Mol Genet Metab ; 142(1): 108455, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38531184

RESUMEN

Creatine transporter deficiency has been described with normal or uninformative levels of creatine and creatinine in plasma, while urine has been the preferred specimen type for biochemical diagnosis. We report a cohort of untreated patients with creatine transporter deficiency and abnormal plasma creatine panel results, characterized mainly by markedly decreased plasma creatinine. We conclude that plasma should be considered a viable specimen type for the biochemical diagnosis of this disorder, and abnormal results should be followed up with further confirmatory testing.


Asunto(s)
Encefalopatías Metabólicas Innatas , Creatina , Creatina/deficiencia , Creatinina , Discapacidad Intelectual Ligada al Cromosoma X , Proteínas de Transporte de Neurotransmisores en la Membrana Plasmática , Proteínas de Transporte de Neurotransmisores en la Membrana Plasmática/deficiencia , Humanos , Creatina/sangre , Creatina/orina , Creatinina/sangre , Creatinina/orina , Proteínas de Transporte de Neurotransmisores en la Membrana Plasmática/genética , Proteínas de Transporte de Neurotransmisores en la Membrana Plasmática/sangre , Masculino , Femenino , Discapacidad Intelectual Ligada al Cromosoma X/genética , Discapacidad Intelectual Ligada al Cromosoma X/sangre , Discapacidad Intelectual Ligada al Cromosoma X/diagnóstico , Niño , Preescolar , Proteínas del Tejido Nervioso/genética , Proteínas del Tejido Nervioso/sangre , Proteínas del Tejido Nervioso/deficiencia , Lactante , Adolescente , Proteínas de Transporte de Membrana/genética , Proteínas de Transporte de Membrana/deficiencia , Proteínas de Transporte de Membrana/sangre , Adulto
2.
Genet Med ; 22(6): 1108-1118, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32089546

RESUMEN

PURPOSE: Newborn screening (NBS) for Krabbe disease (KD) is performed by measurement of galactocerebrosidase (GALC) activity as the primary test. This revealed that GALC activity has poor specificity for KD. Psychosine (PSY) was proposed as a disease marker useful to reduce the false positive rate for NBS and for disease monitoring. We report a highly sensitive PSY assay that allows identification of KD patients with minimal PSY elevations. METHODS: PSY was extracted from dried blood spots or erythrocytes with methanol containing d5-PSY as internal standard, and measured by liquid chromatography-tandem mass spectrometry. RESULTS: Analysis of PSY in samples from controls (N = 209), GALC pseudodeficiency carriers (N = 55), GALC pathogenic variant carriers (N = 27), patients with infantile KD (N = 26), and patients with late-onset KD (N = 11) allowed for the development of an effective laboratory screening and diagnostic algorithm. Additional longitudinal measurements were used to track therapeutic efficacy of hematopoietic stem cell transplantion (HSCT). CONCLUSION: This study supports PSY quantitation as a critical component of NBS for KD. It helps to differentiate infantile from later onset KD variants, as well as from GALC variant and pseudodeficiency carriers. Additionally, this study provides further data that PSY measurement can be useful to monitor KD progression before and after treatment.


Asunto(s)
Leucodistrofia de Células Globoides , Psicosina , Pruebas con Sangre Seca , Galactosilceramidasa/genética , Humanos , Recién Nacido , Leucodistrofia de Células Globoides/diagnóstico , Leucodistrofia de Células Globoides/genética , Tamizaje Neonatal
3.
Mol Genet Metab ; 130(4): 247-254, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32546364

RESUMEN

BACKGROUND: The prognosis of patients with Hereditary Tyrosinemia Type 1 (HT-1) has greatly improved with early detection through newborn screening and the introduction of nitisinone (NTBC) therapy. A recent guideline calls for periodic monitoring of biochemical markers and NTBC levels to tailor treatment; however, this is currently only achieved through a combination of clinical laboratory tests. We developed a multiplexed assay measuring relevant amino acids, succinylacetone (SUAC), and NTBC in dried blood spots (DBS) to facilitate treatment monitoring. METHODS: Tyrosine, phenylalanine, methionine, NTBC and SUAC were eluted from DBS with methanol containing internal standards for each analyte and analyzed by liquid chromatography tandem mass spectrometry over 6.5 min in the multiple reaction monitoring positive mode. RESULTS: Pre-analytical and analytical factors were studied and demonstrated a reliable assay. Chromatography resolved an unknown substance that falsely elevates SUAC concentrations and was present in all samples. To establish control and disease ranges, the method was applied to DBS collected from controls (n = 284) and affected patients before (n = 2) and after initiation of treatment (n = 29). In the treated patients SUAC concentrations were within the normal range over a wide range of NTBC levels. CONCLUSIONS: This assay enables combined, accurate measurement of revelevant metabolites and NTBC in order to simplify treatment monitoring of patients with HT-1. In addition, the use of DBS allows for specimen collection at home to facilitate more standardization in relation to drug and dietary treatment.


Asunto(s)
Aminoácidos/sangre , Biomarcadores/sangre , Ciclohexanonas/sangre , Heptanoatos/sangre , Laboratorios/normas , Nitrobenzoatos/sangre , Tirosinemias/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Pronóstico , Estándares de Referencia , Manejo de Especímenes , Tirosinemias/sangre , Tirosinemias/genética , Adulto Joven
4.
Mol Genet Metab ; 129(2): 106-110, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31753749

RESUMEN

PURPOSE: To describe an efficient and effective multiplex screening strategy for sulfatide degradation disorders and mucolipidosis type II/III (MLII/III) using 3 mL of urine. METHODS: Glycosaminoglycans were analyzed by liquid chromatography-tandem mass spectrometry. Matrix assisted laser desorption/ionization-time of flight tandem mass spectrometry was used to identify free oligosaccharides and identify 22 ceramide trihexosides and 23 sulfatides, which are integrated by 670 calculated ratios. Collaborative Laboratory Integrated Reports (CLIR; https://clir.mayo.edu) was used for post-analytical interpretation of the complex metabolite profile and to aid in the differential diagnosis of abnormal results. RESULTS: Multiplex analysis was performed on 25 sulfatiduria case samples and compiled with retrospective data from an additional 15 cases revealing unique patterns of biomarkers for each disorder of sulfatide degradation (MLD, MSD, and Saposin B deficiency) and for MLII/III, thus allowing the formulation of a novel algorithm for the biochemical diagnosis of these disorders. CONCLUSIONS: Comprehensive and integrated urine screening could be very effective in the initial workup of patients suspected of having a lysosomal disorder as it covers disorders of sulfatide degradation and narrows down the differential diagnosis in patients with elevated glycosaminoglycans.


Asunto(s)
Glicosaminoglicanos/orina , Enfermedades por Almacenamiento Lisosomal/diagnóstico , Enfermedades por Almacenamiento Lisosomal/orina , Mucolipidosis/diagnóstico , Sulfoglicoesfingolípidos/orina , Adolescente , Adulto , Algoritmos , Biomarcadores/orina , Niño , Preescolar , Cromatografía Liquida , Femenino , Ensayos Analíticos de Alto Rendimiento , Humanos , Lactante , Masculino , Persona de Mediana Edad , Mucolipidosis/orina , Estudios Retrospectivos , Espectrometría de Masas en Tándem , Adulto Joven
5.
Mol Genet Metab ; 124(2): 109-113, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29703588

RESUMEN

Current newborn screening (NBS) for urea cycle disorders (UCD) is incomplete as only distal UCDs are included in most NBS programs by measuring elevated amino acid concentrations. NBS for the proximal UCDs involves the detection in NBS spots of low citrulline values, a finding which is often overlooked because it is considered to be inadequate. We retrospectively analyzed NBS blood spots from known UCD patients comparing the utility of the Region 4 Stork (R4S) interpretive tools to conventional cutoff based interpretation. This study shows the utility of R4S tools in detecting all UCDs, and provides evidence to support the nomination to add proximal UCDs to the recommended uniform screening panel.


Asunto(s)
Citrulina/sangre , Pruebas con Sangre Seca/métodos , Tamizaje Neonatal/normas , Guías de Práctica Clínica como Asunto/normas , Trastornos Innatos del Ciclo de la Urea/sangre , Trastornos Innatos del Ciclo de la Urea/diagnóstico , Femenino , Humanos , Recién Nacido , Masculino , Proyectos Piloto , Estudios Prospectivos , Estudios Retrospectivos
6.
Int J Neonatal Screen ; 6(2): 33, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33073028

RESUMEN

The expansion of the recommend uniform screening panel to include more than 50 primary and secondary target conditions has resulted in a substantial increase of false positive results. As an alternative to subjective manipulation of cutoff values and overutilization of molecular testing, here we describe the performance outcome of an algorithm for disorders of methionine, cobalamin, and propionate metabolism that includes: (1) first tier screening inclusive of the broadest available spectrum of markers measured by tandem mass spectrometry; (2) integration of all results into a score of likelihood of disease for each target condition calculated by post-analytical interpretive tools created byCollaborative Laboratory Integrated Reports (CLIR), a multivariate pattern recognition software; and (3) further evaluation of abnormal scores by a second tier test measuring homocysteine, methylmalonic acid, and methylcitric acid. This approach can consistently reduce false positive rates to a <0.01% level, which is the threshold of precision newborn screening. We postulate that broader adoption of this algorithm could lead to substantial savings in health care expenditures. More importantly, it could prevent the stress and anxiety experienced by many families when faced with an abnormal newborn screening result that is later resolved as a false positive outcome.

7.
Int J Neonatal Screen ; 6(1): 10, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-33073008

RESUMEN

Enzyme-based newborn screening for Mucopolysaccharidosis type I (MPS I) has a high false-positive rate due to the prevalence of pseudodeficiency alleles, often resulting in unnecessary and costly follow up. The glycosaminoglycans (GAGs), dermatan sulfate (DS) and heparan sulfate (HS) are both substrates for α-l-iduronidase (IDUA). These GAGs are elevated in patients with MPS I and have been shown to be promising biomarkers for both primary and second-tier testing. Since February 2016, we have measured DS and HS in 1213 specimens submitted on infants at risk for MPS I based on newborn screening. Molecular correlation was available for 157 of the tested cases. Samples from infants with MPS I confirmed by IDUA molecular analysis all had significantly elevated levels of DS and HS compared to those with confirmed pseudodeficiency and/or heterozygosity. Analysis of our testing population and correlation with molecular results identified few discrepant outcomes and uncovered no evidence of false-negative cases. We have demonstrated that blood spot GAGs analysis accurately discriminates between patients with confirmed MPS I and false-positive cases due to pseudodeficiency or heterozygosity and increases the specificity of newborn screening for MPS I.