Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Am J Physiol Gastrointest Liver Physiol ; 326(2): G95-G106, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38014449

RESUMEN

Dried blood spot (DBS) analysis has existed for >50 years, but application of this technique to fecal analysis remains limited. To address whether dried fecal spots (DFS) could be used to measure fecal bile acids, we collected feces from five subjects for each of the following cohorts: 1) healthy individuals, 2) individuals with diarrhea, and 3) Clostridioides difficile-infected patients. Homogenized fecal extracts were loaded onto quantitative DBS (qDBS) devices, dried overnight, and shipped to the bioanalytical lab at ambient temperature. For comparison, source fecal extracts were shipped on dry ice and stored frozen. After 4 mo, frozen fecal extracts and ambient DFS samples were processed and subjected to targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based metabolomics with stable isotope-labeled standards. We observed no differences in the bile acid levels measured between the traditional extraction and the qDBS-based DFS methods. This pilot data demonstrates that DFS-based analysis is feasible and warrants further development for fecal compounds and microbiome applications.NEW & NOTEWORTHY Stool analysis in remote settings can be challenging, as the samples must be stored at -80°C and transported on dry ice for downstream processing. Our work indicates that dried fecal spots (DFS) on Capitainer quantitative DBS (qDBS) devices can be stored and shipped at ambient temperature and yields the same bile acid profiles as traditional samples. This approach has broad applications for patient home testing and sample collection in rural communities or resource-limited countries.


Asunto(s)
Hielo Seco , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Tecnología , Ácidos y Sales Biliares
2.
Metabolomics ; 18(4): 24, 2022 04 09.
Artículo en Inglés | MEDLINE | ID: mdl-35397018

RESUMEN

INTRODUCTION: The metabolomics quality assurance and quality control consortium (mQACC) is enabling the identification, development, prioritization, and promotion of suitable reference materials (RMs) to be used in quality assurance (QA) and quality control (QC) for untargeted metabolomics research. OBJECTIVES: This review aims to highlight current RMs, and methodologies used within untargeted metabolomics and lipidomics communities to ensure standardization of results obtained from data analysis, interpretation and cross-study, and cross-laboratory comparisons. The essence of the aims is also applicable to other 'omics areas that generate high dimensional data. RESULTS: The potential for game-changing biochemical discoveries through mass spectrometry-based (MS) untargeted metabolomics and lipidomics are predicated on the evolution of more confident qualitative (and eventually quantitative) results from research laboratories. RMs are thus critical QC tools to be able to assure standardization, comparability, repeatability and reproducibility for untargeted data analysis, interpretation, to compare data within and across studies and across multiple laboratories. Standard operating procedures (SOPs) that promote, describe and exemplify the use of RMs will also improve QC for the metabolomics and lipidomics communities. CONCLUSIONS: The application of RMs described in this review may significantly improve data quality to support metabolomics and lipidomics research. The continued development and deployment of new RMs, together with interlaboratory studies and educational outreach and training, will further promote sound QA practices in the community.


Asunto(s)
Lipidómica , Metabolómica , Espectrometría de Masas/métodos , Metabolómica/métodos , Control de Calidad , Reproducibilidad de los Resultados
3.
Mol Cell Proteomics ; 18(12): 2433-2446, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31591263

RESUMEN

Stable isotope-labeled standard (SIS) peptides are used as internal standards in targeted proteomics to provide robust protein quantification, which is required in clinical settings. However, SIS peptides are typically added post trypsin digestion and, as the digestion efficiency can vary significantly between peptides within a protein, the accuracy and precision of the assay may be compromised. These drawbacks can be remedied by a new class of internal standards introduced by the Human Protein Atlas project, which are based on SIS recombinant protein fragments called SIS PrESTs. SIS PrESTs are added initially to the sample and SIS peptides are released on trypsin digestion. The SIS PrEST technology is promising for absolute quantification of protein biomarkers but has not previously been evaluated in a clinical setting. An automated and scalable solid phase extraction workflow for desalting and enrichment of plasma digests was established enabling simultaneous preparation of up to 96 samples. Robust high-precision quantification of 13 apolipoproteins was achieved using a novel multiplex SIS PrEST-based LC-SRM/MS Tier 2 assay in non-depleted human plasma. The assay exhibited inter-day coefficients of variation between 1.5% and 14.5% (median = 3.5%) and was subsequently used to investigate the effects of omega-3 carboxylic acids (OM3-CA) and fenofibrate on these 13 apolipoproteins in human plasma samples from a randomized placebo-controlled trial, EFFECT I (NCT02354976). No significant changes were observed in the OM3-CA arm, whereas treatment with fenofibrate significantly increased apoAII and reduced apoB, apoCI, apoE and apoCIV levels. The reduction in apoCIV following fenofibrate treatment is a novel finding. The study demonstrates that SIS PrESTs can facilitate the generation of robust multiplexed biomarker Tier 2 assays for absolute quantification of proteins in clinical studies.


Asunto(s)
Apolipoproteínas/sangre , Ácidos Carboxílicos/farmacología , Ácidos Grasos Omega-3/farmacología , Fenofibrato/farmacología , Marcaje Isotópico , Espectrometría de Masas en Tándem/métodos , Adulto , Anciano , Biomarcadores/sangre , Estudios de Cohortes , Método Doble Ciego , Humanos , Marcaje Isotópico/normas , Persona de Mediana Edad , Fragmentos de Péptidos , Proteínas Recombinantes , Reproducibilidad de los Resultados
4.
Proteomics ; 17(6)2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27538354

RESUMEN

An increasingly popular "absolute" quantitative technique involves the SRM or MRM approach with stable isotope-labeled standards (SIS). Using this approach, many proteins in human plasma/serum have been quantified for biomarker assessment and disease stratification. Due to the complexity of plasma and the invasive nature of its collection, alternative biosamples are currently being explored. Here, we present the broadest panel of multiplexed MRM assays with SIS peptides for saliva proteins developed to date. The validated panel consists of 158 candidate human saliva protein biomarkers, inferred from 244 interference-free peptides. The resulting concentrations were reproducibly quantified over a 6 order-of-magnitude concentration range (from 218 µg/mL to 88 pg/mL; average CVs of 12% over analytical triplicates). All concentrations were determined from reverse standard curves, which were generated using a constant concentration of endogenous material with varying concentrations of spiked-in SIS peptides. The large-scale screening of the soluble and membrane-associated proteins contained within the 158-plex assay could present new opportunities for biomarker assessment and clinical diagnostics.


Asunto(s)
Biomarcadores/metabolismo , Proteómica/métodos , Proteínas y Péptidos Salivales/metabolismo , Adulto , Femenino , Humanos , Masculino , Péptidos/metabolismo , Reproducibilidad de los Resultados , Saliva/metabolismo , Adulto Joven
5.
Proteomics ; 17(7)2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27688154

RESUMEN

The mouse is the most commonly used laboratory animal, with more than 14 million mice being used for research each year in North America alone. The number and diversity of mouse models is increasing rapidly through genetic engineering strategies, but detailed characterization of these models is still challenging because most phenotypic information is derived from time-consuming histological and biochemical analyses. To expand the biochemists' toolkit, we generated a set of targeted proteomic assays for mouse plasma and heart tissue, utilizing bottom-up LC/MRM-MS with isotope-labeled peptides as internal standards. Protein quantitation was performed using reverse standard curves, with LC-MS platform and curve performance evaluated by quality control standards. The assays comprising the final panel (101 peptides for 81 proteins in plasma; 227 peptides for 159 proteins in heart tissue) have been rigorously developed under a fit-for-purpose approach and utilize stable-isotope labeled peptides for every analyte to provide high-quality, precise relative quantitation. In addition, the peptides have been tested to be interference-free and the assay is highly multiplexed, with reproducibly determined protein concentrations spanning >4 orders of magnitude. The developed assays have been used in a small pilot study to demonstrate their application to molecular phenotyping or biomarker discovery/verification studies.


Asunto(s)
Proteínas Sanguíneas/análisis , Miocardio/metabolismo , Animales , Biomarcadores/sangre , Cromatografía Liquida/métodos , Marcaje Isotópico , Espectrometría de Masas/métodos , Ratones , Ratones Endogámicos C57BL , Miocardio/química
6.
J Proteome Res ; 16(7): 2527-2536, 2017 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-28516774

RESUMEN

When quantifying endogenous plasma proteins for fundamental and biomedical research - as well as for clinical applications - precise, reproducible, and robust assays are required. Targeted detection of peptides in a bottom-up strategy is the most common and precise mass spectrometry-based quantitation approach when combined with the use of stable isotope-labeled peptides. However, when measuring protein in plasma, the unknown endogenous levels prevent the implementation of the best calibration strategies, since no blank matrix is available. Consequently, several alternative calibration strategies are employed by different laboratories. In this study, these methods were compared to a new approach using two different stable isotope-labeled standard (SIS) peptide isotopologues for each endogenous peptide to be quantified, enabling an external calibration curve as well as the quality control samples to be prepared in pooled human plasma without interference from endogenous peptides. This strategy improves the analytical performance of the assay and enables the accuracy of the assay to be monitored, which can also facilitate method development and validation.


Asunto(s)
Bioensayo , Proteínas Sanguíneas/normas , Cromatografía Liquida/normas , Espectrometría de Masas/normas , Péptidos/sangre , Proteómica/normas , Secuencia de Aminoácidos , Aminoácidos/química , Proteínas Sanguíneas/química , Calibración , Isótopos de Carbono , Humanos , Marcaje Isotópico/métodos , Isótopos de Nitrógeno , Péptidos/normas , Proteómica/métodos , Estándares de Referencia , Coloración y Etiquetado/métodos
7.
Mol Cell Proteomics ; 14(11): 3094-104, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26342038

RESUMEN

The dried blood spot (DBS) methodology provides a minimally invasive approach to sample collection and enables room-temperature storage for most analytes. DBS samples have successfully been analyzed by liquid chromatography multiple reaction monitoring mass spectrometry (LC/MRM-MS) to quantify a large range of small molecule biomarkers and drugs; however, this strategy has only recently been explored for MS-based proteomics applications. Here we report the development of a highly multiplexed MRM assay to quantify endogenous proteins in human DBS samples. This assay uses matching stable isotope-labeled standard peptides for precise, relative quantification, and standard curves to characterize the analytical performance. A total of 169 peptides, corresponding to 97 proteins, were quantified in the final assay with an average linear dynamic range of 207-fold and an average R(2) value of 0.987. The total range of this assay spanned almost 5 orders of magnitude from serum albumin (P02768) at 18.0 mg/ml down to cholinesterase (P06276) at 190 ng/ml. The average intra-assay and inter-assay precision for 6 biological samples ranged from 6.1-7.5% CV and 9.5-11.0% CV, respectively. The majority of peptide targets were stable after 154 days at storage temperatures from -20 °C to 37 °C. Furthermore, protein concentration ratios between matching DBS and whole blood samples were largely constant (<20% CV) across six biological samples. This assay represents the highest multiplexing yet achieved for targeted protein quantification in DBS samples and is suitable for biomedical research applications.


Asunto(s)
Bioensayo , Proteínas Sanguíneas/aislamiento & purificación , Pruebas con Sangre Seca/normas , Péptidos/aislamiento & purificación , Cromatografía Liquida , Pruebas con Sangre Seca/instrumentación , Pruebas con Sangre Seca/métodos , Humanos , Marcaje Isotópico , Estabilidad Proteica , Proteómica , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem
8.
Expert Rev Proteomics ; 13(7): 673-84, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27341553

RESUMEN

INTRODUCTION: Aided by the advent of advanced mass spectrometry (MS)-based technologies and methodologies, quantitative proteomics has emerged as a viable technique to capture meaningful data for candidate biomarker evaluation. To aid clinical translation, these methods generally utilize a bottom-up strategy with isotopically labeled standards and a targeted form of MS measurement. AREAS COVERED: This article reviews the status, challenges, requirements, and potential of translating current, MS-based methods to the clinical laboratory. The described methods are discussed and contrasted within a fit-for-purpose approach, while different resources for quality control, quantitative analysis, and data interpretation are additionally provided. Expert commentary: Although great strides have been made over the past five years in developing reliable quantitative assays for plasma protein biomarkers, it is crucial for investigators to have an understanding of the clinical validation process, a major roadblock in translational research. Continued progress in method design and validation of protein assays is necessary to ultimately achieve widespread adoption and regulatory approval.


Asunto(s)
Biomarcadores/sangre , Proteínas Sanguíneas/genética , Espectrometría de Masas , Proteómica , Proteínas Sanguíneas/biosíntesis , Humanos
9.
Methods ; 81: 24-33, 2015 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-25858257

RESUMEN

Spurred on by the growing demand for panels of validated disease biomarkers, increasing efforts have focused on advancing qualitative and quantitative tools for more highly multiplexed and sensitive analyses of a multitude of analytes in various human biofluids. In quantitative proteomics, evolving strategies involve the use of the targeted multiple reaction monitoring (MRM) mode of mass spectrometry (MS) with stable isotope-labeled standards (SIS) used for internal normalization. Using that preferred approach with non-invasive urine samples, we have systematically advanced and rigorously assessed the methodology toward the precise quantitation of the largest, multiplexed panel of candidate protein biomarkers in human urine to date. The concentrations of the 136 proteins span >5 orders of magnitude (from 8.6 µg/mL to 25 pg/mL), with average CVs of 8.6% over process triplicate. Detailed here is our quantitative method, the analysis strategy, a feasibility application to prostate cancer samples, and a discussion of the utility of this method in translational studies.


Asunto(s)
Biomarcadores de Tumor/orina , Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Proteínas de Neoplasias/orina , Anciano , Radioisótopos de Carbono , Cromatografía Liquida/normas , Humanos , Masculino , Espectrometría de Masas/normas , Radioisótopos de Nitrógeno , Péptidos/normas , Neoplasias de la Próstata/diagnóstico , Proteómica/métodos , Estándares de Referencia , Urinálisis/métodos
10.
Adv Exp Med Biol ; 919: 515-530, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27975233

RESUMEN

Quantitative mass spectrometry (MS)-based approaches are emerging as a core technology for addressing health-related queries in systems biology and in the biomedical and clinical fields. In several 'omics disciplines (proteomics included), an approach centered on selected or multiple reaction monitoring (SRM or MRM)-MS with stable isotope-labeled standards (SIS), at the protein or peptide level, has emerged as the most precise technique for quantifying and screening putative analytes in biological samples. To enable the widespread use of MRM-based protein quantitation for disease biomarker assessment studies and its ultimate acceptance for clinical analysis, the technique must be standardized to facilitate precise and accurate protein quantitation. To that end, we have developed a number of kits for assessing method/platform performance, as well as for screening proposed candidate protein biomarkers in various human biofluids. Collectively, these kits utilize a bottom-up LC-MS methodology with SIS peptides as internal standards and quantify proteins using regression analysis of standard curves. This chapter details the methodology used to quantify 192 plasma proteins of high-to-moderate abundance (covers a 6 order of magnitude range from 31 mg/mL for albumin to 18 ng/mL for peroxidredoxin-2), and a 21-protein subset thereof. We also describe the application of this method to patient samples for biomarker discovery and verification studies. Additionally, we introduce our recently developed Qualis-SIS software, which is used to expedite the analysis and assessment of protein quantitation data in control and patient samples.


Asunto(s)
Biología Computacional/métodos , Minería de Datos/métodos , Bases de Datos de Proteínas , Espectrometría de Masas/métodos , Proteínas/análisis , Proteoma , Proteómica/métodos , Algoritmos , Biomarcadores/análisis , Calibración , Biología Computacional/normas , Minería de Datos/normas , Ensayos Analíticos de Alto Rendimiento , Humanos , Espectrometría de Masas/normas , Valor Predictivo de las Pruebas , Proteómica/normas , Estándares de Referencia , Reproducibilidad de los Resultados , Programas Informáticos
11.
J Proteome Res ; 14(2): 1137-46, 2015 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-25546269

RESUMEN

Multiplexed targeted quantitative proteomics typically utilizes multiple reaction monitoring and allows the optimized quantification of a large number of proteins. One challenge, however, is the large amount of data that needs to be reviewed, analyzed, and interpreted. Different vendors provide software for their instruments, which determine the recorded responses of the heavy and endogenous peptides and perform the response-curve integration. Bringing multiplexed data together and generating standard curves is often an off-line step accomplished, for example, with spreadsheet software. This can be laborious, as it requires determining the concentration levels that meet the required accuracy and precision criteria in an iterative process. We present here a computer program, Qualis-SIS, that generates standard curves from multiplexed MRM experiments and determines analyte concentrations in biological samples. Multiple level-removal algorithms and acceptance criteria for concentration levels are implemented. When used to apply the standard curve to new samples, the software flags each measurement according to its quality. From the user's perspective, the data processing is instantaneous due to the reactivity paradigm used, and the user can download the results of the stepwise calculations for further processing, if necessary. This allows for more consistent data analysis and can dramatically accelerate the downstream data analysis.


Asunto(s)
Automatización , Proteómica , Estándares de Referencia , Algoritmos
12.
Biochim Biophys Acta ; 1844(5): 917-26, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23806606

RESUMEN

Accurate and rapid protein quantitation is essential for screening biomarkers for disease stratification and monitoring, and to validate the hundreds of putative markers in human biofluids, including blood plasma. An analytical method that utilizes stable isotope-labeled standard (SIS) peptides and selected/multiple reaction monitoring-mass spectrometry (SRM/MRM-MS) has emerged as a promising technique for determining protein concentrations. This targeted approach has analytical merit, but its true potential (in terms of sensitivity and multiplexing) has yet to be realized. Described herein is a method that extends the multiplexing ability of the MRM method to enable the quantitation 142 high-to-moderate abundance proteins (from 31mg/mL to 44ng/mL) in undepleted and non-enriched human plasma in a single run. The proteins have been reported to be associated to a wide variety of non-communicable diseases (NCDs), from cardiovascular disease (CVD) to diabetes. The concentrations of these proteins in human plasma are inferred from interference-free peptides functioning as molecular surrogates (2 peptides per protein, on average). A revised data analysis strategy, involving the linear regression equation of normal control plasma, has been instituted to enable the facile application to patient samples, as demonstrated in separate nutrigenomics and CVD studies. The exceptional robustness of the LC/MS platform and the quantitative method, as well as its high throughput, makes the assay suitable for application to patient samples for the verification of a condensed or complete protein panel. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge.


Asunto(s)
Biomarcadores/análisis , Proteínas Sanguíneas/metabolismo , Enfermedades Cardiovasculares/diagnóstico , Espectrometría de Masas/métodos , Fragmentos de Péptidos/análisis , Adolescente , Adulto , Anciano , Enfermedades Cardiovasculares/metabolismo , Cromatografía Liquida , Estudios de Cohortes , Femenino , Humanos , Marcaje Isotópico , Masculino , Persona de Mediana Edad , Nutrigenómica , Extremidad Superior , Adulto Joven
13.
Mol Cell Proteomics ; 12(3): 781-91, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23221968

RESUMEN

Dried blood spot (DBS) sampling, coupled with multiple reaction monitoring mass spectrometry (MRM-MS), is a well-established approach for quantifying a wide range of small molecule biomarkers and drugs. This sampling procedure is simpler and less-invasive than those required for traditional plasma or serum samples enabling collection by minimally trained personnel. Many analytes are stable in the DBS format without refrigeration, which reduces the cost and logistical challenges of sample collection in remote locations. These advantages make DBS sample collection desirable for advancing personalized medicine through population-wide biomarker screening. Here we expand this technology by demonstrating the first multiplexed method for the quantitation of endogenous proteins in DBS samples. A panel of 60 abundant proteins in human blood was targeted by monitoring proteotypic tryptic peptides and their stable isotope-labeled analogs by MRM. Linear calibration curves were obtained for 40 of the 65 peptide targets demonstrating multiple proteins can be quantitatively extracted from DBS collection cards. The method was also highly reproducible with a coefficient of variation of <15% for all 40 peptides. Overall, this assay quantified 37 proteins spanning a range of more than four orders of magnitude in concentration within a single 25 min LC/MRM-MS analysis. The protein abundances of the 33 proteins quantified in matching DBS and whole blood samples showed an excellent correlation, with a slope of 0.96 and an R(2) value of 0.97. Furthermore, the measured concentrations for 80% of the proteins were stable for at least 10 days when stored at -20 °C, 4 °C and 37 °C. This work represents an important first step in evaluating the integration of DBS sampling with highly-multiplexed MRM for quantitation of endogenous proteins.


Asunto(s)
Proteínas Sanguíneas/análisis , Pruebas con Sangre Seca/métodos , Espectrometría de Masas/métodos , Proteoma/análisis , Proteómica/métodos , Secuencia de Aminoácidos , Recolección de Muestras de Sangre/métodos , Calibración , Cromatografía Liquida/métodos , Humanos , Datos de Secuencia Molecular , Péptidos/análisis , Péptidos/sangre , Péptidos/metabolismo , Estabilidad Proteica , Reproducibilidad de los Resultados , Temperatura , Factores de Tiempo , Tripsina/metabolismo
14.
J Proteome Res ; 13(8): 3733-3747, 2014 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-24911472

RESUMEN

Multiplexed quantitation is essential for discovering, verifying, and validating biomarkers for risk stratification, disease prognostication, and therapeutic monitoring. The most promising strategy for quantifying unverified protein biomarkers in biofluids relies on selected/multiple reaction monitoring (SRM or MRM) technology with isotopically labeled standards employed within a bottom-up proteomic workflow. Since cerebrospinal fluid (CSF) is an important fluid for studying central nervous system (CNS) related diseases, we sought to develop a rapid, antibody- and fractionation-free MRM-based approach with a complex mixture of peptide standards to quantify a highly multiplexed panel of candidate protein biomarkers in human CSF. Development involved peptide transition optimization, denaturation/digestion protocol evaluation, transition interference screening, and protein quantitation via peptide standard curves. The final method exhibited excellent reproducibility (average coefficient of variation of <1% for retention time and <6% for signal) and breadth of quantitation (130 proteins from 311 interference-free peptides) in a single 43-min run. These proteins are of high-to-low abundance with determined concentrations from 118 µg/mL (serum albumin) to 550 pg/mL (apolipoprotein C-I). Overall, the method consists of the most highly multiplexed and broadest panel of candidate protein biomarkers in human CSF reported thus far and is well suited for subsequent verification studies on patient samples.

15.
Expert Rev Proteomics ; 11(2): 137-48, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24476379

RESUMEN

Accurate cancer biomarkers are needed for early detection, disease classification, prediction of therapeutic response and monitoring treatment. While there appears to be no shortage of candidate biomarker proteins, a major bottleneck in the biomarker pipeline continues to be their verification by enzyme linked immunosorbent assays. Multiple reaction monitoring (MRM), also known as selected reaction monitoring, is a targeted mass spectrometry approach to protein quantitation and is emerging to bridge the gap between biomarker discovery and clinical validation. Highly multiplexed MRM assays are readily configured and enable simultaneous verification of large numbers of candidates facilitating the development of biomarker panels which can increase specificity. This review focuses on recent applications of MRM to the analysis of plasma and serum from cancer patients for biomarker verification. The current status of this approach is discussed along with future directions for targeted mass spectrometry in clinical biomarker validation.


Asunto(s)
Biomarcadores de Tumor/sangre , Neoplasias/diagnóstico , Proteínas/análisis , Proteoma/análisis , Humanos , Espectrometría de Masas/métodos , Neoplasias/sangre
16.
Top Curr Chem ; 336: 117-37, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-22886709

RESUMEN

Clinical biomarker discovery, verification, and validation are facilitated by the latest technological advances in mass spectrometry. It is now possible to analyze simultaneously group of tens or hundreds of biomarkers in a blood sample using multiple reaction monitoring (MRM), a tandem mass spectrometric method. However, these newly-developed methods face new challenges, including standardization, calibration, and the determination of analytical and biological variation. Here we illustrate the background, pre-analytical sample preparation, and biomarker assay development using an MRM-mass spectrometric method. In addition, special attention is given to future standardization methods to enable widespread use of the technology.


Asunto(s)
Biomarcadores/análisis , Ensayos Analíticos de Alto Rendimiento/métodos , Espectrometría de Masas en Tándem/métodos , Interpretación Estadística de Datos , Humanos , Proteómica , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
17.
Proteomics ; 13(14): 2202-15, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23592487

RESUMEN

An emerging approach for multiplexed targeted proteomics involves bottom-up LC-MRM-MS, with stable isotope-labeled internal standard peptides, to accurately quantitate panels of putative disease biomarkers in biofluids. In this paper, we used this approach to quantitate 27 candidate cancer-biomarker proteins in human plasma that had not been treated by immunoaffinity depletion or enrichment techniques. These proteins have been reported as biomarkers for a variety of human cancers, from laryngeal to ovarian, with breast cancer having the highest correlation. We implemented measures to minimize the analytical variability, improve the quantitative accuracy, and increase the feasibility and applicability of this MRM-based method. We have demonstrated excellent retention time reproducibility (median interday CV: 0.08%) and signal stability (median interday CV: 4.5% for the analytical platform and 6.1% for the bottom-up workflow) for the 27 biomarker proteins (represented by 57 interference-free peptides). The linear dynamic range for the MRM assays spanned four orders-of-magnitude, with 25 assays covering a 10(3) -10(4) range in protein concentration. The lowest abundance quantifiable protein in our biomarker panel was insulin-like growth factor 1 (calculated concentration: 127 ng/mL). Overall, the analytical performance of this assay demonstrates high robustness and sensitivity, and provides the necessary throughput and multiplexing capabilities required to verify and validate cancer-associated protein biomarker panels in human plasma, prior to clinical use.


Asunto(s)
Biomarcadores de Tumor/sangre , Proteínas Sanguíneas/química , Proteoma/análisis , Proteómica/métodos , Adolescente , Adulto , Biomarcadores de Tumor/química , Biomarcadores de Tumor/aislamiento & purificación , Femenino , Humanos , Masculino , Espectrometría de Masas , Persona de Mediana Edad , Fragmentos de Péptidos/análisis , Fragmentos de Péptidos/química , Proteoma/química , Reproducibilidad de los Resultados
18.
J Proteome Res ; 12(1): 222-33, 2013 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-23245390

RESUMEN

Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.


Asunto(s)
Proteínas Sanguíneas , Neuropéptidos , Proteómica/normas , Proteínas Sanguíneas/análisis , Proteínas Sanguíneas/normas , Humanos , Espectrometría de Masas , Neuropéptidos/genética , Neuropéptidos/aislamiento & purificación , Neuropéptidos/metabolismo , Control de Calidad , Flujo de Trabajo
19.
Expert Rev Proteomics ; 10(6): 567-78, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24206229

RESUMEN

Despite significant advances in treatment, cardiovascular disease (CVD) remains one of the leading causes of morbidity and mortality in developed and developing countries. Judicious monitoring of common risk factors has been unable to control this global epidemic, necessitating novel biomarkers for improved screening and earlier disease detection and management. Although numerous plasma proteins have been associated with CVD, only a few of these potential biomarkers have been validated for clinical use. Here we review the quantitative proteomic methods used to verify and validate new biomarker candidates in human plasma. These methods center on a bottom-up approach involving multiple or selected reaction monitoring, for targeted detection, with stable isotope-labeled standards, for peptide normalization. Also included are a discussion of future strategies for improved CVD protein biomarker verification and validation, recommendations for method translation to the clinic, and future projections for protein biomarker research.


Asunto(s)
Proteínas Sanguíneas/análisis , Enfermedades Cardiovasculares/sangre , Proteómica/métodos , Estudios de Validación como Asunto , Biomarcadores/análisis , Enfermedades Cardiovasculares/diagnóstico , Humanos , Marcaje Isotópico/métodos , Espectrometría de Masas/métodos
20.
PLoS One ; 18(2): e0281772, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36791076

RESUMEN

Lipoprotein(a), also known as Lp(a), is an LDL-like particle composed of apolipoprotein(a) (apo(a)) bound covalently to apolipoprotein B100. Plasma concentrations of Lp(a) are highly heritable and vary widely between individuals. Elevated plasma concentration of Lp(a) is considered as an independent, causal risk factor of cardiovascular disease (CVD). Targeted mass spectrometry (LC-SRM/MS) combined with stable isotope-labeled recombinant proteins provides robust and precise quantification of proteins in the blood, making LC-SRM/MS assays appealing for monitoring plasma proteins for clinical implications. This study presents a novel quantitative approach, based on proteotypic peptides, to determine the absolute concentration of apo(a) from two microliters of plasma and qualified according to guideline requirements for targeted proteomics assays. After optimization, assay parameters such as linearity, lower limits of quantification (LLOQ), intra-assay variability (CV: 4.7%) and inter-assay repeatability (CV: 7.8%) were determined and the LC-SRM/MS results were benchmarked against a commercially available immunoassay. In summary, the measurements of an apo(a) single copy specific peptide and a kringle 4 specific peptide allow for the determination of molar concentration and relative size of apo(a) in individuals.


Asunto(s)
Apolipoproteínas A , Proteómica , Humanos , Apoproteína(a) , Péptidos/química , Lipoproteína(a)
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA