Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Ultrasound Med ; 38(3): 597-604, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30378156

RESUMEN

OBJECTIVES: To investigate hemodynamic changes in the hepatic artery after hepatic ischemia-reperfusion injury (IRI) in rats via ultrasound (US) imaging and to discuss the protective effect of phentolamine (PHT) pretreatment on hepatic IRI. METHODS: Fifty rats were randomly divided into 3 groups: a sham operation group (n = 10), a control ischemia-reperfusion group (n = 20), and a PHT pretreatment group (n = 20). Color Doppler flow imaging and contrast-enhanced US examinations were performed in each group at 30 minutes (n = 10) and 90 minutes (n = 10) after reperfusion. Blood samples were obtained to analyze serum alanine aminotransferase and aspartate aminotransferase levels, and liver tissue specimens were collected for pathologic analysis. RESULTS: Using US, we found that hepatic artery resistance at 30 minutes after reperfusion in the control group was higher than that in the sham group (mean resistive index [RI] ± SD, 0.65 ± 0.09 versus 0.50 ± 0.09; P < .01), which was higher at 30 than 90 minutes (RI, 0.65 ± 0.09 versus 0.50 ± 0.08; P < .01) after reperfusion in the control group. However, the hepatic artery resistance and liver microcirculation in the PHT group were better than those in the control group at 30 minutes after reperfusion (RI, 0.54 ± 0.09 versus 0.65 ± 0.09; P < .05; time to peak, 31.94 ± 2.02 versus 48.34 ± 4.74 seconds; P < .01). Compared to the control group, the aspartate aminotransferase and alanine aminotransferase levels were significantly lower at 30 minutes after reperfusion in the PHT group (P < .05). A pathologic examination revealed a smaller hepatic artery diameter and a depressed vessel wall in the control group. CONCLUSIONS: The hepatic artery can undergo a transient spasm during the hepatic IRI process, which can exacerbate liver damage. Phentolamine treatment can alleviate hepatic artery spasms, improve liver perfusion, and reduce liver injury by ameliorating the hepatic microcirculation.


Asunto(s)
Arteria Hepática/diagnóstico por imagen , Arteria Hepática/fisiopatología , Daño por Reperfusión/diagnóstico , Daño por Reperfusión/patología , Animales , Modelos Animales de Enfermedad , Hígado/diagnóstico por imagen , Hígado/fisiopatología , Masculino , Ratas , Ratas Sprague-Dawley , Ultrasonografía/métodos
2.
J Ultrasound Med ; 33(11): 1971-7, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25336484

RESUMEN

OBJECTIVES: The clinical utility of contrast-enhanced sonography in portal hypertension remains unclear. We explored the feasibility of using contrast-enhanced sonography for noninvasive assessment of portal venous pressure. METHODS: Twenty healthy individuals (control group; 9 men; mean age, 46.4 years) and 18 patients with portal hypertension (15 men; mean age, 46.2 years) were enrolled in this study. The portal hypertension group included patients who underwent splenectomy and pericardial blood vessel disarticulation at our hospital from October 2010 to March 2011. One week before surgery, patients with portal hypertension underwent preoperative liver contrast-enhanced sonography. Two-dimensional, Doppler, and contrast-enhanced sonographic parameters were compared between the groups. Portal venous pressure was measured intraoperatively by portal vein puncture in the portal hypertension group, and its relationship with the other parameters was analyzed. RESULTS: The 2-dimensional, Doppler, and contrast-enhanced sonographic parameters differed between the groups (P < .01). Portal venous pressure was inversely correlated with the area under the portal vein/hepatic artery time-intensity curve ratio (Qp/Qa), portal vein/hepatic artery strength ratio (Ip/Ia), and portal vein/hepatic artery wash-in perfusion slope ratio (ßp/ßa), with correlation coefficients of -0.701, -0.625, and -0.494, respectively. CONCLUSIONS: Measurement of the liver contrast-enhanced sonographic parameters Qp/Qa, Ip/Ia, and ßp/ßa could be used as a new quantitative method for noninvasively assessing portal venous pressure.


Asunto(s)
Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Cirrosis Hepática/diagnóstico por imagen , Fosfolípidos , Hexafluoruro de Azufre , Ultrasonografía/métodos , Adulto , Determinación de la Presión Sanguínea/métodos , Medios de Contraste , Estudios de Factibilidad , Humanos , Hipertensión Portal/etiología , Cirrosis Hepática/complicaciones , Cirrosis Hepática/fisiopatología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Presión Venosa
3.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 35(4): 411-5, 2013 Aug.
Artículo en Zh | MEDLINE | ID: mdl-23987488

RESUMEN

OBJECTIVE: To prepare a lymph node-targeted ultrasound/fluorescence bi-functional imaging contrast agents, and observe its effectiveness both on contrast-enhanced ultrasound (CEUS) and vivo near infrared fluorescence (NIR) imaging through animal experiments. METHODS: The chimeric lymph node-targeted ligand (phosphatidylserine) and near-infrared fluorescent substance were assembled to form bi-functional contrast microbubbles. The morphology and size distribution were detected by optical microscope and Malvern potential tests. Five normal New Zealand white rabbits were subcutaneously injected with the prepared contrast agent in bilateral footpads, and the imaging effectiveness of lymph nodes and lymphatic vessel were observed by CEUS and NIR technique. Then blue dye was subcutaneously injected at the same site, and the rabbits were sacrificed for lymph nodes pathological examination. RESULTS: Lipid ultrasound microbubbles,with a mean size of 3-5 Μm in diameter, appeared to be uniform in distribution and regular in configuration. The images of inflow lymphatic vessel and relevant lymph node were quickly showed up after the subcutaneous injection by CEUS, which was identical to the result detected by NIR. Biopsy confirmed that all the blue-stained lymph nodes could be displayed by NIR. CONCLUSIONS: The self-made bi-functional contrast agent has a good imaging ability in CEUS and NIR imaging. It may be a better agent as lymph node tracer.


Asunto(s)
Medios de Contraste/química , Ganglios Linfáticos/diagnóstico por imagen , Animales , Fluoresceínas/química , Ganglios Linfáticos/anatomía & histología , Metástasis Linfática/patología , Masculino , Conejos , Ultrasonografía
4.
PLoS One ; 9(9): e105795, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25192214

RESUMEN

Ischemic-type biliary lesions (ITBLs) are a major cause of graft loss and mortality after orthotopic liver transplantation (OLT). Impaired blood supply to the bile ducts may cause focal or extensive damage, resulting in intra- or extrahepatic bile duct strictures or dilatations that can be detected by ultrasonography, computed tomography, magnetic resonance cholangiopancreatography, and cholangiography. However, the radiographic changes occur at an advanced stage, after the optimal period for therapeutic intervention. Endoscopic retrograde cholangio-pancreatography (ERCP) and percutaneous transhepatic cholangiodrainage (PTCD) are the gold standard methods of detecting ITBLs, but these procedures cannot be used for continuous monitoring. Traditional methods of follow-up and diagnosis result in delayed diagnosis and treatment of ITBLs. Our center has used the early diagnosis and intervention model (EDIM) for the diagnosis and treatment of ITBLs since February 2008. This model mainly involves preventive medication to protect the epithelial cellular membrane of the bile ducts, regular testing of liver function, and weekly monitor of contrast-enhanced ultrasonography (CEUS) to detect ischemic changes to the bile ducts. If the liver enzyme levels become abnormal or CEUS shows low or no enhancement of the wall of the hilar bile duct during the arterial phase, early ERCP and PTCD are performed to confirm the diagnosis and to maintain biliary drainage. Compared with patients treated by the traditional model used prior to February 2008, patients in the EDIM group had a lower incidence of biliary tract infection (28.6% vs. 48.6%, P = 0.04), longer survival time of liver grafts (24±9.6 months vs. 17±12.3 months, P = 0.02), and better outcomes after treatment of ITBLs.


Asunto(s)
Enfermedades de los Conductos Biliares/diagnóstico , Enfermedades de los Conductos Biliares/terapia , Isquemia/complicaciones , Trasplante de Hígado/efectos adversos , Complicaciones Posoperatorias , Adulto , Algoritmos , Enfermedades de los Conductos Biliares/etiología , Colangiopancreatografia Retrógrada Endoscópica , Femenino , Estudios de Seguimiento , Supervivencia de Injerto , Humanos , Trasplante de Hígado/mortalidad , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Estudios Retrospectivos , Factores de Tiempo , Ultrasonografía
5.
J Mater Chem B ; 2(2): 217-223, 2014 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-32261609

RESUMEN

A novel multifunctional theranostic agent has been successfully fabricated by loading iron oxide nanoparticles into poly(lactic acid) (PLA) microcapsules followed by surface functionalization with graphene oxide. Both in vitro and in vivo experiments proved that the resulting microcapsules could serve as contrast agents to simultaneously enhance ultrasound, magnetic resonance and photoacoustic imaging. The composite microcapsules show good biocompatibility and rapid response to magnetic fields. Due to the strong absorption of the near-infrared light, the composite microcapsules could efficiently kill cancer cells upon NIR laser irradiation. In addition, it was found that such a photothermal effect could be obviously enhanced by applying an external magnetic field. In a nutshell, this multifunctional microcapsule can be developed as a promising platform that integrates multimodality imaging and therapy capabilities for effective cancer theranostics.

6.
Artículo en Inglés | WPRIM | ID: wpr-299383

RESUMEN

<p><b>OBJECTIVE</b>To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis.</p><p><b>METHODS</b>86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to August 2009. The patients were classified into 5 groups (S(0)-S(4)) according to fibrosis stage evaluated with ultrasound guided liver biopsy. New contrast-enhanced ultrasonography (CEUS) features including area under the time-intensity curve (TIC) of portal venous phase/hepatic arterial phase (Qp/Qa) and intensity of portal venous phase/hepatic arterial phase (Ip/Ia) were used to detect the blood supply ratio (portal vein/hepatic artery) in each group. Arrival time of portal vein trunk (Tp) and decreasing rate of TIC (β) were also analyzed.</p><p><b>RESULTS</b>Qp/Qa and Ip/Ia decreased from S(0) to S(4), while Tp and β increased. These 4 features were significantly correlated with the degree of fibrosis (P<0.001) and were significantly different among the five groups (P<0.001). Sensitivity and specificity of Ip/Ia were 80% and 86% for groups ≥S(1), 75% and 86% for groups ≥ S(2), 71% and 84% for groups ≥ S(3), and 76% and 80% for group S(4), respectively. Sensitivity and specificity of Qp/Qa were 70% and 88% for groups ≥ S(1), 80% and 76% for groups ≥ S(2), 74% and 70% for groups ≥ S(3), and 81% and 95% for group S(4), respectively.</p><p><b>CONCLUSION</b>Ip/Ia and Qp/Qa could be adopted as reliable, non-invasive features for quantitative assessment of hepatic fibrosis.</p>


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medios de Contraste , Aumento de la Imagen , Cirrosis Hepática , Diagnóstico por Imagen , Tomografía Computarizada por Rayos X , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA