, including the dependency on treatment-related factors of the planning target volume (PTV) and liver. RESULTS: The median FU time was 1 year [6-48 months]. 66 of 69 treatment volumes developed MMAs (mean 143.8 ± 135.1 ccm at first appearance). 31.8% of MMAs resolved completely during FU. Of the persisting MMAs 82.2%/13.3% decreased/increased in size until last available FU. Morphological characterization of the MMAs at first appearance included 75% hypointense and 25% hyperintense T1w-MRI-based appearances. Hypointense as compared to hyperintense appearance was significantly associated with a higher mean liver dose EQD2α/ß=3 Gy (p = 0.0212) and non-significantly greater MMA size. Variance analysis demonstrated a significant reduction of MMA and total liver volume after SBRT (p < 0.0001). The volume reduction decelerated longitudinally for both MMA (p < 0.0001) and liver size (p = 0.0033). Radiation doses (PTV-BEDα/ß=3 Gy and 10 Gy) were not significantly associated with MMA volume reduction. SBRT of liver metastases with mean liver dose EQD2α/ß=3 Gy > 18 Gy were characterized by greater MMA volumes (p = 0.0826) and steeper MMA reduction gradients during FU than those with EQD2α/ß=3 Gy ≤ 18 Gy (p < 0.0001). CONCLUSION: Radiogenic MMAs either completely resolve or usually decrease in volume with pronounced reduction during short-term FU. This course was independent of the MMA's morphological appearance. Further, increased mean liver dose was associated with greater MMA size and a greater gradient of MMA size reduction during FU.