Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Más filtros

Intervalo de año de publicación
1.
Am J Dent ; 33(4): 213-217, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32794397

RESUMEN

PURPOSE: To perform a clinical and radiographic evaluation comparing Filtek Bulk Fill high viscosity bulk-fill resins with Filtek Z350 XT nanoparticulate for 1 year. METHODS: 58 restorations were performed for each material (bulk-fill and nanoparticulate), for a total of 116 restorations. Among these, 42 Class I and 16 Class II restorations were performed for each group, in molars and premolars. Clinical evaluation was performed 7 days (baseline), 6 months and 1 year after restorations, using the World Dental Federation (FDI) criteria. Radiographs were obtained at 7 days and 1 year after the restoration was placed and the radiopacity was measured using Image J software at the same time interval. RESULTS: Of the 70 restorations available for evaluation at 1 year, the Mann-Whitney and Friedman tests showed no statistically significant difference for the FDI criteria analyzed. Greater radiopacity was observed for bulk-fill resin compared to nanoparticulate (two-way ANOVA, P= 0.022). This same test showed no difference in radiopacity between the groups in the two evaluation periods (P= 0.062). The high viscosity bulk-fill resin composite presented similar clinical performance to nanoparticulate resin in this evaluation period and higher radiopacity was observed for this material when compared to nanoparticulate resin, in both time periods. CLINICAL SIGNIFICANCE: The high viscosity bulk-fill resin composite showed similar performance to the nanoparticulate resin during the evaluation period of 1 year. Radiopacity showed high values for the bulk-fill resin when compared to nanoparticulate resin. The bulk-fill resin has potential to be used in posterior teeth.


Asunto(s)
Materiales Dentales , Restauración Dental Permanente , Diente Premolar , Resinas Compuestas , Diente Molar , Viscosidad
2.
J Esthet Restor Dent ; 32(3): 325-332, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31622014

RESUMEN

OBJECTIVE: To evaluate the influence of the degree of dentin moisture on interfacial ultramorphology and bond strength (µTBS) of universal adhesives. MATERIALS AND METHODS: Futurabond U (FBU), Scotchbond Universal (SBU), Adhese Universal (ADU), and Prime&Bond active (PBA) were used. After acid-etching, moist or over-dried dentin surfaces were tested. Teeth were restored for scanning and transmission electron microscopy (n = 3) and µTBS evaluation (n = 5). µTBS results were analyzed by two-way ANOVA and Tukey. RESULTS: For moist dentin, a well-formed hybrid layer (HL) was observed. However, when applied to over-dried dentin, remarkable differences were observed. Defects, gaps, and reduced HL thickness were observed mainly for ADU and FBU. When applied to wet dentin, µTBS values were similar for all adhesives, except for FBU, which was significantly lower. When applied to over-dried dentin, PBA presented the highest µTBS values, followed by SBU, ADU, and FBU. ADU presented significantly lower µTBS when applied to over-dried dentin. CONCLUSION: PBA, SBU, and FBU µTBS values were not sensitive to the degree of moisture. Even though application to over-dried dentin revealed defects, gaps and reduced HL thickness for SBU, ADU, and FBU, µTBS analysis only revealed a significant reduction for ADU. CLINICAL SIGNIFICANCE: Universal adhesives can be applied in either self-etching or etch-and-rinse mode. However, clinicians are not aware which universal adhesives should be strictly applied on a moist dentin for bonding in the etch-and-rinse mode.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Resinas Compuestas , Cementos Dentales , Dentina , Ensayo de Materiales , Cementos de Resina , Resistencia a la Tracción
3.
J Esthet Restor Dent ; 30(4): 346-351, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29766651

RESUMEN

OBJECTIVE: To test the effects of different adhesive protocols and silane application on the adhesive durability to a Lithium Disilicate reinforced glass ceramic. METHODS: Forty disks of 13 mm diameter (E.max Press) were used. After etching with 9.5% HF for 20 seconds, disks were randomly assigned into 4 groups according to the adhesive/silane protocol: silane application only (SIL); silane application followed by adhesive (SILXP-XP Bond); silane-containing adhesive (SBU-ScotchBond Universal); silane application followed by silane-containing adhesive (SILSBU). Four resin composite cylinders of 1-mm diameter and 3-mm height were made on each ceramic disk and tested in shear. Specimens were stored in water for 24 hours or 12 months prior to testing. Results were statistically analyzed by two-way ANOVA and Tukey test. RESULTS: After 24 hours, the highest SBS values were observed for SILXP and SILSBU. However, after 12 months, SILXP and SILSBU presented a significant reduction in SBS, while the highest SBS were observed for SIL. For SBU, no significant reduction in SBS was observed, however, it showed the lowest SBS after 12 months. CONCLUSIONS: Regardless of the presence of silane in the composition of SBU, previous silane application is still recommended prior to cementation of Lithium Disilicate. CLINICAL SIGNIFICANCE: The application of silane as a separate step is recommended prior to cementation of Lithium Disilicate reinforced glass-ceramic, independent of the presence of silane within the universal adhesive solution.


Asunto(s)
Recubrimiento Dental Adhesivo , Silanos , Cerámica , Cementos Dentales , Porcelana Dental , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie
4.
J Esthet Restor Dent ; 29(2): 118-127, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27925387

RESUMEN

PURPOSE: This study aimed to quantify polymerization shrinkage of one conventional and three bulk-fill composites, under bonded and unbonded conditions, in Class II preparations using 3D microcomputed tomography (µCT) and report its location. MATERIALS AND METHODS: Preparations (2.5 mm occlusal depth × 4 mm wide × 4 mm mesial box and 1 mm beyond the CEJ distal box depth) were made in 48 human extracted molars (n = 6). Four composites were tested, one regular (Vitalescence/VIT) and three bulk-fill: SureFil SDR Flow (SDR), Tetric EvoCeram Bulk Fill (TET), and Filtek flowable Bulk Fill (FIL). Teeth were divided into four groups according to restorative material used and subdivided into two subgroups, according to the presence of an adhesive system (XP Bond) application (bonded [-B]) or its absence (unbonded [-U]). Each tooth was scanned three times: (1) after cavity preparation, (2) before and (3) after composite light-curing. Acquired µCT images were imported into 2D and 3D software for analysis. RESULTS: Significantly different volumetric shrinkage between bonded and unbonded conditions was observed only for TET group (p < 0.05), unbonded presenting significantly higher volumetric shrinkage. Among the bonded groups, TET-B presented significantly lower shrinkage than both SDR-B and FIL-B but not significantly different from VIT-B. Generally, shrinkage occurred at occlusal and distal surfaces. CONCLUSIONS: When applied to bonded Class II cavities, TET exhibited significantly lower volumetric shrinkage compared to the other bulk-fill composites. However, it also exhibited the highest difference of volumetric shrinkage values between unbonded and bonded cavities. CLINICAL SIGNIFICANCE: Volumetric polymerization shrinkage occurred with all composites tested, regardless of material type (conventional or bulk-fill) or presence or absence of bonding. However, volumetric shrinkage has been reduced or at least maintained when bulk-fill composites were used compared to a conventional composite resin, which makes them a potential time saving alternative for clinicians. (J Esthet Restor Dent 29:118-127, 2017).


Asunto(s)
Caries Dental/diagnóstico por imagen , Caries Dental/patología , Microtomografía por Rayos X/métodos , Resinas Compuestas/química , Humanos , Polimerizacion
5.
Br J Nutr ; 112(8): 1235-50, 2014 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-25192422

RESUMEN

Different dietary interventions have been identified as potential modifiers of adiponectin concentrations, and they may be influenced by lipid intake. We identified studies investigating the effect of dietary lipids (type/amount) on adiponectin concentrations in a systematic review with meta-analysis. A literature search was conducted until July 2013 using databases such as Medline, Embase and Scopus (MeSH terms: 'adiponectin', 'dietary lipid', 'randomized controlled trials (RCT)'). Inclusion criteria were RCT in adults analysing adiponectin concentrations with modification of dietary lipids. Among the 4930 studies retrieved, fifty-three fulfilled the inclusion criteria and were grouped as follows: (1) total dietary lipid intake; (2) dietary/supplementary n-3 PUFA; (3) conjugated linoleic acid (CLA) supplementation; (4) other dietary lipid interventions. Diets with a low fat content in comparison to diets with a high-fat content were not associated with positive changes in adiponectin concentrations (twelve studies; pooled estimate of the difference in means: -0·04 (95% CI -0·82, 0·74) µg/ml). A modest increase in adiponectin concentrations with n-3 PUFA supplementation was observed (thirteen studies; 0·27 (95% CI 0·07, 0·47) µg/ml). Publication bias was found by using Egger's test (P= 0·01) and funnel plot asymmetry. In contrast, CLA supplementation reduced the circulating concentrations of adiponectin compared with unsaturated fat supplementation (seven studies; -0·74 (95% CI -1·38, -0·10) µg/ml). However, important sources of heterogeneity were found as revealed by the meta-regression analyses of both n-3 PUFA and CLA supplementation. Results of new RCT would be necessary to confirm these findings.


Asunto(s)
Adiponectina/sangre , Grasas de la Dieta/administración & dosificación , Regulación hacia Arriba , Adiponectina/agonistas , Adulto , Dieta con Restricción de Grasas , Dieta Alta en Grasa/efectos adversos , Grasas de la Dieta/uso terapéutico , Suplementos Dietéticos/efectos adversos , Regulación hacia Abajo , Ácidos Grasos Omega-3/uso terapéutico , Humanos , Ácidos Linoleicos Conjugados/efectos adversos , Ácidos Linoleicos Conjugados/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Reproducibilidad de los Resultados
6.
BMC Psychiatry ; 13: 60, 2013 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-23418863

RESUMEN

BACKGROUND: Patients with schizophrenia have lower longevity than the general population as a consequence of a combination of risk factors connected to the disease, lifestyle and the use of medications, which are related to weight gain. METHODS: A multicentric, randomized, controlled-trial was conducted to test the efficacy of a 12-week group Lifestyle Wellness Program (LWP). The program consists of a one-hour weekly session to discuss topics like dietary choices, lifestyle, physical activity and self-esteem with patients and their relatives. Patients were randomized into two groups: standard care (SC) and standard care plus intervention (LWP). Primary outcome was defined as the weight and body mass index (BMI). RESULTS: 160 patients participated in the study (81 in the intervention group and 79 in the SC group). On an intent to treat analysis, after three months the patients in the intervention group presented a decrease of 0.48 kg (CI 95% -0.65 to 1.13) while the standard care group showed an increase of 0.48 kg (CI 95% 0.13 to 0.83; p=0.055). At six-month follow-up, there was a significant weight decrease of -1.15 kg, (CI 95% -2.11 to 0.19) in the intervention group compared to a weight increase in the standard care group (+0.5 kg, CI 95% -0.42-1.42, p=0.017). CONCLUSION: In conclusion, this was a multicentric randomized clinical trial with a lifestyle intervention for individuals with schizophrenia, where the intervention group maintained weight and presented a tendency to decrease weight after 6 months. It is reasonable to suppose that lifestyle interventions may be important long-term strategies to avoid the tendency of these individuals to increase weight.


Asunto(s)
Obesidad/prevención & control , Esquizofrenia/complicaciones , Adulto , Antipsicóticos/efectos adversos , Antipsicóticos/uso terapéutico , Índice de Masa Corporal , Peso Corporal/efectos de los fármacos , Femenino , Humanos , Estilo de Vida , Masculino , Obesidad/inducido químicamente , Cooperación del Paciente , Escalas de Valoración Psiquiátrica , Esquizofrenia/tratamiento farmacológico , Encuestas y Cuestionarios , Aumento de Peso/efectos de los fármacos
7.
Am J Dent ; 26(6): 335-40, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24640438

RESUMEN

PURPOSE: To determine the bond strength, nanoleakage and interfacial morphology of four self-etch adhesives bonded to superficial dentin. METHODS: Microtensile (MT) (n= 15) and single plane shear (SP) (n= 8) bond tests were performed using human dentin polished through 320-grit SiC paper. Clearfil Protect Bond (PB), Clearfil S3 Bond (S3), Prompt L-Pop (PLP) and G-Bond (GB) were used according to their manufacturers' instructions. Composite was applied as cylinders with a thickness of 4 mm with a 1 mm diameter and stored in water at 370C for 24 hours. Specimens were debonded with a testing machine at a cross-head speed of 1 mm/minute. Means and standard deviations of bond strength were calculated. Data were analyzed using ANOVA. Fisher's PLSD intervals were calculated at the 0.05 level of significance. Failure modes were determined at x100. The hybrid layer was revealed by treatment with 5N HC1/5% NaOCl or fractured perpendicular to the interface and sputter coated with gold. Specimens were viewed at x1,000, x2,500, and x5,000 in a field emission SEM at 15 kV. Teeth (n=2) sectioned into 0.9 mm-thick slabs were immersed in ammoniacal silver nitrate solution for 24 hours, rinsed and immersed in photo-developing solution for 8 hours. Specimens were sectioned (90 nm-thick) and observed under TEM. RESULTS: Means ranged from 25.0 to 73.1 MPa for MT and from 15.5 to 56.4 MPa for SP. MT values were greater than SP, but were highly correlated (R2 = 0.99, P= 0.003) and provided the same order for the systems studied. Fisher's PLSD intervals (P< 0.05) for bond strength techniques and adhesives results were 1.7 and 2.3 MPa, respectively. Failures sites were mixed. TEM showed that hybrid layers were -0.5 pm for PB, GB and S3 and approximately 5 microm for PLP. SEM showed morphologic differences among adhesives. Silver nitrate deposits were observed within the interfaces for all adhesive systems.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios/química , Resinas Compuestas/química , Filtración Dental/clasificación , Materiales Dentales/química , Análisis del Estrés Dental/instrumentación , Dentina/ultraestructura , Humanos , Ensayo de Materiales , Metacrilatos/química , Microscopía Electrónica de Rastreo , Microscopía Electrónica de Transmisión , Cementos de Resina/química , Resistencia al Corte , Tinción con Nitrato de Plata , Estrés Mecánico , Propiedades de Superficie , Temperatura , Resistencia a la Tracción , Factores de Tiempo , Agua/química
8.
J Adhes Dent ; 14(3): 251-63, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22282747

RESUMEN

PURPOSE: This study evaluated the effects of peripheral enamel margins on the long-term bond strength (µTBS) and nanoleakage in resin/dentin interfaces produced by self-adhesive and conventional resin cements. MATERIALS AND METHODS: Five self-adhesive [RelyX-Unicem (UN), RelyX-U100 (UC), GCem (GC), Maxcem (MC), Set (SET)] and 2 conventional resin cements [RelyX-ARC(RX), Panavia F(PF)] were used. An additional group included the use of a two-step self-etching adhesive (SE Bond) with Panavia F (PS). One hundred ninety-two molars were assigned to 8 groups according to luting material. Five-mm-thick composite disks were cemented and assigned to 3 subgroups according to water-exposure condition (n = 6): 24-h peripheral exposure (24h-PE-enamel margins), or 1 year of peripheral (1 yr-PE) or direct exposure (1 yr-DE-dentin margin). Restored teeth were sectioned into beams and tested in tension at 1 mm/min. Data were analyzed by two-way ANOVA and Tukey's test. Two additional specimens in each group were prepared for nanoleakage evaluation. Nanoleakage patterns were observed under SEM/TEM. RESULTS: Except for RX, no significant reduction in µTBS was observed between 24h-PE and 1 yr-PE. 1 yr-DE reduced µTBS for RX, PF, GC, MC, and SET. No significant reduction in µTBS was observed for PS, UC, and UN after 1 year. After 1 yr-DE, RX and PS presented the highest µTBS, and SET and MC the lowest. Nanoleakage was reduced when there was a peripheral enamel margin. SET and MC presented more silver deposition than other groups. CONCLUSION: The presence of a peripheral enamel margin reduced the degradation rate in resin/dentin interfaces for most materials. The µTBS values produced by the multi-step luting agents RX and PS were significantly higher than those observed for self-adhesive cement.


Asunto(s)
Recubrimiento Dental Adhesivo , Filtración Dental , Cementos de Resina/química , Análisis de Varianza , Resinas Compuestas , Recubrimiento Dental Adhesivo/métodos , Esmalte Dental , Análisis del Estrés Dental , Dentina , Humanos , Ensayo de Materiales , Microscopía Electrónica , Diente Molar , Estadísticas no Paramétricas , Resistencia a la Tracción , Agua
9.
Artículo en Inglés | MEDLINE | ID: mdl-35551682

RESUMEN

Maturity-onset diabetes of the young (MODY) is a heterogeneous group of monogenic forms of diabetes mellitus with distinct clinical features. Clinical dermatological phenotypes in MODY patients are very rare in literature. This report describes a patient with HNF1A-MODY presenting with necrobiosis lipoidica (NL) and granuloma annulare (GA). A 39-year-old asymptomatic woman, with atypical diabetes diagnosed at age 17, has a confirmed HNF1A mutation on exon 2 (c.392G>A, p.R131Q), classified as Pathogenic by the ACMG guidelines. She has reasonable metabolic control using oral anti-diabetic medications and has no chronic diabetic complications. Clinical and histologic diagnoses of both NL and GA were made. We discuss these conditions and their association with MODY.

10.
Front Plant Sci ; 13: 849896, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35574134

RESUMEN

Limited knowledge about how nitrogen (N) dynamics are affected by climate change, weather variability, and crop management is a major barrier to improving the productivity and environmental performance of soybean-based cropping systems. To fill this knowledge gap, we created a systems understanding of agroecosystem N dynamics and quantified the impact of controllable (management) and uncontrollable (weather, climate) factors on N fluxes and soybean yields. We performed a simulation experiment across 10 soybean production environments in the United States using the Agricultural Production Systems sIMulator (APSIM) model and future climate projections from five global circulation models. Climate change (2020-2080) increased N mineralization (24%) and N2O emissions (19%) but decreased N fixation (32%), seed N (20%), and yields (19%). Soil and crop management practices altered N fluxes at a similar magnitude as climate change but in many different directions, revealing opportunities to improve soybean systems' performance. Among many practices explored, we identified two solutions with great potential: improved residue management (short-term) and water management (long-term). Inter-annual weather variability and management practices affected soybean yield less than N fluxes, which creates opportunities to manage N fluxes without compromising yields, especially in regions with adequate to excess soil moisture. This work provides actionable results (tradeoffs, synergies, directions) to inform decision-making for adapting crop management in a changing climate to improve soybean production systems.

11.
Pediatr Diabetes ; 12(3 Pt 1): 187-91, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21518408

RESUMEN

Wolcott-Rallison syndrome (WRS, OMIM 226980) is a rare autosomal recessive disorder characterized by permanent neonatal diabetes mellitus, epiphyseal dysplasia, and other multisystemic clinical manifestations. We described two novel mutations in the EIF2AK3 gene in two consanguineous families with WRS from Brazil and Morocco. We have observed in case 1 a homozygous C > T replacement at base pair c.1192 at exon 7, generating a stop codon at position 398 (Gln398Stop). Both of his parents were found to be heterozygous for the mutation. We detected in both parents of case 2, a deceased Moroccan girl, a duplication of base pair c.851A at exon 5 (c.851dupA) leading to a frameshift and a stop codon at position 285 (p.Pro285AlafsX3). Both cases 1 and 2 had neonatal diabetes mellitus, multiple epiphyseal dysplasia, and growth delay, and presented episodes of acute hepatic dysfunction. Case 1 presented central hypothyroidism, developmental delay, and mild mental retardation. Case 2 presented a fatal episode of acute renal failure. The clinical phenotype associated with the syndrome can be variable, but a combination of infancy-onset diabetes mellitus, multiple epiphyseal dysplasia, and hepatic and/or renal dysfunction is the mainstay of diagnosis.


Asunto(s)
Mutación Puntual , eIF-2 Quinasa/genética , Brasil , Niño , Preescolar , Diabetes Mellitus Tipo 1/genética , Epífisis/anomalías , Salud de la Familia , Resultado Fatal , Femenino , Genes Recesivos , Humanos , Masculino , Marruecos , Osteocondrodisplasias/genética
12.
BMC Res Notes ; 14(1): 327, 2021 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-34446061

RESUMEN

OBJECTIVES: This data article aims to introduce the "XPolaris" R-package, designed to facilitate access to detailed soil data at any geographical location within the contiguous United States (CONUS). Without the need of advanced R-programming skills, XPolaris enables users to convert raster data from the POLARIS database into traditional spreadsheet format [i.e., Comma-Separated Values (CSV)] for further data analyses. DATA DESCRIPTION: The core of this publication is a code-tutorial envisioned to assist users in retrieving soil raster data within the CONUS. All data is sourced from the POLARIS database, a 30-m probabilistic map of soil series and different soil properties [Chaney et al. Geoderma 274:54, 2016, Chaney et al. Water Resour Res 55:2916, 2019]. POLARIS represents an optimization of the Soil Survey Geographic (SSURGO) database, circumventing issues of spatial disaggregation, harmonizing, and filling spatial gaps. POLARIS was constructed using a machine learning algorithm, the Disaggregation and Harmonisation of Soil Map Units Through Resampled Classification Trees (DSMART-HPC) [Odgers et al. Geoderma 214:91, 2014]. Although the data is easily accessible in a raster format, retrieving large amounts of data can be time-consuming or require advanced programming skills.


Asunto(s)
Algoritmos , Suelo , Estados Unidos
13.
Diabetes Res Clin Pract ; 176: 108867, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34023340

RESUMEN

AIMS: Maturity-Onset Diabetes of the Young (MODY) caused by glucokinase (GCK) mutations is characterized by lifelong mild non-progressive hyperglycemia, with low frequency of coronary artery disease (CAD) compared to other types of diabetes. The aim of this study is to estimate cardiovascular risk by coronary artery calcification (CAC) score in this group. MATERIALS AND METHODS: Twenty-nine GCK-MODY cases, 26 normoglycemic controls (recruited among non-affected relatives/spouses of GCK mutation carriers), and 24 unrelated individuals with type 2 diabetes were studied. Patients underwent CAC score evaluation by computed tomography and were classified by Agatston score ≥ or < 10. Framingham Risk scores of CAD in 10 years were calculated. RESULTS: Median [interquartile range] CAC score in GCK-MODY was 0 [0,0], similar to controls (0 [0,0], P = 0.49), but lower than type 2 diabetes (39 [0, 126], P = 2.6 × 10-5). A CAC score ≥ 10 was seen in 6.9% of the GCK group, 7.7% of Controls (P = 1.0), and 54.2% of individuals with type 2 diabetes (P = 0.0006). Median Framingham risk score was lower in GCK than type 2 diabetes (3% vs. 13%, P = 4 × 10-6), but similar to controls (3% vs. 4%, P = 0.66). CONCLUSIONS: CAC score in GCK-MODY is similar to control individuals from the same family and/or household and is significantly lower than type 2 diabetes. Besides demonstrating low risk of CAD in GCK-MODY, these findings may contribute to understanding the specific effect of hyperglycemia in CAD.


Asunto(s)
Calcio/sangre , Vasos Coronarios/metabolismo , Diabetes Mellitus Tipo 2/diagnóstico , Factores de Riesgo de Enfermedad Cardiaca , Adulto , Anciano , Calcio/análisis , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/etiología , Estudios de Casos y Controles , Vasos Coronarios/química , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/genética , Angiopatías Diabéticas/sangre , Angiopatías Diabéticas/diagnóstico , Femenino , Glucoquinasa/genética , Humanos , Hiperglucemia/genética , Masculino , Persona de Mediana Edad , Mutación , Pronóstico , Medición de Riesgo , Factores de Riesgo
14.
Acta Odontol Latinoam ; 34(2): 173-182, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34570866

RESUMEN

The aim of this study was to compare low- and high-viscosity bulk-fill composites for Knoop microhardness (KHN), microtensile bond strength (MTBS) to dentin in occlusal cavities, and fracture strength (FS) in molars with mesialocclusal- distal restoration. Disk-shaped samples with different thicknesses (2 or 4 mm) of low-viscosity (SDR Flow, Dentsply) and high-viscosity bulk-fill composites (Filtek BulkFill, 3M ESPE; and Tetric-N Ceram Bulk Fill, Ivoclar Vivadent) were prepared for top and bottom KHN analysis (n=10). MTBS to dentin and fracture pattern was evaluated in human molars with occlusal cavities restored with (n=10): conventional nanocomposite (Z350XT, 3M ESPE), low-viscosity (Filtek Bulk-fill Flow, 3M ESPE) or high-viscosity bulk-fill composites (Filtek BulkFill). The FS and fracture pattern of human molar with mesial-occlusal-distal restorations submitted or not to thermomechanical cycling were investigated (n=10) using: intact tooth (control), and restoration based on conventional microhybrid composite (Z250, 3M ESPE), low-viscosity (SDR Flow) or high-viscosity bulk-fill composites (Filtek BulkFill). The data were submitted to split-plot ANOVA (KHN), one-way ANOVA (MTBS), two-way ANOVA (FS) followed by Tukey's test (α=0.05). For KHN, there was no significant difference for the resin composites between the top and bottom. For MTBS, no significant differences among the materials were detected; however, the low-viscosity composite presented lower frequency of adhesive failures. For FS, there was no significant difference between composites and intact tooth regardless of thermomechanical cycling. Low- and high-viscosity bulk-fill composites have comparable microhardness and microtensile bond strength when used in occlusal restorations. Likewise, the bulk-fill composites present similar fracture strength in molars with mesio-occlusal-distal restorations.


O objetivo deste estudo foi comparar resinas compostas bulk- -fill de baixa e alta viscosidade quanto à microdureza Knoop (KHN), resistência de união a microtração (MTBS) em cavidades oclusais e carga à fratura (FS) em molares com restauração mesio-oclusal-distal. Amostras em forma de disco com diferentes espessuras (2 ou 4 mm) de resinas bulk-fill de baixa viscosidade (SDR Flow, Dentsply) e alta viscosidade (Filtek BulkFill, 3M ESPE; e Tetric-N Ceram Bulk Fill, Ivoclar Vivadent) foram obtidas para análise de KHN no topo e na base (n = 10). A MTBS em dentina e o padrão de fratura foram avaliados em molares humanos com cavidades oclusais restauradas com (n = 10): resina composta nanoparticulada convencional (Z350XT, 3M ESPE), resinas bulk-fill de baixa viscosidade (Filtek Bulk-fill Flow, 3M ESPE) ou alta viscosidade (Filtek BulkFill). Foram investigados a FS e o padrão de fratura de molares humanos em restaurações mesial-ocluso-distais sub metidas ou não à ciclagem termomecânica (n = 10), sendo: dente íntegro (controle), e restaurações baseadas em resina composta microhíbrida convencional (Z250, 3M ESPE); resinas bulk-fill de baixa viscosidade (SDR Flow) ou alta viscosidade (Filtek BulkFill). Os dados foram submetidos a split-plot ANOVA (KHN), one-way ANOVA (MTBS), two-way ANOVA (FS) seguidos do teste de Tukey (α = 0,05). Para KHN, não houve diferença significativa entre o topo e a base para as resinas compostas. Para MTBS, não foram detectadas diferenças significativas entre os materiais; entretanto, a resina bulk-fill de baixa viscosidade apresentou menor frequência de falhas adesivas. Para FS, não houve diferença significativa entre os materiais e o dente íntegro, independentemente da ciclagem termomecânica. As resinas bulk-fill de baixa e alta viscosidade têm microdureza e resistência à microtração comparáveis quando usados em restaurações oclusais. Da mesma forma, as resinas bulk-fill apresentam resistência à fratura semelhante em molares com restaurações mesio-oclusal-distais.


Asunto(s)
Resinas Compuestas , Resistencia Flexional , Humanos , Ensayo de Materiales , Diente Molar , Viscosidad
15.
Oper Dent ; 35(4): 448-53, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20672730

RESUMEN

The antibacterial properties of self-etching adhesive systems constitute an important issue in operative dentistry, since viable bacteria can still be present after cavity preparation. The current study evaluated the antibacterial activity of five one-step self-etching adhesives (SEAs) and four self-etching primers (SEPs) against oral streptococci. Clearfil S3 (S3), One-Up Bond F Plus (OU), Futurabond NR (FB), GBond (GB), Xeno IV (X4), Clearfil SE Bond (SE), Clearfil Protect Bond (PB), Adper SE Plus (AS) and AdheSE (AD) were tested for antibacterial activity against five streptococci species: S oralis, S sanguinis, S cricetus, S mutans and S sobrinus. Chlorhexidine (0.12%) and phosphoric acid (37%) gel were used as control. The agar diffusion test method was used. Plates containing BHI agar and 300 uL of bacterial cell suspension (0.5 MacFarland) were prepared. Holes 6 mm in diameter were made and partially filled with bacteriological agar. Then, 10 uL of each SEA or SEP was dropped and the plates were incubated under microaerophilic atmosphere at 37 degrees C for 48 hours and the diameter of each halo was registered. The results were analyzed by two-way ANOVA and Tukey test. PB exhibited the most effective antibacterial activity against oral streptococci. The performances of SE and FB were similar or better than chlorhexidine for all bacteria. S3, X4, AS, AD, OU and GB showed significantly lower inhibition values. Among the species tested, S oralis was the most sensitive to all self-etching adhesive systems; on the other hand, S cricetus, S mutans and S sobrinus were more resistant. Among the self-etching adhesive systems evaluated, Clearfil Protect Bond exhibited the most effective antibacterial activity against oral streptococci.


Asunto(s)
Antibacterianos/farmacología , Recubrimientos Dentinarios/farmacología , Boca/microbiología , Cementos de Resina/farmacología , Streptococcus/efectos de los fármacos , Resinas Acrílicas/farmacología , Antiinfecciosos Locales/farmacología , Clorhexidina/farmacología , Humanos , Ensayo de Materiales , Metacrilatos/farmacología , Ácidos Fosfóricos/farmacología , Streptococcus/clasificación , Streptococcus mutans/efectos de los fármacos , Streptococcus oralis/efectos de los fármacos , Streptococcus sobrinus/efectos de los fármacos
16.
Diabetol Metab Syndr ; 12: 50, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32528556

RESUMEN

BACKGROUND: Maturity-onset diabetes of the young (MODY) is the most common type of monogenic diabetes, being characterized by beta-cell disfunction, early onset, and autosomal dominant inheritance. Despite the rapid evolution of molecular diagnosis methods, many MODY cases are misdiagnosed as type 1 or type 2 diabetes. High costs of genetic testing and limited knowledge of MODY as a relevant clinical entity are some of the obstacles that hinder correct MODY diagnosis and treatment. We present a broad review of clinical syndromes related to most common MODY subtypes, emphasizing the role of biomarkers that can help improving the accuracy of clinical selection of candidates for molecular diagnosis. MAIN BODY: To date, MODY-related mutations have been reported in at least 14 different genes. Mutations in glucokinase (GCK), hepatocyte nuclear factor-1 homeobox A (HNF1A), and hepatocyte nuclear factor-4 homeobox A (HNF4A) are the most common causes of MODY. Accurate etiological diagnosis can be challenging. Many biomarkers such as apolipoprotein-M (ApoM), aminoaciduria, complement components, and glycosuria have been tested, but have not translated into helpful diagnostic tools. High-sensitivity C-reactive protein (hs-CRP) levels are lower in HNF1A-MODY and have been tested in some studies to discriminate HNF1A-MODY from other types of diabetes, although more data are needed. Overall, presence of pancreatic residual function and absence of islet autoimmunity seem the most promising clinical instruments to select patients for further investigation. CONCLUSIONS: The selection of diabetic patients for genetic testing is an ongoing challenge. Metabolic profiling, diabetes onset age, pancreatic antibodies, and C-peptide seem to be useful tools to better select patients for genetic testing. Further studies are needed to define cut-off values in different populations.

17.
Dent Mater ; 36(6): 724-732, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32359850

RESUMEN

OBJECTIVES: to evaluate the probability of survival and failure modes of lithium-disilicate, feldspathic-ceramic, and resin-nanoceramic anterior veneers cemented on dentin analog substrates after sliding-contact step-stress accelerated life testing (SSALT). METHODS: A virtual incisor tooth preparation was produced with a reduction of 1.5mm at the incisal edge and of 0.7mm buccally. A .STL file of the preparation was generated and CAD/CAM based G10 dentin-analog material was used for testing. Laminate veneers were milled in three different materials: lithium-disilicate (LDS, E.max CAD), resin-nanoceramic (RN, Lava Ultimate), and feldspathic-ceramic (FELDS, Vita Blocks). SSALT was employed where a spherical indenter contacted the veneer, slided along its interface with G10 to lift off and start a new cycle at 2Hz in water. Qualitative fractography was performed. The probability of survival (90% confidence-bounds) was calculated for several load/cycle missions. RESULTS: The probability of survival for a mission of 50,000 cycles decreased from 50 up to 150N equally for all groups and were not different between them. At 200N, the probability of survival was significantly lower for FELDS (10%) compared to RN veneers (41%), whereas LDS presented intermediate values (22%). The characteristic strength of RN (247N) was significantly higher than LDS (149N), and FELDS (151N). In FELDS and LDS, hackles, wake hackles and twist hackles indicated the direction of crack propagation. In RN, hackles were observed. CONCLUSIONS: Differences in probability of survival were observed only at 180 and 200N between groups. Failure modes were similar with veneer fracture down to the tooth-analog substrate.


Asunto(s)
Diseño Asistido por Computadora , Porcelana Dental , Cerámica , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Coronas con Frente Estético , Ensayo de Materiales , Reproducibilidad de los Resultados
18.
Cardiovasc Diabetol ; 8: 28, 2009 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-19490620

RESUMEN

BACKGROUND: Type 2 diabetes mellitus (T2DM) is a genetically heterogeneous disease, hepatocyte nuclear factor-1 homeobox A (HNF1A) single-nucleotide polymorphisms (SNPs) playing a minor role in its pathogenesis. HNF1A is a frequent cause of monogenic diabetes, albeit with early-onset. Some uncommon subgroups like late-onset autosomal dominant diabetes mellitus (LOADDM) may present peculiar inheritance patterns with a stronger familial component. This study aims to investigate the relationship of HNF1A SNPs with cardiovascular risk factors in this group, as well as to characterize them in contrast with classical T2DM (CT2DM). METHODS: eighteen LOADDM (age at onset > 40 y.o.; diabetes in 3 contiguous generations, uniparental lineage) along with 48 CT2DM patients and 42 normoglycemic controls (N group) have been evaluated for cardiovascular risk factors and SNPs of HNF1A. RESULTS: LOADDM showed significantly higher frequencies of SNPs A98V (22.2% vs 2.1%, p = 0.02) and S487N (72.2% vs 43.8%, p = 0.049) of HNF1A compared to CT2DM. I27L did not show significant difference (66.7% vs 45.8%), but associated with lower risk of hypertriglyceridemia (OR 0.16, 95% CI 0.04-0.65, p = 0.01). "Protective effect" was independent from other well-known predictive risk factors for hypertriglyceridemia, such as waist circumference (OR 1.09 per 1 cm increase, p = 0.01) and HDL (OR 0.01 per 1 mmol/l, p = 0.005), after logistic regression. CONCLUSION: Late onset autosomal dominant diabetes mellitus is clinically indistinguishable from classical type 2 diabetes individuals. However, LOADDM group is enriched for common HNF1A polymorphisms A98V and S487N. I27L showed "protective effect" upon hypertriglyceridemia in this sample of individuals, suggesting a role for HNF1A on diabetic individuals' lipid profile. These data contribute to the understanding of the complex interactions between genes, hyperglycemia and cardiovascular risk factors development in type 2 diabetes mellitus.


Asunto(s)
Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/genética , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/genética , Factor Nuclear 1-alfa del Hepatocito/genética , Polimorfismo de Nucleótido Simple , Adulto , Edad de Inicio , Anciano , Estudios de Casos y Controles , Estudios Transversales , Diabetes Mellitus Tipo 2/clasificación , Femenino , Frecuencia de los Genes , Genes Dominantes , Humanos , Hipertrigliceridemia/etiología , Hipertrigliceridemia/genética , Modelos Logísticos , Masculino , Persona de Mediana Edad , Modelos Genéticos , Factores de Riesgo
19.
J Prosthet Dent ; 102(5): 306-12, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19853172

RESUMEN

STATEMENT OF PROBLEM: Several self-adhesive luting agents have recently been introduced on the market. It is crucial to know the effectiveness of such luting agents prior to their clinical application. PURPOSE: The purpose of this study was to evaluate the microtensile bond strengths (microTBS) produced by different self-adhesive cements and compare them with conventional luting agents. MATERIAL AND METHODS: Six self-adhesive cements (RelyX Unicem (UN), RelyX U100 (UC), SmartCem 2 (SC), G-Cem (GC), Maxcem (MC), and SeT (SET), and 2 conventional luting agents, one that uses a 2-step etch-and-rinse adhesive (RelyX ARC (RX)), and one that uses a 1-step self-etching adhesive (Panavia F (PF)), were used in this study. An additional group included the use of a 2-step self-etching primer adhesive system (Clearfil SE Bond) prior to the application of Panavia F (PS). Fifty-four human molars were abraded to expose occlusal surfaces and were assigned to 9 groups according to the luting material (n=6). Five composite resin (Filtek Z250) discs (12 mm in diameter, 5 mm thick) were cemented on the teeth according to manufacturers' instructions. After 24 hours of water storage, restored teeth were serially sectioned into beams with a cross-sectional area of approximately 1 mm2 at the bonded interface and were tested in tension with a crosshead speed of 1 mm/min. Failure mode was determined using scanning electron microscopy. Data were statistically analyzed by 1-way ANOVA and Tukey's studentized range HSD test (alpha =.05). RESULTS: Mean bond strengths (SD) in MPa were: RX, 69.6 (16.6)A; PS, 49.2 (9.7)A; PF, 33.7 (13.9)AB; GC, 16.9 (10.3)BC; UC, 15.3 (3.4)BC; UN, 12.5 (2.4)C; MC 11.5 (6.8)CD; SC, 8.5 (4.9)CD; SET, 4.6 (0.5)D. Groups with different uppercase letters were significantly different from each other (P<.05). The predominant failure mode of the self-adhesive cements was adhesive between the resin cement and dentin. CONCLUSIONS: The bond strengths produced by the multistep luting agents were significantly higher than those observed for most self-adhesive cements.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales/química , Bisfenol A Glicidil Metacrilato/química , Cementación/métodos , Resinas Compuestas/química , Esmalte Dental/ultraestructura , Grabado Dental , Análisis del Estrés Dental/instrumentación , Humanos , Ensayo de Materiales , Metacrilatos/química , Microscopía Electrónica de Rastreo , Diente Molar/ultraestructura , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Cementos de Resina/química , Estrés Mecánico , Resistencia a la Tracción , Factores de Tiempo , Agua/química
20.
Arch Endocrinol Metab ; 63(3): 250-257, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31066763

RESUMEN

OBJECTIVE: To verify the presence of variants in HNF1B in a sample of the Brazilian population selected according to the presence of renal cysts associated with hyperglycemia. SUBJECTS AND METHODS: We evaluated 28 unrelated patients with clinical suspicion of HNF1B mutation because of the concomitant presence of diabetes mellitus (DM) or prediabetes and renal cysts. Genotyping was accomplished using Sanger sequencing or multiplex ligation-dependent probe amplification (MLPA). In positive cases, available relatives were recruited. RESULTS: We found two patients with HNF1B mutations. The first presented the variant p.Pro328Leufs*48(c.983delC) and had DM, renal cysts, and hypomagnesemia. The second presented a heterozygous whole gene deletion in HNF1B, DM, renal cysts, body and tail pancreatic agenesis, and hypomagnesemia; this alteration was also found in his two siblings and his father. CONCLUSION: The recruitment of suspected cases of HNF1B gene mutations in Brazilians due to hyperglycemia and renal cysts presents two positive cases. Our cases contribute to the annotation of clinical and biochemical phenotypes of this rare form of maturity-onset diabetes of the young (MODY).


Asunto(s)
Nefropatías Diabéticas/genética , Factor Nuclear 1-beta del Hepatocito/genética , Hiperglucemia/genética , Enfermedades Renales Quísticas/genética , Mutación , Adulto , Brasil , Estudios de Cohortes , Nefropatías Diabéticas/complicaciones , Eliminación de Gen , Humanos , Hiperglucemia/complicaciones , Enfermedades Renales Quísticas/complicaciones , Persona de Mediana Edad , Fenotipo , Polimorfismo Genético/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA