Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36958391

RESUMEN

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Izquierda , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
2.
Catheter Cardiovasc Interv ; 99(5): 1647-1658, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35019204

RESUMEN

OBJECTIVES: To assess the impact of pulmonary hypertension (PH) on outcomes of patients with severe mitral annular calcification (MAC) undergoing transcatheter mitral valve replacement (TMVR). BACKGROUND: PH is associated with poor outcomes after mitral valve surgery. Whether the presence of PH in patients with MAC undergoing (TMVR) is associated with poor outcomes, is unknown. METHODS: Retrospective evaluation of 116 patients from 51 centers in 11 countries who underwent TMVR with valve in mitral annular calcification (ViMAC) using balloon-expandable aortic transcatheter valves (THVs) from September 2012 to March 2017. Pulmonary artery systolic blood pressure (PASP) by echocardiogram was available in 90 patients. The subjects were stratified based on PASP: No PH = PASP ≤35 mmHg (n = 11); mild to moderate PH = PASP 36-49 mmHg (n = 21) and severe PH = PASP ≥50 mmHg (n = 58). Clinical, procedural, and echocardiographic outcomes were assessed. RESULTS: Mean age was 72.7 (±12.8) years, 59 (65.6%) were female, Society of Thoracic Surgeons score was 15.8 + 11.8% and 90.0% where in New York Heart Association (NYHA) class III-IV. There was no significant difference in all-cause mortality at 30 days (no PH = 27.3%, mild-moderate PH = 19.0%, severe PH = 31.6%; p = 0.55) or at 1 year (no PH = 54.5%, mild-moderate PH = 38.1%, severe PH = 56.1%; p = 0.36). No difference in adverse events, NYHA class or amount of residual mitral regurgitation at 1 year were observed between the groups. CONCLUSION: This study suggests that the presence of PH in patients with predominantly mitral stenosis with MAC undergoing TMVR does not impact mortality or adverse events. Further studies are needed to fully understand the effect of PH in this group of patients.


Asunto(s)
Calcinosis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Hipertensión Pulmonar , Insuficiencia de la Válvula Mitral , Anciano , Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Cateterismo Cardíaco/efectos adversos , Femenino , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/cirugía , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 99(4): 1268-1276, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35084803

RESUMEN

OBJECTIVES: The purpose of this study was to characterize the anatomic relationship between the inferior vena cava (IVC) and tricuspid annulus (TA) and its potential impact on the performance of transcatheter TV interventions. BACKGROUND: Transcatheter tricuspid valve (TV) interventions are emerging as a therapeutic alternative for the treatment of severe, symptomatic tricuspid regurgitation (TR). Progression of TR is associated with right heart dilatation. These anatomic changes may distort the IVC-TA relationship and impact successful implantation of transcatheter devices. METHODS: Fifty patients who presented with symptomatic TR for consideration of transcatheter TV therapy with an available CT were included in the study. Comprehensive transesophageal echocardiogram and CT analyses were performed to assess the right-sided cardiac chambers, TA and IVC-TA relationship. RESULTS: The mean age of the study cohort was 78.4 ± 8.9 years. Torrential TR was present in 54% (n = 27). There was considerable variation in the short axis mid-IVC to mid-TA offset (SAXMID 18.2 ± 7.9 mm, range 4.7-42.1 mm). CONCLUSIONS: The IVC-to-TA relationship exhibits significant variability in patients with symptomatic TR. CT analysis of the tricuspid anatomy, including the relationship to the surrounding structures and the IVC, is essential for planning transcatheter TV interventions. Further studies are needed to define whether the IVC-to-TA relationship is a predictor of technical success in the context of specific transcatheter delivery systems.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Vena Cava Inferior/diagnóstico por imagen
4.
J Cardiothorac Vasc Anesth ; 36(5): 1279-1287, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34600832

RESUMEN

OBJECTIVES: Three-dimensional transesophageal echocardiography (TEE) is widely used to guide decision-making for mitral repair. The relative impact of surgical mitral valve repair (MVr) and MitraClip on annular remodeling is unknown. The aim was to determine the impact of both mitral repair strategies on annular geometry, including the primary outcome of annular circumference and area. DESIGN: This was a retrospective observational study of patients who underwent mitral intervention between 2016 and 2020. SETTING: Weill Cornell Medicine, a single, large, academic medical center. PARTICIPANTS: The population comprised 50 patients with degenerative mitral regurgitation (MR) undergoing MVr. INTERVENTIONS: Elective MVr and TEE. MEASUREMENTS AND MAIN RESULTS: Patients undergoing MitraClip or surgical MVr were matched (1:1) for sex and coronary artery disease. Mitral annular geometry indices were quantified on intraprocedural three-dimensional TEE. Mild or less MR on follow-up transthoracic echocardiography defined optimal response. Patients undergoing MitraClip were older (80 ± eight v 66 ± six years; p < 0.001) but were otherwise similar to surgical patients. Patients undergoing MitraClip had larger baseline left atrial and ventricular sizes, increased tenting height, and volume (p < 0.01), with a trend toward increased annular area (p = 0.23). MitraClip and surgery both induced immediate mitral annular remodeling, including decreased area, circumference, and tenting height (p < 0.001), with greater remodeling with surgical repair. At follow-up (4.1 ± 9.0 months) optimal response (≤ mild MR) was ∼twofold more common with surgery than MitraClip (81% v 46%; p = 0.02). The relative reduction in annular circumference (odds ratio [OR] 1.05 [1.00-1.09] per cm; p = 0.04) and area (OR 1.03 [1.00-1.05] per cm2; p = 0.049) were both associated with optimal response. CONCLUSIONS: Surgical MVr and MitraClip both reduce annular size, but repair-induced remodeling is greater with surgery and associated with an increased likelihood of optimal response.


Asunto(s)
Ecocardiografía Tridimensional , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
5.
J Card Surg ; 37(9): 2888-2890, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35726670

RESUMEN

An asymptomatic 63-year-old male with chronic type B aortic dissection underwent repair of an expanding 6.1 cm extent I thoracoabdominal aortic aneurysm. His postoperative course was complicated by respiratory failure from severe acute mitral regurgitation likely due to papillary muscle rupture, which was corrected with transcatheter MitraClip edge-to-edge repair.


Asunto(s)
Aneurisma de la Aorta Torácica , Rotura Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/cirugía , Rotura Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 97(3): E402-E410, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32588956

RESUMEN

OBJECTIVES: To describe the outcomes of urgent/emergent transcatheter edge-to-edge mitral valve repair (TMVr) and compare the clinical, echocardiographic, and procedural characteristics of survivors and nonsurvivors. BACKGROUND: TMVr is a treatment strategy for select patients with severe primary or secondary mitral regurgitation. However, knowledge regarding outcomes for urgent/emergent TMVr is limited. METHODS: All urgent or emergent TMVr procedures using MitraClip performed at the University of Washington Medical Center between January 2018 and March 2019 were identified and clinical, echocardiographic, hemodynamic, procedural, and outcomes data were obtained by chart review. Outcomes included all-cause mortality, hospital mortality, procedural success, periprocedural complications, and hospital readmission. RESULTS: Of the 20 patients who underwent urgent/emergent TMVr, eight were treated for cardiogenic shock (CS), four for acute decompensated heart failure (ADHF) with hypoxemic respiratory failure requiring mechanical ventilation, and eight for ADHF with failure of inpatient medical therapy. Mechanical circulatory support (MCS) was used in six patients; preceding TMVr in three patients and immediately post-TMVr in three patients. Overall, 30-day mortality and hospital readmission rates were 21 and 13%, respectively. Over a median 153 days (IQR 20-491) of follow-up, 10 patients (50%) died. Preprocedure CS, new or ongoing MCS post-TMVr, refractory respiratory failure post-TMVr, and acute kidney injury post-TMVr were associated with mortality. CONCLUSIONS: In a single-center retrospective analysis, urgent/emergent TMVr in high-risk patients with ADHF or CS was associated with high short-term mortality and periprocedural complications. Prospective studies are warranted to inform patient selection and periprocedural management for urgent/emergent TMVr.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 98(4): E626-E636, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33847434

RESUMEN

OBJECTIVES: We present our initial experience with the fourth-generation MitraClip™ (G4) system and propose preliminary criteria for device selection. BACKGROUND: The MitraClip™ G4 system recently underwent a "controlled release" for transcatheter edge-to-edge mitral valve repair. The four new devices include technical improvements such as controlled gripper actuation (independent leaflet capture) and continuous left atrial pressure monitoring. To date, a patient-specific device selection algorithm, and the technology's impact on procedural times and success, have not been described. METHODS: We present an initial multi-center experience and short-term outcomes with the new system, suggest procedural and imaging considerations, and propose initial guidance for device selection. RESULTS: Sixty-one procedures performed by three operators at two centers between November 2019 and May 2020 were analyzed. At 30-day follow-up, there were three deaths (4.9%), four neurological events (6.6%), and seven re-hospitalizations (11.5%). Fifty-nine patients achieved device and procedural success (96.7%), and there was one device-related technical issue (1.6%). Compared to the same operators utilizing the third generation MitraClip™, the G4 system resulted in a significant reduction in the median number of clips used per patient (1 IQR 1-2 vs. 2 IQR 1-3, p = .023) and a trend toward shorter device times. CONCLUSION: Based on our initial experience, we found that the MitraClip™ G4 system is associated with high procedural success and fewer devices needed per procedure. The expanded device options may allow a more targeted approach to the myriad of pathologic presentations of mitral regurgitation. This early experience should provide a foundational opportunity for further refinement.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 97(4): E580-E587, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32894804

RESUMEN

OBJECTIVES: We sought to document aortic cusps fluoroscopic projections and their distributions using leaflet alignment which is a novel concept to optimize visualization of leaflets and for guiding BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent coronary artery obstruction) and determine whether these projections were feasible in catheter laboratory. BACKGROUND: Optimal fluoroscopic projections of aortic valve cusps have not been well described. METHODS: A total of 128 pre-transcatheter aortic valve replacement (pre-TAVR) computed tomographies (CT) (72 native valves and 56 bioprosthetic surgical valves) were analyzed. Using CT software (3Mensio, Pie medical imaging, the Netherlands), leaflet alignment was performed and the feasibility of these angles, which were defined as rate of obtainable with efforts (within LAO/RAO of 85° and CRA/CAU of 50°) were evaluated. RESULTS: High feasibility was seen in right coronary cusp (RCC) front view (100%) and left coronary cusp (LCC) side view (99.2%), followed by noncoronary cusp side view (95.3%). In contrast, low feasibility of RCC side view (7.8%) and LCC front view (47.6%) was observed. No statistical differences were seen between the distribution of native valves and bioprosthetic surgical valves. With patient/table tilt of 20°LAO and 10°CRA, the feasibility of RCC side view and LCC front view increased to 43.7 and 85.2%, respectively. CONCLUSION: Distributions of each cusp's leaflet alignment follows "sigmoid curve" which can provide better understanding of aortic valve cusp orientation in TAVR and BASILICA. RCC side view used in right cusp BASILICA is commonly unachievable in catheter laboratory and may improve with patient/table tilt.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
JAMA ; 326(22): 2277-2286, 2021 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-34905030

RESUMEN

Importance: Patent foramen ovale (PFO)-associated strokes comprise approximately 10% of ischemic strokes in adults aged 18 to 60 years. While device closure decreases stroke recurrence risk overall, the best treatment for any individual is often unclear. Objective: To evaluate heterogeneity of treatment effect of PFO closure on stroke recurrence based on previously developed scoring systems. Design, Setting, and Participants: Investigators for the Systematic, Collaborative, PFO Closure Evaluation (SCOPE) Consortium pooled individual patient data from all 6 randomized clinical trials that compared PFO closure plus medical therapy vs medical therapy alone in patients with PFO-associated stroke, and included a total of 3740 participants. The trials were conducted worldwide from 2000 to 2017. Exposures: PFO closure plus medical therapy vs medical therapy alone. Subgroup analyses used the Risk of Paradoxical Embolism (RoPE) Score (a 10-point scoring system in which higher scores reflect younger age and the absence of vascular risk factors) and the PFO-Associated Stroke Causal Likelihood (PASCAL) Classification System, which combines the RoPE Score with high-risk PFO features (either an atrial septal aneurysm or a large-sized shunt) to classify patients into 3 categories of causal relatedness: unlikely, possible, and probable. Main Outcomes and Measures: Ischemic stroke. Results: Over a median follow-up of 57 months (IQR, 24-64), 121 outcomes occurred in 3740 patients. The annualized incidence of stroke with medical therapy was 1.09% (95% CI, 0.88%-1.36%) and with device closure was 0.47% (95% CI, 0.35%-0.65%) (adjusted hazard ratio [HR], 0.41 [95% CI, 0.28-0.60]). The subgroup analyses showed statistically significant interaction effects. Patients with low vs high RoPE Score had HRs of 0.61 (95% CI, 0.37-1.00) and 0.21 (95% CI, 0.11-0.42), respectively (P for interaction = .02). Patients classified as unlikely, possible, and probable using the PASCAL Classification System had HRs of 1.14 (95% CI, 0.53-2.46), 0.38 (95% CI, 0.22-0.65), and 0.10 (95% CI, 0.03-0.35), respectively (P for interaction = .003). The 2-year absolute risk reduction was -0.7% (95% CI, -4.0% to 2.6%), 2.1% (95% CI, 0.6%-3.6%), and 2.1% (95% CI, 0.9%-3.4%) in the unlikely, possible, and probable PASCAL categories, respectively. Device-associated adverse events were generally higher among patients classified as unlikely; the absolute risk increases in atrial fibrillation beyond day 45 after randomization with a device were 4.41% (95% CI, 1.02% to 7.80%), 1.53% (95% CI, 0.33% to 2.72%), and 0.65% (95% CI, -0.41% to 1.71%) in the unlikely, possible, and probable PASCAL categories, respectively. Conclusions and Relevance: Among patients aged 18 to 60 years with PFO-associated stroke, risk reduction for recurrent stroke with device closure varied across groups classified by their probabilities that the stroke was causally related to the PFO. Application of this classification system has the potential to guide individualized decision-making.


Asunto(s)
Anticoagulantes/uso terapéutico , Foramen Oval Permeable/cirugía , Accidente Cerebrovascular/tratamiento farmacológico , Adolescente , Adulto , Femenino , Fibrinolíticos/uso terapéutico , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Números Necesarios a Tratar , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Factores de Riesgo , Prevención Secundaria , Dispositivo Oclusor Septal , Accidente Cerebrovascular/etiología , Adulto Joven
10.
Stroke ; 51(10): 3119-3123, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32921262

RESUMEN

BACKGROUND AND PURPOSE: In patients with cryptogenic stroke and patent foramen ovale (PFO), the Risk of Paradoxical Embolism (RoPE) Score has been proposed as a method to estimate a patient-specific "PFO-attributable fraction"-the probability that a documented PFO is causally-related to the stroke, rather than an incidental finding. The objective of this research is to examine the relationship between this RoPE-estimated PFO-attributable fraction and the effect of closure in 3 randomized trials. METHODS: We pooled data from the CLOSURE-I (Evaluation of the STARFlex Septal Closure System in Patients With a Stroke and/or Transient Ischemic Attack due to Presumed Paradoxical Embolism through a Patent Foramen Ovale), RESPECT (Randomized Evaluation of Recurrent Stroke Comparing PFO Closure to Established Current Standard of Care Treatment), and PC (Clinical Trial Comparing Percutaneous Closure of Patent Foramen Ovale [PFO] Using the Amplatzer PFO Occluder With Medical Treatment in Patients With Cryptogenic Embolism) trials. We examine the treatment effect of closure in high RoPE score (≥7) versus low RoPE score (<7) patients. We also estimated the relative risk reduction associated with PFO closure across each level of the RoPE score using Cox proportional hazard analysis. We estimated a patient-specific attributable fraction using a PC trial-compatible (9-point) RoPE equation (omitting the neuroradiology variable), as well as a 2-trial analysis using the original (10-point) RoPE equation. We examined the Pearson correlation between the estimated attributable fraction and the relative risk reduction across RoPE strata. RESULTS: In the low RoPE score group (<7, n=912), the rate of recurrent strokes per 100 person-years was 1.37 in the device arm versus 1.68 in the medical arm (hazard ratio, 0.82 [0.42-1.59] P=0.56) compared with 0.30 versus 1.03 (hazard ratio, 0.31 [0.11-0.85] P=0.02) in the high RoPE score group (≥7, n=1221); treatment-by-RoPE score group interaction, P=0.12. The RoPE score estimated attributable fraction anticipated the relative risk reduction across all levels of the RoPE score, in both the 3-trial (r=0.95, P<0.001) and 2-trial (r=0.92, P<0.001) analyses. CONCLUSIONS: The RoPE score estimated attributable fraction is highly correlated to the relative risk reduction of device versus medical therapy. This observation suggests the RoPE score identifies patients with cryptogenic stroke who are likely to have a PFO that is pathogenic rather than incidental.


Asunto(s)
Embolia Paradójica/etiología , Foramen Oval Permeable/complicaciones , Accidente Cerebrovascular/complicaciones , Cateterismo Cardíaco , Foramen Oval Permeable/cirugía , Humanos , Factores de Riesgo , Prevención Secundaria , Resultado del Tratamiento
11.
Curr Cardiol Rep ; 22(4): 23, 2020 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-32067112

RESUMEN

PURPOSE OF REVIEW: A combination of evolving 3D printing technologies, new 3D printable materials, and multi-disciplinary collaborations have made 3D printing applications for transcatheter aortic valve replacement (TAVR) a promising tool to promote innovation, increase procedural success, and provide a compelling educational tool. This review synthesizes the knowledge via publications and our group's experience in this area that exemplify uses of 3D printing for TAVR. RECENT FINDINGS: Patient-specific 3D-printed models have been used for TAVR pre-procedural device sizing, benchtop prediction of procedural complications, planning for valve-in-valve and bicuspid aortic valve procedures, and more. Recent publications also demonstrate how 3D printing can be used to test assumptions about why certain complications occur during THV implantation. Finally, new materials and combinations of existing materials are starting to bridge the large divide between current 3D material and cardiac tissue properties. Several studies have demonstrated the utility of 3D printing in understanding challenges of TAVR. Innovative approaches to benchtop testing and multi-material printing have brought us closer to being able to predict how a THV will interact with a specific patient's aortic anatomy. This work to date is likely to open the door for advancements in other areas of structural heart disease, such as interventions involving the mitral valve, tricuspid valve, and left atrial appendage.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Impresión Tridimensional , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
12.
Circulation ; 137(4): 388-399, 2018 01 23.
Artículo en Inglés | MEDLINE | ID: mdl-29358344

RESUMEN

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.


Asunto(s)
Bioprótesis/clasificación , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas/clasificación , Válvulas Cardíacas/cirugía , Falla de Prótesis , Terminología como Asunto , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Remoción de Dispositivos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvulas Cardíacas/diagnóstico por imagen , Válvulas Cardíacas/fisiopatología , Humanos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
J Interv Cardiol ; 2019: 7598581, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31777471

RESUMEN

OBJECTIVE: To identify outcomes of patients undergoing emergency transcatheter aortic valve replacement (TAVR) and determine predictors of in-hospital mortality. BACKGROUND: Emergency TAVR has emerged as a viable treatment strategy for patients with decompensated severe aortic stenosis and/or regurgitation; however, data on patients undergoing emergency TAVR are limited. METHODS: All emergency TAVR procedures were identified from a single tertiary academic center between January 2015 and August 2018. RESULTS: 31 patients underwent emergency TAVR due to cardiogenic shock (26 patients), electrical instability with incessant ventricular tachycardia (2 patients), severe refractory angina (2 patients), and decompensated heart failure with hypoxemic respiratory failure requiring mechanical ventilation (1 patient). Mechanical circulatory support (MCS) was used in 16 (51.6%). MCS initiation occurred immediately prior to TAVR in 10 patients and placed post-TAVR in 6 patients. 6 patients died before hospital discharge (in-hospital mortality 19.4%). 1-year and 2-year survival rates were 61.0% and 55.9%, respectively. Univariate predictors of in-hospital mortality were preprocedural pulmonary artery pulsatility index (PAPi) ≤1.8 (66.7% vs. 20.0%, p=0.01), intraprocedural cardiopulmonary resuscitation (CPR) (83.3% vs 4.0%, p ≤ 0.001), acute kidney injury post-TAVR (80.0% vs. 4.2%, p ≤ 0.001), initiation of dialysis post-TAVR (60.0% vs. 4.2%, p ≤ 0.001), and MCS initiation post-TAVR (50.0% vs. 12.0%, p=0.03). MCS initiation before TAVR was associated with improved survival compared with post-TAVR initiation. CONCLUSION: Emergency TAVR in extreme risk patients with acute decompensated heart failure or cardiogenic shock secondary to severe aortic valve disease is associated with high in-hospital mortality rates. Careful patient selection taking into account right heart function, assessed by PAPi, and early utilization of MCS may improve survival following emergency TAVR.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Urgencias Médicas , Mortalidad Hospitalaria , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Lesión Renal Aguda/mortalidad , Anciano , Angina Inestable/cirugía , Reanimación Cardiopulmonar , Oxigenación por Membrana Extracorpórea , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Periodo Intraoperatorio , Masculino , Flujo Pulsátil , Diálisis Renal/mortalidad , Insuficiencia Respiratoria/cirugía , Choque Cardiogénico/cirugía , Taquicardia Ventricular/cirugía , Washingtón/epidemiología
15.
Eur Heart J ; 36(26): 1651-9, 2015 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-25870204

RESUMEN

Transcatheter mitral interventions has been developed to address an unmet clinical need and may be an alternative therapeutic option to surgery with the intent to provide symptomatic and prognostic benefit. Beyond MitraClip therapy, alternative repair technologies are being developed to expand the transcatheter intervention armamentarium. Recently, the feasibility of transcatheter mitral valve implantation in native non-calcified valves has been reported in very high-risk patients. Acknowledging the lack of scientific evidence to date, it is difficult to predict what the ultimate future role of transcatheter mitral valve interventions will be. The purpose of the present report is to review the current state-of-the-art of mitral valve intervention, and to identify the potential future scenarios, which might benefit most from the transcatheter repair and replacement devices under development.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/cirugía , Anticoagulantes/uso terapéutico , Bioprótesis , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/tendencias , Ecocardiografía , Diseño de Equipo , Fluoroscopía , Predicción , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Válvula Mitral/fisiología , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/tendencias , Insuficiencia de la Válvula Mitral/fisiopatología , Función Ventricular Izquierda/fisiología
16.
N Engl J Med ; 366(11): 991-9, 2012 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-22417252

RESUMEN

BACKGROUND: The prevalence of patent foramen ovale among patients with cryptogenic stroke is higher than that in the general population. Closure with a percutaneous device is often recommended in such patients, but it is not known whether this intervention reduces the risk of recurrent stroke. METHODS: We conducted a multicenter, randomized, open-label trial of closure with a percutaneous device, as compared with medical therapy alone, in patients between 18 and 60 years of age who presented with a cryptogenic stroke or transient ischemic attack (TIA) and had a patent foramen ovale. The primary end point was a composite of stroke or transient ischemic attack during 2 years of follow-up, death from any cause during the first 30 days, or death from neurologic causes between 31 days and 2 years. RESULTS: A total of 909 patients were enrolled in the trial. The cumulative incidence (Kaplan-Meier estimate) of the primary end point was 5.5% in the closure group (447 patients) as compared with 6.8% in the medical-therapy group (462 patients) (adjusted hazard ratio, 0.78; 95% confidence interval, 0.45 to 1.35; P=0.37). The respective rates were 2.9% and 3.1% for stroke (P=0.79) and 3.1% and 4.1% for TIA (P=0.44). No deaths occurred by 30 days in either group, and there were no deaths from neurologic causes during the 2-year follow-up period. A cause other than paradoxical embolism was usually apparent in patients with recurrent neurologic events. CONCLUSIONS: In patients with cryptogenic stroke or TIA who had a patent foramen ovale, closure with a device did not offer a greater benefit than medical therapy alone for the prevention of recurrent stroke or TIA. (Funded by NMT Medical; ClinicalTrials.gov number, NCT00201461.).


Asunto(s)
Embolia Paradójica/prevención & control , Foramen Oval Permeable/tratamiento farmacológico , Foramen Oval Permeable/cirugía , Ataque Isquémico Transitorio/prevención & control , Inhibidores de Agregación Plaquetaria/uso terapéutico , Accidente Cerebrovascular/prevención & control , Adolescente , Adulto , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Aspirina/uso terapéutico , Clopidogrel , Terapia Combinada , Quimioterapia Combinada , Femenino , Foramen Oval Permeable/complicaciones , Humanos , Ataque Isquémico Transitorio/etiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/efectos adversos , Complicaciones Posoperatorias , Prótesis e Implantes , Prevención Secundaria , Accidente Cerebrovascular/etiología , Ticlopidina/análogos & derivados , Ticlopidina/uso terapéutico , Warfarina/efectos adversos , Warfarina/uso terapéutico , Adulto Joven
17.
Catheter Cardiovasc Interv ; 84(1): 129-36, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24323764

RESUMEN

BACKGROUND: The MitraClip® system is a newer percutaneous device that has shown promising results but data on its safety and efficacy in low- and high-surgical risk populations continues to evolve. We performed a systematic review of the published studies reporting the safety and efficacy of MitraClip® implantation for treatment of moderate to severe and severe mitral regurgitation (MR). METHODS: Reviewers independently searched for relevant articles in Medline and abstracted clinical information based on pre-defined criteria and end-points. Patients were classified as low- or high-surgical risk for conventional mitral valve (MV) surgery based on Society of Thoracic Surgeons score, EuroSCORE, or surgeon discretion. Primary safety outcome was 30-day mortality and primary efficacy outcomes were freedom from death, ≥3+ MR, and requirement for MV surgery during follow-up. RESULTS: Immediate and long-term outcomes of 16 studies, including 2980 patients (age 73.7 ± 0.6 years; 63.3% males) receiving the MitraClip®, were analyzed. Acute procedural success rate was 91.4% with a procedural mortality of 0.1%. Mortality at 30 days and long-term (310 days) follow-up was 4.2 and 15.8%, respectively and was significantly higher in the high-risk group (P = 0.003 and 0.019, respectively). Incidence of major procedural adverse outcomes was relatively low with blood transfusion accounting for most events. At follow-up, the number of patients with ≥3+ MR reduced from 96.3% to 14.7% (P < 0.001), and those with NYHA class III/IV reduced from 83.2% to 23.4% (P < 0.001). CONCLUSION: MitraClip® implantation for moderate to severe or severe MR appears to be safe with a very low procedural mortality. There is significant improvement in functional outcomes although long-term mortality is high, especially in high surgical risk patients.


Asunto(s)
Cateterismo Cardíaco/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico , Diseño de Prótesis , Índice de Severidad de la Enfermedad
18.
Pulm Circ ; 14(2): e12374, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38736894

RESUMEN

Chronic thromboembolic pulmonary hypertension (CTEPH) is a sequela of a pulmonary embolus that occurs in approximately 1%-3% of patients. Pulmonary thromboendoarterectomy (PTE) can be a curative procedure, but balloon pulmonary angioplasty (BPA) has emerged as an option for poor surgical candidates. We used the National Inpatient Sample to query patients who underwent PTE or BPA between 2012 and 2019 with CTEPH. The primary outcome was a composite of in-hospital mortality, myocardial infarction, stroke, tracheostomy, and prolonged mechanical ventilation. Outcomes were compared between low- and high-volume centers, defined as 5 and 10 procedures per year for BPA and PTE, respectively. During our study period, 870 BPA and 2395 PTE were performed. There was a 328% relative increase in the number of PTE performed during the study period. Adverse events for BPA were rare. There was an increase in the primary composite outcome for low-volume centers compared to high-volume centers for PTE (24.4% vs. 12.1%, p = 0.003). Patients with hospitalizations for PTE in low-volume centers were more likely to have prolonged mechanical ventilation (20.0%% vs. 7.2%, p < 0.001) and tracheostomy (7.8% vs. 2.6%, p = 0.017). In summary, PTE rates have been rising over the past 10 years, while BPA rates have remained stable. While adverse outcomes are rare for BPA, patients with hospitalizations at low-volume centers for PTE were more likely to have adverse outcomes. For patients undergoing treatment of CTEPH with BPA or PTE, referral to high-volume centers with multidisciplinary teams should be encouraged for optimal outcomes.

19.
Am J Cardiol ; 213: 99-105, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38110022

RESUMEN

The association, if any, between the effective regurgitant orifice area (EROA) to left ventricular end-diastolic volume (LVEDV) ratio and 1-year mortality is controversial in patients who undergo mitral transcatheter edge-to-edge repair (m-TEER) with the MitraClip system (Abbott Vascular, Santa Clara, CA). This study's objective was to determine the association between EROA/LVEDV and 1-year mortality in patients who undergo m-TEER with MitraClip. In patients with severe secondary (functional) mitral regurgitation (MR), we analyzed registry data from 11 centers using generalized linear models with the generalized estimating equations approach. We studied 525 patients with secondary MR who underwent m-TEER. Most patients were male (63%) and were New York Heart Association class III (61%) or IV (21%). Mitral regurgitation was caused by ischemic cardiomyopathy in 51% of patients. EROA/LVEDV values varied widely, with median = 0.19 mm2/ml, interquartile range [0.12,0.28] mm2/ml, and 187 patients (36%) had values <0.15 mm2/ml. Postprocedural mitral regurgitation severity was substantially alleviated, being 1+ or less in 74%, 2+ in 20%, 3+ in 4%, and 4+ in 2%; 1-year mortality was 22%. After adjustment for confounders, the logarithmic transformation (Ln) of EROA/LVEDV was associated with 1-year mortality (odds ratio 0.600, 95% confidence interval 0.386 to 0.933, p = 0.023). A higher Society of Thoracic Surgeons risk score was also associated with increased mortality. In conclusion, lower values of Ln(EROA/LVEDV) were associated with increased 1-year mortality in this multicenter registry. The slope of the association is steep at low values but gradually flattens as Ln(EROA/LVEDV) increases.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Femenino , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Resultado del Tratamiento , Sistema de Registros , América del Norte
20.
Neurology ; 102(10): e209388, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38701403

RESUMEN

BACKGROUND AND OBJECTIVES: Whether patent foramen ovale (PFO) closure benefits older patients with PFO and cryptogenic stroke is unknown because randomized controlled trials (RCTs) have predominantly enrolled patients younger than 60 years of age. Our objective was to estimate anticipated effects of PFO closure in older patients to predict the numbers needed to plan an RCT. METHODS: Effectiveness estimates are derived from major observational studies (Risk of Paradoxical Embolism [RoPE] Study and Oxford Vascular Study, together referred to as the "RoPE-Ox" database) and all 6 major RCTs (Systematic, Collaborative, PFO Closure Evaluation [SCOPE] Consortium). To estimate stroke recurrence risk, observed outcomes were calculated for patients older than 60 years in the age-inclusive observational databases (n = 549). To estimate the reduction in the rate of recurrent stroke associated with PFO closure vs medical therapy based on the RoPE score and the presence of high-risk PFO features, a Cox proportional hazards regression model was developed on the RCT data in the SCOPE database (n = 3,740). These estimates were used to calculate sample sizes required for a future RCT. RESULTS: Five-year risk of stroke recurrence using Kaplan-Meier estimates was 13.7 (95% CI 10.5-17.9) overall, 14.9% (95% CI 10.2-21.6) in those with high-risk PFO features. Predicted relative reduction in the event rate with PFO closure was 12.9% overall, 48.8% in those with a high-risk PFO feature. Using these estimates, enrolling all older patients with cryptogenic stroke and PFO would require much larger samples than those used for prior PFO closure trials, but selectively enrolling patients with high-risk PFO features would require totals of 630 patients for 90% power and 471 patients for 80% power, with an average of 5 years of follow-up. DISCUSSION: Based on our projections, anticipated effect sizes in older patients with high-risk features make a trial in these subjects feasible. With lengthening life expectancy in almost all regions of the world, the utility of PFO closure in older adults is increasingly important to explore.


Asunto(s)
Estudios de Factibilidad , Foramen Oval Permeable , Selección de Paciente , Accidente Cerebrovascular , Humanos , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/cirugía , Anciano , Accidente Cerebrovascular/etiología , Masculino , Femenino , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Resultado del Tratamiento , Factores de Edad , Anciano de 80 o más Años
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA