Anal Chem ; 87(12): 6265-70, 2015 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-25984969

RESUMEN

The determination of pharmacokinetic properties of drugs, such as the distribution coefficient (D) is a crucial measurement in pharmaceutical research. Surprisingly, the conventional (gold standard) technique used for D measurements, the shake-flask method, is antiquated and unsuitable for the testing of valuable and scarce drug candidates. Herein, we present a simple microfluidic platform for the determination of distribution coefficients using droplet-based liquid-liquid extraction. For simplicity, this platform makes use of gravity to enable phase separation for analysis and is 48 times faster and uses 99% less reagents than performing an equivalent measurement using the shake-flask method. Furthermore, the D measurements achieved in our platform are in good agreement with literature values measured using traditional shake-flask techniques. Since D is affected by volume ratios, we use the apparent acid dissociation constant, pK', as a proxy for intersystem comparison. Our platform determines a pK' value of 7.24 ± 0.15, compared to 7.25 ± 0.58 for the shake-flask method in our hands and 7.21 for the shake-flask method in the literature. Devices are fabricated using injection molding, the batchwise fabrication time is <2 min per device (at a cost of $1 U.S. per device), and the interdevice reproducibility is high.


Asunto(s)
Extracción Líquido-Líquido , Técnicas Analíticas Microfluídicas , Quinina/análisis , Técnicas Analíticas Microfluídicas/instrumentación , Tamaño de la Partícula , Propiedades de Superficie
2.
Lab Chip ; 15(11): 2445-51, 2015 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-25912610

RESUMEN

A miniaturised array of supercritical angle fluorescence (SAF) micro-optics embedded in a microfluidic chamber was fabricated by injection moulding. The fabricated chip could enhance the fluorescence signal around 46 times compared to a conventional microscope. Collection of the fluorescence signal from the SAF array is almost independent of the numerical aperture, and the limit of detection was improved 36-fold using a simple and inexpensive optical detection system.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Miniaturización/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Espectrometría de Fluorescencia/instrumentación , ADN , Sondas de ADN , Diseño de Equipo , Límite de Detección , Técnicas Analíticas Microfluídicas/métodos , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Espectrometría de Fluorescencia/métodos