1.
J Cardiovasc Magn Reson ; 26(2): 101077, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39098573

RESUMEN

BACKGROUND: This study aimed to validate respiratory-resolved five-dimensional (5D) flow cardiovascular magnetic resonance (CMR) against real-time two-dimensional (2D) phase-contrast MRI, assess the impact of number of respiratory states, and measure the impact of respiration on hemodynamics in congenital heart disease (CHD) patients. METHODS: Respiratory-resolved 5D flow MRI-derived net and peak flow measurements were compared to real-time 2D phase-contrast MRI-derived measurements in 10 healthy volunteers. Pulmonary-to-systemic flow ratios (Qp:Qs) were measured in 19 CHD patients and aortopulmonary collateral burden was measured in 5 Fontan patients. Additionally, the impact of number of respiratory states on measured respiratory-driven net flow changes was investigated in 10 healthy volunteers and 19 CHD patients (shunt physiology, n = 11, single ventricle disease [SVD], n = 8). RESULTS: There was good agreement between 5D flow MRI and real-time 2D phase-contrast-derived net and peak flow. Respiratory-driven changes had a good correlation (rho = 0.64, p < 0.001). In healthy volunteers, fewer than four respiratory states reduced measured respiratory-driven flow changes in veins (5.2 mL/cycle, p < 0.001) and arteries (1.7 mL/cycle, p = 0.05). Respiration drove substantial venous net flow changes in SVD (64% change) and shunt patients (57% change). Respiration had significantly greater impact in SVD patients compared to shunt patients in the right and left pulmonary arteries (46% vs 15%, p = 0.003 and 59% vs 20%, p = 0.002). Qp:Qs varied by 37 ± 24% over respiration in SVD patients and 12 ± 20% in shunt patients. Aortopulmonary collateral burden varied by 118 ± 84% over respiration in Fontan patients. The smallest collateral burden was measured during active inspiration in all patients and the greatest burden was during active expiration in four of five patients. Reduced respiratory resolution blunted measured flow changes in the caval veins of shunt and SVD patients (p < 0.005). CONCLUSIONS: Respiratory-resolved 5D flow MRI measurements agree with real-time 2D phase contrast. Venous measurements are sensitive to number of respiratory states, whereas arterial measurements are more robust. Respiration has a substantial impact on caval vein flow, Qp:Qs, and collateral burden in CHD patients.

2.
J Cardiovasc Magn Reson ; 26(1): 101037, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38499269

RESUMEN

BACKGROUND: Free-running cardiac and respiratory motion-resolved whole-heart five-dimensional (5D) cardiovascular magnetic resonance (CMR) can reduce scan planning and provide a means of evaluating respiratory-driven changes in clinical parameters of interest. However, respiratory-resolved imaging can be limited by user-defined parameters which create trade-offs between residual artifact and motion blur. In this work, we develop and validate strategies for both correction of intra-bin and compensation of inter-bin respiratory motion to improve the quality of 5D CMR. METHODS: Each component of the reconstruction framework was systematically validated and compared to the previously established 5D approach using simulated free-running data (N = 50) and a cohort of 32 patients with congenital heart disease. The impact of intra-bin respiratory motion correction was evaluated in terms of image sharpness while inter-bin respiratory motion compensation was evaluated in terms of reconstruction error, compression of respiratory motion, and image sharpness. The full reconstruction framework (intra-acquisition correction and inter-acquisition compensation of respiratory motion [IIMC] 5D) was evaluated in terms of image sharpness and scoring of image quality by expert reviewers. RESULTS: Intra-bin motion correction provides significantly (p < 0.001) sharper images for both simulated and patient data. Inter-bin motion compensation results in significant (p < 0.001) lower reconstruction error, lower motion compression, and higher sharpness in both simulated (10/11) and patient (9/11) data. The combined framework resulted in significantly (p < 0.001) sharper IIMC 5D reconstructions (End-expiration (End-Exp): 0.45 ± 0.09, End-inspiration (End-Ins): 0.46 ± 0.10) relative to the previously established 5D implementation (End-Exp: 0.43 ± 0.08, End-Ins: 0.39 ± 0.09). Similarly, image scoring by three expert reviewers was significantly (p < 0.001) higher using IIMC 5D (End-Exp: 3.39 ± 0.44, End-Ins: 3.32 ± 0.45) relative to 5D images (End-Exp: 3.02 ± 0.54, End-Ins: 2.45 ± 0.52). CONCLUSION: The proposed IIMC reconstruction significantly improves the quality of 5D whole-heart MRI. This may be exploited for higher resolution or abbreviated scanning. Further investigation of the diagnostic impact of this framework and comparison to gold standards is needed to understand its full clinical utility, including exploration of respiratory-driven changes in physiological measurements of interest.


Asunto(s)
Artefactos , Cardiopatías Congénitas , Interpretación de Imagen Asistida por Computador , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Femenino , Masculino , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Adulto , Adulto Joven , Imagen por Resonancia Magnética , Adolescente , Mecánica Respiratoria , Técnicas de Imagen Sincronizada Respiratorias , Niño , Persona de Mediana Edad , Respiración , Imagen por Resonancia Cinemagnética
3.
J Cardiovasc Magn Reson ; 26(1): 101006, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38309581

RESUMEN

BACKGROUND: Four-dimensional (4D) flow magnetic resonance imaging (MRI) often relies on the injection of gadolinium- or iron-oxide-based contrast agents to improve vessel delineation. In this work, a novel technique is developed to acquire and reconstruct 4D flow data with excellent dynamic visualization of blood vessels but without the need for contrast injection. Synchronization of Neighboring Acquisitions by Physiological Signals (SyNAPS) uses pilot tone (PT) navigation to retrospectively synchronize the reconstruction of two free-running three-dimensional radial acquisitions, to create co-registered anatomy and flow images. METHODS: Thirteen volunteers and two Marfan syndrome patients were scanned without contrast agent using one free-running fast interrupted steady-state (FISS) sequence and one free-running phase-contrast MRI (PC-MRI) sequence. PT signals spanning the two sequences were recorded for retrospective respiratory motion correction and cardiac binning. The magnitude and phase images reconstructed, respectively, from FISS and PC-MRI, were synchronized to create SyNAPS 4D flow datasets. Conventional two-dimensional (2D) flow data were acquired for reference in ascending (AAo) and descending aorta (DAo). The blood-to-myocardium contrast ratio, dynamic vessel area, net volume, and peak flow were used to compare SyNAPS 4D flow with Native 4D flow (without FISS information) and 2D flow. A score of 0-4 was given to each dataset by two blinded experts regarding the feasibility of performing vessel delineation. RESULTS: Blood-to-myocardium contrast ratio for SyNAPS 4D flow magnitude images (1.5 ± 0.3) was significantly higher than for Native 4D flow (0.7 ± 0.1, p < 0.01) and was comparable to 2D flow (2.3 ± 0.9, p = 0.02). Image quality scores of SyNAPS 4D flow from the experts (M.P.: 1.9 ± 0.3, E.T.: 2.5 ± 0.5) were overall significantly higher than the scores from Native 4D flow (M.P.: 1.6 ± 0.6, p = 0.03, E.T.: 0.8 ± 0.4, p < 0.01) but still significantly lower than the scores from the reference 2D flow datasets (M.P.: 2.8 ± 0.4, p < 0.01, E.T.: 3.5 ± 0.7, p < 0.01). The Pearson correlation coefficient between the dynamic vessel area measured on SyNAPS 4D flow and that from 2D flow was 0.69 ± 0.24 for the AAo and 0.83 ± 0.10 for the DAo, whereas the Pearson correlation between Native 4D flow and 2D flow measurements was 0.12 ± 0.48 for the AAo and 0.08 ± 0.39 for the DAo. Linear correlations between SyNAPS 4D flow and 2D flow measurements of net volume (r2 = 0.83) and peak flow (r2 = 0.87) were larger than the correlations between Native 4D flow and 2D flow measurements of net volume (r2 = 0.79) and peak flow (r2 = 0.76). CONCLUSION: The feasibility and utility of SyNAPS were demonstrated for joint whole-heart anatomical and flow MRI without requiring electrocardiography gating, respiratory navigators, or contrast agents. Using SyNAPS, a high-contrast anatomical imaging sequence can be used to improve 4D flow measurements that often suffer from poor delineation of vessel boundaries in the absence of contrast agents.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Síndrome de Marfan , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Humanos , Velocidad del Flujo Sanguíneo , Adulto , Masculino , Síndrome de Marfan/fisiopatología , Femenino , Adulto Joven , Estudios de Casos y Controles , Angiografía por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios de Factibilidad , Hemodinámica , Imagen de Perfusión/métodos , Medios de Contraste/administración & dosificación , Factores de Tiempo , Persona de Mediana Edad
4.
MAGMA ; 37(3): 429-438, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38743377

RESUMEN

OBJECT: To enable high-quality physics-guided deep learning (PG-DL) reconstruction of large-scale 3D non-Cartesian coronary MRI by overcoming challenges of hardware limitations and limited training data availability. MATERIALS AND METHODS: While PG-DL has emerged as a powerful image reconstruction method, its application to large-scale 3D non-Cartesian MRI is hindered by hardware limitations and limited availability of training data. We combine several recent advances in deep learning and MRI reconstruction to tackle the former challenge, and we further propose a 2.5D reconstruction using 2D convolutional neural networks, which treat 3D volumes as batches of 2D images to train the network with a limited amount of training data. Both 3D and 2.5D variants of the PG-DL networks were compared to conventional methods for high-resolution 3D kooshball coronary MRI. RESULTS: Proposed PG-DL reconstructions of 3D non-Cartesian coronary MRI with 3D and 2.5D processing outperformed all conventional methods both quantitatively and qualitatively in terms of image assessment by an experienced cardiologist. The 2.5D variant further improved vessel sharpness compared to 3D processing, and scored higher in terms of qualitative image quality. DISCUSSION: PG-DL reconstruction of large-scale 3D non-Cartesian MRI without compromising image size or network complexity is achieved, and the proposed 2.5D processing enables high-quality reconstruction with limited training data.


Asunto(s)
Vasos Coronarios , Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Imagen por Resonancia Magnética , Redes Neurales de la Computación , Humanos , Imagenología Tridimensional/métodos , Vasos Coronarios/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Física
5.
Magn Reson Med ; 90(3): 922-938, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37103471

RESUMEN

PURPOSE: To develop a free-running 3D radial whole-heart multiecho gradient echo (ME-GRE) framework for cardiac- and respiratory-motion-resolved fat fraction (FF) quantification. METHODS: (NTE = 8) readouts optimized for water-fat separation and quantification were integrated within a continuous non-electrocardiogram-triggered free-breathing 3D radial GRE acquisition. Motion resolution was achieved with pilot tone (PT) navigation, and the extracted cardiac and respiratory signals were compared to those obtained with self-gating (SG). After extra-dimensional golden-angle radial sparse parallel-based image reconstruction, FF, R2 *, and B0 maps, as well as fat and water images were generated with a maximum-likelihood fitting algorithm. The framework was tested in a fat-water phantom and in 10 healthy volunteers at 1.5 T using NTE = 4 and NTE = 8 echoes. The separated images and maps were compared with a standard free-breathing electrocardiogram (ECG)-triggered acquisition. RESULTS: The method was validated in vivo, and physiological motion was resolved over all collected echoes. Across volunteers, PT provided respiratory and cardiac signals in agreement (r = 0.91 and r = 0.72) with SG of the first echo, and a higher correlation to the ECG (0.1% of missed triggers for PT vs. 5.9% for SG). The framework enabled pericardial fat imaging and quantification throughout the cardiac cycle, revealing a decrease in FF at end-systole by 11.4% ± 3.1% across volunteers (p < 0.0001). Motion-resolved end-diastolic 3D FF maps showed good correlation with ECG-triggered measurements (FF bias of -1.06%). A significant difference in free-running FF measured with NTE = 4 and NTE = 8 was found (p < 0.0001 in sub-cutaneous fat and p < 0.01 in pericardial fat). CONCLUSION: Free-running fat fraction mapping was validated at 1.5 T, enabling ME-GRE-based fat quantification with NTE = 8 echoes in 6:15 min.


Asunto(s)
Corazón , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Corazón/diagnóstico por imagen , Electrocardiografía , Procesamiento de Imagen Asistido por Computador/métodos , Respiración , Imagenología Tridimensional/métodos
6.
Magn Reson Med ; 90(1): 117-132, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36877140

RESUMEN

PURPOSE: To validate a respiratory motion correction method called focused navigation (fNAV) for free-running radial whole-heart 4D flow MRI. METHODS: Using fNAV, respiratory signals derived from radial readouts are converted into three orthogonal displacements, which are then used to correct respiratory motion in 4D flow datasets. Hundred 4D flow acquisitions were simulated with non-rigid respiratory motion and used for validation. The difference between generated and fNAV displacement coefficients was calculated. Vessel area and flow measurements from 4D flow reconstructions with (fNAV) and without (uncorrected) motion correction were compared to the motion-free ground-truth. In 25 patients, the same measurements were compared between fNAV 4D flow, 2D flow, navigator-gated Cartesian 4D flow, and uncorrected 4D flow datasets. RESULTS: For simulated data, the average difference between generated and fNAV displacement coefficients was 0.04 ± $$ \pm $$ 0.32 mm and 0.31 ± $$ \pm $$ 0.35 mm in the x and y directions, respectively. In the z direction, this difference was region-dependent (0.02 ± $$ \pm $$ 0.51 mm up to 5.85 ± $$ \pm $$ 3.41 mm). For all measurements (vessel area, net volume, and peak flow), the average difference from ground truth was higher for uncorrected 4D flow datasets (0.32 ± $$ \pm $$ 0.11 cm2 , 11.1 ± $$ \pm $$ 3.5 mL, and 22.3 ± $$ \pm $$ 6.0 mL/s) than for fNAV 4D flow datasets (0.10 ± $$ \pm $$ 0.03 cm2 , 2.6 ± $$ \pm $$ 0.7 mL, and 5.1 ± 0 $$ \pm 0 $$ .9 mL/s, p < 0.05). In vivo, average vessel area measurements were 4.92 ± $$ \pm $$ 2.95 cm2 , 5.06 ± $$ \pm $$ 2.64 cm2 , 4.87 ± $$ \pm $$ 2.57 cm2 , 4.87 ± $$ \pm $$ 2.69 cm2 , for 2D flow and fNAV, navigator-gated and uncorrected 4D flow datasets, respectively. In the ascending aorta, all 4D flow datasets except for the fNAV reconstruction had significantly different vessel area measurements from 2D flow. Overall, 2D flow datasets demonstrated the strongest correlation to fNAV 4D flow for both net volume (r2  = 0.92) and peak flow (r2  = 0.94), followed by navigator-gated 4D flow (r2  = 0.83 and r2  = 0.86, respectively), and uncorrected 4D flow (r2  = 0.69 and r2  = 0.86, respectively). CONCLUSION: fNAV corrected respiratory motion in vitro and in vivo, resulting in fNAV 4D flow measurements that are comparable to those derived from 2D flow and navigator-gated Cartesian 4D flow datasets, with improvements over those from uncorrected 4D flow.


Asunto(s)
Imagen por Resonancia Magnética , Frecuencia Respiratoria , Humanos , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Aorta , Imagenología Tridimensional/métodos
7.
Magn Reson Med ; 87(2): 718-732, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34611923

RESUMEN

PURPOSE: In this work, we integrated the pilot tone (PT) navigation system into a reconstruction framework for respiratory and cardiac motion-resolved 5D flow. We tested the hypotheses that PT would provide equivalent respiratory curves, cardiac triggers, and corresponding flow measurements to a previously established self-gating (SG) technique while being independent from changes to the acquisition parameters. METHODS: Fifteen volunteers and 9 patients were scanned with a free-running 5D flow sequence, with PT integrated. Respiratory curves and cardiac triggers from PT and SG were compared across all subjects. Flow measurements from 5D flow reconstructions using both PT and SG were compared to each other and to a reference electrocardiogram-gated and respiratory triggered 4D flow acquisition. Radial trajectories with variable readouts per interleave were also tested in 1 subject to compare cardiac trigger quality between PT and SG. RESULTS: The correlation between PT and SG respiratory curves were 0.95 ± 0.06 for volunteers and 0.95 ± 0.04 for patients. Heartbeat duration measurements in volunteers and patients showed a bias to electrocardiogram measurements of, respectively, 0.16 ± 64.94 ms and 0.01 ± 39.29 ms for PT versus electrocardiogram and of 0.24 ± 63.68 ms and 0.09 ± 32.79 ms for SG versus electrocardiogram. No significant differences were reported for the flow measurements between 5D flow PT and from 5D flow SG. A decrease in the cardiac triggering quality of SG was observed for increasing readouts per interleave, whereas PT quality remained constant. CONCLUSION: PT has been successfully integrated in 5D flow MRI and has shown equivalent results to the previously described 5D flow SG technique, while being completely acquisition-independent.


Asunto(s)
Corazón , Imagen por Resonancia Magnética , Electrocardiografía , Corazón/diagnóstico por imagen , Humanos , Movimiento (Física) , Respiración , Frecuencia Respiratoria
8.
J Cardiovasc Magn Reson ; 24(1): 39, 2022 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-35754040

RESUMEN

BACKGROUND: Coronary cardiovascular magnetic resonance angiography (CCMRA) of congenital heart disease (CHD) in pediatric patients requires accurate planning, adequate sequence parameter adjustments, lengthy scanning sessions, and significant involvement from highly trained personnel. Anesthesia and intubation are commonplace to minimize movements and control respiration in younger subjects. To address the above concerns and provide a single-click imaging solution, we applied our free-running framework for fully self-gated (SG) free-breathing 5D whole-heart CCMRA to CHD patients after ferumoxytol injection. We tested the hypothesis that spatial and motion resolution suffice to visualize coronary artery ostia in a cohort of CHD subjects, both for intubated and free-breathing acquisitions. METHODS: In 18 pediatric CHD patients, non-electrocardiogram (ECG) triggered 5D free-running gradient echo CCMRA with whole-heart 1 mm3 isotropic spatial resolution was performed in seven minutes on a 1.5T CMR scanner. Eleven patients were anesthetized and intubated, while seven were breathing freely without anesthesia. All patients were slowly injected with ferumoxytol (4 mg/kg) over 15 minutes. Cardiac and respiratory motion-resolved 5D images were reconstructed with a fully SG approach. To evaluate the performance of motion resolution, visibility of coronary artery origins was assessed. Intubated and free-breathing patient sub-groups were compared for image quality using coronary artery length and conspicuity as well as lung-liver interface sharpness. RESULTS: Data collection using the free-running framework was successful in all patients in less than 8 min; scan planning was very simple without the need for parameter adjustments, while no ECG lead placement and triggering was required. From the resulting SG 5D motion-resolved reconstructed images, coronary artery origins could be retrospectively extracted in 90% of the cases. These general findings applied to both intubated and free-breathing pediatric patients (no difference in terms of lung-liver interface sharpness), while image quality and coronary conspicuity between both cohorts was very similar. CONCLUSIONS: A simple-to-use push-button framework for 5D whole-heart CCMRA was successfully employed in pediatric CHD patients with ferumoxytol injection. This approach, working without any external gating and for a wide range of heart rates and body sizes provided excellent definition of cardiac anatomy for both intubated and free-breathing patients.


Asunto(s)
Cardiopatías Congénitas , Angiografía por Resonancia Magnética , Niño , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Óxido Ferrosoférrico , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/patología , Humanos , Imagenología Tridimensional/métodos , Pulmón , Angiografía por Resonancia Magnética/métodos , Valor Predictivo de las Pruebas , Respiración , Estudios Retrospectivos
9.
Magn Reson Med ; 86(1): 213-229, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33624348

RESUMEN

PURPOSE: Whole-heart MRA techniques typically target predetermined motion states, address cardiac and respiratory dynamics independently, and require either complex planning or computationally demanding reconstructions. In contrast, we developed a fast data-driven reconstruction algorithm with minimal physiological assumptions and compatibility with ungated free-running sequences. THEORY AND METHODS: We propose a similarity-driven multi-dimensional binning algorithm (SIMBA) that clusters continuously acquired k-space data to find a motion-consistent subset for whole-heart MRA reconstruction. Free-running 3D radial data sets from 12 non-contrast-enhanced scans of healthy volunteers and six ferumoxytol-enhanced scans of pediatric cardiac patients were reconstructed with non-motion-suppressed regridding of all the acquired data ("All Data"), with SIMBA, and with a previously published free-running framework (FRF) that uses cardiac and respiratory self-gating and compressed sensing. Images were compared for blood-myocardium sharpness and contrast ratio, visibility of coronary artery ostia, and right coronary artery sharpness. RESULTS: Both the 20-second SIMBA reconstruction and FRF provided significantly higher blood-myocardium sharpness than All Data in both patients and volunteers (P < .05). The SIMBA reconstruction provided significantly sharper blood-myocardium interfaces than FRF in volunteers (P < .001) and higher blood-myocardium contrast ratio than All Data and FRF, both in volunteers and patients (P < .05). Significantly more ostia could be visualized with both SIMBA (31 of 36) and FRF (34 of 36) than with All Data (4 of 36) (P < .001). Inferior right coronary artery sharpness using SIMBA versus FRF was observed (volunteers: SIMBA 36.1 ± 8.1%, FRF 40.4 ± 8.9%; patients: SIMBA 35.9 ± 7.7%, FRF 40.3 ± 6.1%, P = not significant). CONCLUSION: The SIMBA technique enabled a fast, data-driven reconstruction of free-running whole-heart MRA with image quality superior to All Data and similar to the more time-consuming FRF reconstruction.


Asunto(s)
Imagenología Tridimensional , Angiografía por Resonancia Magnética , Algoritmos , Niño , Vasos Coronarios/diagnóstico por imagen , Humanos , Movimiento (Física)
10.
J Magn Reson Imaging ; 53(2): 540-551, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32815242

RESUMEN

BACKGROUND: Phase contrast MRI in the great vessels is a potential clinical tool for managing fetal pathologies. One challenge is the uncontrollable fetal motion, potentially corrupting flow quantifications. PURPOSE: To demonstrate improvements in fetal blood flow quantification in great vessels using retrospectively motion-corrected golden-angle radial phase contrast MRI relative to Cartesian phase contrast MRI. STUDY TYPE: Method comparison. PHANTOM/SUBJECTS: Computer simulation. Seventeen pregnant volunteers. FIELD STRENGTH/SEQUENCE: 1.5T and 3T. Cartesian and golden-angle radial phase contrast MRI. ASSESSMENT: Through computer simulations, radial (with and without retrospective motion correction) and Cartesian phase contrast MRI were compared using flow deviations. in vivo Cartesian and radial phase contrast MRI measurements and reconstruction qualities were compared in pregnancies. Cartesian data were reconstructed into gated reconstructions (CINEs) after cardiac gating with metric optimized gating (MOG). For radial data, real-time reconstructions were performed for motion correction and MOG followed by CINE reconstructions. STATISTICAL TESTS: Wilcoxon signed-rank test. Linear regression. Bland-Altman plots. Student's t-test. RESULTS: Simulations showed significant improvements (P < 0.05) in flow accuracy and reconstruction quality with motion correction ([mean/peak] flow errors with ±5 mm motion corruption: Cartesian [35 ± 1/115 ± 7] mL/s, motion uncorrected radial [25 ± 1/75 ± 2] mL/s and motion-corrected radial [1.0 ± 0.5/-5 ± 1] mL/s). in vivo Cartesian reconstructions without motion correction had lower quality than the motion-corrected radial reconstructions (P < 0.05). Across all fetal mean flow measurements, the bias [limits of agreement] between the two measurements were -0.2 [-76, 75] mL/min/kg, while the linear regression coefficients were (Mradial = 0.81 × MCartesian + 29.8 [mL/min/kg], r2 = 0.67). The corresponding measures for the peak fetal flows were -23 [-214, 167] mL/min/kg and (Pradial = 0.95 × PCartesian -1.2 [mL/min/kg], r2 = 0.80). Cartesian reconstructions of low quality showed significantly higher estimated mean and peak (P < 0.05) flows than the corresponding radial reconstructions. DATA CONCLUSION: Simulations showed that radial phase contrast MRI with motion compensation improved flow accuracy. For fetal measurements, motion-corrected radial reconstructions showed better image quality than, and different flow values from, Cartesian reconstructions. Level of Evidence 1. Technical Efficacy Stage 1. J. MAGN. RESON. IMAGING 2021;53:540-551.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Simulación por Computador , Femenino , Humanos , Movimiento (Física) , Embarazo , Reproducibilidad de los Resultados , Estudios Retrospectivos
11.
J Cardiovasc Magn Reson ; 23(1): 33, 2021 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-33775246

RESUMEN

BACKGROUND: Radial self-navigated (RSN) whole-heart coronary cardiovascular magnetic resonance angiography (CCMRA) is a free-breathing technique that estimates and corrects for respiratory motion. However, RSN has been limited to a 1D rigid correction which is often insufficient for patients with complex respiratory patterns. The goal of this work is therefore to improve the robustness and quality of 3D radial CCMRA by incorporating both 3D motion information and nonrigid intra-acquisition correction of the data into a framework called focused navigation (fNAV). METHODS: We applied fNAV to 500 data sets from a numerical simulation, 22 healthy subjects, and 549 cardiac patients. In each of these cohorts we compared fNAV to RSN and respiratory resolved extradimensional golden-angle radial sparse parallel (XD-GRASP) reconstructions of the same data. Reconstruction times for each method were recorded. Motion estimate accuracy was measured as the correlation between fNAV and ground truth for simulations, and fNAV and image registration for in vivo data. Percent vessel sharpness was measured in all simulated data sets and healthy subjects, and a subset of patients. Finally, subjective image quality analysis was performed by a blinded expert reviewer who chose the best image for each in vivo data set and scored on a Likert scale 0-4 in a subset of patients by two reviewers in consensus. RESULTS: The reconstruction time for fNAV images was significantly higher than RSN (6.1 ± 2.1 min vs 1.4 ± 0.3, min, p < 0.025) but significantly lower than XD-GRASP (25.6 ± 7.1, min, p < 0.025). Overall, there is high correlation between the fNAV and reference displacement estimates across all data sets (0.73 ± 0.29). For simulated data, healthy subjects, and patients, fNAV lead to significantly sharper coronary arteries than all other reconstruction methods (p < 0.01). Finally, in a blinded evaluation by an expert reviewer fNAV was chosen as the best image in 444 out of 571 data sets (78%; p < 0.001) and consensus grades of fNAV images (2.6 ± 0.6) were significantly higher (p < 0.05) than uncorrected (1.7 ± 0.7), RSN (1.9 ± 0.6), and XD-GRASP (1.8 ± 0.8). CONCLUSION: fNAV is a promising technique for improving the quality of RSN free-breathing 3D whole-heart CCMRA. This novel approach to respiratory self-navigation can derive 3D nonrigid motion estimations from an acquired 1D signal yielding statistically significant improvement in image sharpness relative to 1D translational correction as well as XD-GRASP reconstructions. Further study of the diagnostic impact of this technique is therefore warranted to evaluate its full clinical utility.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Angiografía por Resonancia Magnética , Adulto , Anciano , Estudios de Casos y Controles , Simulación por Computador , Enfermedad Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Movimiento , Análisis Numérico Asistido por Computador , Valor Predictivo de las Pruebas , Respiración , Adulto Joven
12.
Magn Reson Med ; 84(3): 1470-1485, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32144824

RESUMEN

PURPOSE: To implement, optimize, and characterize lipid-insensitive binomial off-resonant RF excitation (LIBRE) pulses for fat-suppressed fully self-gated free-running 5D cardiac MRI. METHODS: Bloch equation simulations were used to optimize LIBRE parameter settings in non-interrupted bSSFP prior to in vitro validation. Thus, optimized LIBRE pulses were subsequently applied to free-running coronary MRA in 20 human adult subjects, where resulting images were quantitatively compared to those obtained with non-fat-suppressing excitation (SP), conventional 1-2-1 water excitation (WE), and a previously published interrupted free-running (IFR) sequence. SAR and scan times were recorded. Respiratory-and-cardiac-motion-resolved images were reconstructed with XD-GRASP, and contrast ratios, coronary artery detection rate, vessel length, and vessel sharpness were computed. RESULTS: The numerically optimized LIBRE parameters were successfully validated in vitro. In vivo, LIBRE had the lowest SAR and a scan time that was similar to that of WE yet 18% shorter than that of IFR. LIBRE improved blood-fat contrast when compared to SP, WE, and IFR, vessel detection relative to SP and IFR, and vessel sharpness when compared to WE and IFR (for example, for the left main and anterior descending coronary artery, 51.5% ± 10.2% [LIBRE] versus 42.1% ± 6.8% [IFR]). Vessel length measurements remained unchanged for all investigated methods. CONCLUSION: LIBRE enabled fully self-gated non-interrupted free-running 5D bSSFP imaging of the heart at 1.5T with suppressed fat signal. Measures of image quality, vessel conspicuity, and scan time compared favorably to those obtained with the more conventional non-interrupted WE and the previously published IFR, while SAR reduction offers added flexibility.


Asunto(s)
Corazón , Agua , Adulto , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Lípidos , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética
13.
Magn Reson Med ; 83(1): 45-55, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31452244

RESUMEN

PURPOSE: To implement, optimize, and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5 tesla (T) and 3T. METHODS: FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics and to determine parameter ranges (number of readouts [NR] per FISS module and TR) for effective fat suppression. Subsequently, free-running FISS data were collected in 10 healthy volunteers and images were reconstructed with compressed sensing. All acquisitions were compared with a continuous balanced steady-state free precession version of the same sequence, and both fat suppression and scan times were analyzed. RESULTS: Simulations demonstrate a variable width and location of suppression bands in FISS that were dependent on TR and NR. For a fat suppression bandwidth of 100 Hz and NR ≤ 8, simulations demonstrated that a TR between 2.2 ms and 3.0 ms is required at 1.5T, whereas a range of 3.0 ms to 3.5 ms applies at 3T. Fat signal increases with NR. These findings were corroborated in phantom experiments. In volunteers, fat SNR was significantly decreased using FISS compared with balanced steady-state free precession (P < 0.05) at both field strengths. After protocol optimization, high-resolution (1.1 mm3 ) 5D whole-heart free-running FISS can be performed with effective fat suppression in under 8 min at 1.5T and 3T at a modest scan time increase compared to balanced steady-state free precession. CONCLUSION: An optimal FISS parameter range was determined enabling natively fat-suppressed 5D whole-heart free-running MRI with a single continuous scan at 1.5T and 3T, demonstrating potential for cardiac imaging and noncontrast angiography.


Asunto(s)
Radicales Libres , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Técnicas de Imagen Sincronizada Respiratorias , Algoritmos , Simulación por Computador , Angiografía Coronaria , Electrocardiografía , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Teóricos , Movimiento (Física) , Distribución Normal , Fantasmas de Imagen , Relación Señal-Ruido
14.
J Cardiovasc Magn Reson ; 21(1): 29, 2019 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-31118056

RESUMEN

BACKGROUND: Validating new techniques for fetal cardiovascular magnetic resonance (CMR) is challenging due to random fetal movement that precludes repeat measurements. Consequently, fetal CMR development has been largely performed using physical phantoms or postnatal volunteers. In this work, we present an open-source simulation designed to aid in the development and validation of new approaches for fetal CMR. Our approach, fetal extended Cardiac-Torso cardiovascular magnetic resonance imaging (Fetal XCMR), builds on established methods for simulating CMR acquisitions but is tailored toward the dynamic physiology of the fetal heart and body. We present comparisons between the Fetal XCMR phantom and data acquired in utero, resulting in image quality, anatomy, tissue signals and contrast. METHODS: Existing extended Cardiac-Torso models are modified to create maternal and fetal anatomy, combined according to simulated motion, mapped to CMR contrast, and converted to CMR data. To provide a comparison between the proposed simulation and experimental fetal CMR images acquired in utero, images from a typical scan of a pregnant woman are included and simulated acquisitions were generated using matching CMR parameters, motion and noise levels. Three reconstruction (static, real-time, and CINE), and two motion estimation methods (translational motion, fetal heart rate) from data acquired in transverse, sagittal, coronal, and short-axis planes of the fetal heart were performed to compare to in utero acquisitions and demonstrate feasibility of the proposed simulation framework. RESULTS: Overall, CMR contrast, morphologies, and relative proportions of the maternal and fetal anatomy are well represented by the Fetal XCMR images when comparing the simulation to static images acquired in utero. Additionally, visualization of maternal respiratory and fetal cardiac motion is comparable between Fetal XCMR and in utero real-time images. Finally, high quality CINE image reconstructions provide excellent delineation of fetal cardiac anatomy and temporal dynamics for both data types. CONCLUSION: The fetal CMR phantom provides a new method for evaluating fetal CMR acquisition and reconstruction methods by simulating the underlying anatomy and physiology. As the field of fetal CMR continues to grow, new methods will become available and require careful validation. The fetal CMR phantom is therefore a powerful and convenient tool in the continued development of fetal cardiac imaging.


Asunto(s)
Simulación por Computador , Corazón Fetal/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Modelos Cardiovasculares , Fantasmas de Imagen , Diagnóstico Prenatal/instrumentación , Puntos Anatómicos de Referencia , Femenino , Humanos , Análisis Numérico Asistido por Computador , Valor Predictivo de las Pruebas , Embarazo , Reproducibilidad de los Resultados
15.
J Cardiovasc Magn Reson ; 20(1): 77, 2018 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-30486832

RESUMEN

PURPOSE: To image multidimensional flow in fetuses using golden-angle radial phase contrast cardiovascular magnetic resonance (PC-CMR) with motion correction and retrospective gating. METHODS: A novel PC-CMR method was developed using an ungated golden-angle radial acquisition with continuously incremented velocity encoding. Healthy subjects (n = 5, 27 ± 3 years, males) and pregnant females (n = 5, 34 ± 2 weeks gestation) were imaged at 3 T using the proposed sequence. Real-time reconstructions were first performed for retrospective motion correction and cardiac gating (using metric optimized gating, MOG). CINE reconstructions of multidimensional flow were then performed using the corrected and gated data. RESULTS: In adults, flows obtained using the proposed method agreed strongly with those obtained using a conventionally gated Cartesian acquisition. Across the five adults, bias and limits of agreement were - 1.0 cm/s and [- 5.1, 3.2] cm/s for mean velocities and - 1.1 cm/s and [- 6.5, 4.3] cm/s for peak velocities. Temporal correlation between corresponding waveforms was also high (R~ 0.98). Calculated timing errors between MOG and pulse-gating RR intervals were low (~ 20 ms). First insights into multidimensional fetal blood flows were achieved. Inter-subject consistency in fetal descending aortic flows (n = 3) was strong with an average velocity of 27.1 ± 0.4 cm/s, peak systolic velocity of 70.0 ± 1.8 cm/s and an intra-class correlation coefficient of 0.95 between the velocity waveforms. In one fetal case, high flow waveform reproducibility was demonstrated in the ascending aorta (R = 0.97) and main pulmonary artery (R = 0.99). CONCLUSION: Multidimensional PC-CMR of fetal flow was developed and validated, incorporating retrospective motion compensation and cardiac gating. Using this method, the first quantification and visualization of multidimensional fetal blood flow was achieved using CMR.


Asunto(s)
Circulación Coronaria , Corazón Fetal/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Diagnóstico Prenatal/métodos , Adulto , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Velocidad del Flujo Sanguíneo , Técnicas de Imagen Sincronizada Cardíacas , Estudios de Casos y Controles , Estudios de Factibilidad , Femenino , Corazón Fetal/fisiopatología , Edad Gestacional , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Embarazo , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Reproducibilidad de los Resultados
16.
Magn Reson Med ; 77(6): 2125-2135, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27254315

RESUMEN

PURPOSE: To develop and validate a method for accelerated time-resolved imaging of the fetal heart using a combination of compressed sensing (CS) and metric optimized gating (MOG). THEORY AND METHODS: Joint optimization of CS and MOG reconstructions was used to suppress competing artifact from random undersampling and ungated cardiac motion. Retrospectively and prospectively undersampled adult and fetal data were used to validate the proposed reconstruction algorithm qualitatively based on visual assessment, and quantitatively based on reconstruction error, blur, and MOG timing error. RESULTS: Excellent agreement was observed between the fully sampled and retrospectively undersampled reconstructions, up to an undersampling factor of four. Visually, differences between ECG and MOG reconstructions of adult data were negligible. This was consistent with quantitative comparisons of reconstruction error (RMSEECG = 0.07-0.13; RMSEMOG = 0.08-0.13), and image blur (BECG = 1.03-1.20; BMOG = 1.03-1.20). The calculated MOG timing error (2-42 ms) was comparable to the acquired temporal resolution (∼60 ms). Quantitative evaluation of retrospectively undersampled (R = 2-8) fetal data (RMSEMOG = 0.06-0.12; BMOG = 1.04-1.27) was comparable to the adult volunteer results. CONCLUSION: CS-MOG for dynamic imaging of the fetal heart was developed and validated. Using CS-MOG, images were obtained up to four times faster than conventional acquisitions. Magn Reson Med 77:2125-2135, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Compresión de Datos/métodos , Corazón Fetal/anatomía & histología , Corazón Fetal/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagen por Resonancia Cinemagnética/métodos , Ultrasonografía Prenatal/métodos , Artefactos , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Movimiento (Física) , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
17.
J Cardiovasc Magn Reson ; 19(1): 29, 2017 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-28316282

RESUMEN

BACKGROUND: To develop and evaluate a reconstruction framework for high resolution time-resolved CMR of the fetal heart in the presence of motion. METHODS: Data were acquired using a golden angle radial trajectory in seven fetal subjects and reconstructed as real-time images to detect fetal movement. Data acquired during through-plane motion were discarded whereas in-plane motion was corrected. A fetal cardiac gating signal was extracted to sort the corrected data by cardiac phase, allowing reconstruction of cine images. The quality of motion corrected images and the effect of data undersampling were quantified using separate expressions for spatial blur and image error. RESULTS: Motion corrected reordered cine reconstructions (127 slices) showed improved image quality relative to both uncorrected cines and corresponding real-time images across a range of root-mean-squared (RMS) displacements (0.3-3.7 mm) and fetal heart rates (119-176 bpm). The relative spatial blur between cines with and without motion correction increased with in-plane RMS displacement leading to an effective decrease in the effective spatial resolution for images without motion correction. Image error between undersampled and reference images was less than 10% for reconstructions using 750 or more spokes, yielding a minimum acceptable scan time of approximately 4 s/slice during quiescent through plane motion. CONCLUSIONS: By rejecting data corrupted by through-plane motion, and correcting data corrupted by in-plane translation, the proposed reconstruction framework accounts for common sources of motion artifact (gross fetal movement, maternal respiration, fetal cardiac contraction) to produce high quality images of the fetal heart.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Contracción Miocárdica , Diagnóstico Prenatal/métodos , Fenómenos Biomecánicos , Estudios de Casos y Controles , Femenino , Corazón Fetal/fisiopatología , Edad Gestacional , Cardiopatías Congénitas/fisiopatología , Humanos , Valor Predictivo de las Pruebas , Embarazo , Factores de Tiempo
19.
PLoS One ; 19(6): e0304612, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38870171

RESUMEN

A similarity-driven multi-dimensional binning algorithm (SIMBA) reconstruction of free-running cardiac magnetic resonance imaging data was previously proposed. While very efficient and fast, the original SIMBA focused only on the reconstruction of a single motion-consistent cluster, discarding the remaining data acquired. However, the redundant data clustered by similarity may be exploited to further improve image quality. In this work, we propose a novel compressed sensing (CS) reconstruction that performs an effective regularization over the clustering dimension, thanks to the integration of inter-cluster motion compensation (XD-MC-SIMBA). This reconstruction was applied to free-running ferumoxytol-enhanced datasets from 24 patients with congenital heart disease, and compared to the original SIMBA, the same XD-MC-SIMBA reconstruction but without motion compensation (XD-SIMBA), and a 5D motion-resolved CS reconstruction using the free-running framework (FRF). The resulting images were compared in terms of lung-liver and blood-myocardium sharpness, blood-myocardium contrast ratio, and visible length and sharpness of the coronary arteries. Moreover, an automated image quality score (IQS) was assigned using a pretrained deep neural network. The lung-liver sharpness and blood-myocardium sharpness were significantly higher in XD-MC-SIMBA and FRF. Consistent with these findings, the IQS analysis revealed that image quality for XD-MC-SIMBA was improved in 18 of 24 cases, compared to SIMBA. We successfully tested the hypothesis that multiple motion-consistent SIMBA clusters can be exploited to improve the quality of ferumoxytol-enhanced cardiac MRI when inter-cluster motion-compensation is integrated as part of a CS reconstruction.


Asunto(s)
Algoritmos , Óxido Ferrosoférrico , Cardiopatías Congénitas , Imagen por Resonancia Magnética , Humanos , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Masculino , Femenino , Procesamiento de Imagen Asistido por Computador/métodos , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Movimiento (Física) , Adulto , Niño , Medios de Contraste , Adolescente , Adulto Joven
20.
Magn Reson Med ; 70(6): 1598-607, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23382068

RESUMEN

PURPOSE: Advances in fetal cardiovascular magnetic resonance imaging have been limited by the absence of a reliable cardiac gating signal. The purpose of this work was to develop and validate metric-optimized gating (MOG) for cine imaging of the fetal heart. THEORY AND METHODS: Cine MR and electrocardiogram data were acquired in healthy adult volunteers for validation of the MOG method. Comparison of MOG and electrocardiogram reconstructions was performed based on the image quality for each method, and the difference between MOG and electrocardiogram trigger times. Fetal images were also acquired, their quality evaluated by experienced radiologists, and the theoretical error in the MOG trigger times were calculated. RESULTS: Excellent agreement between electrocardiogram and MOG reconstructions was observed. The experimental errors in adult MOG trigger times for all five volunteers were ± (7, 25, 17, 8, and 13) ms. Fetal images captured normal and diseased cardiac dynamics. CONCLUSION: MOG for cine imaging of the fetal myocardium was developed and validated in adults. Using MOG, the first gated MR images of the human fetal myocardium were obtained. Small moving structures were visualized during radial contraction, thus capturing normal fetal cardiac wall motion and permitting assessment of cardiac function.


Asunto(s)
Algoritmos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Corazón Fetal/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Diagnóstico Prenatal/métodos , Adulto , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad