Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Emerg Infect Dis ; 30(1): 159-162, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38063084

RESUMEN

Studies suggest that central venous catheter bloodstream infections (BSIs) increased during the COVID-19 pandemic. We investigated catheter-related BSIs in Switzerland and found peripheral venous catheter (PVC) BSI incidence increased during 2021-2022 compared with 2020. These findings should raise awareness of PVC-associated BSIs and prompt inclusion of PVC BSIs in surveillance systems.


Asunto(s)
Bacteriemia , COVID-19 , Cateterismo Periférico , Infección Hospitalaria , Sepsis , Humanos , Suiza/epidemiología , Pandemias , Cateterismo Periférico/efectos adversos , COVID-19/epidemiología , COVID-19/complicaciones , Sepsis/etiología , Catéteres/efectos adversos , Infección Hospitalaria/epidemiología , Bacteriemia/epidemiología , Bacteriemia/complicaciones
2.
Clin Microbiol Infect ; 30(4): 548-551, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38142893

RESUMEN

OBJECTIVES: Short-term peripheral venous catheter-associated bloodstream infections (PVC-associated BSI) are disregarded in the literature because of their relatively low incidence. No data are available on the association between PVC diameter size and the risk of PVC-associated BSI. METHODS: Using a prospective database, we performed an observational study at the University of Geneva Hospitals from 1 January 2020 to 31 December 2021, including all patients with a PVC. We used univariable and multivariable marginal Cox regression models for clustered data to investigate the association between catheter size and PVC-associated BSI. The main variable of interest 'catheter size' was forced into our multivariable models. Confounders, which are thought to influence the risk of PVC-associated BSI, were used as adjustment factors. RESULTS: A total of 206 804 PVCs were included. In all, 10 806 of 201 413 (5.4%), 80 274 of 201 413 (39.9%), 93 047 of 201 413 (46.2%) and 17 286 of 201 413 (8.6%) PVCs measured ≤16G, 18G, 20G and ≥22G, respectively. The univariable analysis showed that diameters of ≤16G were significantly associated with a higher risk of PVC-associated BSI (hazard ratio [HR] 4.52, 95% CI, 1.14-18.00). Multivariable models confirmed these results (HR 4.65, 95% CI, 1.19-18.20). Sensitivity analyses including PVC inserted only in 2021 (HR 4.80, 95% CI, 1.21-19.10), for dwell time >2 days (HR 3.67, 95% CI, 0.92-14.65) and only in adults (HR 3.97, 95% CI, 0.97-15.39) showed similar results. DISCUSSION: Larger PVC size may increase the risk of PVC-associated BSI. Diameter size should be considered when selecting PVCs to reduce the burden of PVC-associated BSI.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Sepsis , Adulto , Humanos , Cateterismo Periférico/efectos adversos , Catéteres , Hospitales , Incidencia , Infecciones Relacionadas con Catéteres/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA