Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Immunobiology ; 227(3): 152216, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35436751

RESUMEN

INTRODUCTION: The immune response during and after SARS-CoV-2 infection can be complex and heterogeneous, and it can be affected by the severity of the disease. It can also contribute to an unfavorable evolution and bring about short and long term effects. The aim of this study was to characterize the lymphocyte composition according to the severity of COVID-19, as well as its degree of relationship to the specific humoral response to SARS-CoV-2 in convalescents up to 106 days after the infection and in their exposed relatives. METHODS: An applied research was carried out with a cross-section analytical design, from March 11 to June 11, 2020 in Cuba. The sample consisted of 251 convalescents from COVID-19 over 18 years of age and 88 exposed controls who did not become ill. The B and T cell subpopulations, including memory T cells, as well as the relationship with the humoral immune response against SARS-CoV-2, were identified by flow cytometry and enzyme immunoassay. RESULTS: Convalescent patients, who evolved with severe forms, showed a decrease in frequency and a greater proportion of individuals with values ​​lower than the minimum normal range of B cells, CD3 + CD4 + cells and the CD4 + / CD8 + ratio, as well as a higher frequency and a greater proportion of individuals with values ​​above the normal maximum range of CD3 + CD8 + and NK cells. Convalescent patients with severe forms of COVID-19 that exhibited IgG / RBD titers ≥ 1/200 had a lower frequency of TEMRA CD8 + cells (p = 0.0128) and TEMRA CD4 + (p = 0.0068). IgG / RBD titers were positively correlated with the relative frequency of CD4 + CM T memory cells (r = 0.4352, p = 0.0018). CONCLUSIONS: The identified alterations of B and T lymphocytes suggest that convalescent patients with the severe disease could be vulnerable to infectious, autoimmune or autotinflammatory processes; therefore, these individuals need medical follow-up after recovering from the acute disease. Furthermore, the role of T cells CD4 + CM in the production of antibodies against SARS-CoV-2 is confirmed, and it is noted that the defect of memory T cells CD8 + TEMRA could contribute to the development of severe forms of COVID-19.


Asunto(s)
COVID-19 , Adolescente , Adulto , Anticuerpos Antivirales , Linfocitos T CD8-positivos , Humanos , Inmunoglobulina G , SARS-CoV-2
2.
Rev. habanera cienc. méd ; 22(1)feb. 2023.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1560081

RESUMEN

Introducción: La detección del virus SARS-CoV-2, agente causal de la COVID-19, es determinante para disminuir la propagación de la actual pandemia. Si bien el procedimiento de elección es la determinación del ácido nucleico del virus mediante la reacción en cadena de la polimerasa, también es necesario disponer de pruebas rápidas, con alta sensibilidad y precisión. Objetivo: Analizar la validez diagnóstica de un ensayo rápido de antígeno SARS-CoV-2, utilizado para la detección de la COVID-19 en el policlínico "5 de Septiembre" del municipio Playa. Material y Métodos: Se realizó un estudio analítico de corte transversal con 590 pacientes atendidos en la consulta de infecciones respiratorias agudas, en el período de enero a agosto de 2021. La determinación de antígeno SARS-CoV-2 se realizó con un ensayo rápido y la confirmación se hizo mediante la reacción en cadena de la polimerasa. Resultados: La prueba rápida de antígeno tuvo una elevada sensibilidad (98,19 %) y especificidad (92,39 %). La concordancia de los resultados obtenidos entre ambas pruebas fue elevada (0,868). Las sintomatologías más frecuentes reportadas, fueron, cefalea (51,69 %), fiebre (39,15 %), tos (37,16 %), pérdida del gusto/olfato (34,06 %) y rinorrea (30,16 %). Conclusiones: El ensayo rápido de antígeno del SARS-CoV-2 usado para la detección de la COVID-19 demostró validez y puede ser utilizado para el diagnóstico de la enfermedad. Las sintomatologías cefalea, fiebre, tos, pérdida del gusto/olfato y rinorrea fueron las más frecuentes, reportadas en más de 30 de los casos.


Introduction: The detection of the SARS-CoV-2 virus, the causal agent of COVID-19, is decisive to reduce the spread of the current pandemic. Although the procedure of choice is the determination of the nucleic acid of the virus using the polymerase chain reaction, the availability of rapid, highly sensitive, and accurate tests is also necessary. Objective: To analyze the diagnostic validity of a SARS-CoV-2 antigen rapid diagnostic test for the detection of COVID-19 in the "5 de Septiembre" Polyclinic in Playa municipality. Material and Methods: A cross-sectional analytical study was carried out on 590 patients seen in the acute respiratory infections consulting room in the period from January to August 2021. The detection of the SARS-CoV-2 antigen was performed using a rapid test and it was confirmed by polymerase chain reaction. Results: The rapid antigen test had a high sensitivity (98.19%) and specificity (92.39%). The concordance of the results obtained from both tests was high (0.868). The most frequent reported symptoms were headache (51.69%), fever (39.15%), cough (37.16%), loss of taste/smell (34.06%), and runny nose (30.16%). Conclusions: The SARS-CoV-2 antigen rapid diagnostic test used for the detection of COVID-19 is valid and can be used in the diagnosis of the disease. Symptoms such as headache, fever, cough, loss of taste/smell, and runny nose were the most frequently reported in more than 30% of cases.

3.
Vaccimonitor (La Habana, Print) ; 30(1)ene.-abr. 2021. tab
Artículo en Español | CUMED, LILACS | ID: biblio-1150247

RESUMEN

La uveítis anterior no infecciosa es una enfermedad inflamatoria del ojo que afecta al tracto uveal y que puede causar ceguera total y otras discapacidades visuales. Esta enfermedad se ubica en el espectro de enfermedades autoinmunes y autoinflamatorias. Se han descrito respuestas no adecuadas a la vacunación en enfermedades mediadas por el sistema inmune, por lo que se evaluaron los niveles de antitoxina tetánica y diftérica en pacientes cubanos con uveítis anterior no infecciosa, relacionada con el alelo HLA-B27. Se determinaron los niveles de antitoxina tetánica y diftérica mediante ELISA en 190 pacientes con uveítis anterior no infecciosa y controles supuestamente sanos. El 97,37 por ciento de los pacientes con uveítis mostraron niveles de protección de antitoxina tetánica mayor o igual a 0,1 UI/mL, similar a lo observado en los controles sanos (98,95 por ciento) (p=0,4385). Las proporciones de pacientes con uveítis anterior no infecciosa y sus controles en los diferentes niveles de protección de antitoxina tetánica fueron similares (p>0,05), al igual que los títulos medios geométricos (p=0,2907). En los pacientes con uveítis, de 65 años o más, se detectó una mayor proporción de individuos con títulos protectores de larga duración (>1,0 UI/mL) de antitoxina diftérica (p=0,0065). En los pacientes con uveítis no se observó asociación entre la presencia del alelo HLA-B27 y la respuesta de anticuerpos frente al toxoide tetánico (p=0,6196) y diftérico (p=0,1917). El 37,9 por ciento de los pacientes con uveítis y el 42 por ciento de los controles, presentaron títulos no protectores (<0,1 UI/mL) de antitoxina diftérica (0,1148). La mayoría de los pacientes con uveítis anterior no infecciosa y los controles supuestamente sanos presentaron protección frente al toxoide tetánico; mientras que, en los pacientes con uveítis, así como en los controles supuestamente sanos, con edad igual o más de 18 años, se debe reevaluar incluir refuerzos con toxoide diftérico para alcanzar mayores niveles de protección frente a la difteria(AU)


Non-infectious anterior uveitis is an inflammatory disease of the eye that affects the uveal tract and can cause total blindness and other visual disabilities. Autoimmune and inflammatory diseases are associated with qualitative and quantitative alterations in the immune response; therefore, the levels of tetanus and diphtheria antitoxin related to the HLA-B27 allele were evaluated in Cuban patients with non-infectious anterior uveitis. Tetanus and diphtheria antitoxin levels were determined by ELISA in 190 patients with non-infectious anterior uveitis and healthy control individuals. 97.37 percent of patients with uveitis showed protective tetanus antitoxin levels greater than and equal to 0.1 IU/mL as well as healthy controls (98.95 percent) (p=0.4385). The proportions of patients with non-infectious anterior uveitis and presumably healthy controls in the different levels of protective tetanus antitoxin were similar (p>0.05) at all levels of protection, as were the geometric mean titers for this antitoxin (p=0.2907). Patients with uveitis aged 65 years or older had a higher proportion of individuals with long-term reliable protective titers (>1.0 IU/mL) of diphtheria antitoxin (p=0.0065). In uveitis patients, no association was observed between the presence of the HLA-B27 allele and the antibody response against tetanus toxoid (p=0.6196) and diphtheria (p=0.1917). Similarly, 37.9 percent of patients with uveitis and 42 percent of their controls had non-protective titers (<0.1 IU/mL) of diphtheria antitoxin (0.1148). Most patients with anterior uveitis and control subjects were protected against tetanus (p>0.05), while in patients with uveitis and supposedly healthy controls, aged 18 years or older, the administration of booster doses with diphtheria toxoid should be reevaluated to achieve higher levels of protection against diphtheria(AU)


Asunto(s)
Humanos , Masculino , Femenino , Antitoxina Diftérica , Antitoxina Tetánica , Antígeno HLA-B27 , Uveítis Anterior/diagnóstico , Vacunas , Cuba
4.
Rev. habanera cienc. méd ; 19(1): 48-62, ene.-feb. 2020. tab, graf
Artículo en Español | LILACS, CUMED | ID: biblio-1099145

RESUMEN

Introducción: La efectividad del programa nacional de inmunización ha impactado en la reducción de la incidencia del virus de la hepatitis B en Cuba; sin embargo, no es despreciable la cantidad de pacientes infectados crónicos, que por esta causa, se detectan en la práctica asistencial, aunque insuficientes los estudios epidemiológicos que los caracterizan. Objetivo: Describir las principales características clínicas, biomoleculares e inmunológicas de los pacientes con VHB crónica atendidos en el Instituto de Gastroenterología de Cuba. Materiales y métodos: 97 pacientes que tenían al menos un historial de 6 meses de infección crónica con VHB fueron reclutados en la propia institución desde enero 2016 hasta enero 2018. Se realizaron análisis estadísticos descriptivos para las características clínicas, estudios bioquímicos, virológicos, grado de dureza hepática (medido por elastografía transitoria) y terapia antiviral. Resultados: Todos los pacientes completaron el seguimiento; 61,9 por ciento eran varones y la mediana (rango) de edad fue de 46 (18-84) años. La media de tiempo desde el diagnóstico de la infección fue de 11,7 ± 8,9 años. El 61,9 por ciento tenían enfermedad inactiva sin fibrosis hepática o fibrosis ligera. Solamente el 2 por ciento eran negativos para el antígeno de superficie de la hepatitis B con el DNA cuantificable del VHB, el 81,4 por ciento tenían carga viral detectable y el 85,5 por ciento recibieron uno o más tratamientos antivirales, principalmente los análogos del nucleótido/sido. Conclusiones: Los pacientes con la infección crónica del VHB estudiados, en su mayoría se encuentran en fase inactiva de su enfermedad, sin evidencia significativa de daño hepático, con niveles detectables de viremia y han recibido algún tratamiento antiviral(AU)


Introduction: The effectiveness of the national immunization program has impacted on the reduction of the incidence of hepatitis B virus (HBV) infection in Cuba; however, the number of chronically infected patients is not negligible. These patients are diagnosed in the clinical practice, although the epidemiological studies that indicate the presence of the disease are insufficient. Objective: To describe the main clinical, biomolecular and immunological characteristics of patients with chronic hepatitis B virus infection treated at the National Institute of Gastroenterology, Havana, Cuba. Materials and methods: A total of 97 patients who had at least a 6-month history of chronic HBV infection were recruited at the above mentioned institution from January 2016 to January 2018. Descriptive statistical analyzes were performed to identify the clinical characteristics. Biochemical and virological studies, analysis of both liver stiffness values measured by transient elastography and use of antiviral therapy were also carried out. Results: All patients completed the follow-up. It was observed that 61,9 percent of them were male and the median (range) age was 46 (18-84) years. The mean time since the diagnosis of the infection was 11.7 ± 8,9 years. Inactive disease without liver fibrosis or light fibrosis was present in 61,9 percent. Only 2 percent were negative for hepatitis B surface antigen with quantitative analysis of HBV DNA; also, 81,4 percent of patients had detectable viral load and 85,5 percent received one or more antiviral treatments, mainly nucleotide analogues. Conclusions: The patients with chronic HBV infection studied are mostly in the inactive phase of their disease, without significant evidence of liver damage and detectable levels of viremia. All of them have received some antiviral treatment(AU)


Asunto(s)
Humanos , Masculino , Femenino , Hepatitis B Crónica/inmunología , Hepatitis B Crónica/epidemiología
5.
Rev. habanera cienc. méd ; 17(4): 527-539, jul.-ago. 2018. tab, graf
Artículo en Español | LILACS, CUMED | ID: biblio-978549

RESUMEN

Introducción: La difteria aún persiste en numerosos países. En Cuba, estudios realizados en diferentes grupos etarios han demostrado que existen niveles no protectores de antitoxina diftérica en la población, por lo que es necesario contar con métodos que permitan la estimación serológica de la inmunidad poblacional. La cuantificación de anticuerpos contra antígenos vacunales como la toxina diftérica es además un método útil, rápido y económico para evaluar la respuesta inmune. Objetivo: Validar un ensayo inmunoenzimático tipo ELISA para cuantificar los niveles de antitoxina diftérica en suero humano. Material y Método: Se realizó un estudio experimental de desarrollo tecnológico, en el cual se determinaron los valores óptimos de las variables que influyen en el resultado de un ensayo inmunoenzimático heterogéneo indirecto para la cuantificación de antitoxina diftérica, desarrollado en el laboratorio de Inmunología del Centro Nacional de Genética Médica de Cuba. La curva de calibración se evaluó contra el estándar de la OMS (Diphtheria Antitoxin Human Serum 00/496). Se realizó la validación analítica del método estandarizado. Resultados: Los coeficientes de variación intraensayo e interensayo fueron inferiores a 10 por ciento y 20 por ciento, respectivamente. En la exactitud y selectividad se encontraron valores de recobrado entre 90 y 110 por ciento. El paralelismo entre la curva estándar y las muestras estudiadas presentó un coeficiente de variación menor o igual a 10 por ciento. El límite de cuantificación fue 0,015 UI/mL y el de detección 0,0039 UI/mL. Conclusiones: El resultado obtenido en la precisión, exactitud y selectividad del ensayo inmunoenzimático tipo ELISA desarrollado demostró que puede ser utilizado en la práctica clínica para cuantificar los valores de antitoxina diftérica en suero humano(AU)


Introduction: Diphtheria still persists in many countries. In Cuba, studies conducted in different age groups have demonstrated that there are non-protective levels of diphtheria antitoxin in the population, so it is necessary to have methods that allow the serologic survey of population immunity. The quantification of antibodies against vaccine antigens such as diphtheria toxin is also a useful, rapid and economic method to evaluate the immune response. Objective: To validate an ELISA-type immune-enzymatic test to quantify the levels of diphtheria antitoxin in human serum. Material and Method: An experimental study of technological development was carried out in the Immunology Laboratory of the National Medical Genetics Center, Havana, Cuba. The optimal values ​​of the variables that influence on the result of the indirect heterogeneous immune-enzymatic test for the quantification of diphtheria antitoxin were determined. The calibration curve obtained was evaluated against the WHO standard (Diphtheria Antitoxin Human Serum 00/496). The analytical validation of the standardized method was performed. Results: The intra-assay and inter-assay coefficients of variation were less than 10 percent and 20 percent, respectively. Recovery values ​​between 90 and 110% were found in accuracy and selectivity. The parallelism between the standard curve and the samples studied showed a coefficient of variation lower or equal to 10 percent. The limit of quantification was 0,015 IU/mL and the one of detection was 0,0039 IU/mL. Conclusions: The result obtained in the precision, accuracy and selectivity of the ELISA-type immune-enzymatic test developed and validated in the National Medical Genetics Center demonstrated that it can be used in the clinical practice to quantify the values ​​of diphtheria antitoxin in human serum(AU)


Asunto(s)
Ensayo de Inmunoadsorción Enzimática/métodos , Antitoxina Diftérica/análisis , Difteria/prevención & control , Difteria/transmisión , Estudios de Validación como Asunto
6.
Rev. habanera cienc. méd ; 17(5): 669-680, set.-oct. 2018. tab, graf
Artículo en Español | LILACS, CUMED | ID: biblio-985615

RESUMEN

Introducción: El espectro del compromiso hepático en la enfermedad celíaca es muy amplio e incluye hepatopatías virales y autoinmunes. Objetivo: Caracterizar el comportamiento de los marcadores serológicos de hepatopatías virales y autoinmunes en pacientes celíacos adultos atendidos en el Instituto de Gastroenterología. Materiales y Métodos: Se realizó un estudio observacional descriptivo transversal en el período comprendido entre marzo de 2016 y marzo 2017 en 43 pacientes adultos celíacos atendidos en el Instituto de Gastroenterología de La Habana. A todos, previo consentimiento informado se les realizaron estudios bioquímicos y serológicos para identificar infección por virus de hepatitis B, C y respuesta inmune humoral frente a autoanticuerpos hepáticos y sistémicos. Para el análisis estadístico se emplearon distribuciones de frecuencia y para la comparación entre los grupos se utilizó la probabilidad exacta de Fisher. Se consideró significativo una p < 0,05. Resultados: El 58,1 por ciento de los pacientes presentó hipofosfatasemia y 14 por ciento hipertransaminasemia, sin coincidencias entre los casos registrados. El 100 por ciento de los celíacos fue negativo para el virus de hepatitis C. La positividad de autoanticuerpos hepáticos se registró entre 2,3 por ciento y 14 por ciento de los pacientes evaluados. Existió asociación significativa entre hipertransaminasemia y la presencia de anticuerpos séricos contra la transglutaminasa tisular. Conclusiones: La expresión de marcadores de autoinmunidad hepática en los pacientes celíacos evaluados es frecuente, no así la presencia de marcadores de hepatopatías virales(AU)


Introduction: The spectrum of hepatic involvement in celiac disease is very broad and includes viral and autoimmune hepatopathies. Objective: To characterize the behavior of serologic markers of viral and autoimmune hepatopathies in adult celiac patients treated at the Institute of Gastroenterology. Materials and Methods: A cross-sectional observational study was conducted in 43 adult celiac patients treated at the Institute of Gastroenterology of Havana from March 2016 to March 2017. Prior informed consent, biochemical and serologic studies were carried out in all cases, in order to identify hepatitis B and C virus infections and humoral immune response to liver and systemic autoantibodies. Frequency distributions were used for statistical analysis, and Fisher's exact test was used for the comparison between groups. Results: 58.1 percent of the patients presented hypophosphatasemia and hypertransaminasemia in 14 percent, with no coincidence between the cases recorded. The 100 percent of the celiac patients were negative for hepatitis C virus. The positivity of liver autoantibodies was recorded between 2,3 percent and 14 percent of the patients evaluated. There was a significant association between hypertransaminasemia and the presence of serum antibodies against tissue transglutaminase. Conclusions: The expression markers of liver autoimmunity in celiac patients was frequent, but not the presence of markers of viral hepatopathy(AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Enfermedades Autoinmunes/epidemiología , Enfermedad Celíaca/sangre , Hepatopatías/sangre , Epidemiología Descriptiva , Estudios Transversales , Estudio Observacional
7.
Artículo en Español | CUMED | ID: cum-73809

RESUMEN

Los anticuerpos son indispensables para una respuesta inmune efectiva contra patógenos. En las RASopatías, como la neurofibromatosis tipo 1, las proteínas mutadas tienen importantes funciones en la regulación del sistema inmune. Este trabajo tiene como objetivo identificar las manifestaciones clínicas de disregulación inmune y alteraciones de la respuesta inmune humoral en pacientes con Neurofibromatosis tipo 1. Se realizó un estudio descriptivo de serie de casos. Se estudiaron 8 pacientes pediátricos con diagnóstico clínico de neurofibromatosis tipo 1 procedentes de la consulta de Genética Médica del Hospital “Juan Manuel Márquez”. Se realizó cuantificación de inmunoglobulinas y de subclases de inmunoglobulinas G séricas, así como la determinación de la respuesta al toxoide tetánico y diftérico. Las infecciones recurrentes respiratorias fueron las manifestaciones clínicas de sospecha de disregulación inmune más frecuentes. El 50,0(percent) de los pacientes presentaron una disminución de inmunoglobulinas séricas, solo el 25,5(percent) y 12,5(percent) presentaron para una protección confiable de larga duración frente a los toxoides tetánico y diftérico, respectivamente. Los resultados obtenidos evidenciaron alteraciones de la respuesta inmune humoral y manifestaciones clínicas de disregulación inmune en pacientes con neurofibromatosis tipo 1, que justifican la necesidad de su evaluación por un especialista en inmunología…(AU)


Asunto(s)
Humanos , Masculino , Femenino , Anticuerpos/genética , Neurofibromatosis 1/genética , Inmunidad Humoral , Inmunoglobulinas/genética , Inmunoglobulina G
8.
Artículo en Español | CUMED | ID: cum-73641

RESUMEN

La melanosis neurocutánea es una rara enfermedad caracterizada por la presencia de nevomelanocítico gigante y lesiones melanocíticas del sistema nervioso central. Se han descritos casos sin manifestaciones neurológicas con estudios de imágenes negativos y con lesiones solo detectables mediante biopsia del Sistema Nervioso Central. Se presenta el caso de un niño de cuatro años de edad, con diagnóstico de melanosis neurocutánea e infecciones recurrentes del sistema respiratorio, principalmente amigdalitis y rinitis. En los estudios inmunológicos se observó disminución de los niveles de IgA, IgM e IgG2, así como del número de linfocitos CD19 positivos; el porciento de linfocitos CD4+ y CD8+ fue normal y presentó niveles no protectores de anticuerpos anti-difteria. Se diagnosticó una inmunodeficiencia humoral asociada con la enfermedad genética que presenta el paciente. Las alteraciones genéticas de la enfermedad de base sugieren que puede aparecer disregulación del sistema inmune en estos pacientes, como ocurrió en el caso estudiado, por lo que consideramos importante la valoración inmunológica en los pacientes con melanosis neurocutánea…(AU)


Asunto(s)
Humanos , Masculino , Femenino , Melanosis , Inmunoglobulinas , Inmunidad Humoral/genética , Sistema Inmunológico
9.
Rev. bioméd. (México) ; 28(3): 111-123, sep.-dic. 2017. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1003375

RESUMEN

Resumen Introducción Durante la etapa aguda de la infección por el Virus de la Hepatitis B (VHB) y el período inicial de una infección crónica, el DNA está en forma episomal (libre o extracromosomal) y se replica en el hepatocito produciendo, entre otros, viriones infectivos, DNA polimerasa y antígeno de superficie del virus (HBsAg). Objetivo Validar un inmunoensayo tipo ELISA para cuantificar los niveles de HBsAg en pacientes con hepatitis B crónica. Método Se realizó un estudio experimental de desarrollo tecnológico. Se llevó a cabo la normalización y validación de un inmunoensayo enzimático heterogéneo de doble anticuerpo para la cuantificación de HBsAg en sueros de seres humanos. 115 muestras de pacientes con hepatitis B crónica con resultados de carga viral se correlacionaron con las concentraciones de HBsAg. Resultados y discusión El método presentó coeficientes de variación intra e interensayo de 9,8 y 13,2% respectivamente. El rango de trabajo se estimó entre 0.15 y 60 ng/mL. El porcentaje de recuperación estuvo entre el 90 y 110% y el ajuste lineal de la curva estándar presentó un coeficiente de determinación superior a 0,99. La correlación alcanzada entre los niveles de DNA y la concentración de HBsAg fue de 62.5%. Conclusiones La evaluación del ELISA para la cuantificación de HBsAg desarrollado en el laboratorio mostró que cumple los parámetros de validación para su uso clínico.


Abstract Introduction During the acute phase of infection with Hepatitis B Virus (HBV) and the initial period of chronic infection, DNA is episomally (free or extrachromosomal) and replicates in hepatocytes producing among other virions, DNA polymerase and virus surface antigen (HBsAg). Objective Validate an ELISA to quantify HBsAg levels in patients with chronic hepatitis B. Method An experimental study of technological developmentwas conducted. The normalization and validation of heterogeneous double antibody enzyme linked inmunoassay for quantitation of HBsAg in human sera was carried out. 115 serum samples from patients with chronic hepatitis B with viral load results were correlated with its HBsAg concentrations. Results and discussion The developed method presented variation coefficients intra and interassay of 9.8 and 13.2% respectively. The working range was estimated between 0.15 and 60 ng/mL. The recovery rate was between 90 and 110% and the linear fit of the standard curve presented a determination coefficient greater than 0, 99. The correlation between the DNA levels and HBsAg concentration was 62.5%. Conclusions The assessment of the ELISA for quantitation of HBsAg developed in the laboratory showed that it achieved validation parameters for its clinical use.

10.
Rev cuba genet comunit ; 9(3): 36-46, 2015.
Artículo en Español | CUMED | ID: cum-71021

RESUMEN

Introducción: La integridad de la piel es fundamental para un buen funcionamiento del sistema inmune y una adecuada salud. Alteraciones del sistema inmune se describen en algunas genodermatosis, la morbimortalidad de estos pacientes está influenciada por disregulaciones del sistema inmune. El objetivo de este trabajo fue describir las manifestaciones clínicas y las alteraciones de la respuesta inmune humoral en pacientes cubanos con genodermatosis en edad pediátrica. Material y métodos: Se realizó un estudio descriptivo de corte transversal. La muestra estuvo constituida por 30 pacientes pediátricos con genodermatosis. La evaluación de la respuesta inmune incluyó la cuantificación de clases y subclases de inmunoglobulina mediante inmunodifusión radial simple y la determinación de los niveles de anticuerpos antitoxina tetánica y diftérica mediante ELISA. Resultados: Las infecciones recurrentes respiratorias (97(percent) fueron las manifestaciones clínicas de sospecha de disregulación inmune más frecuentes. El 63,3(percent) de los pacientes presentó alteración de la respuesta inmune humoral estudiada. El déficit de IgA e IgG 4 fueron la clase y subclase de inmunoglobulina G más observadas. Todos los pacientes presentaron niveles protectores de anti toxina tetánica y el 33(percent) de los pacientes presentaron niveles de antitoxina diftérica no adecuados para conferir protección. Conclusiones: En los pacientes con genodermatosis estudiados fue frecuente la presencia de infecciones y alteraciones de la respuesta inmune humoral, de ahí la importancia del estudio de los componentes del sistema inmune para lograr un mejor manejo de pacientes con esta enfermedad…(AU)


Asunto(s)
Humanos , Masculino , Femenino , Inmunoglobulinas , Sistema Inmunológico , Inmunodifusión
11.
Rev cuba genet comunit ; 8(1): 27-35, 2014.
Artículo en Español | CUMED | ID: cum-71027

RESUMEN

La morbimortalidad de los pacientes pediátricos con enfermedades genéticas puede estar influenciada por disregulaciones del sistema inmune. El objetivo de este trabajo fue describir las manifestaciones clínicas y las alteraciones de las inmunoglobulinas en un grupo de pacientes con enfermedades genéticas. Se realizó un estudio epidemiológico descriptivo en una serie de casos. La muestra estuvo constituida por 33 pacientes pediátricos con enfermedades genéticas a los que se les realizó hemograma completo y cuantificación de inmunoglobulinas G, M y A mediante turbidimetría. Las manifestaciones clínicas de sospecha de disregulación inmune más frecuentes fueron las infecciones respiratorias agudas recurrentes (95,0 (percent), las alergias respiratorias recurrentes (76,0 (percent), las neumopatías inflamatorias recurrentes (71,9(percent) las amigdalitis bacterianas recurrentes (51,0 (percent) las otitis media recurrentes (46,0 (percent). El 51,51(percent) presentó disminución de al menos un isotipo o clase de inmunoglobulinas y el 21,2 (percent) mostró más de una clase afectada. La disminución de la IgA fue la alteración más frecuente. Las manifestaciones clínicas de los pacientes con enfermedades genéticas se corresponden con las alteraciones de los niveles de inmunoglobulinas…(AU)


Asunto(s)
Humanos , Masculino , Femenino , Enfermedades Genéticas Congénitas , Sistema Inmunológico , Idiotipos de Inmunoglobulinas , Nefelometría y Turbidimetría
12.
Rev. habanera cienc. méd ; 12(4): 0-0, oct,.dic. 2013.
Artículo en Español | LILACS | ID: lil-697522

RESUMEN

Introducción: la cuantificación de antitoxina tetánica es útil para la evaluación de la respuesta inmune humoral frente a antígenos vacunales. Objetivo: desarrollar la estandarización y validación técnica de un ensayo de inmunoabsorción ligado a enzima (ELISA) de tipo indirecto para cuantificar antitoxina tetánica en suero humano. Material y Método: el estándar preparado para la curva del ensayo se calibró frente al preparado en el Instituto Finlay. Se normalizaron los indicadores óptimos para el desarrollo de cada paso de la técnica. Resultados y Discusión: durante la validación se alcanzó una buena precisión intraensayo e interensayo en todos los casos. Al evaluar el paralelismo el coeficiente de variación fue menor de 10%. El ensayo mostró una excelente exactitud, con valores de recuperación entre 90% y 110%. El límite de detección fue 0,002 UI/mL. La sensibilidad analítica alcanzada fue de 0,01 UI/mL. Conclusiones: el ensayo puede ser utilizado para la cuantificación de antitoxina tetánica en suero humano.


Introduction: the Titanic antitoxin quantification is useful to assess the immune response against vaccinal antigens. Objective: to develop a standardization and validation technique of the indirect ELISA to quantify titanic antitoxin in human serum. Materials and Methods: the standard preparing to the assay curve was calibrated front the preparing Finlay Institute. The optimal indicators were normalized to each technique step developed. Results: a good intra-assay precision was reach during validation in all cases. The coefficient of variation to parallelism was less than 10% and 110%. Detection limit was 0.002 UI/ ml. Analytic sensitivity reached was 0.01 UI/ ml. Conclusions: the assay may be used to quantify Titanic antitoxin in human serum.

13.
Rev. habanera cienc. méd ; 12(4): 0-0, oct,.dic. 2013.
Artículo en Español | CUMED | ID: cum-68751

RESUMEN

Introducción: la cuantificación de antitoxina tetánica es útil para la evaluación de la respuesta inmune humoral frente a antígenos vacunales.Objetivo: desarrollar la estandarización y validación técnica de un ensayo de inmunoabsorción ligado a enzima (ELISA) de tipo indirecto para cuantificar antitoxina tetánica en suero humano. Material y Método: el estándar preparado para la curva del ensayo se calibró frente al preparado en el Instituto Finlay. Se normalizaron los indicadores óptimos para el desarrollo de cada paso de la técnica. Resultados y Discusión: durante la validación se alcanzó una buena precisión intraensayo e interensayo en todos los casos. Al evaluar el paralelismo el coeficiente de variación fue menor de 10 por ciento. El ensayo mostró una excelente exactitud, con valores de recuperación entre 90 por ciento y 110 por ciento. El límite de detección fue 0,002 UI/mL. La sensibilidad analítica alcanzada fue de 0,01 UI/mL. Conclusiones: el ensayo puede ser utilizado para la cuantificación de antitoxina tetánica en suero humano(AU)


Introduction: the Titanic antitoxin quantification is useful to assess the immune response against vaccinal antigens. Objective: to develop a standardization and validation technique of the indirect ELISA to quantify titanic antitoxin in human serum. Materials and Methods: the standard preparing to the assay curve was calibrated front the preparing Finlay Institute. The optimal indicators were normalized to each technique step developed. Results: a good intra-assay precision was reach during validation in all cases. The coefficient of variation to parallelism was less than 10 percent and 110 percent. Detection limit was 0.002 UI/ ml. Analytic sensitivity reached was 0.01 UI/ ml. Conclusions: the assay may be used to quantify Titanic antitoxin in human serum(AU)


Asunto(s)
Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA