Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Digit Imaging ; 30(2): 244-254, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28025731

RESUMEN

Volumetric analysis of the kidney parenchyma provides additional information for the detection and monitoring of various renal diseases. Therefore the purposes of the study were to develop and evaluate a semi-automated segmentation tool and a modified ellipsoid formula for volumetric analysis of the kidney in non-contrast T2-weighted magnetic resonance (MR)-images. Three readers performed semi-automated segmentation of the total kidney volume (TKV) in axial, non-contrast-enhanced T2-weighted MR-images of 24 healthy volunteers (48 kidneys) twice. A semi-automated threshold-based segmentation tool was developed to segment the kidney parenchyma. Furthermore, the three readers measured renal dimensions (length, width, depth) and applied different formulas to calculate the TKV. Manual segmentation served as a reference volume. Volumes of the different methods were compared and time required was recorded. There was no significant difference between the semi-automatically and manually segmented TKV (p = 0.31). The difference in mean volumes was 0.3 ml (95% confidence interval (CI), -10.1 to 10.7 ml). Semi-automated segmentation was significantly faster than manual segmentation, with a mean difference = 188 s (220 vs. 408 s); p < 0.05. Volumes did not differ significantly comparing the results of different readers. Calculation of TKV with a modified ellipsoid formula (ellipsoid volume × 0.85) did not differ significantly from the reference volume; however, the mean error was three times higher (difference of mean volumes -0.1 ml; CI -31.1 to 30.9 ml; p = 0.95). Applying the modified ellipsoid formula was the fastest way to get an estimation of the renal volume (41 s). Semi-automated segmentation and volumetric analysis of the kidney in native T2-weighted MR data delivers accurate and reproducible results and was significantly faster than manual segmentation. Applying a modified ellipsoid formula quickly provides an accurate kidney volume.


Asunto(s)
Enfermedades Renales/diagnóstico por imagen , Riñón/diagnóstico por imagen , Imagen por Resonancia Magnética , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados
2.
Diagnostics (Basel) ; 13(8)2023 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-37189538

RESUMEN

(1) Background: With the conventional contour surface method (KfM) for the evaluation of cardiac function parameters, the papillary muscle is considered to be part of the left ventricular volume. This systematic error can be avoided with a relatively easy-to-implement pixel-based evaluation method (PbM). The objective of this thesis is to compare the KfM and the PbM with regard to their difference due to papillary muscle volume exclusion. (2) Material and Methods: In the retrospective study, 191 cardiac-MR image data sets (126 male, 65 female; median age 51 years; age distribution 20-75 years) were analysed. The left ventricular function parameters: end-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined using classical KfW (syngo.via and cvi42 = gold standard) and PbM. Papillary muscle volume was calculated and segmented automatically via cvi42. The time required for evaluation with the PbM was collected. (3) Results: The size of EDV was 177 mL (69-444.5 mL) [average, [minimum-maximum]], ESV was 87 mL (20-361.4 mL), SV was 88 mL and EF was 50% (13-80%) in the pixel-based evaluation. The corresponding values with cvi42 were EDV 193 mL (89-476 mL), ESV 101 mL (34-411 mL), SV 90 mL and EF 45% (12-73%) and syngo.via: EDV 188 mL (74-447 mL), ESV 99 mL (29-358 mL), SV 89 mL (27-176 mL) and EF 47% (13-84%). The comparison between the PbM and KfM showed a negative difference for end-diastolic volume, a negative difference for end-systolic volume and a positive difference for ejection fraction. No difference was seen in stroke volume. The mean papillary muscle volume was calculated to be 14.2 mL. The evaluation with PbM took an average of 2:02 min. (4) Conclusion: PbM is easy and fast to perform for the determination of left ventricular cardiac function. It provides comparable results to the established disc/contour area method in terms of stroke volume and measures "true" left ventricular cardiac function while omitting the papillary muscles. This results in an average 6% higher ejection fraction, which can have a significant influence on therapy decisions.

3.
Front Oncol ; 9: 1324, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31828043

RESUMEN

Brain metastases are the most common intracranial tumor in adults and are associated with poor patient prognosis and median survival of only a few months. Treatment options for brain metastasis patients remain limited and largely depend on surgical resection, radio- and/or chemotherapy. The development and pre-clinical testing of novel therapeutic strategies require reliable experimental models and diagnostic tools that closely mimic technologies that are used in the clinic and reflect histopathological and biochemical changes that distinguish tumor progression from therapeutic response. In this study, we sought to test the applicability of magnetic resonance (MR) spectroscopy in combination with MR imaging to closely monitor therapeutic efficacy in a breast-to-brain metastasis model. Given the importance of radiotherapy as the standard of care for the majority of brain metastases patients, we chose to monitor the post-irradiation response by magnetic resonance spectroscopy (MRS) in combination with MR imaging (MRI) using a 7 Tesla small animal scanner. Radiation was applied as whole brain radiotherapy (WBRT) using the image-guided Small Animal Radiation Research Platform (SARRP). Here we describe alterations in different metabolites, including creatine and N-acetylaspartate, that are characteristic for brain metastases progression and lactate, which indicates hypoxia, while choline levels remained stable. Radiotherapy resulted in normalization of metabolite levels indicating tumor stasis or regression in response to treatment. Our data indicate that the use of MR spectroscopy in addition to MRI represents a valuable tool to closely monitor not only volumetrical but also metabolic changes during tumor progression and to evaluate therapeutic efficacy of intervention strategies. Adapting the analytical technology in brain metastasis models to those used in clinical settings will increase the translational significance of experimental evaluation and thus contribute to the advancement of pre-clinical assessment of novel therapeutic strategies to improve treatment options for brain metastases patients.

4.
Med Image Anal ; 11(1): 21-34, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17126064

RESUMEN

We present a new level-set based method to segment and quantify stenosed internal carotid arteries (ICAs) in 3D contrast-enhanced computed tomography angiography (CTA). Within these data sets it is a difficult task to evaluate the degree of stenoses deterministically even for the experienced physician because the actual vessel lumen is hardly distinguishable from calcified plaque and there is no sharp border between lumen and arterial wall. According to our knowledge no commercially available software package allows the detection of the boundary between lumen and plaque components. Therefore in the clinical environment physicians have to perform the evaluation manually. This approach suffers from both intra- and inter-observer variability. The limitation of the manual approach requires the development of a semi-automatic method that is able to achieve deterministic segmentation results of the internal carotid artery via level-set techniques. With the new method different kinds of plaques were almost completely excluded from the segmented regions. For an objective evaluation we also studied the method's performance with four different phantom data sets for which the ground truth of the degree of stenosis was known a priori. Finally, we applied the method to 10 ICAs and compared the obtained segmentations with manual measurements of three physicians.


Asunto(s)
Estenosis Carotídea/diagnóstico por imagen , Angiografía Cerebral/métodos , Imagenología Tridimensional/métodos , Almacenamiento y Recuperación de la Información/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Inteligencia Artificial , Angiografía Cerebral/instrumentación , Humanos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/instrumentación , Interfaz Usuario-Computador
5.
Artículo en Inglés | MEDLINE | ID: mdl-20425980

RESUMEN

Anatomical and functional information of cardiac vasculature is a key component of future developments in the field of interventional cardiology. With the technology of C-arm CT it is possible to reconstruct intraprocedural 3-D images from angiographic projection data. Current approaches attempt to add the temporal dimension (4-D) by ECG-gating in order to distinct physical states of the heart. This model assumes that the heart motion is periodic. However, frequently arrhytmic heart signals are observed in a clinical environment. In addition breathing motion can still occur. We present a reconstruction method based on a 4-D time-continuous motion field which is parameterized by the acquisition time and not the quasi-periodic heart phase. The output of our method is twofold. It provides a motion compensated 3-D reconstruction (anatomic information) and a motion field (functional information). In a physical phantom experiment a vessel of size 3.08 mm undergoing a non-periodic motion was reconstructed. The resulting diameters were 3.42 mm and 1.85 mm assuming non-periodic and periodic motion, respectively. Further, for two clinical cases (coronary arteries and coronary sinus) it is demonstrated that the presented algorithm outperforms periodic approaches and is able to handle realistic irregular heart motion.


Asunto(s)
Artefactos , Angiografía Coronaria/métodos , Imagenología Tridimensional/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Intervencional/métodos , Algoritmos , Inteligencia Artificial , Angiografía Coronaria/instrumentación , Humanos , Movimiento , Periodicidad , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción
6.
IEEE Trans Med Imaging ; 28(11): 1836-49, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19884068

RESUMEN

Generating 3-D images of the heart during interventional procedures is a significant challenge. In addition to real time fluoroscopy, angiographic C-arm systems can also now be used to generate 3-D/4-D CT images on the same system. One protocol for cardiac CT uses ECG triggered multisweep scans. A 3-D volume of the heart at a particular cardiac phase is then reconstructed by applying Feldkamp (FDK) reconstruction to the projection images with retrospective ECG gating. In this work we introduce a unified framework for heart motion estimation and dynamic cone-beam reconstruction using motion corrections. The benefits of motion correction are 1) increased temporal and spatial resolution by removing cardiac motion which may still exist in the ECG gated data sets and 2) increased signal-to-noise ratio (SNR) by using more projection data than is used in standard ECG gated methods. Three signal-enhanced reconstruction methods are introduced that make use of all of the acquired projection data to generate a 3-D reconstruction of the desired cardiac phase. The first averages all motion corrected back-projections; the second and third perform a weighted averaging according to 1) intensity variations and 2) temporal distance relative to a time resolved and motion corrected reference FDK reconstruction. In a comparison study seven methods are compared: nongated FDK, ECG-gated FDK, ECG-gated, and motion corrected FDK, the three signal-enhanced approaches, and temporally aligned and averaged ECG-gated FDK reconstructions. The quality measures used for comparison are spatial resolution and SNR. Evaluation is performed using phantom data and animal models. We show that data driven and subject-specific motion estimation combined with motion correction can decrease motion-related blurring substantially. Furthermore, SNR can be increased by up to 70% while maintaining spatial resolution at the same level as is provided by the ECG-gated FDK. The presented framework provides excellent image quality for cardiac C-arm CT.


Asunto(s)
Algoritmos , Tomografía Computarizada de Haz Cónico/métodos , Corazón , Procesamiento de Imagen Asistido por Computador/métodos , Procesamiento de Señales Asistido por Computador , Animales , Simulación por Computador , Electrocardiografía , Corazón/diagnóstico por imagen , Corazón/fisiología , Movimiento (Física) , Fantasmas de Imagen , Cirugía Asistida por Computador/métodos , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA