Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38306687

RESUMEN

AIMS: Data on the hybrid atrial fibrillation (AF) treatment are lacking in patients with structural heart disease undergoing concomitant CryoMaze procedures. The aim was to assess whether the timely pre-emptive catheter ablation would achieve higher freedom from AF or atrial tachycardia (AT) and be associated with better clinical outcomes than surgical ablation alone. METHODS AND RESULTS: The trial investigated patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement with mandatory concomitant CryoMaze procedure who were randomly assigned to undergo either radiofrequency catheter ablation [Hybrid Group (HG)] or no further treatment (Surgery Group). The primary efficacy endpoint was the first recurrence of AF/AT without class I or III antiarrhythmic drugs as assessed by implantable cardiac monitors. The primary clinical endpoint was a composite of hospitalization for arrhythmia recurrence, worsening of heart failure, cardioembolic event, or major bleeding. We analysed 113 and 116 patients in the Hybrid and Surgery Groups, respectively, with a median follow-up of 715 (IQR: 528-1072) days. The primary efficacy endpoint was significantly reduced in the HG [41.1% vs. 67.4%, hazard ratio (HR) = 0.38, 95% confidence interval (CI): 0.26-0.57, P < 0.001] as well as the primary clinical endpoint (19.9% vs. 40.1%, HR = 0.51, 95% CI: 0.29-0.86, P = 0.012). The trial groups did not differ in all-cause mortality (10.6% vs. 8.6%, HR = 1.17, 95%CI: 0.51-2.71, P = 0.71). The major complications of catheter ablation were infrequent (1.9%). CONCLUSION: Pre-emptively performed catheter ablation after the CryoMaze procedure was safe and associated with higher freedom from AF/AT and improved clinical outcomes.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Resultado del Tratamiento , Taquicardia Supraventricular/cirugía , Antiarrítmicos/uso terapéutico , Hemorragia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
Rep Pract Oncol Radiother ; 29(3): 280-289, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39144262

RESUMEN

Background: Part of the current stereotactic arrythmia radioablation (STAR) workflow is transfer of findings from the electroanatomic mapping (EAM) to computed tomography (CT). Here, we analyzed inter- and intraobserver variation in a modified EAM-CT registration using automatic registration algorithms designed to yield higher robustness. Materials and methods: This work is based on data of 10 patients who had previously undergone STAR. Two observers participated in this study: (1) an electrophysiologist technician (cardiology) with substatial experience in EAM-CT merge, and (2) a clinical engineer (radiotherapy) with minimum experience with EAM-CT merge. EAM-CT merge consists of 3 main steps: segmentation of left ventricle from CT (CT LV), registration of the CT LV and EAM, clinical target volume (CTV) delineation from EAM specific points. Mean Hausdorff distance (MHD), Dice Similarity Coefficient (DSC) and absolute difference in Center of Gravity (CoG) were used to assess intra/interobserver variability. Results: Intraobserver variability: The mean DSC and MHD for 3 CT LVs altogether was 0.92 ± 0.01 and 1.49 ± 0.23 mm. The mean DSC and MHD for 3 CTVs altogether was 0,82 ± 0,06 and 0,71 ± 0,22 mm. Interobserver variability: Segmented CT LVs showed great similarity (mean DSC of 0,91 ± 0,01, MHD of 1,86 ± 0,47 mm). The mean DSC comparing CTVs from both observers was 0,81 ± 0,11 and MHD was 0,87 ± 0,45 mm. Conclusions: The high interobserver similarity of segmented LVs and delineated CTVs confirmed the robustness of the proposed method. Even an inexperienced user can perform a precise EAM-CT merge following workflow instructions.

3.
Radiat Oncol ; 19(1): 50, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637844

RESUMEN

BACKGROUND: Stereotactic ablative radiotherapy (SABR) is the standard treatment for medically inoperable early-stage non-small cell lung cancer (ES-NSCLC), but which patients benefit from stereotactic radiotherapy is unclear. The aim of this study was to analyze prognostic factors for early mortality. METHODS: From August 2010 to 2022, 617 patients with medically inoperable, peripheral or central ES-NSCLC were treated with SABR at our institution. We retrospectively evaluated the data from 172 consecutive patients treated from 2018 to 2020 to analyze the prognostic factors associated with overall survival (OS). The biological effective dose was > 100 Gy10 in all patients, and 60 Gy was applied in 3-5 fractions for a gross tumor volume (GTV) + 3 mm margin when the tumor diameter was < 1 cm; 30-33 Gy was delivered in one fraction. Real-time tumor tracking or an internal target volume approach was applied in 96% and 4% of cases, respectively. In uni- and multivariate analysis, a Cox model was used for the following variables: ventilation parameter FEV1, histology, age, T stage, central vs. peripheral site, gender, pretreatment PET, biologically effective dose (BED), and age-adjusted Charlson comorbidity index (AACCI). RESULTS: The median OS was 35.3 months. In univariate analysis, no correlation was found between OS and ventilation parameters, histology, PET, or centrality. Tumor diameter, biological effective dose, gender, and AACCI met the criteria for inclusion in the multivariate analysis. The multivariate model showed that males (HR 1.51, 95% CI 1.01-2.28; p = 0.05) and AACCI > 5 (HR 1.56, 95% CI 1.06-2.31; p = 0.026) were significant negative prognostic factors of OS. However, the analysis of OS showed that the significant effect of AACCI > 5 was achieved only after 3 years (3-year OS 37% vs. 56%, p = 0.021), whereas the OS in one year was similar (1-year OS 83% vs. 86%, p = 0.58). CONCLUSION: SABR of ES-NSCLC with precise image guidance is feasible for all medically inoperable patients with reasonable performance status. Early deaths were rare in our real-life cohort, and OS is clearly higher than would have been expected after best supportive care.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radiocirugia , Carcinoma Pulmonar de Células Pequeñas , Masculino , Humanos , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Estudios de Cohortes , Estudios Retrospectivos , Estadificación de Neoplasias , Análisis de Supervivencia , Carcinoma Pulmonar de Células Pequeñas/patología , Radiocirugia/métodos , Resultado del Tratamiento
4.
BMJ Open Respir Res ; 11(1)2024 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-38184317

RESUMEN

BACKGROUND: Inhaled corticosteroids have been widely reported as a preventive measure against the development of severe forms of COVID-19 not only in patients with asthma. METHODS: In 654 Czech and Slovak patients with asthma who developed COVID-19, we investigated whether the correct use of inhaler containing corticosteroids was associated with a less severe course of COVID-19 and whether this had an impact on the need for hospitalisation, measurable lung functions and quality of life (QoL). RESULTS: Of the studied cohort 51.4% had moderate persistent, 29.9% mild persistent and 7.2% severe persistent asthma. We found a significant adverse effect of poor inhaler adherence on COVID-19 severity (p=0.049). We also observed a lower hospitalisation rate in patients adequately taking the inhaler with OR of 0.83. Vital capacity and forced expiratory lung volume deterioration caused by COVID-19 were significantly reversed, by approximately twofold to threefold, in individuals who inhaled correctly. CONCLUSION: Higher quality of inhalation technique of corticosteroids measured by adherence to an inhaled medication application technique (A-AppIT) score had a significant positive effect on reversal of the vital capacity and forced expiratory lung volume in 1 s worsening (p=0.027 and p<0.0001, respectively) due to COVID-19. Scoring higher in the A-AppIT was also associated with significantly improved QoL. All measured variables concordantly and without exception showed a positive improvement in response to better adherence. We suggest that corticosteroids provide protection against the worsening of lungs in patients with COVID-19 and that correct and easily assessable adherence to corticosteroids with appropriate inhalation technique play an important role in preventing severe form of COVID-19.


Asunto(s)
Asma , COVID-19 , Humanos , Calidad de Vida , Asma/tratamiento farmacológico , Corticoesteroides , Volumen Espiratorio Forzado
5.
J Cardiothorac Surg ; 19(1): 397, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937763

RESUMEN

OBJECTIVES: Current recommendations support surgical treatment of atrial fibrillation (AF) in patients indicated for cardiac surgery. These procedures are referred to as concomitant and may be carried out using radiofrequency energy or cryo-ablation. This study aimed to assess the electrophysiological findings in patients undergoing concomitant cryo-ablation. METHODS: Patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement were included in the trial if concomitant cryo-ablation was part of the treatment plan according to current guidelines. The patients reported in this study were assigned to undergo staged percutaneous radiofrequency catheter ablation (PRFCA), i.e., hybrid treatment, as a part of the SURHYB trial protocol. RESULTS: We analyzed 103 patients who underwent PRFCA 105 ± 35 days after surgery. Left and right pulmonary veins (PVs) were found isolated in 65 (63.1%) and 63 (61.2%) patients, respectively. The LA posterior wall isolation and mitral isthmus conduction block were found in 38 (36.9%) and 18 (20.0%) patients, respectively. Electrical reconnections (gaps) in the left PVs were more often localized superiorly than inferiorly (57.9% vs. 26.3%, P = 0.005) and anteriorly than posteriorly (65.8% vs. 31.6%, P = 0.003). Gaps in the right PVs were more equally distributed anteroposteriorly but dominated in superior segments (72.5% vs. 40.0%, P = 0.003). There was a higher number of gaps on the roof line compared to the inferior line (131 (67.2%) vs. 67 (42.2%), P < 0.001). Compared to epicardial cryo-ablation, endocardial was more effective in creating PVs and LA posterior wall isolation (P < 0.05). Cryo-ablation using nitrous oxide (N20) or argon (Ar) gas as cooling agents was similarly effective (P = NS). CONCLUSIONS: The effectiveness of surgical cryo-ablation in achieving transmural and durable lesions in the left atrium is surprisingly low. Gaps are located predominantly in the superior and anterior portions of the PVs and on the roof line. Endocardial cryo-ablation is more effective than epicardial ablation, irrespective of the cooling agent used.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Criocirugía/métodos , Masculino , Femenino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Venas Pulmonares/cirugía , Resultado del Tratamiento , Puente de Arteria Coronaria/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA