Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 149(14): 1090-1101, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38344871

RESUMEN

BACKGROUND: Collaboration for the Diagnosis and Evaluation of Acute Coronary Syndrome (CoDE-ACS) is a validated clinical decision support tool that uses machine learning with or without serial cardiac troponin measurements at a flexible time point to calculate the probability of myocardial infarction (MI). How CoDE-ACS performs at different time points for serial measurement and compares with guideline-recommended diagnostic pathways that rely on fixed thresholds and time points is uncertain. METHODS: Patients with possible MI without ST-segment-elevation were enrolled at 12 sites in 5 countries and underwent serial high-sensitivity cardiac troponin I concentration measurement at 0, 1, and 2 hours. Diagnostic performance of the CoDE-ACS model at each time point was determined for index type 1 MI and the effectiveness of previously validated low- and high-probability scores compared with guideline-recommended European Society of Cardiology (ESC) 0/1-hour, ESC 0/2-hour, and High-STEACS (High-Sensitivity Troponin in the Evaluation of Patients With Suspected Acute Coronary Syndrome) pathways. RESULTS: In total, 4105 patients (mean age, 61 years [interquartile range, 50-74]; 32% women) were included, among whom 575 (14%) had type 1 MI. At presentation, CoDE-ACS identified 56% of patients as low probability, with a negative predictive value and sensitivity of 99.7% (95% CI, 99.5%-99.9%) and 99.0% (98.6%-99.2%), ruling out more patients than the ESC 0-hour and High-STEACS (25% and 35%) pathways. Incorporating a second cardiac troponin measurement, CoDE-ACS identified 65% or 68% of patients as low probability at 1 or 2 hours, for an identical negative predictive value of 99.7% (99.5%-99.9%); 19% or 18% as high probability, with a positive predictive value of 64.9% (63.5%-66.4%) and 68.8% (67.3%-70.1%); and 16% or 14% as intermediate probability. In comparison, after serial measurements, the ESC 0/1-hour, ESC 0/2-hour, and High-STEACS pathways identified 49%, 53%, and 71% of patients as low risk, with a negative predictive value of 100% (99.9%-100%), 100% (99.9%-100%), and 99.7% (99.5%-99.8%); and 20%, 19%, or 29% as high risk, with a positive predictive value of 61.5% (60.0%-63.0%), 65.8% (64.3%-67.2%), and 48.3% (46.8%-49.8%), resulting in 31%, 28%, or 0%, who require further observation in the emergency department, respectively. CONCLUSIONS: CoDE-ACS performs consistently irrespective of the timing of serial cardiac troponin measurement, identifying more patients as low probability with comparable performance to guideline-recommended pathways for MI. Whether care guided by probabilities can improve the early diagnosis of MI requires prospective evaluation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00470587.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Femenino , Persona de Mediana Edad , Masculino , Síndrome Coronario Agudo/diagnóstico , Biomarcadores , Infarto del Miocardio/diagnóstico , Troponina , Aprendizaje Automático , Troponina T
2.
Circulation ; 144(10): 773-787, 2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-34376064

RESUMEN

BACKGROUND: The non-ST-segment-elevation myocardial infarction (NSTEMI) guidelines of the European Society of Cardiology (ESC) recommend a 3h cardiac troponin determination in patients triaged to the observe-zone of the ESC 0/1h-algorithm; however, no specific cutoff for further triage is endorsed. Recently, a specific cutoff for 0/3h high-sensitivity cardiac troponin T (hs-cTnT) change (7 ng/L) was proposed, warranting external validation. METHODS: Patients presenting with acute chest discomfort to the emergency department were prospectively enrolled into an international multicenter diagnostic study. Final diagnoses were centrally adjudicated by 2 independent cardiologists applying the fourth universal definition of myocardial infarction, on the basis of complete cardiac workup, cardiac imaging, and serial hs-cTnT. Hs-cTnT concentrations were measured at presentation, after 1 hour, and after 3 hours. The objective was to externally validate the proposed cutoff, and if necessary, derive and internally as well as externally validate novel 0/3h-criteria for the observe-zone of the ESC 0/1h-hs-cTnT-algorithm in an independent multicenter cohort. RESULTS: Among 2076 eligible patients, application of the ESC 0/1h-hs-cTnT-algorithm triaged 1512 patients (72.8%) to either rule out or rule in NSTEMI, leaving 564 patients (27.2%) in the observe-zone (adjudicated NSTEMI prevalence, 120/564 patients, 21.3%). The suggested 0/3h-hs-cTnT-change of <7 ng/L triaged 517 patients (91.7%) toward rule-out, resulting in a sensitivity of 33.3% (95% CI, 25.5-42.2), missing 80 patients with NSTEMI, and ≥7 ng/L triaged 47 patients toward rule-in (8.3%), resulting in a specificity of 98.4% (95% CI, 96.8-99.2). Novel derived 0/3h-criteria for the observe-zone patients ruled out NSTEMI with a 3h hs-cTnT concentration <15 ng/L and a 0/3h-hs-cTnT absolute change <4 ng/L, triaging 138 patients (25%) toward rule-out, resulting in a sensitivity of 99.2% (95% CI, 96.0-99.9), missing 1 patient with NSTEMI. A 0/3h-hs-cTnT absolute change ≥6 ng/L triaged 63 patients (11.2%) toward rule-in, resulting in a specificity of 98% (95% CI, 96.2-98.9) Thereby, the novel 0/3h-criteria reduced the number of patients in the observe zone by 36%s and the number of type 1 myocardial infarction by 50%. Findings were confirmed in both internal and external validation. CONCLUSIONS: A combination of a 3h-hs-cTnT concentration (<15 ng/L) and a 0/3h absolute change (<4 ng/L) is necessary to safely rule out NSTEMI in patients remaining in the observe-zone of the ESC 0/1h-hs-cTnT-algorithm. Registration: URL: https://clinicaltrials.gov; Unique identifier: NCT00470587.


Asunto(s)
Algoritmos , Sistema Cardiovascular/fisiopatología , Infarto del Miocardio/terapia , Infarto del Miocardio con Elevación del ST/terapia , Técnicas de Imagen Cardíaca/métodos , Cardiología/métodos , Recolección de Datos , Pruebas Diagnósticas de Rutina/efectos adversos , Corazón/fisiopatología , Humanos , Infarto del Miocardio/fisiopatología
3.
Herz ; 47(4): 381-392, 2022 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-35699750

RESUMEN

The collective term acute coronary syndrome (ACS) encompasses ST-segment elevation myocardial infarction (STEMI) and non-ST-segment elevation ACS (NSTE-ACS). The latter comprises unstable angina pectoris and non-ST-segment elevation myocardial infarction (NSTEMI). The diagnosis of STEMI necessitates an immediate referral to cardiac catheterization. The diagnostics and management of NSTE-ACS are more challenging. The current guidelines of the European Society of Cardiology (ESC) for treatment of NSTE-ACS were published in 2020 and deal with the topics of diagnostics, risk stratification, antithrombotic treatment, invasive or non-invasive coronary diagnostics and long-term treatment. The focus of the guidelines is on the application of high-sensitivity cardiac troponin assay(hs-cTn) combined with verified diagnostic algorithms to enable a rapid triage decision (rule-in as possible NSTEMI or rule-out as NSTEMI excluded) in the emergency room or the chest pain unit.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio sin Elevación del ST , Infarto del Miocardio con Elevación del ST , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Angina Inestable , Dolor en el Pecho/diagnóstico , Humanos , Infarto del Miocardio sin Elevación del ST/diagnóstico , Infarto del Miocardio sin Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/terapia
4.
Circulation ; 137(5): 436-451, 2018 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-29101287

RESUMEN

BACKGROUND: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non-ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. METHODS: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non-ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m2, and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. RESULTS: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non-ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P<0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6-100.0] versus 99.2% [95% CI, 97.6-99.8]; P=0.559), lower specificity of rule-in (88.7% [95% CI, 84.8-91.9] versus 96.5% [95% CI, 95.7-97.2]; P<0.001), and lower overall efficacy (51% versus 81%, P<0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P<0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0-99.8] versus 98.5% [95% CI, 96.5-99.5]; P=1.0), lower specificity of rule-in (84.4% [95% CI, 79.9-88.3] versus 91.7% [95% CI, 90.5-92.9]; P<0.001), and lower overall efficacy (54% versus 76%, P<0.001; proportion ruled out, 18% versus 58%, P<0.001) compared with patients with normal renal function. CONCLUSIONS: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00470587.


Asunto(s)
Algoritmos , Técnicas de Apoyo para la Decisión , Tasa de Filtración Glomerular , Enfermedades Renales/fisiopatología , Riñón/fisiopatología , Infarto del Miocardio sin Elevación del ST/sangre , Infarto del Miocardio sin Elevación del ST/diagnóstico , Triaje , Troponina/sangre , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Creatinina/sangre , Europa (Continente)/epidemiología , Femenino , Humanos , Enfermedades Renales/sangre , Enfermedades Renales/diagnóstico , Enfermedades Renales/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/epidemiología , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico , Estudios Prospectivos , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Regulación hacia Arriba
5.
Circulation ; 138(10): 989-999, 2018 09 04.
Artículo en Inglés | MEDLINE | ID: mdl-29691270

RESUMEN

BACKGROUND: Combining 2 signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high-sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of acute myocardial infarction. METHODS: The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio, and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected acute myocardial infarction. The optimal rule-out and rule-in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule-out was compared with the European Society of Cardiology 0/1 and 0/3 hour algorithms. RESULTS: Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the European Society of Cardiology 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule-out criteria after the baseline blood sampling was limited (6% to 24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng2/L2) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34% to 41% in the original (sum: negative predictive value [NPV] 100% [95% confidence interval (CI), 99.5% to 100%]; product: NPV 100% [95% CI, 99.5% to 100%]) and in the validation cohort (sum: NPV 99.6% [95% CI, 99.0-99.9%]; product: NPV 99.4% [95% CI, 98.8-99.8%]). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule-out (40% to 43% ruled out; NPV original cohort 99.9% [95% CI, 99.2-100%]; NPV validation cohort 99.5% [95% CI, 98.9-99.8%]) and rule-in (positive predictive value [PPV] original cohort 74.4% [95% Cl, 69.6-78.8%]; PPV validation cohort 84.0% [95% Cl, 79.7-87.6%]). CONCLUSIONS: New strategies combining hs-cTnI and hs-cTnT concentrations may significantly increase the number of patients eligible for very early and safe rule-out, but do not seem helpful for the rule-in of acute myocardial infarction. CLINICAL TRIAL REGISTRATION: URL (APACE): https://www.clinicaltrial.gov . Unique identifier: NCT00470587. URL (ADAPT): www.anzctr.org.au . Unique identifier: ACTRN12611001069943.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/sangre , Troponina T/sangre , Australia , Biomarcadores/sangre , Diagnóstico Precoz , Europa (Continente) , Humanos , Infarto del Miocardio/sangre , Nueva Zelanda , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo , Regulación hacia Arriba
6.
Clin Chem ; 65(11): 1426-1436, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31570633

RESUMEN

BACKGROUND: We aimed to validate the clinical performance of the high-sensitivity cardiac troponin I [VITROS® Immunodiagnostic Products hs Troponin I (hs-cTnI-VITROS)] assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists considering all clinical information, including cardiac imaging: first, using serial hs-cTnT-Elecsys (primary analysis) and, second, using hs-cTnI-Architect (secondary analysis) measurements in addition to the clinically used (hs)-cTn. hs-cTnI-VITROS was measured at presentation and at 1 h in a blinded fashion. The primary objective was direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI-VITROS vs hs-cTnT-Elecsys and hs-cTnI-Architect, and in a subgroup also hs-cTnI-Centaur and hs-cTnI-Access. Secondary objectives included the derivation and validation of an hs-cTnI-VITROS-0/1-h algorithm. RESULTS: AMI was the adjudicated final diagnosis in 158 of 1231 (13%) patients. At presentation, the AUC for hs-cTnI-VITROS was 0.95 (95% CI, 0.93-0.96); for hs-cTnT-Elecsys, 0.94 (95% CI, 0.92-0.95); and for hs-cTnI-Architect, 0.92 (95% CI, 0.90-0.94). AUCs for hs-cTnI-Centaur and hs-cTnI-Access were 0.95 (95% CI, 0.94-0.97). Applying the derived hs-cTnI-VITROS-0/1-h algorithm (derivation cohort n = 519) to the validation cohort (n = 520), 53% of patients were ruled out [sensitivity, 100% (95% CI, 94.1-100)] and 14% of patients were ruled in [specificity, 95.6% (95% CI, 93.4-97.2)]. Patients ruled out by the 0/1-h algorithm had a survival rate of 99.8% at 30 days. Findings were confirmed in the secondary analyses using the adjudication including serial measurements of hs-cTnI-Architect. CONCLUSIONS: The hs-cTnI-VITROS assay has at least comparable diagnostic accuracy with the currently best validated hs-cTnT and hs-cTnI assays. CLINICALTRIALSGOV IDENTIFIER: NCT00470587.


Asunto(s)
Bioensayo/métodos , Infarto del Miocardio/diagnóstico , Troponina I/sangre , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Biomarcadores/sangre , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Estudios Prospectivos , Curva ROC
7.
Clin Chem ; 65(7): 893-904, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30988172

RESUMEN

BACKGROUND: The aim of this study was to validate the clinical performance of the Beckman Access high-sensitivity cardiac troponin I (hs-cTnI) assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists with all clinical information including cardiac imaging twice: first, using serial hs-cTnT (Elecsys, primary analysis), and second, using hs-cTnI (Architect, secondary analysis) measurements in addition to the clinically used hs-cTn. hs-cTnI Access was measured at presentation and at 1 h. The primary objective was a direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI Access vs the hs-cTnT Elecsys and hs-cTnI Architect assays. Secondary objectives included the derivation and validation of an hs-cTnI Access-specific 0/1-h algorithm. RESULTS: AMI was the adjudicated final diagnosis in 243 of 1579 (15.4%) patients. The AUC at presentation for hs-cTnI Access was 0.95 (95% CI, 0.94-0.96), higher than hs-cTnI Architect [0.92 (95% CI, 0.91-0.94; P < 0.001)] and comparable to hs-cTnT Elecsys [0.94 (95% CI, 0.93-0.95; P = 0.12)]. Applying the derived hs-cTnI Access 0/1-h algorithm (derivation cohort n = 686) to the validation cohort (n = 680), 60% of patients were ruled out [sensitivity, 98.9% (95% CI, 94.3-99.8)], and 15% of patients were ruled in [specificity, 95.9% (95% CI, 94.0-97.2)]. Patients ruled out by the 0/1-h algorithm had a survival rate of 100% at 30 days. Findings were confirmed in the secondary analyses by the adjudication including serial measurements of Architect hs-cTnI. CONCLUSIONS: Diagnostic accuracy and clinical utility of the Beckman hs-cTnI Access assay are very high and at least comparable to Roche hs-cTnT and Abbott hs-cTnI assays. ClinicalTrials.gov Identifier: NCT00470587.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/sangre , Anciano , Anciano de 80 o más Años , Algoritmos , Área Bajo la Curva , Biomarcadores/sangre , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Estudios Prospectivos , Curva ROC , Troponina T/sangre
8.
Clin Chem ; 65(8): 1006-1014, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31118187

RESUMEN

OBJECTIVES: We sought to evaluate diagnostic accuracy of a high-sensitivity cardiac troponin I (hs-cTnI) assay for acute coronary syndromes (ACS) in the emergency department (ED). The assay has high precision at low concentrations and can detect cTnI in 96.8% of healthy individuals. METHODS: In successive prospective multicenter studies ("testing" and "validation"), we included ED patients with suspected ACS. We drew blood for hs-cTnI [Singulex Clarity® cTnI; 99th percentile, 8.67 ng/L; limit of detection (LoD), 0.08 ng/L] on arrival. Patients also underwent hs-cTnT (Roche Elecsys) testing over ≥3 h. The primary outcome was an adjudicated diagnosis of ACS, defined as acute myocardial infarction (AMI; prevalent or incident), death, or revascularization within 30 days. RESULTS: The testing and validation studies included 665 and 2470 patients, respectively, of which 94 (14.1%) and 565 (22.9%) had ACS. At a 1.5-ng/L cutoff, hs-cTnI had good sensitivity for AMI in both studies (98.7% and 98.1%, respectively) and would have "ruled out" 40.1% and 48.9% patients. However, sensitivity was lower for ACS (95.7% and 90.6%, respectively). At a 0.8-ng/L cutoff, sensitivity for ACS was higher (97.5% and 97.9%, ruling out 28.6% patients in each cohort). The hs-cTnT assay had similar performance at the LoD (24.6% ruled out; 97.2% sensitivity for ACS). CONCLUSIONS: The hs-cTnI assay could immediately rule out AMI in 40% of patients and ACS in >25%, with similar accuracy to hs-cTnT at the LoD. Because of its high precision at low concentrations, this hs-cTnI assay has favorable characteristics for this clinical application.


Asunto(s)
Infarto del Miocardio/sangre , Troponina I/sangre , Troponina T/sangre , Anciano , Servicio de Urgencia en Hospital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Clin Chem ; 65(3): 437-450, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30626633

RESUMEN

BACKGROUND: We desired to determine cardiac troponin (cTn) concentrations necessary to achieve a positive predictive value (PPV) of ≥75% for acute myocardial infarction (AMI) to justify immediate admission of patients to a monitored unit and, in general, early coronary angiography. METHODS: In a prospective multicenter diagnostic study enrolling patients presenting to the emergency department with symptoms suggestive of AMI, final diagnoses were adjudicated by 2 independent cardiologists based on clinical information including cardiac imaging. cTn concentrations were measured using 5 different sensitive and high-sensitivity cTn (hs-cTn) assays in a blinded fashion at presentation and serially thereafter. The diagnostic end point was PPV for rule-in of AMI of initial cTn concentrations alone and in combination with early changes. RESULTS: Among 3828 patients, 616 (16%) had an AMI. At presentation, 7% to 14% of patients had cTnT/I concentrations associated with a PPV of ≥75%. Adding absolute or relative changes did not significantly further increase the PPV. PPVs increased from 46.5% (95% CI, 43.6-49.4) for hs-cTnT at presentation >14 ng/L to 78.9% (95% CI, 74.7-82.5) for >52 ng/L (P < 0.001), whereas PPVs in higher hs-cTnT strata remained largely unchanged [e.g., 82.4% (95% CI, 77.5-86.7) for >80 ng/L vs 83.9% (95% CI, 76.0-90.1) for >200 ng/L (P = 0.72)]. The addition of early changes in hs-cTnT further increased the PPV up to 60 ng/L, but not for higher concentrations. CONCLUSIONS: Serial sampling does not seem necessary for predicting AMI and concurrent decision-making in about 10% of patients, as it only marginally increases the PPV for AMI and not in a statistically or clinically significant way. CLINICALTRIALSGOV IDENTIFIER: NCT00470587.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/sangre , Troponina T/sangre , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Análisis Químico de la Sangre/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos
11.
Eur Heart J ; 39(42): 3780-3794, 2018 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-30169752

RESUMEN

Aims: We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. Methods and results: We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), ≥55 to <70 years (middle-age), ≥70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.5-99.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P < 0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P < 0.01), reduced overall efficacy for hs-cTnT (P < 0.01), while maintaining efficacy for hs-cTnI. Findings were confirmed in two validation cohorts (n = 2767). Conclusion: While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnI. Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587 and NCT02355457 (BACC).


Asunto(s)
Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Adulto , Factores de Edad , Anciano , Algoritmos , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Estudios Prospectivos , Sensibilidad y Especificidad , Troponina/sangre
12.
Clin Chem ; 64(3): 515-525, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29343534

RESUMEN

BACKGROUND: There is concern that high-sensitivity cardiac troponin (hs-cTn) may have low diagnostic accuracy in patients with low acute coronary syndrome (ACS) probability. METHODS: We prospectively stratified patients presenting with acute chest discomfort to the emergency department (ED) into 3 groups according to their probability for ACS as assessed by the treating ED physician using a visual analog scale: ≤10%, 11% to 79%, and ≥80%, reviewing all information available at 90 min. hs-cTnT and hs-cTnI concentrations were determined in a blinded fashion. Two independent cardiologists adjudicated the final diagnosis. RESULTS: Among 3828 patients eligible for analysis, 1189 patients had low (≤10%) probability for ACS. The incidence of non-ST-segment elevation myocardial infarction (NSTEMI) increased from 1.3% to 12.2% and 54.8% in patients with low, intermediate, and high ACS probability, respectively. The positive predictive value of hs-cTnT and hs-cTnI was low in patients with low ACS probability and increased with the incidence of NSTEMI, whereas the diagnostic accuracy of hs-cTnT and hs-cTnI for NSTEMI as quantified by the area under the curve (AUC) was very high and comparable among all 3 strata, e.g., AUC hs-cTnI, 0.96 (95% CI, 0.94-0.97); 0.87 (95% CI, 0.85-0.89); and 0.89 (95% CI, 0.87-0.92), respectively. Findings were validated using bootstrap analysis as an alternative methodology to define ACS probability. Similarly, higher hs-cTnT/I concentrations independently predicted all-cause mortality within 2 years (e.g., hs-cTnT hazard ratio, 1.39; 95% CI, 1.27-1.52), irrespective of ACS probability. CONCLUSIONS: Diagnostic and prognostic accuracy and utility of hs-cTnT and hs-cTnI remain high in patients with acute chest discomfort and low ACS probability.ClinicalTrials.gov Identifier: NCT00470587.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Troponina I/sangre , Troponina T/sangre , Síndrome Coronario Agudo/sangre , Adulto , Anciano , Biomarcadores/sangre , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Probabilidad , Sensibilidad y Especificidad
13.
Clin Chem ; 64(9): 1347-1360, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29941469

RESUMEN

BACKGROUND: Clinical performance of the novel high-sensitivity cardiac troponin I (Siemens-hs-cTnI-Centaur) assay is unknown. We aimed to clinically validate the Siemens-hs-cTnI-Centaur assay and develop 0/1-h and 0/2-h algorithms. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists including all clinical information twice: first, using serial hs-cTnT (Roche-Elecsys, primary analysis); second, using hs-cTnI (Abbott-Architect, secondary analysis) measurements in addition to the clinically applied (hs)-cTn. Siemens-hs-cTnI-Centaur was measured at presentation, 1 h, and 2 h. The primary objective was a direct comparison of diagnostic accuracy, quantified by the area under the ROC curve (AUC), of Siemens-hs-cTnI-Centaur vs the 2 established hs-cTn assays (Roche-hs-cTnT-Elecsys, Abbott-hs-cTnI-Architect). Secondary objectives included the development of Siemens-hs-cTnI-Centaur-specific 0/1-h and 0/2-h algorithms. RESULTS: AMI was the final diagnosis in 318 of 1755 (18%) patients (using Roche-hs-cTnT-Elecsys for adjudication). The AUC at presentation for Siemens-hs-cTnI-Centaur was 0.94 (95% CI, 0.92-0.96) and comparable with 0.95 (95% CI, 0.93-0.97) for Roche-hs-cTnT-Elecsys and 0.93 (95% CI, 0.90-0.96) for Abbott-hs-cTnI-Architect. Applying the derived Siemens-hs-cTnI-Centaur 0/1-h algorithm to the validation cohort, 46% of patients were ruled out (sensitivity, 99.1%; 95% CI, 95.3-100), and 18% of patients were ruled in (specificity, 94.1%; 95% CI, 91.8-95.9). The Siemens-hs-cTnI-Centaur 0/2-h algorithm ruled out 55% of patients (sensitivity, 100%; 95% CI, 94.1-100), and ruled in 18% of patients (specificity, 96.0%; 95% CI, 93.1-97.9). Findings were confirmed in the secondary analyses using serial measurements of Abbott-hs-cTnI-Architect for adjudication. CONCLUSIONS: Diagnostic accuracy and clinical utility of the novel Siemens-hs-cTnI-Centaur assay are high and comparable with the established hs-cTn assays. ClinicalTrials.gov Identifier: NCT00470587.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/sangre , Algoritmos , Dolor en el Pecho , Diagnóstico Precoz , Electrocardiografía , Femenino , Humanos , Masculino , Infarto del Miocardio/fisiopatología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Ann Noninvasive Electrocardiol ; 23(4): e12538, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29476571

RESUMEN

BACKGROUND: The cardiac electrical biomarker (CEB) is a novel electrocardiographic (ECG) marker quantifying the dipolar activity of the heart with higher levels indicating myocardial injury. METHODS: We prospectively enrolled 1097 patients presenting with suspected non-ST-elevation myocardial infarction (NSTEMI) to the emergency department (ED). Digital 12-lead ECGs were recorded at presentation and the CEB values were calculated in a blinded fashion. The final diagnosis was adjudicated by two independent cardiologists. The prognostic endpoint was all-cause mortality during 2 years of follow-up. RESULTS: NSTEMI was the final diagnosis in 14% of patients. CEB levels were higher in patients with NSTEMI compared to other causes of chest pain (median 44 (IQR 21-98) vs. 30 (IQR 16-61), p < .001). A weak but significant correlation between levels of high-sensitivity cardiac troponin T (hs-cTnT) at admission to the ED and the CEB was found (r = .23, p < .001). The use of the CEB in addition to conventional ECG criteria improved the diagnostic accuracy for the diagnosis of NSTEMI as quantified by the area under the receiver operating characteristics curve from 0.66 to 0.71 (p < .001) and the sensitivity improved from 43% to 79% (p < .001). CONCLUSION: In conclusion, the CEB, an ECG marker of myocardial injury, significantly improves the accuracy and sensitivity of the ECG for the diagnosis of NSTEMI.


Asunto(s)
Electrocardiografía/métodos , Infarto del Miocardio sin Elevación del ST/diagnóstico , Infarto del Miocardio sin Elevación del ST/fisiopatología , Adulto , Anciano , Biomarcadores , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Clin Chem ; 63(7): 1227-1236, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28515106

RESUMEN

BACKGROUND: We compared 2 high-sensitivity cardiac troponin (hs-cTn)-based 2-h strategies in patients presenting with suspected acute myocardial infarction (AMI) to the emergency department (ED): the 2-h accelerated diagnostic protocol (2h-ADP) combining hs-cTn, electrocardiogram, and a risk score, and the 2-h algorithm exclusively based on hs-cTn concentrations and their absolute changes. METHODS: Analyses were performed in 2 independent diagnostic cohorts [European Advantageous Predictors of Acute Coronary Syndrome Evaluation (APACE) study, Australian-New Zealand 2-h Accelerated Diagnostic Protocol to Assess patients with chest Pain symptoms using contemporary Troponins as the only biomarker (ADAPT) study] employing hs-cTnT (Elecsys) and hs-cTnI (Architect). The final diagnosis was adjudicated by 2 independent cardiologists. RESULTS: AMI was the final diagnosis in 16.5% (95% CI, 14.6%-18.6%) of the 1372 patients in APACE, and 12.6% (95% CI, 10.7%-14.7%) of 1153 patients in ADAPT. The negative predictive value (NPV) and sensitivity for AMI were very high and comparable with both strategies using either hs-cTnT or hs-cTnI in both cohorts (all statistical comparisons nonsignificant). The percentage of patients triaged toward rule-out was significantly lower with the 2h-ADP (36%-43%) vs the 2-h algorithm (55%-68%) with both assays and in both cohorts (P < 0.001). The sensitivity of the 2h-ADP was higher for 30-day major adverse cardiovascular events. CONCLUSIONS: Both algorithms provided very high and comparable safety as quantified by the NPV and sensitivity for AMI and major adverse cardiac events (MACE) at 30 days in patients triaged toward rule-out, although sensitivity for MACE at 30 days was lower with both algorithms in cohort 2. Although the 2-h algorithm was more efficacious, not all patients ruled out for AMI by this algorithm were appropriate candidates for early discharge. The 2h-ADP seems superior in the selection of patients for early discharge from the ED. CLINICAL TRIAL REGISTRATION: APACE: http://clinicaltrials.gov/show/NCT00470587ADAPT: Australia-New Zealand Clinical Trials Registry ACTRN12611001069943.


Asunto(s)
Algoritmos , Técnicas de Diagnóstico Cardiovascular/normas , Infarto del Miocardio/diagnóstico , Anciano , Femenino , Humanos , Masculino , Infarto del Miocardio/sangre , Estudios Prospectivos , Troponina I/sangre , Troponina T/sangre
16.
Eur Heart J ; 37(44): 3324-3332, 2016 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-27357358

RESUMEN

AIMS: High-sensitivity cardiac troponin (hs-cTn) assays provide higher diagnostic accuracy for acute myocardial infarction (AMI) when compared with conventional assays, but may result in increased use of unnecessary coronary angiographies due to their increased detection of cardiomyocyte injury in conditions other than AMI. METHODS AND RESULTS: We evaluated the impact of the clinical introduction of high-sensitivity cardiac troponin T (hs-cTnT) on the use of coronary angiography, stress testing, and time to discharge in 2544 patients presenting with symptoms suggestive of AMI to the emergency department (ED) within a multicentre study either before (1455 patients) or after (1089 patients) hs-cTnT introduction. Acute myocardial infarction was more often the clinical discharge diagnosis after hs-cTnT introduction (10 vs. 14%, P < 0.001), while unstable angina less often the clinical discharge diagnosis (14 vs. 9%, P = 0.007). The rate of coronary angiography was similar before and after the introduction of hs-cTnT (23 vs. 23%, P = 0.092), as was the percentage of coronary angiographies showing no stenosis (11 vs. 7%, P = 0.361). In contrast, the use of stress testing was substantially reduced from 29 to 19% (P < 0.001). In outpatients, median time to discharge from the ED decreased by 79 min (P < 0.001). Mean total costs decreased by 20% in outpatients after the introduction of hs-cTnT (P = 0.002). CONCLUSION: The clinical introduction of hs-cTn does not lead to an increased or inappropriate use of coronary angiography. Introduction of hs-cTn is associated with an improved rule-out process and thereby reduces the need for stress testing and time to discharge. CLINICAL TRIAL REGISTRATION INFORMATION: www.clinicaltrials.gov. Identifier, NCT00470587.


Asunto(s)
Angiografía Coronaria , Infarto del Miocardio , Biomarcadores , Humanos , Estudios Prospectivos , Troponina
18.
Am Heart J ; 181: 16-25, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27823689

RESUMEN

BACKGROUND: The early and accurate diagnosis of acute myocardial infarction (AMI) is an important medical and economic challenge. We aimed to prospectively evaluate the performance of the new European Society of Cardiology rapid 0-hour/3-hour (0 h/3 h) rule out protocol for AMI. METHODS: We enrolled 2,727 consecutive patients presenting with suspected AMI without persistent ST-segment elevation to the emergency department in a prospective international multicenter study. The final diagnosis was adjudicated by 2 independent cardiologists. The performance of the 0 h/3 h rule out protocol was evaluated using 4 high-sensitivity (primary analysis) and 3 sensitive cardiac troponin (cTn) assays. RESULTS: Acute myocardial infarction was the final diagnosis in 473 patients (17.3%). Using the 4 high-sensitivity cTn assays, the 0-hour rule out protocol correctly ruled out 99.8% (95% [confidence interval] CI, 98.7%-100%), 99.6% (95% CI, 98.5%-99.9%), 100% (95% CI, 97.9%-100%), and 100% (95% CI, 98.0%-100%) of late presenters (>6 h from chest pain onset). The 3-hour rule out protocol correctly ruled out 99.9% (95% CI, 99.1%-100%), 99.5% (95% CI, 98.3%-99.9%), 100% (95% CI, 98.1%-100%), and 100% (95% CI, 98.2%-100%) of early presenters (<6 h from chest pain onset). Using the 3 sensitive cTn assays, the 0-hour rule out protocol correctly ruled out 99.6% (95% CI, 98.6%-99.9%), 99.0% (95% CI, 96.9%-99.7%), and 99.1% (95% CI, 97.2%-99.8%) of late presenters; and the 3-hour rule out protocol correctly ruled out 99.4% (95% CI, 98.3%-99.8%), 99.2% (95% CI, 97.3%-99.8%), and 99.0% (95% CI, 97.2%-99.7%) of early presenters. Overall, the 0 h/3 h rule out protocol assigned 40% to 60% of patients to rule out. None of the patients assigned rule out died during 3-months follow-up. CONCLUSIONS: The 0 h/3 h rule out protocol seems to allow the accurate rule out of AMI using both high-sensitivity and sensitive cTn measurements in conjunction with clinical assessment. Additional studies are warranted for external validation.


Asunto(s)
Dolor en el Pecho/diagnóstico , Infarto del Miocardio/diagnóstico , Troponina I/sangre , Troponina T/sangre , Anciano , Anciano de 80 o más Años , Dolor en el Pecho/sangre , Dolor en el Pecho/etiología , Protocolos Clínicos , Electrocardiografía , Servicio de Urgencia en Hospital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/complicaciones , Estudios Prospectivos , Factores de Tiempo
19.
Am Heart J ; 173: 8-17, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26920591

RESUMEN

BACKGROUND: A pilot study using a novel high-sensitivity cardiac troponin I (hs-cTnI) assay suggested that cTnI might be released into blood during exercise-induced myocardial ischemia. We investigated the potential clinical value of this signal. METHODS: We included 819 patients with suspected exercise-induced myocardial ischemia referred for rest/bicycle myocardial perfusion single-photon emission computed tomography. The treating cardiologist used all available clinical information to quantify clinical judgment regarding the presence of myocardial ischemia using a visual analog scale twice: prior and after stress testing. High-sensitivity cTnI measurements were obtained before, immediately after peak stress, and 2 hours after stress testing in a blinded manner. Myocardial ischemia was adjudicated using perfusion single-photon emission computed tomography and coronary angiography findings. RESULTS: Exercise-induced myocardial ischemia was detected in 278 (34%) patients. High-sensitivity cTnI levels were significantly higher at all time points in patients with myocardial ischemia as compared with those without (P < .001 for all). Combining clinical judgment prior exercise testing with baseline hs-cTnI levels increased diagnostic accuracy as quantified by the area under the receiver operating characteristics curve (AUC) from 0.672 to 0.757 (P < .001). Combining clinical judgment after exercise testing (AUC 0.704) with baseline or poststress hs-cTnI levels also increased the diagnostic accuracy (AUC 0.761-0.771, P < .001 for all). In contrast, exercise-induced changes in hs-cTnI during exercise did not seem useful, as they were small and similar in patients with or without myocardial ischemia. CONCLUSIONS: High-sensitivity cTnI concentrations at rest and after exercise, but not its exercise-induced changes, provide substantial incremental value to clinical judgment including exercise electrocardiography regarding the presence of myocardial ischemia.


Asunto(s)
Prueba de Esfuerzo/efectos adversos , Ejercicio Físico , Isquemia Miocárdica/sangre , Miocardio/metabolismo , Troponina I/sangre , Anciano , Biomarcadores/sangre , Angiografía Coronaria , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/etiología , Proyectos Piloto , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada de Emisión de Fotón Único
20.
Am Heart J ; 171(1): 92-102.e1-5, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26699605

RESUMEN

UNLABELLED: We aimed to prospectively derive and validate a novel 0-/1-hour algorithm using high-sensitivity cardiac troponin I (hs-cTnI) for the early "rule-out" and "rule-in" of acute myocardial infarction (AMI). METHODS: In a prospective multicenter diagnostic study, we enrolled 1,500 patients presenting with suspected AMI to the emergency department. The final diagnosis was centrally adjudicated by 2 independent cardiologists blinded to hs-cTnI concentrations. The hs-cTnI (Siemens Vista) 0-/1-hour algorithm incorporated measurements performed at baseline and absolute changes within 1 hour, was derived in the first 750 patients (derivation cohort), and then validated in the second 750 (validation cohort). RESULTS: Overall, AMI was the final diagnosis in 16% of patients. Applying the hs-cTnI 0-/1-hour algorithm developed in the derivation cohort to the validation cohort, 57% of patients could be classified as "rule-out"; 10%, as "rule-in"; and 33%, as "observe." In the validation cohort, the sensitivity and the negative predictive value for AMI in the "rule-out" zone were 100% (95% CI 96%-100%) and 100% (95% CI 99%-100%), respectively. The specificity and the positive predictive value (PPV) for AMI in the "rule-in" zone were 96% (95% CI 94%-97%) and 70% (95% CI 60%-79%), respectively. Negative predictive value and positive predictive value of the 0-/1-hour algorithm were higher compared to the standard of care combining hs-cTnI with the electrocardiogram (both P < .001). CONCLUSION: The hs-cTnI 0-/1-hour algorithm performs very well for early rule-out as well as rule-in of AMI. The clinical implications are that used in conjunction with all other clinical information, the 0-/1-hour algorithm will be a safe and effective approach to substantially reduce time to diagnosis.


Asunto(s)
Algoritmos , Electrocardiografía , Infarto del Miocardio/diagnóstico , Troponina I/sangre , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA