Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiology ; 247(2): 381-90, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18430873

RESUMEN

PURPOSE: To prospectively determine in a fetal pig model whether diagnostic performance comparable to that of high-detail screen-film imaging can be achieved with computed radiography for the detection of simulated classic metaphyseal lesions (CMLs), by using Faxitron digital images as the reference standard, and whether radiation dose reduction is possible. MATERIALS AND METHODS: This study was granted exempt status by the institutional review board and the animal care and use committee. Fractures simulating the CML were produced in distal femurs of 20 deceased fetal pigs. Twenty normal femurs served as control femurs. Femurs were imaged with a standard single-side-read 100-microm pixel sampling imaging plate (IP), a high-resolution dual-side-read 50-microm pixel sampling IP, and a high-detail screen-film imaging system. Eight tube current-time product settings (0.5-10.0 mAs) and two tube voltage selections (56 and 70 kVp) were employed. Two pediatric radiologists evaluated 920 images for fracture by using a five-point Likert scale. Area under the receiver operating characteristic curve (A(z)) values for the imaging systems were compared by using nonparametric chi(2) tests (all P < .05). RESULTS: For pooled rater data, performance of computed radiography was comparable to that of screen-film imaging, and superior performance (P = .04) was achieved with the more experienced rater. The A(z) value tended to increase as the tube current-time product setting was increased. Within each system, there was no significant difference in A(z) values for all images obtained at 56 and 70 kVp (dual-side-read IP, P = .63; single-side-read IP, P = .25; screen-film imaging system, P = .5). At 56 kVp, a dose reduction of up to 69% was achieved, and accuracy of computed radiography was comparable to that of screen-film imaging. CONCLUSION: Findings in this study suggest that computed radiography can replace screen-film imaging in the detection of CMLs and may permit dose reduction.


Asunto(s)
Fracturas del Fémur/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Pantallas Intensificadoras de Rayos X , Animales , Modelos Animales de Enfermedad , Feto , Estudios Prospectivos , Curva ROC , Dosis de Radiación , Porcinos
2.
Radiol Clin North Am ; 55(4): 767-784, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28601179

RESUMEN

Pediatric urinary system neoplasms are a diverse group of tumors that frequently overlap in their clinical and radiologic features. By contrast, the histopathologic classification and treatment of these entities have become increasingly refined, resulting in improved outcomes, with the overall survival of Wilms tumors now exceeding 90%. Significantly, many contemporary protocols rely on radiologic diagnosis in the absence of tissue confirmation. This review article provides up-to-date clinical, epidemiologic, and imaging findings of pediatric urinary system neoplasms and their mimics frequently encountered in daily clinical practice.


Asunto(s)
Diagnóstico por Imagen/métodos , Neoplasias Urológicas/diagnóstico por imagen , Niño , Preescolar , Diagnóstico Diferencial , Humanos , Lactante , Recién Nacido , Neoplasias Urológicas/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA