Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Pediatr Radiol ; 53(11): 2180-2187, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37599288

RESUMEN

Magnetic resonance imaging (MRI) assessment of hepatic vasculature can be challenging in the setting of liver disease and liver lesions. The widely used hepatobiliary contrast agent gadoxetate is an extracellular contrast agent that provides excellent soft tissue characterization but has limitations as a vascular contrast agent. Ferumoxytol is an iron oxide nanoparticle with superparamagnetic properties that can be used as blood pool contrast agent to provide dedicated vascular assessment. We provide a detailed protocol for evaluation of pediatric liver vasculature using ferumoxytol, after imaging of the parenchyma with gadoxetate. We provide multiple examples and discuss practical considerations when incorporating ferumoxytol into practice.

2.
Pediatr Radiol ; 53(13): 2597-2607, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37882844

RESUMEN

BACKGROUND: Four-dimensional flow (4D flow) MRI has become a clinically utilized cardiovascular flow assessment tool. However, scans can be lengthy and may require anesthesia in younger children. Adding compressed sensing can decrease scan time, but its impact on hemodynamic data accuracy needs additional assessment. OBJECTIVE: To compare 4D flow hemodynamics acquired with and without compressed sensing. MATERIALS AND METHODS: Twenty-seven patients (median age: 13 [IQR: 9.5] years) underwent conventional and compressed sensing cardiovascular 4D flow following informed consent. Conventional 4D flow was performed using parallel imaging and an acceleration factor of 2. Compressed sensing 4D flow was performed with an acceleration factor of 7.7. Regions of interest were placed to compare flow parameters in the ascending aorta and main pulmonary artery. Paired Student's t-tests, Wilcoxon signed-rank tests, Bland-Altman plots, and intraclass correlation coefficients were conducted. A P-value of < 0.05 was considered statistically significant. RESULTS: Mean scan acquisition time was reduced by 59% using compressed sensing (3.4 vs. 8.2 min, P < 0.001). Flow quantification was similar for compressed sensing and conventional 4D flow for the ascending aorta net flow: 47 vs. 49 ml/beat (P = 0.28); forward flow: 49 vs. 50 ml/beat (P = 0.07), and main pulmonary artery net flow: 49 vs. 51 ml/beat (P = 0.18); forward flow: 50 vs. 55 ml/beat (P = 0.07). Peak systolic velocity was significantly underestimated by compressed sensing 4D flow in the ascending aorta: 114 vs. 128 cm/s (P < 0.001) and main pulmonary artery: 106 vs. 112 cm/s (P = 0.02). CONCLUSION: For both the aorta and main pulmonary artery, compressed sensing 4D flow provided equivalent net and forward flow values compared to conventional 4D flow but underestimated peak systolic velocity. By reducing scan time, compressed sensing 4D flow may decrease the need for anesthesia and increase scanner output without significantly compromising data integrity.


Asunto(s)
Cardiopatías , Arteria Pulmonar , Humanos , Niño , Adulto Joven , Adolescente , Arteria Pulmonar/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Reproducibilidad de los Resultados
3.
J Comput Chem ; 43(31): 2072-2083, 2022 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-36169240

RESUMEN

Polyethyleneimine (PEI), one of the non-viral vectors of great interest for gene delivery, was investigated at all-atom level, with particular emphasis on its branched form. We report the extension of our previously published CHARMM force field (FF) for linear PEI, with parameters optimized specifically for branched configurations. A new residue type for the branch connector is introduced and the charges and bonded parameters are derived from ab initio calculations based on a model polymer. The new FF is validated by extensive molecular dynamics simulations of solvated branched PEIs of various protonation fractions and branch lengths. The gyration radii, end-to-end distances, and diffusion coefficients are compared with results for linear PEIs of similar molecular weights and protonation patterns. Solvated complexes of DNA with (linear/branched) PEI were also investigated to determine favorable attachment conformations. The parametrized atomistic force field is suitable for simulations of PEI with arbitrary branching pattern, protonation, and size, and is expected to provide relevant insights regarding optimal conditions for DNA-PEI complex formation.


Asunto(s)
Simulación de Dinámica Molecular , Polietileneimina , ADN/química , Polietileneimina/química , Polímeros
4.
Catheter Cardiovasc Interv ; 96(3): 633-637, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32343465

RESUMEN

Covered stents have a continually expanding spectrum of applications for patients with congenital heart disease. Here we report use of covered stents to successfully perform a first-in-human percutaneous biventricular conversion of a 1.5 ventricle Glenn palliation in an adult born with pulmonary atresia. This case demonstrates that in patients considered borderline for biventricular repair, surgery can potentially be modified to promote growth of underdeveloped structures and setup for transcatheter biventricular conversion.


Asunto(s)
Procedimientos Endovasculares , Procedimiento de Fontan , Cardiopatías Congénitas/cirugía , Cuidados Paliativos , Síndrome de la Vena Cava Superior/terapia , Adulto , Procedimientos Endovasculares/instrumentación , Femenino , Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Hemodinámica , Humanos , Stents , Síndrome de la Vena Cava Superior/diagnóstico por imagen , Síndrome de la Vena Cava Superior/etiología , Síndrome de la Vena Cava Superior/fisiopatología , Resultado del Tratamiento
5.
Pediatr Radiol ; 49(2): 168-174, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30382320

RESUMEN

BACKGROUND: The meso-Rex bypass restores blood flow to the liver in patients with extrahepatic portal vein thrombosis. Stenosis occurs in some cases, causing the reappearance of portal hypertension. Complications such as thrombocytopenia present on a spectrum and there are currently no guidelines regarding a threshold for endovascular intervention. While Doppler ultrasound (US) is common for routine evaluation, magnetic resonance (MR) angiography with two-dimensional phase-contrast MRI (2-D PC-MRI) may improve the assessment of meso-Rex bypass function. OBJECTIVES: To determine the feasibility and utility of MR angiography with 2-D PC-MRI in evaluating children with meso-Rex bypass and to correlate meso-Rex bypass blood flow to markers of portal hypertension. MATERIALS AND METHODS: MR angiography and 2-D PC-MRI in meso-Rex bypass patients were retrospectively analyzed. Minimum bypass diameter was measured on MR angiography and used to calculate cross-sectional area. Meso-Rex bypass blood flow was measured using 2-D PC-MRI and divided by ascending aortic flow to quantify bypass flow relative to systemic circulation. Platelet and white blood cell counts were recorded. Correlation was performed between minimum bypass area, blood flow and clinical data. RESULTS: Twenty-five children (median age: 9.5 years) with meso-Rex bypass underwent MR angiography and 2-D PC-MRI. The majority of patients were referred to imaging given clinical concern for complications. Eighteen of the 25 patients demonstrated >50% narrowing of the bypass cross-sectional area. The mean platelet count in 19 patients was 127 K/µL. There was a significant correlation between minimum cross-sectional bypass area and bypass flow (rho=0.469, P=0.018) and between bypass flow and platelet counts (r=0.525, P=0.021). CONCLUSION: Two-dimensional PC-MRI can quantify meso-Rex bypass blood flow relative to total systemic flow. In a cohort of 25 children, bypass flow correlated to minimum bypass area and platelet count. Two-dimensional PC-MRI may be valuable alongside MR angiography to assess bypass integrity.


Asunto(s)
Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/cirugía , Angiografía por Resonancia Magnética/métodos , Vena Porta/diagnóstico por imagen , Vena Porta/cirugía , Injerto Vascular/métodos , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/cirugía , Técnicas de Imagen Sincronizada Cardíacas , Niño , Medios de Contraste , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Estudios Retrospectivos
7.
Eur Radiol ; 27(2): 832-840, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27193778

RESUMEN

OBJECTIVES: To determine the feasibility of 4D flow MRI for visualization and quantification of the portal venous haemodynamics in children and young adults. METHODS: 4D flow was performed in 28 paediatric patients (median age, 8.5 years; interquartile range, 5.2-16.5), 15 with non-operated native portal system and 13 with surgically created portal shunt. Image quality assessment for 3D flow visualization and flow pattern analyses was performed. Regional 4D flow peak velocity and net flow were compared with 2D-cine phase contrast MRI (2D-PC MR) in the post-surgical patients. RESULTS: Mean 3D flow visualization quality score was excellent (mean ± SD, 4.2 ± 0.9) with good inter-rater agreement (κ,0.67). Image quality in children aged >10 years was better than children ≤10 years (p < 0.05). Flow pattern was defined for portal, superior mesenteric, splenic veins and splenic artery in all patients. 4D flow and 2D-PC MR peak velocity and net flow were similar with good correlation (peak velocity: 4D flow 22.2 ± 9.1 cm/s and 2D-PC MR 25.2 ± 11.2 cm/s, p = 0.46; r = 0.92, p < 0.0001; net flow: 4D flow 9.5 ± 7.4 ml/s and 2D-PC MR 10.1 ± 7.3 ml/s, p = 0.65; r = 0.81, p = 0.0007). CONCLUSIONS: 4D flow MRI is feasible and holds promise for the comprehensive 3D visualization and quantification of portal venous flow dynamics in children and young adults. KEY POINTS: • 4D flow MRI is feasible in children and young adults. • 4D flow MRI has the ability to non-invasively characterize portal haemodynamics. • Image quality of 4D flow MRI is better is older children. • 4D flow MRI can accurately quantify portal flow compared to 2D-cine PC MRI.


Asunto(s)
Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética/métodos , Venas Mesentéricas/diagnóstico por imagen , Vena Porta/diagnóstico por imagen , Arteria Esplénica/diagnóstico por imagen , Vena Esplénica/diagnóstico por imagen , Adolescente , Velocidad del Flujo Sanguíneo , Niño , Preescolar , Estudios de Factibilidad , Femenino , Hemodinámica , Humanos , Imagenología Tridimensional/métodos , Masculino , Derivación Portosistémica Quirúrgica , Estudios Prospectivos
8.
AJR Am J Roentgenol ; 205(5): 1114-20, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26496560

RESUMEN

OBJECTIVE: The objective of our study was to determine the adverse reaction rate associated with the administration of blood pool contrast material in children and young adults. MATERIALS AND METHODS: A review of the MRI and pharmacy databases identified all patients who received gadofosveset trisodium from October 1, 2011, to June 30, 2014. Patients were classified as having been anesthetized or not anesthetized for the MRI examinations. A review of the electronic medical records identified adverse reactions recorded within 24 hours of contrast administration. The adverse reactions were graded as mild, moderate, or severe. Risk ratios were calculated between the adverse reaction rate experienced by anesthetized patients and that experience by nonanesthetized patients. RESULTS: During the study period, 626 patients (mean age, 11.7 years) received 711 doses of gadofosveset trisodium; 137 adverse reactions were recorded, which yields a 19.3% (137/711) adverse reaction rate. There were 115 adverse reactions experienced by 367 anesthetized patients (31.3%): 93.0% (107/115) were mild and 7.0% (8/115) were moderate. The remaining 22 adverse reactions were experienced by 344 (6.4%) nonanesthetized patients, and 90.9% (20/22) were mild. Three nonanesthetized patients had allergiclike reactions; of these allergiclike reactions, one was mild and two were severe for a severe allergiclike reaction rate of 0.28% (2/711). Severe allergiclike reactions were treated without any adverse outcomes. Anesthetized patients were 5.7 times more likely to experience an adverse event than nonanesthetized patients; most reactions in anesthetized patients were seen after the administration of anesthesia alone. CONCLUSION: Most reactions after gadofosveset trisodium administration in children and young adults are mild; however, severe allergiclike reactions occur, so policies must be in place to treat patients with adverse reactions when using this contrast agent. These data may be useful to centers considering administering gadofosveset trisodium to pediatric patients.


Asunto(s)
Medios de Contraste/efectos adversos , Gadolinio/efectos adversos , Imagen por Resonancia Magnética , Compuestos Organometálicos/efectos adversos , Adolescente , Sistemas de Registro de Reacción Adversa a Medicamentos , Niño , Preescolar , Medios de Contraste/administración & dosificación , Femenino , Gadolinio/administración & dosificación , Humanos , Lactante , Recién Nacido , Masculino , Compuestos Organometálicos/administración & dosificación , Estudios Retrospectivos , Seguridad , Adulto Joven
9.
Artículo en Inglés | MEDLINE | ID: mdl-24725717

RESUMEN

The majority of patients having surgical intervention for a vascular ring have resolution of their symptoms. However, 5% to 10% of these patients develop recurrent symptoms related either to airway or esophageal compression and may require reoperation. In our series of 300 patients with vascular rings, we performed a reoperation on 26 patients, not all of whom were originally operated on at our institution. The four primary indications for reoperation were Kommerell diverticulum (n = 18), circumflex aorta (n = 2), residual scarring (n = 2), and tracheobronchomalacia requiring aortopexy (n = 4). All patients undergoing reoperation have had preoperative evaluation with bronchoscopy and computed tomographic scanning (CT) with 3-dimensional reconstruction. Patients with dysphagia have had a barium esophagram and esophagoscopy. Patients with a Kommerell diverticulum have undergone resection of the diverticulum and transfer of the left subclavian artery to the left carotid artery. The aortic uncrossing procedure has been used in patients with a circumflex aorta. Aortopexy has been used to treat anterior compression of the trachea by the aorta. Results of these reinterventions have been successful in nearly all cases. Lessons learned from these reoperations can be applied to prevent the need for reoperation by properly selecting the correct initial operation. A dedicated team caring for these children consisting of medical imaging, otolaryngology, cardiovascular-thoracic surgery, and critical care is imperative.


Asunto(s)
Aorta Torácica , Enfermedades de la Aorta/congénito , Enfermedades de la Aorta/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Divertículo/congénito , Divertículo/cirugía , Cardiopatías Congénitas/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Niño , Preescolar , Divertículo/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Lactante , Reoperación , Tomografía Computarizada por Rayos X
10.
Pediatr Radiol ; 44(3): 265-73, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24306733

RESUMEN

BACKGROUND: Phase contrast magnetic resonance imaging (MRI) is a powerful tool for evaluating vessel blood flow. Inherent errors in acquisition, such as phase offset, eddy currents and gradient field effects, can cause significant inaccuracies in flow parameters. These errors can be rectified with the use of background correction software. OBJECTIVE: To evaluate the performance of an automated phase contrast MRI background phase correction method in children and young adults undergoing cardiac MR imaging. MATERIALS AND METHODS: We conducted a retrospective review of patients undergoing routine clinical cardiac MRI including phase contrast MRI for flow quantification in the aorta (Ao) and main pulmonary artery (MPA). When phase contrast MRI of the right and left pulmonary arteries was also performed, these data were included. We excluded patients with known shunts and metallic implants causing visible MRI artifact and those with more than mild to moderate aortic or pulmonary stenosis. Phase contrast MRI of the Ao, mid MPA, proximal right pulmonary artery (RPA) and left pulmonary artery (LPA) using 2-D gradient echo Fast Low Angle SHot (FLASH) imaging was acquired during normal respiration with retrospective cardiac gating. Standard phase image reconstruction and the automatic spatially dependent background-phase-corrected reconstruction were performed on each phase contrast MRI dataset. Non-background-corrected and background-phase-corrected net flow, forward flow, regurgitant volume, regurgitant fraction, and vessel cardiac output were recorded for each vessel. We compared standard non-background-corrected and background-phase-corrected mean flow values for the Ao and MPA. The ratio of pulmonary to systemic blood flow (Qp:Qs) was calculated for the standard non-background and background-phase-corrected data and these values were compared to each other and for proximity to 1. In a subset of patients who also underwent phase contrast MRI of the MPA, RPA, and LPA a comparison was made between standard non-background-corrected and background-phase-corrected mean combined flow in the branch pulmonary arteries and MPA flow. All comparisons were performed using the Wilcoxon sign rank test (α = 0.05). RESULTS: Eighty-five children and young adults (mean age 14 years; range 10 days to 32 years) met the criteria for inclusion. Background-phase-corrected mean flow values for the Ao and MPA were significantly lower than those for non-background-corrected standard Ao (P = 0.0004) and MPA flow values (P < 0.0001), respectively. However, no significant difference was seen between the standard non-background (P = 0.295) or background-phase-corrected (P = 0.0653) mean Ao and MPA flow values. Neither the mean standard non-background-corrected (P = 0.408) nor the background-phase-corrected (P = 0.0684) Qp:Qs was significantly different from 1. However in the 27 patients with standard non-background-corrected data, the difference between the Ao and MPA flow values was greater than 10%. There were 19 patients with background-phase-corrected data in which the difference between the Ao and MPA flow values was greater than 10%. In the subset of 43 patients who underwent MPA and branch pulmonary artery phase contrast MRI, the sum of the standard non-background-corrected mean RPA and LPA flow values was significantly different from the standard non-background-corrected mean MPA flow (P = 0.0337). The sum of the background-phase-corrected mean RPA and LPA flow values was not significantly different from the background-phase-corrected mean MPA flow value (P = 0.1328), suggesting improvement in pulmonary artery flow calculations using background-phase-correction. CONCLUSION: Our data suggest that background phase correction of phase contrast MRI data does not significantly change Qp:Qs quantification, and there are residual errors in expected Qp:Qs quantification despite background phase correction. However the use of background phase correction does improve quantification of MPA flow relative to combined RPA and LPA flow. Further work is needed to validate these findings in other patient populations, using other MRI units, and across vendors.


Asunto(s)
Estenosis de la Válvula Aórtica/patología , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Estenosis de la Válvula Pulmonar/patología , Adolescente , Adulto , Algoritmos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
11.
J Magn Reson Imaging ; 37(1): 127-37, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22996419

RESUMEN

PURPOSE: To evaluate time-resolved magnetic resonance angiography (TR-MRA) of the pulmonary venous circulation using the time-resolved angiography with interleaved stochastic trajectories (TWIST) method and compare it with the more commonly used conventional contrast-enhanced magnetic resonance angiography (CE-MRA) approach in atrial fibrillation patients referred for preablation pulmonary vein mapping. MATERIALS AND METHODS: This study was approved by the Institutional Review Board. Twenty-six patients (15 males; age 59.6 ± 12.7 years) referred for preablation pulmonary vein mapping underwent both conventional CE-MRA and TR-MRA with TWIST. Imaging was performed on a 1.5 T (Magnetom Avanto, Siemens Healthcare, Erlangen, Germany) MRI scanner. Source partition and maximum intensity projection (MIP) images were evaluated retrospectively. For quantitative analysis, pulmonary vein ostium orthogonal dimensions were measured using double oblique multiplanar reformatting. The results were analyzed using paired t-tests, Lin's concordance correlation coefficient, and Bland-Altman plots. For qualitative analysis, both source partition images and MIP images were assessed by two observers (A.P. and M.G.). The presence of common ostiums or accessory veins was recorded and analyzed using unweighted Cohen's kappa. Pulmonary vein conspicuity was scored on a scale of 1-4 (1 = poor, 2 = fair, 3 = good, 4 = excellent) and analyzed using paired t-tests, intraclass correlation coefficients, and quadratic weighted kappa statistics. RESULTS: Orthogonal venous diameters were comparable for both TR-MRA and conventional CE-MRA (1.34 ± 0.37 vs. 1.38 cm ± 0.36, respectively). Results of paired t-tests, Lin's concordance correlation coefficient, and Bland-Altman analysis revealed relatively close comparison between methods. The magnitude of the mean difference for any of the statistical comparisons did not exceed 0.10 cm. The visualization of variant pulmonary vein anatomy was very similar for both techniques. Agreement between techniques was determined to be "good" to "very good" (κ = 0.78-0.85). Conspicuity scores for each pulmonary vein were also very close. Paired t-tests, intraclass correlation coefficients, and quadratic weighted kappa statistics all revealed strong agreement between methods. CONCLUSION: TR-MRA using TWIST produces comparable anatomic images and pulmonary venous dimensions to the more widely used CE-MRA technique. Additionally, the TWIST technique improves arterio-venous separation, does not need exact bolus timing, requires less gadolinium, and gives additional information on vein perfusion.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/patología , Angiografía por Resonancia Magnética/métodos , Flebografía/métodos , Venas Pulmonares/patología , Adulto , Anciano , Cardiología/métodos , Cateterismo , Diagnóstico por Imagen/métodos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Perfusión , Procesos Estocásticos , Factores de Tiempo
12.
J Magn Reson Imaging ; 38(6): 1531-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23564638

RESUMEN

PURPOSE: To evaluate two nonenhanced MRA methods: quiescent-interval single-shot (QISS) and Native SPACE (NATIVE = Non-contrast Angiography of the Arteries and Veins; SPACE = Sampling Perfection with Application Optimized Contrast by using different flip angle Evolution), using contrast-enhanced MR angiography (CEMRA) as a reference standard. MATERIALS AND METHODS: Twenty patients (14 male; mean, 69.3 years old) referred for lower extremity MRA were recruited in a HIPAA-compliant prospective study. QISS and Native SPACE of the lower extremities were performed at 1.5 Tesla with a hybrid dual-injection contrast-enhanced MRA as reference. Image quality and stenosis severity were assessed in segments by two blinded radiologists. Methods were compared with logistic regression for correlated data for diagnostic accuracy. RESULTS: Of 496 arterial segments, 24 were considered nondiagnostic on the Native SPACE images. There were no QISS or CEMRA imaging segments considered to be nondiagnostic. Image quality was significantly higher for QISS than for Native SPACE. QISS stenosis sensitivity (84.9%) was not significantly different from Native SPACE (87.3%). QISS had better specificity (95.6%) than Native SPACE (87.0%), P = 0.0041. In comparison with QISS, Native SPACE proved less robust for imaging of the abdominal and pelvic segments. CONCLUSION: Native SPACE and QISS were sensitive for hemodynamically significant stenosis in this pilot study. QISS NEMRA demonstrated superior specificity and image quality, and was more robust in the abdominal and pelvic regions.


Asunto(s)
Arteriopatías Oclusivas/patología , Interpretación de Imagen Asistida por Computador/métodos , Isquemia/patología , Pierna/irrigación sanguínea , Angiografía por Resonancia Magnética/métodos , Enfermedad Arterial Periférica/patología , Anciano , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Pierna/patología , Masculino , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Diagnostics (Basel) ; 13(3)2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36766668

RESUMEN

Esophageal stroke, also known as acute esophageal necrosis or Gurvits syndrome, is an entity that has gained more and more recognition in the last two decades. It is also named "black esophagus" because of striking black discoloration of the esophageal mucosa, with an abrupt transition to normal mucosa at the gastroesophageal junction. Its most common clinical presentation is represented by upper gastrointestinal bleeding and esophagogastroduodenoscopy is the main diagnostic tool. Among the etiopathogenetic and multiple predisposing factors described are hypovolemia, shock state, ischemia, congestive heart failure, acute renal failure, infections, trauma, and diabetes mellitus. Current management of this condition consists of treating the underlying pathology, nil per os, and antacid administration in uncomplicated cases. Although most of the cases have favorable prognosis, complications such as pneumomediastinum or esophageal stricture may occur and fatal cases are a consequence of underlying comorbidities.

14.
Diagnostics (Basel) ; 13(17)2023 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-37685385

RESUMEN

This study focused on the potential risks of radiofrequency-induced heating of cardiac implantable electronic devices (CIEDs) in children and adults with epicardial and endocardial leads of varying lengths during cardiothoracic MRI scans. Infants and young children are the primary recipients of epicardial CIEDs, though the devices have not been approved as MR conditional by the FDA due to limited data, leading to pediatric hospitals either refusing the MRI service to most pediatric CIED patients or adopting a scan-all strategy based on results from adult studies. The study argues that risk-benefit decisions should be made on an individual basis. We used 120 clinically relevant epicardial and endocardial device configurations in adult and pediatric anthropomorphic phantoms to determine the temperature rise during RF exposure at 1.5 T. The results showed that there was significantly higher RF heating of epicardial leads than endocardial leads in the pediatric phantom, but not in the adult phantom. Additionally, body size and lead length significantly affected RF heating, with RF heating up to 12 °C observed in models based on younger children with short epicardial leads. The study provides evidence-based knowledge on RF-induced heating of CIEDs and highlights the importance of making individual risk-benefit decisions when assessing the potential risks of MRI scans in pediatric CIED patients.

15.
Pediatr Blood Cancer ; 58(1): 98-100, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21721105

RESUMEN

Metastatic medullary thyroid carcinoma (MTC) is an aggressive malignancy with an extremely poor prognosis. Currently no effective conventional systemic therapies exist to treat pediatric MTC. We describe an adolescent female with newly diagnosed MEN2B syndrome who presented with advanced stage metastatic MTC and demonstrated a partial transient response to sorafenib monotherapy. This clinical result supports further research into the use of sorafenib in the treatment of pediatric MTC.


Asunto(s)
Antineoplásicos/uso terapéutico , Bencenosulfonatos/uso terapéutico , Carcinoma Medular/tratamiento farmacológico , Neoplasia Endocrina Múltiple Tipo 2b/tratamiento farmacológico , Piridinas/uso terapéutico , Neoplasias de la Tiroides/tratamiento farmacológico , Adolescente , Carcinoma Medular/etiología , Femenino , Humanos , Neoplasia Endocrina Múltiple Tipo 2b/complicaciones , Niacinamida/análogos & derivados , Compuestos de Fenilurea , Pronóstico , Sorafenib , Neoplasias de la Tiroides/etiología
16.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4014-4017, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36086095

RESUMEN

Patients with congenital heart defects, inherited arrhythmia syndromes, and congenital disorders of cardiac conduction often receive a cardiac implantable electronic device (CIED). At least 75% of patients with CIEDs will need magnetic resonance imaging (MRI) during their lifetime. In 2011, the US Food and Drug Administration approved the first MR-conditional CIEDs for patients with endocardial systems, in which leads are passed through the vein and affixed to the endocardium. The majority of children, however, receive an epicardial CIED, where leads are directly sewn to the epicardium. Unfortunately, an epicardial CIED is a relative contraindication to MRI due to the unknown risk of RF heating. In this work, we performed anthropomorphic phantom experiments to investigate differences in RF heating between endocardial and epicardial leads in both pediatric and adult-sized phantoms, where adult endocardial CIED was the control. Clinical Relevance-This work provides a quantitative comparison of MRI RF heating of epicardial and endocardial leads in pediatric and adult populations.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Adulto , Niño , Desfibriladores Implantables/efectos adversos , Electrónica , Endocardio/diagnóstico por imagen , Calefacción , Humanos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodos , Pericardio/diagnóstico por imagen
17.
Exp Ther Med ; 21(6): 604, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33936261

RESUMEN

This prospective study aimed to determine the manometric pattern and the prevalence of esophageal dysmotility in 79 morbidly obese patients selected for laparoscopic sleeve gastrectomy. After clinical evaluation and upper gastrointestinal endoscopy, high-resolution esophageal manometry was performed. The esophageal peristalsis, lower esophageal sphincter (LES) basal pressure, and LES relaxation were evaluated. Demographic data showed a predominance of females (55.70%) and both females and males were in the 5th decade of life. In addition, approximately 3/4 of the patients (78.48%) were from the urban zone. The mean body mass index of the patients was 46.40±6.0069 kg/m2, with a maximum of 61 kg/m2. The LES basal pressure was normal in 59.49% of the patients, with a mean value of 31.40±18.43 mmHg. LES basal hypertonia was observed in 26.58%, and LES hypotonia in 13.93% of patients; 46.84% (37 patients) had abnormal manometric findings: 24.05% (19 patients) had EGJ outflow obstruction, 12.66% (10 patients) ineffective esophageal motility, 3.8% (3 patients) distal esophageal spasm, 3.8% (3 patients) Jackhammer esophagus, 2 cases were suggestive for type 2 achalasia but in asymptomatic patients. Ineffective esophageal motility was not associated with diabetes mellitus type 2 or erosive esophagitis according to our data. Hiatal hernia (HH) was manometrically diagnosed in 23 patients (29.11%). Preoperative high-resolution esophageal manometry in obese patients demonstrated a high prevalence of motility disorders, but in asymptomatic patients, thus in the future, we require more studies and larger cohorts to better appreciate the clinical impact.

18.
Exp Ther Med ; 22(1): 759, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34035856

RESUMEN

Portal vein thrombosis (PVT) is a frequent complication in cirrhotic patients, but it may also exist as a basic vascular condition even without any liver damage. Local and systemic factors play a significant role in the pathogenesis of PVT; yet, in practice, more than one factor may be identified. PVT can be considered a result of liver fibrosis and hepatic insufficiency. The JAK2 mutation has been accepted as a factor producing PVT. In general, the anticoagulants are recommended but this therapy should be used carefully in treating patients that associate coagulopathy or thrombocytopenia and esophageal varices. Acute PVT without bowel infarction has a good prognosis. In liver cirrhosis, the mortality due to hemorrhage is higher than in chronic PVT. Therefore, for the patients with PVT, the survival rate is decreased by 55% in two years, due to hepatic insufficiency. Regarding the treatment, LMWH (low molecular weight heparine) is the most utilized in patients with cirrhosis, non-malignancies, infections, or those who are awaiting a liver transplant. DOACs (direct-acting oral anticoagulants) may be used in the rest of the medical conditions, being safe and equal to LMWH.

19.
Rom J Intern Med ; 59(3): 296-302, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-33600675

RESUMEN

Introduction. Laparoscopic sleeve gastrectomy (LSG) is a popular weight loss surgery technique, but the impact on esophageal physiology and esophagogastric junction is still debatable. The aim of our study was to evaluate the manometric changes of the lower esophageal sphincter (LES) after LSG in order to indicate LES manometry pre- procedure. Methods. In a prospective study we evaluated clinically, with upper gastrointestinal endoscopy, and high-resolution esophageal manometry 45 morbidly obese patients before, and 6-12 months after LSG. Results. The BMI (body mass index) decreased from 46.28±5.79 kg/m2 to 32.28±4.65 kg/m2 postoperatively (p <0.01), with a reduction of ~14 kg/m2 of BMI, 39.9 (±11.9) kg body weight and 29.9 (± 6.2)% of the TWL (Total Weight Loss index), in a median interval of 7.9 months. Gastroesophageal reflux disease (GERD) prevalence increased from 17.8% to 31.1% postoperatively, with new GERD onset in 22.2%, but mild symptomatology (the median GERD-HRQL score increased from 1.56 to 2.84 points). Postoperatory reflux was associated with lower esophageal sphincter (LES) hypotonia, shortening of LES length and IIGP (increased intragastric pressure). Hiatal hernia repair rate was 17.8%, and proton pump inhibitor consumption 20%. After weight loss, the 10 cases of esophagitis discovered preoperatively cured, but 3 patients were diagnosed with de novo esophagitis. The prevalence of manometric dysmotility after LSG was 28.9%, lower than before surgery (44.4%). Conclusion. Even if GERD remains the main limitation of LSG, the high-resolution esophageal manometry has proved useful and should be implemented in morbidly obese evaluation protocol, to better select the bariatric procedure.


Asunto(s)
Esofagitis/epidemiología , Gastrectomía/efectos adversos , Reflujo Gastroesofágico/epidemiología , Laparoscopía , Obesidad Mórbida/cirugía , Adulto , Anciano , Índice de Masa Corporal , Femenino , Reflujo Gastroesofágico/etiología , Humanos , Masculino , Persona de Mediana Edad , Obesidad Mórbida/epidemiología , Prevalencia , Estudios Prospectivos , Pérdida de Peso
20.
Ann Thorac Surg ; 111(3): 980-986, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32437676

RESUMEN

BACKGROUND: Given recent reports of percutaneous closure of sinus venosus atrial septal defects, we reviewed our experience with surgical repair. Owing to the high incidence of arrhythmias with the two-patch technique, since 2001 we have used either one-patch repairs or the Warden procedure. METHODS: A retrospective review was performed of pediatric patients undergoing sinus venosus atrial septal defect repair at our institution from January 1, 1990, to July 1, 2018. Standard demographic data such as echocardiographic and cross-sectional imaging along with operative details and clinical echocardiographic outcomes were collected. RESULTS: The cohort included 144 patients with a median age of 4.3 years (interquartile range, 8.5). Inferior SVASD was present in 24 patients (17%). A single autologous untreated pericardial patch was used for 114 patients (79%), a two-patch technique for 20 patients (14%, last performed in 2000), and a Warden procedure in 10 patients (7%). Median length of stay was 4 days (interquartile range, 2). On echocardiogram follow-up, no patient had pulmonary vein stenosis. One patient who had the Warden procedure required a balloon dilation of the superior caval vein 2 years postoperatively and a stent 3 years later. Two-patch patients were substantially less likely to be in normal sinus rhythm (41%) on postoperative electrocardiograms compared with the other two techniques (81% one-patch and 89% Warden, P = .02). CONCLUSIONS: The great majority of patients with sinus venosus atrial septal defects can be successfully repaired with a single patch of autologous pericardium. We transitioned to using either a single pericardial patch or the Warden procedure, resulting in a higher frequency of normal sinus rhythm on postoperative electrocardiograms.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/normas , Angiografía por Tomografía Computarizada/métodos , Defectos del Tabique Interatrial/cirugía , Guías de Práctica Clínica como Asunto , Vena Cava Superior/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Niño , Preescolar , Ecocardiografía , Electrocardiografía , Femenino , Estudios de Seguimiento , Defectos del Tabique Interatrial/diagnóstico , Humanos , Masculino , Estudios Retrospectivos , Vena Cava Superior/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA