Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Molecules ; 28(3)2023 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-36770879

RESUMEN

The increasing number of contaminants in the environment has pushed water monitoring programs to find out the most hazardous known and unknown chemicals in the environment. Sample treatment-simplification methods and non-target screening approaches can help researchers to not overlook potential chemicals present in complex aqueous samples. In this work, an effect-directed analysis (EDA) protocol using the sea urchin embryo test (SET) as a toxicological in vivo bioassay was used as simplified strategy to identify potential unknown chemicals present in a very complex aqueous matrix such as hospital effluent. The SET bioassay was used for the first time here to evaluate potential toxic fractions in hospital effluent, which were obtained after a two-step fractionation using C18 and aminopropyl chromatographic semi-preparative columns. The unknown compounds present in the toxic fractions were identified by means of liquid chromatography coupled to a Q Exactive Orbitrap high-resolution mass spectrometer (LC-HRMS) and using a suspect analysis approach. The results were complemented by gas chromatography-mass spectrometry analysis (GC-MS) in order to identify the widest range of chemical compounds present in the sample and the toxic fractions. Using EDA as sample treatment simplification method, the number of unknown chemicals (>446 features) detected in the raw sample was narrowed down to 94 potential toxic candidates identified in the significantly toxic fractions. Among them, the presence of 25 compounds was confirmed with available chemical standards including 14 pharmaceuticals, a personal care product, six pesticides and four industrial products. The observations found in this work emphasize the difficulties in identifying potential toxicity drivers in complex water samples, as in the case of hospital wastewater.


Asunto(s)
Aguas Residuales , Contaminantes Químicos del Agua , Contaminantes Químicos del Agua/toxicidad , Contaminantes Químicos del Agua/análisis , Espectrometría de Masas/métodos , Agua/análisis , Hospitales , Monitoreo del Ambiente/métodos
2.
Anal Bioanal Chem ; 414(23): 6855-6869, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35904524

RESUMEN

In the present work, a target analysis method for simultaneously determining 24 diverse endocrine-disrupting compounds (EDCs) in urine (benzophenones, bisphenols, parabens, phthalates and antibacterials) was developed. The target analysis approach (including enzymatic hydrolysis, clean-up by solid-phase extraction and analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)) was optimized, validated and applied to volunteers' samples, in which 67% of the target EDCs were quantified. For instance, benzophenone-3 (0.2-13 ng g-1), bisphenol A (7.7-13.7 ng g-1), methyl 3,5-dihydroxybenzoate (8-254 ng g-1), mono butyl phthalate (2-17 ng g-1) and triclosan (0.3-9 ng g-1) were found at the highest concentrations, but the presence of other analogues was detected as well. The developed target method was further extended to suspect and non-target screening (SNTS) by means of LC coupled to high-resolution MS/MS. First, well-defined workflows for SNTS were validated by applying the previously developed method to an extended list of compounds (83), and then, to the same real urine samples. From a list of approximately 4000 suspects, 33 were annotated at levels from 1 to 3, with food additives/ingredients and personal care products being the most abundant ones. In the non-target approach, the search was limited to molecules containing S, Cl and/or Br atoms, annotating 4 pharmaceuticals. The results from this study showed that the combination of the lower limits of detection of MS/MS and the identification power of high-resolution MS/MS is still compulsory for a more accurate definition of human exposome in urine samples.


Asunto(s)
Disruptores Endocrinos , Espectrometría de Masas en Tándem , Compuestos de Bencidrilo/análisis , Cromatografía Liquida/métodos , Disruptores Endocrinos/análisis , Humanos , Parabenos/análisis , Extracción en Fase Sólida , Espectrometría de Masas en Tándem/métodos
3.
Environ Sci Technol ; 54(14): 8890-8899, 2020 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-32525664

RESUMEN

Sea urchin embryo assay was used to assess general toxicity at four wastewater treatment plant effluents of Biscay (Gorliz, Mungia, Gernika, and Galindo), and within the tested range, all the extracts showed embryo growth inhibition and skeleton malformation activities with EC50 values, in relative enrichment factor units, between 1.1-16.8 and 1.1-8.8, respectively. To identify the causative compounds, effect-directed analysis was successfully applied for the first time using a sea urchin embryo test to the secondary treatment of the Galindo effluent. To this end, two subsequent fractionation steps were performed using C18 (21 fractions) and aminopropyl columns (15 fractions). By this fractionation, the number of features detected by LC-HRMS in the raw sample was drastically reduced from 1500 to 9, and among them, two pesticides (mexacarbate, 17 ng/L, and fenpropidin, 23 ng/L), two antidepressants (amitriptyline, 304 ng/L, and paroxetine, 26 ng/L), and two anthelmintic agents (mebendazole, 65 ng/L, and albendazole, 48 ng/L) could be identified in the two toxic fractions. The artificial mixture of the identified six compounds could explain 79% of the observed effect, with albendazole and paroxetine as the predominant contributors (49% and 49%, respectively) affecting the sea urchin embryogenesis activity.


Asunto(s)
Aguas Residuales , Contaminantes Químicos del Agua , Animales , Bioensayo , Embrión no Mamífero , Desarrollo Embrionario , Erizos de Mar , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/toxicidad
4.
Anal Chem ; 91(9): 5739-5746, 2019 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-30915838

RESUMEN

An automatic mesofluidic system combining dynamic oral bioaccessibility with lab-on-valve (LOV)-based sorptive microextraction is herein proposed for the first time for exploring the kinetics of leaching of incurred rather than spiked organic emerging contaminants (viz., methyl paraben, butyl paraben, diclofenac, and triclosan) from exposed mussels on the basis of the Versantvoort's fed-state physiological extraction test. Our method capitalizes on programmable flow analysis, in which gastrointestinal extracts are obtained online by pumping a simulated biorelevant gastrointestinal fluid across a large-bore column (maintained at 37.0 ± 2.0 °C) loaded with 250 mg of freeze-dried and powdered mussel onto a polyvinyldiene difluoride filter membrane. The physiologically relevant extracts are then cleaned up, and the analytes are preconcentrated onto a dedicated reversed-phase solid-phase extraction (Oasis PRIME-HLB) microcolumn that is captured into the channels of an LOV mesofluidic platform. The aim behind this is to obtain analyte-laden eluates with ACN/MeOH (90:10, v/v) in unsupervised mode for direct injection into LC-MS. The LOV minicolumn (≤25 mg) is automatically disposed of and renewed for every individual fraction on account of the strong retention of (phospho)lipids by the copolymeric sorbent. The proposed dynamic bioaccessibility test features a significant shortening of the extraction time against the batch method (28 vs 240 min) while avoiding overestimation of potentially bioavailable fractions. The trueness of the online gastrointestinal extraction method was confirmed using mass-balance validation following ultrasonic-assisted solid-liquid extraction of the original mussel sample and the residual (nonbioaccessible) fraction of emerging contaminants.


Asunto(s)
Líquidos Corporales/metabolismo , Análisis de Inyección de Flujo/instrumentación , Tracto Gastrointestinal/metabolismo , Compuestos Orgánicos/análisis , Extracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/análisis , Animales , Automatización , Bivalvos , Cromatografía Líquida de Alta Presión , Análisis de Inyección de Flujo/métodos , Compuestos Orgánicos/aislamiento & purificación , Polímeros/química , Contaminantes Químicos del Agua/aislamiento & purificación
5.
Anal Bioanal Chem ; 411(2): 493-506, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30478518

RESUMEN

In this work, the full optimisation and validation procedure to analyse a wide set of emerging organic contaminants in biotissues (mussel and fish muscle, liver, gills and brain) and biofluids (fish plasma and bile) is described. The target families include artificial sweeteners, industrial products, hormones, pharmaceutical and personal care products, pesticides and phytoestrogens. Different clean-up strategies (hydrophilic-lipophilic-balanced (HLB) solid-phase extraction, Florisil solid-phase extraction and liquid-liquid extraction followed by HLB solid-phase extraction and microextraction based on polyethersulfone polymer) were evaluated for the clean-up of focused ultrasonic solid-liquid extraction (FUSLE) extracts before the analysis by liquid chromatography-triple quadrupole tandem mass spectrometry (LC-QqQ-MS/MS). The methods afforded satisfactory apparent recovery values (71-126%) using isotopically labelled analytes and matrix-matched calibration approach, regardless of the matrix. Method detection limits in the range of 4-48 ng/g and 0.3-111 ng/L were obtained for biotissues and biofluids, respectively. The developed method was applied to determine the uptake and tissue distribution in juvenile gilt-head bream (Sparus aurata) during 7 days in seawater, and unexpectedly, perfluoro-1-butanesulfonate tended to accumulate in liver and, to a lesser extent, in muscle and gills. Furthermore, real mussel samples collected in the Basque coast were also analysed and the presence of the highly consumed valsartan (7 ng/g) and telmisartan (6.8 ng/g) compounds in bivalves is reported for the first time here. Graphical abstract ᅟ.


Asunto(s)
Bivalvos , Líquidos Corporales/química , Cromatografía Liquida , Peces , Espectrometría de Masas en Tándem , Contaminantes Químicos del Agua/química , Animales , Compuestos Orgánicos/química , Dorada , Agua de Mar , Contaminantes Químicos del Agua/farmacocinética
6.
Environ Sci Technol ; 52(5): 2603-2611, 2018 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-29415544

RESUMEN

N-ethyl perfluorooctane sulfonamide (EtFOSA) is the active ingredient of Sulfluramid, a pesticide which is used extensively in South America for control of leaf-cutting ants. Despite being a known precursor to perfluorooctanesulfonate (PFOS), the importance of EtFOSA as a source of environmental PFOS remains unclear. In the present work, uptake, leaching, and biodegradation of EtFOSA and its transformation products were assessed over 81 days in soil-carrot ( Daucus carota ssp sativus) mesocosms for the first time. Experiments performed in the presence of carrot produced PFOS yields of up to 34% using a technical EtFOSA standard and up to 277% using Grão Forte, a commercial Sulfluramid bait formulation containing 0.0024% EtFOSA. Perfluorooctane sulfonamido acetate (FOSAA), perfluorooctane sulfonamide (FOSA), and perfluorooctanoic acid (PFOA) also formed over the course of the experiments, with the latter substance attributed to the presence of perfluorooctanamide impurities. The leachate contained low levels of transformation products and a high FOSA:PFOS ratio, consistent with recent observations in Brazilian surface water. In carrots, the more hydrophilic transformation products (e.g., PFOS) occurred primarily in the leaves, while the more hydrophobic products (e.g., FOSA, FOSAA, and EtFOSA) occurred in the peel and core. Remarkably, isomer-specific analysis revealed that the linear EtFOSA isomer biodegraded significantly faster than branched isomers. These data collectively show that the application of Sulfluramid baits can lead to the occurrence of PFOS in crops and in the surrounding environment, in considerably higher yields than previously thought.


Asunto(s)
Ácidos Alcanesulfónicos , Daucus carota , Fluorocarburos , Plaguicidas , Contaminantes del Suelo , Brasil , Suelo , Sulfonamidas
7.
Anal Bioanal Chem ; 410(2): 615-632, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29214535

RESUMEN

A new procedure using polyethersulfone (PES) microextraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis was developed in this work for the simultaneous determination of 41 multiclass priority and emerging organic pollutants including herbicides, hormones, personal care products, and pharmaceuticals, among others, in seawater, wastewater treatment plant (WWTP) effluents, and estuary samples. The optimization of the analysis included two different chromatographic columns and different variables (polarity, fragmentor voltage, collision energy, and collision cell accelerator) of the mass spectrometer. In the case of PES extraction, ion strength of the water, pH, addition of EDTA, and the amount of the polymeric material were thoroughly investigated. The developed procedure was compared with a previously validated one based on a standard solid-phase extraction (SPE). In contrast to the SPE protocol, the PES method allowed a cost-efficient extraction of complex aqueous samples with lower matrix effect from 120 mL of water sample. Satisfactory and comparable apparent recovery values (80-119 and 70-131%) and method quantification limits (MQLs, 0.4-26 and 0.2-23 ng/L) were obtained for PES and SPE procedures, respectively, regardless of the matrix. Repeatability values lower than 27% were obtained. Finally, the developed methods were applied to the analysis of real samples from the Basque Country and irbesartan, valsartan, acesulfame, and sucralose were the analytes most often detected at the highest concentrations (51-1096 ng/L). Graphical abstract Forty-one multiclass pollutant determination in environmental waters by means of PES/SPE-LC-MS/MS.


Asunto(s)
Herbicidas/análisis , Hormonas/análisis , Preparaciones Farmacéuticas/análisis , Polímeros/química , Extracción en Fase Sólida/métodos , Sulfonas/química , Espectrometría de Masas en Tándem/métodos , Contaminantes Químicos del Agua/análisis , Cromatografía Liquida/métodos , Estuarios , Límite de Detección , Agua de Mar/análisis , Aguas Residuales/análisis
8.
Anal Bioanal Chem ; 409(27): 6359-6370, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28852783

RESUMEN

This work describes the optimization, validation, and application in real samples of accurate and precise analytical methods to determine ten fluoroquinolones (FQs) (norfloxacin, enoxacin, pefloxacin, ofloxacin, levofloxacin, ciprofloxacin, danofloxacin, lomefloxacin, enrofloxacin, and sparfloxacin) in different environmental matrices, such as water (estuarine, seawater, and wastewater treatment plant effluent), fish tissues (muscle and liver), and fish biofluids (plasma and bile). The analysis step performed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was fully optimized to improve the separation and detection steps. The extraction of analytes from fish tissues was accomplished using focused ultrasound solid-liquid extraction using methanol/acetic acid (95:5 v/v) as extractant. The preconcentration and clean-up steps were optimized in terms of extraction efficiency and cleanliness and the best strategy for each matrix was selected: (i) Oasis HLB for seawater and muscle, (ii) liquid-liquid extraction combined with Oasis HLB for the lipid-rich liver, (iii) the combination of Evolute-WAX and Oasis HLB for estuarine water and wastewater treatment plant effluent, and (iv) molecular imprinted polymers for biofluids. The methods afforded satisfactory apparent recoveries (80-126%) and repeatability (RSD < 15%), except for sparfloxacin, which showed a lack of correction with the available isotopically labeled surrogates ([2H8]-ciprofloxacin and [2H5]-enrofloxacin). Ciprofloxacin, norfloxacin, and ofloxacin were detected in both water and fish liver samples from the Biscay Coast at concentrations up to 278 ng/L and 4 ng/g, respectively. To the best of our knowledge, this work is one of the few analyzing up to ten FQs and in so many fish tissues and biofluids. Graphical abstract Determination of fluoroquinolones in different environmental matrices, such as water (estuarine, seawater, and wastewater treatment plant effluent), fish tissues (muscle and liver), and fish biofluids (plasma and bile).


Asunto(s)
Cromatografía Liquida/métodos , Monitoreo del Ambiente/métodos , Peces , Fluoroquinolonas/análisis , Espectrometría de Masas en Tándem/métodos , Contaminantes Químicos del Agua/análisis , Animales , Bilis/química , Estuarios , Peces/sangre , Peces/metabolismo , Límite de Detección , Agua de Mar/análisis , Extracción en Fase Sólida/métodos , Sonicación/métodos , Aguas Residuales/análisis
9.
Anal Bioanal Chem ; 408(21): 5689-5700, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27342793

RESUMEN

This study describes a new method for the simultaneous extraction of several endocrine disrupting compounds, including alkylphenols (APs), estrogen, bisphenol-A (BPA) and one phthalate metabolite (mono-2-ethylhexyl ester, MEHP) in fish liver, brain, and muscle. Parameters affecting the extraction (extraction solvent and temperature) and the clean-up (dispersive phase nature and amount) steps were evaluated. The extraction was performed by means of focused ultrasound solid-liquid extraction (FUSLE) using 10 mL of n-hexane:acetone (50:50, v/v) for 5 min at ~0 °C, and the clean-up was done by means of dispersive solid phase extraction (dSPE) using 100 mg of ENVI-CARB and 100 mg of MgSO4 for the cleaning of brain and muscle extracts together with 100 mg of PSA in the case of liver extracts. Good apparent recoveries were obtained in the case of liver (62-132 %), brain (66-120 %), and muscle (74-129 %), relative standard deviation (RSD%) was always below 26 %, and the method detection limits (MDLs) were at low ng/g level. The developed method was applied to fish captured in Urdaibai estuary (Bay of Biscay) in December 2015, and the concentrations obtained were in the range MDL-1115 ng/g in brain, MDL-962 ng/g in muscle, and MDL-672 ng/g in liver. In general, the highest concentrations were measured in liver, followed by brain and muscle. In addition, diethylstilbestrol was only detected in fish brain. Graphical Abstract MS method scheme for the/MS method scheme for the determination of EDCs in fish liver, brain and muscle.


Asunto(s)
Disruptores Endocrinos/análisis , Peces/metabolismo , Extracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/análisis , Animales , Compuestos de Bencidrilo/análisis , Encéfalo/metabolismo , Estrógenos/análisis , Límite de Detección , Hígado/metabolismo , Músculos/metabolismo , Fenoles/análisis , Ácidos Ftálicos/análisis , Sonicación/métodos , Espectrometría de Masas en Tándem/métodos
10.
Anal Bioanal Chem ; 408(4): 1205-16, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26677016

RESUMEN

This work describes the optimization, validation, and application in real samples of accurate and precise analytical methods to determine tricyclic antidepressants (TCAs), including amitriptyline, nortriptyline, imipramine, and clomipramine in different environmental matrices, such as water (estuary, seawater, and wastewater treatment plant effluent) and biota (fish muscle, fish liver, and mussels), which would lead to supplement the scarce information on the presence of TCAs in aquatic organisms. The analysis step performed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was fully optimized to improve the sensitivity of the separation and detection steps. The extraction of solid samples was accomplished using focused ultrasonic solid-liquid extraction (FUSLE), which required a low amount of sample (0.5 g), solvent (7 mL acetonitrile/H2O, 95:5 v/v) and short extraction time (30 s). In the optimisation of the clean-up step, mixed mode solid-phase extraction (SPE) using a strong cation exchanger rendered clean extracts and the best results in terms of extraction efficiency and matrix effect. The same SPE mode was also used for the extraction and pre-concentration of TCAs from environmental water matrices. The methods afforded satisfactory apparent recovery values (86-122%) and repeatability (RSD < 5%), regardless of the matrix. Finally, the developed methods were applied to the analysis of real samples from the Biscay Coast, where TCAs were detected in both water and biota samples up to 25.9 ng/L and 1.8 ng/g, respectively. Up to our knowledge, this is the first work using FUSLE for the determination of TCAs and one of the few analyzing TCAs in biota samples.


Asunto(s)
Antidepresivos Tricíclicos/análisis , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Contaminantes Químicos del Agua/análisis , Animales , Estuarios , Peces , Contaminación de Alimentos/análisis , Límite de Detección , Hígado/química , Músculo Esquelético/química , Mytilus/química , Agua de Mar/análisis , Extracción en Fase Sólida/métodos , España , Espectrometría de Masa por Ionización de Electrospray/métodos , Aguas Residuales/análisis
11.
Anal Bioanal Chem ; 408(12): 3165-75, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26892638

RESUMEN

The uptake calibration of more than 12 non-polar organic contaminants by 3 polymeric materials is shown: bare polydimetilsiloxane (PDMS, stir-bars), polyethersulfone tubes and membranes (PES) and polyoxymethylene membranes (POM), both in their free form and membrane-enclosed sorptive coating (MESCO). The calibration process was carried out exposing the samplers to a continuous flow of contaminated water at 100 ng mL(-1) for up to 28 days, and, consequently, the sampling rates (Rs, mL day(-1)) of several organic microcontaminants were provided for the first time. In situ Rs values were also determined disposing the samplers in the effluent of a wastewater treatment plant. Finally, these passive samplers were applied to monitor the effluents of two wastewater treatment plants. This application lead to the confirmation of the presence of galaxolide, tonalide and 4-tert-octylphenol at high ng mL(-1) levels, as well as the identification of compounds like some phthalates and alkylphenols at levels below the detection limits for active sampling methods.

12.
Anal Bioanal Chem ; 407(24): 7413-23, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26229028

RESUMEN

This study describes a new method for the simultaneous extraction and enzymatic hydrolysis of alkylphenols, estrogens, bisphenol-A and phthalate metabolite (mono-2-ethylhexyl ester, MEHP) in fish bile using polyethersulfone (PES) polymer as sorptive material. Parameters affecting the hydrolysis (enzyme amount) and extraction (nature of polymeric material, PES desorption solvent nature and time, PES amount and time profile) were optimised. The optimum conditions were fixed as: 5 PES tubes (1.5 cm length × 0.7 mm o.d.) were added to a vessel with 100 µL of sample, 800 µL of ultrapure water, 1.5 mL phosphate buffer (0.1 mol L(-1), pH 6) and 200 µL of ß-glucuronidase (1000 U mL(-1)) enzyme and the mixture was stirred at 37 °C and 550 rpm for 3 h. Quantitative results were obtained after desorption of PES material using 500 µL of ethyl acetate. The extracts were reconstituted in 250 µL of methanol and analysed by liquid chromatography-tandem mass spectrometry, obtaining apparent recoveries in the range of 73-134 % using deuterated compounds surrogates corrections. Relative standard deviations below 27 % were obtained for all target analytes and the method detection limits (MDLs) were in low nanograms per mililliter level for all the studied compounds, except in the case of MEHP which was detected at higher concentration levels (ng µL(-1)) in bile samples that do not allow its MDL determination. Bisphenol A (MDL-10.8 ng mL(-1)), diethylstilbestrol (MDL-1.4 ng mL(-1)) and MEHP (975-2604 ng mL(-1)) were detected in grey mullets captured nearby the wastewater treatment plant of Gernika (Biosphere Reserve of Urdaibai).


Asunto(s)
Bilis/metabolismo , Disruptores Endocrinos/metabolismo , Glucuronidasa/metabolismo , Polímeros/química , Smegmamorpha/metabolismo , Sulfonas/química , Animales , Cromatografía Liquida , Disruptores Endocrinos/aislamiento & purificación , Espectrometría de Masas en Tándem
13.
J Sep Sci ; 38(13): 2298-304, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25885885

RESUMEN

According to the European Water Framework Directive, environmental assessment of organic compounds should be made in whole-water samples, but due to their hydrophobicity and strong attraction to organic content these compounds can be found bound to suspended particle matter or in the dissolved fraction. In this work, the extraction of musk compounds was studied in whole-water samples exhibiting different amounts of dissolved organic carbon and suspended particulate matter using polyethersulfone preconcentration technique. Matrix effects in estuarine and wastewater (both influent and effluent) were evaluated for filtered and unfiltered samples. For unfiltered samples, estuarine water exhibited matrix effects <20%, while for effluent it was up to 48% and for influent ranged from 85 to 99%. To compensate matrix effects and determine total concentrations in unfiltered samples, different quantification approaches were tested: the use of deuterated analogues and standard additions. Standard additions provided the best results for unfiltered samples. Finally, filtered and unfiltered samples were analyzed using both polyethersulfone preconcentration and membrane-assisted solvent extraction and results showed a good agreement between the two methods. In both cases unfiltered samples provided concentrations 1.5-2.6 times higher than filtered samples.

14.
Chemosphere ; 351: 141221, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38224745

RESUMEN

Suspect and non-target screening (SNTS) methods are being promoted in order to decode the human exposome since a wide chemical space can be analysed in a diversity of human biofluids. However, SNTS approaches in the exposomics field are infra-studied in comparison to environmental or food monitoring studies. In this work, a comprehensive suspect screening workflow was developed to annotate exposome-related xenobiotics and phase II metabolites in diverse human biofluids. Precisely, human urine, breast milk, saliva and ovarian follicular fluid were employed as samples and analysed by means of ultra-high performance liquid chromatography coupled with high resolution tandem mass spectrometry (UHPLC-HRMS/MS). To automate the workflow, the "peak rating" parameter implemented in Compound Discoverer 3.3.2 was optimized to avoid time-consuming manual revision of chromatographic peaks. In addition, the presence of endogenous molecules that might interfere with the annotation of xenobiotics was carefully studied as the employment of inclusion and exclusion suspect lists. To evaluate the workflow, limits of identification (LOIs) and type I and II errors (i.e., false positives and negatives, respectively) were calculated in both standard solutions and spiked biofluids using 161 xenobiotics and 22 metabolites. For 80.3 % of the suspects, LOIs below 15 ng/mL were achieved. In terms of type I errors, only two cases were identified in standards and spiked samples. Regarding type II errors, the 7.7 % errors accounted in standards increased to 17.4 % in real samples. Lastly, the use of an inclusion list for endogens was favoured since it avoided 18.7 % of potential type I errors, while the exclusion list caused 7.2 % of type II errors despite making the annotation workflow less time-consuming.


Asunto(s)
Exposoma , Femenino , Humanos , Xenobióticos/metabolismo , Flujo de Trabajo , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem
15.
Talanta ; 271: 125698, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38262128

RESUMEN

Persistent, mobile and toxic substances have drawn attention nowadays due to their particular properties, but they are overlooked in human monitorization works, limiting the knowledge of the human exposome. In that sense, human urine is an interesting matrix since not only parent compounds are eliminated, but also their phase II metabolites that could act as biomarkers. In this work, 11 sample preparation procedures involving preconcentration were tested to ensure maximum analytical coverage in human urine using mixed-mode liquid chromatography coupled with high-resolution tandem mass spectrometry. The optimized procedure consisted of a combination of solid-phase extraction and salt-assisted liquid-liquid extraction and it was employed for suspect screening. Additionally, a non-discriminatory dilute-and-shoot approach was also evaluated. After evaluating the workflow in terms of limits of identification and type II errors (i.e., false negatives), a pooled urine sample was analysed. From a list of 1450 suspects and in-silico simulated 1568 phase II metabolites (i.e. sulphates, glucuronides, and glycines), 44 and 14 substances were annotated, respectively. Most of the screened suspects were diverse industrial chemicals, but biocides, natural products and pharmaceuticals were also detected. Lastly, the complementarity of the sample preparation procedures, columns, and analysis conditions was assessed. As a result, dilute-and-shoot and the Acclaim Trinity P1 column at pH = 3 (positive ionization) and pH = 7 (negative ionization) allowed the maximum coverage since almost 70 % of the total suspects could be screened using those conditions.


Asunto(s)
Líquidos Corporales , Espectrometría de Masas en Tándem , Humanos , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida , Espectrometría de Masas en Tándem/métodos , Manejo de Especímenes , Extracción en Fase Sólida/métodos
16.
J Chromatogr A ; 1705: 464141, 2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37364523

RESUMEN

In this work, a comprehensive method for the simultaneous determination of 33 diverse persistent and mobile organic compounds (PMOCs) in human urine was developed by dilute-and-shoot (DS) followed by mixed-mode liquid chromatography coupled with tandem mass spectrometry (MMLC-MS/MS). In the sample preparation step, DS was chosen since it allowed the quantification of all targets in comparison to lyophilization. For the chromatographic separation, Acclaim Trinity P1 and P2 trimodal columns provided greater capacity for retaining PMOCs than reverse phase and hydrophilic interaction liquid chromatography. Therefore, DS was validated at 5 and 50 ng/mL in urine with both mixed mode columns at pH = 3 and 7. Regarding figures of merit, linear calibration curves (r2 > 0.999) built between instrumental quantification limits (mostly below 5 ng/mL) and 500 ng/mL were achieved. Despite only 60% of the targets were recovered at 5 ng/mL because of the dilution, all PMOCs were quantified at 50 ng/mL. Using surrogate correction, apparent recoveries in the 70-130% range were obtained for 91% of the targets. To analyse human urine samples, the Acclaim Trinity P1 column at pH = 3 and 7 was selected as a consensus between analytical coverage (i.e. 94% of the targets) and chromatographic runs. In a pooled urine sample, industrial chemicals (acrylamide and bisphenol S), biocides and their metabolites (2-methyl-4-isothiazolin-3-one, dimethyl phosphate, 6-chloropyridine-3-carboxylic acid, and ammonium glufosinate) and an artificial sweetener (aspartame) were determined at ng/mL levels. The outcomes of this work showed that humans are also exposed to PMOCs due to their persistence and mobility, and therefore, further human risk assessment is needed.


Asunto(s)
Urinálisis , Límite de Detección , Urinálisis/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Cromatografía Líquida de Alta Presión/métodos
17.
Mar Pollut Bull ; 189: 114786, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36893648

RESUMEN

This investigation deals with how temperature influences oil toxicity, alone or combined with dispersant (D). Larval lengthening, abnormalities, developmental disruption, and genotoxicity were determined in sea urchin embryos for assessing toxicity of low-energy water accommodated fractions (LEWAF) of three oils (NNA crude oil, marine gas oil -MGO-, and IFO 180 fuel oil) produced at 5-25 °C. PAH levels were similar amongst LEWAFs but PAH profiles varied with oil and production temperature. The sum of PAHs was higher in oil-dispersant LEWAFs than in oil LEWAFs, most remarkably at low production temperatures in the cases of NNA and MGO. Genotoxicity, enhanced after dispersant application, varied depending on the LEWAF production temperature in a different way for each oil. Impaired lengthening, abnormalities and developmental disruption were recorded, the severity of the effects varying with oil, dispersant application and LEWAF production temperature. Toxicity, only partially attributed to individual PAHs, was higher at lower LEWAF production temperatures.


Asunto(s)
Contaminación por Petróleo , Petróleo , Hidrocarburos Policíclicos Aromáticos , Contaminantes Químicos del Agua , Animales , Temperatura , Óxido de Magnesio , Contaminantes Químicos del Agua/toxicidad , Contaminantes Químicos del Agua/análisis , Aceites , Petróleo/toxicidad , Alimentos Marinos , Erizos de Mar , Hidrocarburos Policíclicos Aromáticos/toxicidad , Agua
18.
Chemosphere ; 339: 139690, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37541438

RESUMEN

The use of suspect and non-target screening (SNTS) for the characterization of the chemical exposome employing human biofluids is gaining attention. Among the biofluids, urine is one of the preferred matrices since organic xenobiotics are excreted through it after metabolization. However, achieving a consensus between selectivity (i.e. preserving as many compounds as possible) and sensitivity (i.e. minimizing matrix effects by removing interferences) at the sample preparation step is challenging. Within this context, several sample preparation approaches, including solid-phase extraction (SPE), liquid-liquid extraction (LLE), salt-assisted LLE (SALLE) and dilute-and-shoot (DS) were tested to screen not only exogenous compounds in human urine but also their phase II metabolites using liquid-chromatography coupled to high-resolution tandem mass spectrometry (LC-HRMS/MS). Additionally, enzymatic hydrolysis of phase II metabolites was evaluated. Under optimal conditions, SPE resulted in the best sample preparation approach in terms of the number of detected xenobiotics and metabolites since 97.1% of the total annotated suspects were present in samples extracted by SPE. In LLE and SALLE, pure ethyl acetate turned out to be the best extractant but fewer suspects than with SPE (80.7%) were screened. Lastly, only 52.5% of the suspects were annotated in the DS approach, showing that it could only be used to detect compounds at high concentration levels. Using pure standards, the presence of diverse xenobiotics such as parabens, industrial chemicals (benzophenone-3, caprolactam and mono-2-ethyl-5-hydroxyhexyl phthalate) and chemicals related to daily habits (caffeine, cotinine or triclosan) was confirmed. Regarding enzymatic hydrolysis, only 10 parent compounds of the 44 glucuronides were successfully annotated in the hydrolysed samples. Therefore, the screening of metabolites in non-hydrolysed samples through SNTS is the most suitable approach for exposome characterization.


Asunto(s)
Exposoma , Xenobióticos , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Extracción en Fase Sólida/métodos
19.
MethodsX ; 11: 102252, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37342804

RESUMEN

This work describes the development of a robust analytical methodology for the simultaneous determination of 50 semi-volatile organic compounds (SVOCs) in wastewater effluent samples by solid-phase extraction (SPE) followed by gas chromatography coupled to mass spectrometry (GC-MS) analysis. In this work, we studied extensively whether the validated SPE method used for the analysis of polar compounds in wastewaters could be extended to the analysis of non-polar compounds in the same analytical run. To that aim, the effect of different organic solvents in the SPE process (i.e., sample conditioning prior to SPE, elution solvent and evaporation steps) was evaluated. In this sense, the addition of methanol to wastewater samples before the extraction, the use of hexane:toluene (4:1, v/v) mixture for the quantitative elution of target compounds, and the addition of isooctane during the evaporation were required to minimize analyte losses during SPE and enhance extraction yields. Overall, the developed methodology showed a good performance for the determination of 50 SVOCs, and was further applied to the analysis of real wastewater effluent samples.•A validated SPE method for polar compounds was extended to the analysis of non-polar compounds.•Elution with hex:tol (4:1, v/v) and the addition of isooctane during the evaporation yield good recoveries.•The developed methodology was suitable for the determination of 50 SVOCs in aqueous samples.

20.
Environ Int ; 181: 108288, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37918065

RESUMEN

A collaborative trial involving 16 participants from nine European countries was conducted within the NORMAN network in efforts to harmonise suspect and non-target screening of environmental contaminants in whole fish samples of bream (Abramis brama). Participants were provided with freeze-dried, homogenised fish samples from a contaminated and a reference site, extracts (spiked and non-spiked) and reference sample preparation protocols for liquid chromatography (LC) and gas chromatography (GC) coupled to high resolution mass spectrometry (HRMS). Participants extracted fish samples using their in-house sample preparation method and/or the protocol provided. Participants correctly identified 9-69 % of spiked compounds using LC-HRMS and 20-60 % of spiked compounds using GC-HRMS. From the contaminated site, suspect screening with participants' own suspect lists led to putative identification of on average ∼145 and ∼20 unique features per participant using LC-HRMS and GC-HRMS, respectively, while non-target screening identified on average ∼42 and ∼56 unique features per participant using LC-HRMS and GC-HRMS, respectively. Within the same sub-group of sample preparation method, only a few features were identified by at least two participants in suspect screening (16 features using LC-HRMS, 0 features using GC-HRMS) and non-target screening (0 features using LC-HRMS, 2 features using GC-HRMS). The compounds identified had log octanol/water partition coefficient (KOW) values from -9.9 to 16 and mass-to-charge ratios (m/z) of 68 to 761 (LC-HRMS and GC-HRMS). A significant linear trend was found between log KOW and m/z for the GC-HRMS data. Overall, these findings indicate that differences in screening results are mainly due to the data analysis workflows used by different participants. Further work is needed to harmonise the results obtained when applying suspect and non-target screening approaches to environmental biota samples.


Asunto(s)
Monitoreo del Ambiente , Peces , Animales , Humanos , Monitoreo del Ambiente/métodos , Cromatografía de Gases y Espectrometría de Masas , Cromatografía Liquida/métodos , Espectrometría de Masas/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA