Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
HPB (Oxford) ; 26(1): 34-43, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37777384

RESUMEN

BACKGROUND: In colorectal liver metastases (CRLM) patients, combination of liver resection and ablation permit a more parenchymal-sparing approach. This study assessed trends in use of combined resection and ablation, outcomes, and overall survival (OS). METHODS: This population-based study included all CRLM patients who underwent liver resection between 2014 and 2022. To assess OS, data was linked to two databases containing date of death for patients treated between 2014 and 2018. Hospital variation in the use of combined minor liver resection and ablation versus major liver resection alone in patients with 2-3 CRLM and ≤3 cm was assessed. Propensity score matching (PSM) was applied to evaluate outcomes. RESULTS: This study included 3593 patients, of whom 1336 (37.2%) underwent combined resection and ablation. Combined resection increased from 31.7% in 2014 to 47.9% in 2022. Significant hospital variation (range 5.9-53.8%) was observed in the use of combined minor liver resection and ablation. PSM resulted in 1005 patients in each group. Major morbidity was not different (11.6% vs. 5%, P = 1.00). Liver failure occurred less often after combined resection and ablation (1.9% vs. 0.6%, P = 0.017). Five-year OS rates were not different (39.3% vs. 33.9%, P = 0.145). CONCLUSION: Combined resection and ablation should be available and considered as an alternative to resection alone in any patient with multiple metastases.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Humanos , Neoplasias Colorrectales/patología , Puntaje de Propensión , Estudios Retrospectivos , Neoplasias Hepáticas/secundario , Hepatectomía/efectos adversos , Hepatectomía/métodos , Resultado del Tratamiento
2.
BMC Cancer ; 23(1): 771, 2023 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-37596578

RESUMEN

BACKGROUND: High dose unilobar radioembolization (also termed 'radiation lobectomy')-the transarterial unilobar infusion of radioactive microspheres as a means of controlling tumour growth while concomitantly inducing future liver remnant hypertrophy-has recently gained interest as induction strategy for surgical resection. Prospective studies on the safety and efficacy of the unilobar radioembolization-surgery treatment algorithm are lacking. The RALLY study aims to assess the safety and toxicity profile of holmium-166 unilobar radioembolization in patients with hepatocellular carcinoma ineligible for surgery due to insufficiency of the future liver remnant. METHODS: The RALLY study is a multicenter, interventional, non-randomized, open-label, non-comparative safety study. Patients with hepatocellular carcinoma who are considered ineligible for surgery due to insufficiency of the future liver remnant (< 2.7%/min/m2 on hepatobiliary iminodiacetic acid scan will be included. A classical 3 + 3 dose escalation model will be used, enrolling three to six patients in each cohort. The primary objective is to determine the maximum tolerated treated non-tumourous liver-absorbed dose (cohorts of 50, 60, 70 and 80 Gy). Secondary objectives are to evaluate dose-response relationships, to establish the safety and feasibility of surgical resection following unilobar radioembolization, to assess quality of life, and to generate a biobank. DISCUSSION: This will be the first clinical study to assess the unilobar radioembolization-surgery treatment algorithm and may serve as a stepping stone towards its implementation in routine clinical practice. TRIAL REGISTRATION: Netherlands Trial Register NL8902 , registered on 2020-09-15.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/radioterapia , Microesferas , Estudios Prospectivos , Calidad de Vida , Neoplasias Hepáticas/radioterapia , Hepatomegalia , Estudios Multicéntricos como Asunto
3.
Eur Radiol ; 32(6): 4168-4176, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35133486

RESUMEN

OBJECTIVES: Thermal ablation (TA) is an established treatment for early HCC. There is a lack of data on the efficacy of repeated TA for recurrent HCC, resulting in uncertainty whether good oncologic outcomes can be obtained without performing orthotopic liver transplantation (OLTx). This study analyses outcomes after TA, with a special focus on repeat TA for recurrent HCC, either as a stand-alone therapy, or in relationship with OLTx. METHODS: Data from a prospectively registered database on interventions for HCC in a tertiary hepatobiliary centre was completed with follow-up until December 2020. Outcomes studied were rate of recurrence after primary TA and after its repeat interventions, the occurrence of untreatable recurrence, OS and DSS after primary and repeat TA, and complications after TA. In cohorts matched for confounders, OSS and DSS were compared after TA with and without the intention to perform OLTx. RESULTS: After TA, 100 patients (56·8%) developed recurrent HCC, of whom 76 (76·0%) underwent up to four repeat interventions. During follow-up, 76·7% of patients never developed a recurrence unamenable to repeat TA or OLTx. OS was comparable after primary TA and repeat TA. In matched cohorts, OS and DSS were comparable after TA with and without the intention to perform OLTx. CONCLUSIONS: We found TA to be an effective and repeatable therapy for primary and recurrent HCC. Most recurrences can be treated with curative intent. There are patients who do well with TA alone without ever undergoing OLTx. KEY POINTS: • Recurrent HCC after primary TA can often be treated effectively with repeat TA. Survival after repeat TA is comparable to primary TA. • In matched cohorts, outcomes after TA with and without subsequent waitlisting for OLTx are comparable. • There are patients who do well for many years with primary and repeat TA alone; some despite multiple recurrences.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Trasplante de Hígado , Carcinoma Hepatocelular/patología , Hepatectomía/métodos , Humanos , Neoplasias Hepáticas/patología , Trasplante de Hígado/métodos , Recurrencia Local de Neoplasia/patología , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
4.
Int J Hyperthermia ; 39(1): 639-648, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35465802

RESUMEN

BACKGROUND: In thermal ablation of malignant liver tumors, ablation dimensions remain poorly predictable. This study aimed to investigate factors influencing volumetric ablation dimensions in patients treated with stereotactic microwave ablation (SMWA) for colorectal liver metastases (CRLM). METHODS: Ablation volumes from CRLM ≤3 cm treated with SMWA within a prospective European multicentre trial were segmented. Correlations between applied ablation energies and resulting effective ablation volumes (EAV) and ablation volume irregularities (AVI) were investigated. A novel measure for AVI, including minimum enclosing and maximum inscribed ellipsoid ablation volumes, and a surrogate parameter for the expansion of ablation energy (EAV per applied energy), was introduced. Potential influences of tumor and patient-specific factors on EAV per applied energy and AVI were analyzed using multivariable mixed-effects models. RESULTS: A total of 116 ablations from 71 patients were included for analyses. Correlations of EAV or AVI and ablation energy were weak to moderate, with a maximum of 25% of the variability in EAV and 13% in AVI explained by the applied ablation energy. On multivariable analysis, ablation expansion (EAV per applied ablation energy) was influenced mainly by the tumor radius (B = -0.03, [CI -0.04, -0.007]). AVI was significantly larger with higher applied ablation energies (B = 0.002 [CI 0.0007, 0.002]]); liver steatosis, KRAS mutation, subcapsular location or proximity to major blood vessels had no influence. CONCLUSIONS: This study confirmed that factors beyond the applied ablation energy might affect volumetric ablation dimensions, resulting in poor predictability. Further clinical trials including tissue sampling are needed to relate physical tissue properties to ablation expansion.


Asunto(s)
Ablación por Catéter , Neoplasias Colorrectales , Neoplasias Hepáticas , Ablación por Catéter/métodos , Neoplasias Colorrectales/patología , Humanos , Neoplasias Hepáticas/patología , Microondas/uso terapéutico , Estudios Prospectivos , Resultado del Tratamiento
5.
HPB (Oxford) ; 23(6): 827-839, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33218949

RESUMEN

BACKGROUND: Combining resection and thermal ablation can improve short-term postoperative outcomes in patients with colorectal liver metastases (CRLM). This study assessed nationwide hospital variation and short-term postoperative outcomes after combined resection and ablation. METHODS: In this population-based study, all CRLM patients who underwent resection in the Netherlands between 2014 and 2018 were included. After propensity score matching for age, ASA-score, Charlson-score, diameter of largest CRLM, number of CRLM and earlier resection, postoperative outcomes were compared. Postoperative complicated course (PCC) was defined as discharge after 14 days or a major complication or death within 30 days of surgery. RESULTS: Of 4639 included patients, 3697 (80%) underwent resection and 942 (20%) resection and ablation. Unadjusted percentage of patients who underwent resection and ablation per hospital ranged between 4 and 44%. Hospital variation persisted after case-mix correction. After matching, 734 patients remained in each group. Hospital stay (median 6 vs. 7 days, p = 0.011), PCC (11% vs. 14.7%, p = 0.043) and 30-day mortality (0.7% vs. 2.3%, p = 0.018) were lower in the resection and ablation group. Differences faded in multivariable logistic regression due to inclusion of major hepatectomy. CONCLUSION: Significant hospital variation was observed in the Netherlands. Short-term postoperative outcomes were better after combined resection and ablation, attributed to avoiding complications associated with major hepatectomy.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Neoplasias Colorrectales/cirugía , Hepatectomía/efectos adversos , Hospitales , Humanos , Neoplasias Hepáticas/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
6.
Radiology ; 290(3): 826-832, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30667337

RESUMEN

Purpose To compare the accuracy of freehand versus robotic antenna placement in CT-guided microwave ablation (MWA) of liver tumors. Materials and Methods This study was conducted as a prospective single-center nonblinded randomized controlled trial (Netherlands Trial Registry, NTR6023). Eligible study participants had undergone clinically indicated CT-guided MWA of liver tumors and were able to receive a CT contrast agent. Randomization was performed per tumor after identification on contrast material-enhanced CT images. The primary outcome was the number of antenna repositionings, which was compared by using the Mann-Whitney U test. Secondary outcomes were lateral targeting error stratified by in-plane and out-of-plane targets and targeting time. Results Between February 14 and November 12, 2017, 31 participants with a mean age of 63 years (range, 25-88 years) were included: 17 women (mean age, 57 years; range, 25-77 years) and 14 men (mean age, 70 years; range, 52-88 years). The freehand study arm consisted of 19 participants, while the robotic study arm consisted of 18 participants; six participants with multiple tumors were included in both arms. Forty-seven tumors were assessed; five tumors were excluded from the analysis because of technical limitations. In the robotic arm, no antenna repositioning was required. In the freehand arm, a median of one repositioning was required (range, zero to seven repositionings; P < .001). For out-of-plane targets, lateral targeting error was 10.1 mm ± 4.0 and 5.9 mm ± 2.9 (P = .007) for freehand and robotic procedures, respectively, and for in-plane targets, lateral targeting error was 6.2 mm ± 2.7 and 7.7 mm ± 5.9, respectively (P = .51). Mean targeting time was 19 minutes (range, 8-55 minutes) and 36 minutes (range, 3-70 minutes; P = .001) for freehand and robotic procedures, respectively. Conclusion Robotic antenna guidance reduces the need for antenna repositioning in microwave ablation to accurately target liver tumors and increases accuracy for out-of-plane targets. However, targeting time was greater with robotic guidance than with freehand targeting. © RSNA, 2019.


Asunto(s)
Ablación por Catéter/métodos , Neoplasias Hepáticas/cirugía , Microondas/uso terapéutico , Radiografía Intervencional/métodos , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Países Bajos , Estudios Prospectivos
7.
Eur Radiol ; 29(8): 4026-4035, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30506218

RESUMEN

OBJECTIVES: The aim of the present study is to analyze preclinical and clinical data on the performance of the currently US Food and Drug Administration (FDA)-approved microwave ablation (MWA) systems. METHODS: A review of the literature, published between January 1, 2005, and December 31, 2016, on seven FDA-approved MWA systems, was conducted. Ratio of ablation zone volume to applied energy R(AZ:E) and sphericity indices were calculated for ex vivo and in vivo experiments. RESULTS: Thirty-four studies with ex vivo, in vivo, and clinical data were summarized. In total, 14 studies reporting data on ablation zone volume and applied energy were included for comparison R(AZ:E). A significant correlation between volume and energy was found for the ex vivo experiments (r = 0.85, p < 0.001) in contrast to the in vivo experiments (r = 0.54, p = 0.27). CONCLUSION: Manufacturers' algorithms on microwave ablation zone sizes are based on preclinical animal experiments with normal liver parenchyma. Clinical data reporting on ablation zone volume in relation to applied energy and sphericity index during MWA are scarce and require more adequate reporting of MWA data. KEY POINTS: • Clinical data reporting on the ablation zone volume in relation to applied energy during microwave ablation are scarce. • Manufacturers' algorithms on microwave ablation zone sizes are based on preclinical animal experiments with normal liver parenchyma. • Preclinical data do not predict actual clinical ablation zone volumes in patients with liver tumors.


Asunto(s)
Técnicas de Ablación/instrumentación , Aprobación de Recursos , Neoplasias Hepáticas/cirugía , Hígado/patología , Microondas/uso terapéutico , Animales , Humanos , Hígado/cirugía , Neoplasias Hepáticas/patología , Estados Unidos , United States Food and Drug Administration
9.
Eur Radiol ; 28(8): 3228-3236, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29536242

RESUMEN

OBJECTIVES: To study the ratio of ablation zone volume to applied energy in computed tomography (CT)-guided radiofrequency ablation (RFA) and microwave ablation (MWA) in patients with hepatocellular carcinoma (HCC) in a cirrhotic liver and in patients with colorectal liver metastasis (CRLM). METHODS: In total, 90 liver tumors, 45 HCCs in a cirrhotic liver and 45 CRLMs were treated with RFA or with one of two MWA devices (MWA_A and MWA_B), resulting in 15 procedures for each tumor type, per device. Device settings were recorded and the applied energy was calculated. Ablation volumes were segmented on the contrast-enhanced CT scans obtained 1 week after the procedure. The ratio of ablation zone volume in milliliters to applied energy in kilojoules was determined for each procedure and compared between HCC (RHCC) and CRLM (RCRLM), stratified according to ablation device. RESULTS: With RFA, RHCC and RCRLM were 0.22 mL/kJ (0.14-0.45 mL/kJ) and 0.15 mL/kJ (0.14-0.22 mL/kJ; p = 0.110), respectively. With MWA_A, RHCC was 0.81 (0.61-1.07 mL/kJ) and RCRLM was 0.43 (0.35-0.61 mL/kJ; p = 0.001). With MWA_B, RHCC was 0.67 (0.41-0.85 mL/kJ) and RCRLM was 0.43 (0.35-0.61 mL/kJ; p = 0.040). CONCLUSIONS: With RFA, there was no significant difference in energy deposition ratio between tumor types. With both MWA devices, the ratios were higher for HCCs. Tailoring microwave ablation device protocols to tumor type might prevent incomplete ablations. KEY POINTS: • HCCs and CRLMs respond differently to microwave ablation • For MWA, CRLMs required more energy to achieve a similar ablation volume • Tailoring ablation protocols to tumor type might prevent incomplete ablations.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Ablación por Catéter/métodos , Neoplasias Colorrectales/cirugía , Diatermia/métodos , Neoplasias Hepáticas/cirugía , Anciano , Carcinoma Hepatocelular/patología , Neoplasias Colorrectales/patología , Diatermia/normas , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Márgenes de Escisión , Microondas , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
10.
BMC Musculoskelet Disord ; 17(1): 334, 2016 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-27511027

RESUMEN

BACKGROUND: There are two primary surgical techniques to reconstruct the anterior cruciate ligament (ACL), transtibial (TT) technique and anteromedial portal (AMP) technique. Currently, there is no consensus which surgical technique elicits the best clinical and functional outcomes. MRI-derived measures of the signal intensity (SI) of the ACL graft have been described as an independent predictor of graft properties. The purpose of this study is to compare the MRI derived SI measurements of the ACL graft one year after ACL reconstruction, in order to compare the outcomes of both the AMP and TT ACL reconstruction technique. METHODS/DESIGN: Thirty-six patients will be included in a randomized controlled trial. Patients who are admitted for primary unilateral ACL reconstruction will be included in the study. Exclusion criteria are a history of previous surgery on the ipsilateral knee, re-rupture of the ipsilateral ACL graft, associated ligamentous injuries or meniscal tear of the ipsilateral knee, unhealthy contralateral knee, contra-indications for MRI and a preference for one of the two surgical techniques and/or orthopaedic surgeon. Primary outcome is MRI Signal intensity ratio (SIR) of the ACL graft. Secondary outcome measures are the International Knee Documentation Committee (IKDC) Knee Examination Form,the Knee injury and Osteoarthritis Outcome Scores (KOOS) and the Anterior Cruciate Ligament OsteoArthritis Score (ACLOAS). Differences between MRI SIR assessment with the current MRI protocol (proton density weighted imaging protocol) and the additional T2*-weighted gradient-echo protocol will be assessed. DISCUSSION: There is no consensus regarding the TT or AMP ACL reconstruction technique. SI measurements with MRI have been used in other clinical studies for evaluation of the ACL graft and maturation after ACL reconstruction compared to clinical and functional outcomes. This randomized controlled trial has been designed to compare the TT technique with the AMP technique with the use of MRI SI of the graft after ACL reconstruction. TRIAL REGISTRATION: Netherlands Trial Registry NTR5410 (registered on August 24, 2015).


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/trasplante , Trasplantes/diagnóstico por imagen , Adolescente , Adulto , Ligamento Cruzado Anterior/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Países Bajos , Resultado del Tratamiento , Adulto Joven
11.
Abdom Radiol (NY) ; 49(4): 1122-1131, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38289352

RESUMEN

OBJECTIVES: Detecting ablation site recurrence (ASR) after thermal ablation remains a challenge for radiologists due to the similarity between tumor recurrence and post-ablative changes. Radiomic analysis and machine learning methods may show additional value in addressing this challenge. The present study primarily sought to determine the efficacy of radiomic analysis in detecting ASR on follow-up computed tomography (CT) scans. The second aim was to develop a visualization tool capable of emphasizing regions of ASR between follow-up scans in individual patients. MATERIALS AND METHODS: Lasso regression and Extreme Gradient Boosting (XGBoost) classifiers were employed for modeling radiomic features extracted from regions of interest delineated by two radiologists. A leave-one-out test (LOOT) was utilized for performance evaluation. A visualization method, creating difference heatmaps (diff-maps) between two follow-up scans, was developed to emphasize regions of growth and thereby highlighting potential ASR. RESULTS: A total of 55 patients, including 20 with and 35 without ASR, were included in the radiomic analysis. The best performing model was achieved by Lasso regression tested with the LOOT approach, reaching an area under the curve (AUC) of 0.97 and an accuracy of 92.73%. The XGBoost classifier demonstrated better performance when trained with all extracted radiomic features than without feature selection, achieving an AUC of 0.93 and an accuracy of 89.09%. The diff-maps correctly highlighted post-ablative liver tumor recurrence in all patients. CONCLUSIONS: Machine learning-based radiomic analysis and growth visualization proved effective in detecting ablation site recurrence on follow-up CT scans.


Asunto(s)
Recurrencia Local de Neoplasia , Radiómica , Humanos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Estudios de Seguimiento , Tomografía Computarizada por Rayos X/métodos , Aprendizaje Automático , Estudios Retrospectivos
12.
Eur J Cancer ; 187: 65-76, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37119639

RESUMEN

AIM: This multi-centre prospective cohort study aimed to investigate non-inferiority in patients' overall survival when treating potentially resectable colorectal cancer liver metastasis (CRLM) with stereotactic microwave ablation (SMWA) as opposed to hepatic resection (HR). METHODS: Patients with no more than 5 CRLM no larger than 30 mm, deemed eligible for both SMWA and hepatic resection at the local multidisciplinary team meetings, were deliberately treated with SMWA (study group). The contemporary control group consisted of patients with no more than 5 CRLM, none larger than 30 mm, treated with HR, extracted from a prospectively maintained nationwide Swedish database. After propensity-score matching, 3-year overall survival (OS) was compared as the primary outcome using Kaplan-Meier and Cox regression analyses. RESULTS: All patients in the study group (n = 98) were matched to 158 patients from the control group (mean standardised difference in baseline covariates = 0.077). OS rates at 3 years were 78% (Confidence interval [CI] 68-85%) after SMWA versus 76% (CI 69-82%) after HR (stratified Log-rank test p = 0.861). Estimated 5-year OS rates were 56% (CI 45-66%) versus 58% (CI 50-66%). The adjusted hazard ratio for treatment type was 1.020 (CI 0.689-1.510). Overall and major complications were lower after SMWA (percentage decrease 67% and 80%, p < 0.01). Hepatic retreatments were more frequent after SMWA (percentage increase 78%, p < 0.01). CONCLUSION: SMWA is a valid curative-intent treatment alternative to surgical resection for small resectable CRLM. It represents an attractive option in terms of treatment-related morbidity with potentially wider options regarding hepatic retreatments over the future course of disease.


Asunto(s)
Neoplasias del Colon , Neoplasias Colorrectales , Neoplasias Hepáticas , Humanos , Estudios Prospectivos , Hepatectomía , Microondas/uso terapéutico , Estudios Retrospectivos , Neoplasias Hepáticas/secundario , Neoplasias Colorrectales/patología , Neoplasias del Colon/cirugía
13.
EJNMMI Res ; 13(1): 77, 2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37644167

RESUMEN

BACKGROUND: Early detection of recurrent or progressive HCC remains the strongest prognostic factor for survival. Dual tracer PET/CT imaging with [11C]CH and [18F]FDG can further increase detection rates as both tracers entail different metabolic pathways involved in HCC development. We investigated dual-tracer PET/CT in clinical decision making in patients suspected of recurrent or progressive HCC. All HCC patients who underwent both [11C]CH and [18F]FDG PET/CT in our institute from February 2018 to December 2021 were included. Both tracer PET/CT were within 4 weeks of each other with at least 6-month follow-up. Patients underwent dual tracer PET/CT because of unexplained and suspicious CT/MRI or sudden rise of serum tumour markers. A detected lesion was considered critical when the finding had prognostic consequences leading to treatment changes. RESULTS: Nineteen patients who underwent [11C]CH and [18F]FDG PET/CT were included of which all but six patients were previously treated for HCC. Dual-tracer critical finding detection rate was 95%, with [18F]FDG 68%, and [11C]CH 84%. Intrahepatic HCC recurrence finding rate was 65% for both tracers. [18F]FDG found more ablation site recurrences (4/5) compared to [11C]CH (2/5). Only [11C]CH found two needle tract metastases. Both tracers found 75% of the positive lymph nodes. Two new primary tumours were found, one by [18F]FDG and both by [11C]CH. CONCLUSIONS: Our study favours a dual-tracer approach in HCC staging in high-risk patients or when conventional imaging is non-conclusive.

14.
EJNMMI Res ; 12(1): 9, 2022 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-35122166

RESUMEN

BACKGROUND: Post-therapy [90Y] PET/CT-based dosimetry is currently recommended to validate treatment planning as [99mTc] MAA SPECT/CT is often a poor predictor of subsequent actual [90Y] absorbed dose. Treatment planning software became available allowing 3D voxel dosimetry offering tumour-absorbed dose distributions and dose-volume histograms (DVH). We aim to assess dose-response effects in post-therapy [90Y] PET/CT dosimetry in SIRT-treated HCC patients for predicting overall and progression-free survival (OS and PFS) and four-month follow-up tumour response (mRECIST). Tumour-absorbed dose and mean percentage of the tumour volume (V) receiving ≥ 100, 150, 200, or 250 Gy and mean minimum absorbed dose (D) delivered to 30%, 50%, 70%, and 90% of tumour volume were calculated from DVH's. Depending on the mean tumour -absorbed dose, treated lesions were assigned to a < 120 Gy or ≥ 120 Gy group. RESULTS: Thirty patients received 36 SIRT treatments, totalling 43 lesions. Median tumour-absorbed dose was significantly different between the ≥ 120 Gy (n = 28, 207 Gy, IQR 154-311 Gy) and < 120 Gy group (n = 15, 62 Gy, IQR 49-97 Gy, p <0 .01). Disease control (DC) was found more frequently in the ≥ 120 Gy group (79%) compared to < 120 Gy (53%). Mean tumour-absorbed dose optimal cut-off predicting DC was 131 Gy. Tumour control probability was 54% (95% CI 52-54%) for a mean tumour-absorbed dose of 120 Gy and 90% (95% CI 87-92%) for 284 Gy. Only D30 was significantly different between DC and progressive disease (p = 0.04). For the ≥ 120 Gy group, median OS and PFS were longer (median OS 33 months, [range 8-33 months] and median PFS 23 months [range 4-33 months]) than the < 120 Gy group (median OS 17 months, [range 5-33 months] and median PFS 13 months [range 1-33 months]) (p < 0.01 and p = 0.03, respectively). CONCLUSIONS: Higher 3D voxel-based tumour-absorbed dose in patients with HCC is associated with four-month DC and longer OS and PFS. DVHs in [90Y] SIRT could play a role in evaluative dosimetry.

15.
Cancers (Basel) ; 14(22)2022 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-36428663

RESUMEN

Purpose: (i) to compare two 2.45 GHz MWA devices with respect to AZV in relation to the applied energy after MWA in patients with hepatocellular carcinoma (HCC) or colorectal liver metastasis (CRLM) and (ii) to identify potential confounders for this relationship. Methods: In total, 102 tumours, 65 CRLM and 37 HCC were included in this retrospective analysis. Tumours were treated with Emprint (n = 71) or Neuwave (n = 31) MWA devices. Ablation treatment setting were recorded and applied energy was calculated. AZV and tumour volumes were segmented on the contrast-enhanced CT scans obtained 1 week after treatment. The AZV to applied energy R(AZV:E) ratios were calculated for each tumour treatment and compared between both MWA devices and tumour types. Results: R(AZV:E)EMPRINT was 0.41 and R(AZV:E)NEUWAVE was 0.81, p < 0.001. Moderate correlation between AZV and applied energy was found for Emprint (r = 0.57, R2 = 0.32, p < 0.001) and strong correlation was found for Neuwave (r = 0.78, R2 = 0.61, p < 0.001). R(AZV:E)CRLM was 0.45 and R(AZV:E)HCC was 0.52, p = 0.270. Conclusion: This study confirms the unpredictability of AZVs based on the applied output energy for HCC and CRLM. No significant differences in R(AZV:E) were observed between CRLM and HCC. Significantly lower R(AZV:E) was found for Emprint devices compared to Neuwave; however, reflected energy due to cable and antenna design remains unclear and might contribute to these differences.

16.
Front Oncol ; 11: 713685, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34631539

RESUMEN

BACKGROUND: Stereotactic navigation techniques aim to enhance treatment precision and safety in minimally invasive thermal ablation of liver tumors. We qualitatively reviewed and quantitatively summarized the available literature on procedural and clinical outcomes after stereotactic navigated ablation of malignant liver tumors. METHODS: A systematic literature search was performed on procedural and clinical outcomes when using stereotactic or robotic navigation for laparoscopic or percutaneous thermal ablation. The online databases Medline, Embase, and Cochrane Library were searched. Endpoints included targeting accuracy, procedural efficiency, and treatment efficacy outcomes. Meta-analysis including subgroup analyses was performed. RESULTS: Thirty-four studies (two randomized controlled trials, three prospective cohort studies, 29 case series) were qualitatively analyzed, and 22 studies were included for meta-analysis. Weighted average lateral targeting error was 3.7 mm (CI 3.2, 4.2), with all four comparative studies showing enhanced targeting accuracy compared to free-hand targeting. Weighted average overall complications, major complications, and mortality were 11.4% (6.7, 16.1), 3.4% (2.1, 5.1), and 0.8% (0.5, 1.3). Pooled estimates of primary technique efficacy were 94% (89, 97) if assessed at 1-6 weeks and 90% (87, 93) if assessed at 6-12 weeks post ablation, with remaining between-study heterogeneity. Primary technique efficacy was significantly enhanced in stereotactic vs. free-hand targeting, with odds ratio (OR) of 1.9 (1.2, 3.2) (n = 6 studies). CONCLUSIONS: Advances in stereotactic navigation technologies allow highly precise and safe tumor targeting, leading to enhanced primary treatment efficacy. The use of varying definitions and terminology of safety and efficacy limits comparability among studies, highlighting the crucial need for further standardization of follow-up definitions.

17.
Front Oncol ; 11: 623098, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33777768

RESUMEN

BACKGROUND: In thermal ablation of liver tumors, complete coverage of the tumor volume by the ablation volume with a sufficient ablation margin is the most important factor for treatment success. Evaluation of ablation completeness is commonly performed by visual inspection in 2D and is prone to inter-reader variability. This work aimed to introduce a standardized approach for evaluation of ablation completeness after CT-guided thermal ablation of liver tumors, using volumetric quantitative ablation margins (QAM). METHODS: A QAM computation metric based on volumetric segmentations of tumor and ablation areas and signed Euclidean surface distance maps was developed, including a novel algorithm to address QAM computation in subcapsular tumors. The code for QAM computation was verified in artificial examples of tumor and ablation spheres simulating varying scenarios of ablation margins. The applicability of the QAM metric was investigated in representative cases extracted from a prospective database of colorectal liver metastases (CRLM) treated with stereotactic microwave ablation (SMWA). RESULTS: Applicability of the proposed QAM metric was confirmed in artificial and clinical example cases. Numerical and visual options of data presentation displaying substrata of QAM distributions were proposed. For subcapsular tumors, the underestimation of tumor coverage by the ablation volume when applying an unadjusted QAM method was confirmed, supporting the benefits of using the proposed algorithm for QAM computation in these cases. The computational code for developed QAM was made publicly available, encouraging the use of a standard and objective metric in reporting ablation completeness and margins. CONCLUSION: The proposed volumetric approach for QAM computation including a novel algorithm to address subcapsular liver tumors enables precision and reproducibility in the assessment of ablation margins. The quantitative feedback on ablation completeness opens possibilities for intra-operative decision making and for refined analyses on predictability and consistency of local tumor control after thermal ablation of liver tumors.

18.
Front Oncol ; 11: 757167, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34868968

RESUMEN

BACKGROUND: Three-dimensional (3D) volumetric ablation margin assessment after thermal ablation of liver tumors using software has been described, but its predictive value on treatment efficacy when accounting for other factors known to correlate ablation site recurrence (ASR) remains unknown. PURPOSE: To investigate 3D quantitative ablation margins (3D-QAMs) as an algorithm to predict ASR within 1 year after stereotactic microwave ablation (SMWA) for colorectal liver metastases (CRLM). MATERIALS AND METHODS: Sixty-five tumors in 47 patients from a prospective multicenter study of patients undergoing SMWA for CRLM were included in this retrospective 3D-QAM analysis. Using a previously developed algorithm, 3D-QAM defined as the distribution of tumor to ablation surface distances was assessed in co-registered pre- and post-ablation CT scans. The discriminatory power and optimal cutoff values for 3D-QAM were assessed using receiver operating characteristic (ROC) curves. Multivariable logistic regression analysis using generalized estimating equations was applied to investigate the impact of various 3D-QAM outputs on 1-year ASR while accounting for other known influencing factors. RESULTS: Ten of the 65 (15.4%) tumors included for 3D-QAM analysis developed ASR. ROC analyses identified i) 3D-QAM <1 mm for >23% of the tumor surface, ii) 3D-QAM <5 mm for >45%, and iii) the minimal ablation margin (MAM) as the 3D-QAM outputs with optimal discriminatory qualities. The multivariable regression model without 3D-QAM yielded tumor diameter and KRAS mutation as 1-year ASR predictors. When adding 3D-QAM, this factor became the main predictor of 1-year ASR [odds ratio (OR) 21.67 (CI 2.48, 165.21) if defined as >23% <1 mm; OR 0.52 (CI 0.29, 0.95) if defined as MAM]. CONCLUSIONS: 3D-QAM allows objectifiable and standardized assessment of tumor coverage by the ablation zone after SMWA. Our data shows that 3D-QAM represents the most important factor predicting ASR within 1 year after SMWA of CRLM.

19.
Cancers (Basel) ; 12(7)2020 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-32635230

RESUMEN

The guidelines for metastatic colorectal cancer crudely state that the best local treatment should be selected from a 'toolbox' of techniques according to patient- and treatment-related factors. We created an interdisciplinary, consensus-based algorithm with specific resectability and ablatability criteria for the treatment of colorectal liver metastases (CRLM). To pursue consensus, members of the multidisciplinary COLLISION and COLDFIRE trial expert panel employed the RAND appropriateness method (RAM). Statements regarding patient, disease, tumor and treatment characteristics were categorized as appropriate, equipoise or inappropriate. Patients with ECOG≤2, ASA≤3 and Charlson comorbidity index ≤8 should be considered fit for curative-intent local therapy. When easily resectable and/or ablatable (stage IVa), (neo)adjuvant systemic therapy is not indicated. When requiring major hepatectomy (stage IVb), neo-adjuvant systemic therapy is appropriate for early metachronous disease and to reduce procedural risk. To downstage patients (stage IVc), downsizing induction systemic therapy and/or future remnant augmentation is advised. Disease can only be deemed permanently unsuitable for local therapy if downstaging failed (stage IVd). Liver resection remains the gold standard. Thermal ablation is reserved for unresectable CRLM, deep-seated resectable CRLM and can be considered when patients are in poor health. Irreversible electroporation and stereotactic body radiotherapy can be considered for unresectable perihilar and perivascular CRLM 0-5cm. This consensus document provides per-patient and per-tumor resectability and ablatability criteria for the treatment of CRLM. These criteria are intended to aid tumor board discussions, improve consistency when designing prospective trials and advance intersociety communications. Areas where consensus is lacking warrant future comparative studies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA