Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Minim Invasive Ther Allied Technol ; 31(2): 291-296, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32662711

RESUMEN

AIMS: To report the largest single-center experience in surgical aortic valve replacement (SAVR) using the Enable sutureless bioprosthesis concerning the clinical outcome and hemodynamic behavior. MATERIAL AND METHODS: From April 2010 to May 2017, a total of 432 patients (36.3% of them women) received the Enable sutureless prosthesis for aortic valve stenosis, regurgitation, and/or endocarditis. The endpoints were overall survival after operation for 30 days and adverse events. RESULTS: No intraoperative complications occurred; intraoperative mortality was 0%. The 30-day mortality rate was 3.5% overall and 0.9% for isolated procedure. No valve-related deaths were observed. There was a need for prosthesis replacement during the early postoperative period in eight patients (1.9%): seven patients (1.6%) had a significant paravalvular leak and one patient (0.2%) developed early postoperative endocarditis. The maximum and mean pressure gradients across the prosthesis were 19.2 ± 7.1 mmHg and 11.1 ± 4.6 mmHg, respectively. A permanent pacemaker was necessary in 6.5% of the patients. CONCLUSIONS: The Enable sutureless prosthesis showed a reliable clinical outcome with low perioperative mortality and morbidity. The hemodynamic performance was satisfactory. Our data confirmed the safety of SAVR using the Enable bioprosthesis. However, a higher rate of pacemaker implantation (6.5%) has to be mentioned.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Diseño de Prótesis , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 98(5): E746-E757, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33555107

RESUMEN

BACKGROUND: There is a rising trend for transcatheter aortic valve implantation (TAVI) in bicuspid aortic stenosis patients. Data on the use of self-expandable (SEV) vs. balloon-expandable (BEV) valves in these patients are scarce. Therefore, we systematically compared clinical outcomes in bicuspid aortic stenosis patients treated with SEV and BEV. METHODS: Data were extracted from PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, Google Scholar and reference lists of relevant articles. Eight studies published from 2013 to 2020 including a total of 1,080 patients (BEV: n = 620; SEV: n = 460) were selected. Primary endpoints were procedural, 30-day and 1-year mortality. Secondary endpoints were new pacemaker implantation, annular rupture, coronary obstruction, moderate-to-severe paravalvular leak, need of second valve, stroke and acute kidney injury. RESULTS: We found no statistically significant difference in mortality between patients treated with BEV vs. SEV during index procedure, at 30 days and at 1 year. BEVs showed a statistically significant higher risk of annulus rupture (2.5%) in comparison with SEV (0%) (OR 5.81 [95% CI, 3.78-8.92], p < .001). New generation BEVs were also associated with significantly less paravalvular leak when compared to new generation SEVs (OR 0.08 [95% CI, 0.02-0.35], p = .001). CONCLUSIONS: This meta-analysis of observational studies of TAVI for bicuspid valves, showed no difference in short- and mid-term TAVI mortality with BEVs and SEVs. BEVs presented a higher risk of annular rupture in comparison with SEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Constricción Patológica , Humanos , Estudios Observacionales como Asunto , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Artif Organs ; 45(4): 338-345, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33001477

RESUMEN

Cryopreserved pulmonary homografts (PH) are the current gold standard for right ventricular outflow tract (RVOT) reconstruction in the Ross procedure. Unfortunately, their use is limited by a relatively scarce availability and high cost. Porcine stentless xenografts (SX) such as the Medtronic Freestyle SX are increasingly being used, although it is unclear whether the hemodynamic performance and the long-term durability are satisfactory. The present systematic review followed the Preferred Reporting Items for Systematic reviews and Meta-Analysis statement. The pooled treatment effects were calculated using a weighted DerSimonian-Laird random-effects model. We also evaluated the effect of time after RVOT reconstruction on valve gradients using meta-regression. Six studies with a total of 156 patients met the inclusion criteria. The pooled estimates for the pooled follow-up of 37 months were: 1.3% operative mortality, 94.8% overall survival, 7.5% structural valve deterioration, 5.2% reintervention, 73.3% asymptomatic, and 1.5% moderate or severe pulmonary insufficiency. Peak valve gradients were significantly correlated with time after RVOT, increasing during follow-up. Three studies compared PH with SX, one concluded that the SX is an acceptable alternative for RVOT reconstruction, whereas two concluded that this valvular substitute had inferior performance. The Freestyle SX can be considered as an alternative to PH, although it might be associated with more reinterventions, higher peak valve pressure gradients, and pulmonary valve dysfunction.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Válvula Pulmonar/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Animales , Humanos , Porcinos
4.
J Card Surg ; 36(2): 731-734, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33294992

RESUMEN

BACKGROUND: The adult type of anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is characterized by late presentation due to collateral coronary flow. Patients often present with long time recurrent angina or dyspnea. Surgical correction can be a challenge due to the vast collateral coronary circulation. CASE PRESENTATION: A previously healthy 41-year-old male presented in the emergency room referring typical angina and dyspnea. Coronary angiography revealed ALCAPA. Surgical correction was indicated. Under cardiopulmonary bypass, the left main coronary artery ostium was isolated and directly reimplanted in the aorta. The patient was discharged from the hospital without complications and asymptomatic. Control coronary angiography showed enlarged left main coronary artery and regression of the collateral circulation. CONCLUSION: Even with a well-developed collateral circulation, detachment of the left coronary artery and direct implantation in the aorta is feasible, achieving good long-term results.


Asunto(s)
Síndrome de Bland White Garland , Anomalías de los Vasos Coronarios , Adulto , Síndrome de Bland White Garland/diagnóstico por imagen , Síndrome de Bland White Garland/cirugía , Circulación Colateral , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/cirugía , Humanos , Masculino , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Reimplantación
5.
J Card Surg ; 36(6): 2113-2116, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33547669

RESUMEN

BACKGROUND: Left ventricular aneurysms (LVA) are serious complications of myocardial infarction, being divided into true and false type. The false one-pseudoaneurysm (PA), is a life-threatening condition that requires urgent treatment due to the high risk of rupture. CASE PRESENTATION: An 84-year-old female presented with progressive heart failure symptoms. Investigation showed a small true LVA and a large PA. Open surgical repair was ruled out as Euroscore and Society of Thoracic Surgeons (STS) score were 42.80% and 39.97%, respectively. After discussion at our Heart Team meeting, percutaneous approach was found to be the best option. Guided by transesophageal echocardiography, we used an interventricular septal defect occluder to close the gap between the LV and the PA. Control ventriculography showed full closure of the gap, with no residual flow to the PA cavity. The patient was discharged from the hospital on the fifth postoperative day and has remained asymptomatic since then. CONCLUSION: Percutaneous approach proved to be a safe and effective modality to treat LV PA. The device implanted achieved the goal of blocking blood flow through the communication between LV and the PA.


Asunto(s)
Aneurisma Falso , Aneurisma Cardíaco , Defectos del Tabique Interventricular , Dispositivo Oclusor Septal , Anciano de 80 o más Años , Aneurisma Falso/complicaciones , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Cateterismo Cardíaco , Femenino , Aneurisma Cardíaco/complicaciones , Aneurisma Cardíaco/diagnóstico por imagen , Aneurisma Cardíaco/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Resultado del Tratamiento
6.
J Card Surg ; 36(1): 286-289, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33085137

RESUMEN

In rare cases of extensive aortic root or mitral valve infective endocarditis (IE), severe calcification of the aortic and mitral valves, or double-valve procedures in patients with small aortic and mitral annuli, surgical reconstruction of the intervalvular fibrous body (IVFB) is required. A high mortality is generally associated with this procedure, and it is frequently avoided by surgeons due to a lack of experience. It is crucial to radically resect all tissues that are severely affected by IE to prevent recurrence in the patient. Our experience with the Commando procedure in patients with extensive double-valve IE involving the IVFB is presented in this article.


Asunto(s)
Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Procedimientos de Cirugía Plástica , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Endocarditis/cirugía , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía
7.
J Card Surg ; 36(9): 3289-3293, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34148261

RESUMEN

INTRODUCTION: The coronavirus disease 2019 (COVID-19) pandemic has been a worldwide challenge, and efforts to "flatten the curve," including restrictions imposed by policymakers and medical societies, have forced a reduction in the number of procedures performed in the Brazilian Health Care System. The aim of this study is to evaluate the outcomes of coronary artery bypass graft (CABG) from 2008 to 2020 in the SUS and to assess the impacts of the COVID-19 pandemic in the number of procedures and death rate of CABG performed in 2020 through the database DATASUS. METHODS: This study is based on publicly available material obtained from DATASUS, the Brazilian Ministry of Health's data processing system, on numbers of surgical procedures and death rates. Only isolated CABG procedures were included in our study. We used the TabNet software from the DATASUS website to generate reports. RESULTS: We identified 281,760 CABG procedures performed from January 2008 to December 2020. The average number of procedures until the end of 2019 was of 22,104. During 2020 there was a 25% reduction CABG procedures, to 16,501. There was an increase in the national death rate caused by a statistical significant increase in death rates in Brazil's Southeast and Central-west regions. CONCLUSION: The COVID-19 pandemic remains a global challenge for Brazil's health care system. During the year of 2020 there was a reduction in access to CABG related to an increase in the number of COVID-19 cases. There was also an increase in the national CABG death rate.


Asunto(s)
COVID-19 , Pandemias , Brasil/epidemiología , Puente de Arteria Coronaria , Humanos , SARS-CoV-2
8.
J Card Surg ; 36(4): 1226-1231, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33491207

RESUMEN

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) techniques are increasingly being adopted into clinical routine for various risk groups. Coronary artery disease (CAD) is seen in up to 75% of patients with severe aortic valve stenosis (AS) presenting with typical angina pectoris. Due to high mortality rates and procedural complications in these patients, a hybrid concept of simultaneous transaortic TAVI and off-pump coronary artery bypass (OPCAB) can be a feasible treatment option. METHODS: Between April 2014 and July 2020, 10 consecutive high-risk patients underwent concomitant transaortic TAVI and OPCAB at our institution. All indications were discussed in Heart Team and decisions were made based on patients' comorbidities and complexity of CAD. The study endpoints were 30-day mortality, device success, and development of postoperative adverse events defined by the Valve Academic Research Consorium. RESULTS: The mean age of the patients was 77.9 ± 7.1 years old. All patients presented with multiple comorbidities (mean logistic EuroSCORE 26.5 ± 12.3%, median EuroSCORE II 5.13% [interquartile range 4.2-9.5], mean STS-Score 6.04 ± 1.6%). Five patients (50%) presented with porcelain aorta. No conversion to conventional procedures was needed. 30-day mortality occurred in one patient (10%). Complete revascularization was achieved in seven (70%) of the patients. Device success rate was 100%. No paravalvular leakage was detected. No stroke, myocardial infarction or vascular complications were observed. CONCLUSIONS: A hybrid approach combining transaortic TAVI and OPCAB might be a safe and feasible method of treatment in high-risk patients presenting with severe AS and CAD who are not eligible for conventional surgical or interventional solutions.


Asunto(s)
Estenosis de la Válvula Aórtica , Puente de Arteria Coronaria Off-Pump , Enfermedad de la Arteria Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
9.
Curr Atheroscler Rep ; 22(2): 9, 2020 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-32034516

RESUMEN

PURPOSE OF REVIEW: This review summarizes the pathophysiology of mitral annular calcification (MAC) with recent findings and current strategies for diagnosis and treatment. RECENT FINDINGS: Major factors in MAC development seem to be shear stress of the flow past the mitral valve, local inflammation, and dysregulation in regulators of mineral metabolism. MAC itself poses daunting technical challenges. Implanting a valve on top of the calcium bar might lead to paravalvular leak (PVL) that is less likely to heal. Annular decalcification allows for better valve seating and potentially better healing and less PVL. This, however, comes with the risk for catastrophic atrioventricular groove disruption. MAC can be sharply dissected with the scalpel; the annulus can be reconstructed with the autologous pericardium. Transcatheter mitral valve replacement is a promising approach in the treatment of patients who are deemed high-risk surgical candidates with severe MAC. MAC is a multifactorial disease that has some commonalities with atherosclerosis, mainly regarding lipid accumulation and calcium deposition. It is of great clinical importance, being a risk marker of cardiovascular events (including sudden death) and, with its progression, can have a negative impact on patients' lives.


Asunto(s)
Aterosclerosis/fisiopatología , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/fisiopatología , Válvula Mitral/fisiopatología , Calcificación Vascular/diagnóstico , Calcificación Vascular/fisiopatología , Anciano , Calcio/sangre , Femenino , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/efectos adversos , Factores de Riesgo , Calcificación Vascular/cirugía
10.
J Card Surg ; 35(2): 503-506, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31856350

RESUMEN

We report a case of a hybrid surgical treatment of a 71-year-old fragile female with severe chronic obstructive pulmonary disease with a 5-year history of progressive back pain and diagnosis of descending thoracic aorta aneurysm (DTAA), but refused operation at first. Since the patient presented with an acute expanding painful pulsatile mass due to a ruptured DTAA contained by the subcutaneous tissue and had a high-risk surgical profile, we agreed that the simplest urgent operation should be performed. Cardiopulmonary bypass with or without deep hypothermic circulatory arrest was ruled out as an option. The initial approach would be permanent bypasses to the supra-aortic trunks and endovascular repair of the ruptured DTAA, but we ran into a problem: the absence of suitable diameter in the ascending aorta to land the prosthesis-zone 0. To overcome this obstacle, we opted to perform a diameter reduction of the ascending aorta by wrapping it with a Dacron tube to create a neck where we could land the endovascular prosthesis. Following this step bypasses from the proximal ascending aorta to the brachiocephalic artery, left common carotid artery and left subclavian artery were created. Since we gained ground to act in zone 0, the first endoprosthesis was landed in the wrapped zone and the aortic arch-from zone 0 to zone 3. The second and third endoprostheses covered the ruptured DTAA above the celiac trunk-zones 4 and 5. Good positioning of the endoprostheses was achieved and we attained procedural success.


Asunto(s)
Aorta Torácica/cirugía , Aorta/cirugía , Aneurisma de la Aorta Torácica/cirugía , Rotura de la Aorta/cirugía , Procedimientos Endovasculares/métodos , Procedimientos Quirúrgicos Vasculares/métodos , Anciano , Femenino , Humanos , Prótesis e Implantes , Resultado del Tratamiento
11.
J Card Surg ; 35(9): 2307-2323, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32668091

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Minimally invasive cardiac surgery (MICS) for mitral valve repair (MVRp) has been increasingly used. This study aimed to evaluate the early and late results of MICS for MVRp vs conventional sternotomy. MATERIALS AND METHODS: A systematic review of randomized controlled trials or observational studies (with matched populations) comparing MICS and conventional MVRp reporting any of the following outcomes: mortality, MVRp failure, complications, blood transfusion, readmission within 30 days after discharge, long-term reoperation for mitral regurgitation, operative times, mechanical ventilation time, intensive care unit (ICU) stay, or hospital stay. The pooled treatment effects were calculated using a random-effects model. RESULTS: Ten studies involving 6792 patients (MICS: 3396 patients; Conventional: 3296 patients) met the eligibility criteria. In the pooled analysis, MICS significantly reduced the risk for blood transfusion (odds ratio [OR], 0.654; 95% confidence interval [CI] 0.462-0.928; P = .017) and readmission within 30 days after discharge (OR, 0.615; 95% 0.456-0.829; P = .001). MICS was associated with a significantly longer cross-clamp time (mean difference 14 minutes; 95% CI, 7.4-21 minutes; P < .001), CPB time (24 minutes; 95% CI, 14-35 minutes; P < .001), and total operative time (36; 95% CI, 15-56 minutes; P < .001), but a significantly shorter ICU stay (-8.5; 95% CI -15; -1.8; P = .013) and hospital stay (-1.3, 95% CI -2.1; -0.45; P = .003). This meta-analysis found no significant difference regarding the risk of in-hospital and long-term mortality, nor complications. CONCLUSIONS: Despite longer operative times, MICS for MVRp reduces ICU and hospital stay, as well as readmission rates and the need for transfusion.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Enfermedades de las Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Tiempo de Internación , Procedimientos Quirúrgicos Mínimamente Invasivos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Esternotomía , Resultado del Tratamiento
12.
J Card Surg ; 35(12): 3660-3662, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33032372

RESUMEN

BACKGROUND: Aortic root and ascending aortic aneurysms are traditionally surgically treated through the deployment of a conduit with an artificial aortic valve, which significantly increases the risk of postoperative complications in the form of thrombosis. MATERIALS & METHODS: We report a case of Wolfe procedure in a 78-year-old female patient with aortic root aneurysm at high risk for conventional Bentall surgery. DISCUSSION AND CONCLUSION: We use this case to discuss the effectiveness and short-term results of this procedure.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Femenino , Humanos , Complicaciones Posoperatorias
13.
Medicina (Kaunas) ; 56(9)2020 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-32842512

RESUMEN

Background and Objectives: Since the first use of ventricular assist devices (VADs) as bridge to recovery and bridge to cardiac transplantation in the early 1990s, significant technological advances have transformed VAD implantation into a routine destination therapy. With improved survival, many patients present for cardiac surgery for conditions not directly related to their permanent mechanical circulatory support. The aim of this study was to analyze the indications and outcomes of non-cardiac surgeries (NCSs) of left ventricular assist device (LVAD) patients in tertiary center. Material and Methods: We present a single-center experience after 151 LVAD implantations in 138 consecutive patients between 2012-2019 who had to undergo NCS during a follow-up period of 37 +/- 23.4 months on left ventricular assist device (LVAD). Results: A total of 105 procedures was performed in 63 LVAD recipients, resulting in peri-operative mortality of 3.8%. Twenty-five (39.7%) of patients underwent multiple surgeries. We found no significant difference in cumulative survival associated with the performed surgical interventions (p = 0.469). Conclusion: We demonstrated good overall clinical outcomes in LVAD patients undergoing NCS. With acceptable peri-operative mortality, NCS can be safely performed in LVAD patients on long-term support.


Asunto(s)
Corazón Auxiliar , Atención Perioperativa , Procedimientos Quirúrgicos Operativos/efectos adversos , Anticoagulantes/efectos adversos , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Procedimientos Quirúrgicos Operativos/mortalidad
14.
Rev Port Cardiol ; 32(2): 131-7, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23333215

RESUMEN

INTRODUCTION: Ischemic mitral regurgitation (IMR) is associated with increased mortality. Even after coronary artery bypass grafting (CABG), IMR reduces survival. Several studies have shown increased perioperative mortality for mitral valve replacement (MVR) in this situation, but the subject remains controversial. OBJECTIVE: To investigate the impact of MVR on immediate outcomes in patients with moderate-to-severe IMR undergoing concomitant CABG compared with those undergoing CABG only. METHODS: We performed a retrospective study of 42 patients undergoing CABG+MVR (n=16) or CABG only (n=26) at the Division of Cardiovascular Surgery of PROCAPE, between May 2007 and April 2010. Preoperative clinical characteristics, procedural characteristics, major and minor complications after surgery, preoperative and postoperative left ventricular ejection fraction (LVEF) by echocardiography, and outcome (survivor or death) were assessed. RESULTS: Mean patient age was 63.4 ± 8.5 years, and 64.8% (n=23) were male. The CABG+MVR group showed lower rates of postoperative low cardiac output (6.3% vs. 42.3%, p=0.014) and atrial fibrillation (6.3% vs. 38.5%, p=0.021). Both groups had higher mean LVEF in the postoperative compared with the preoperative period, but the average gain in LVEF in the CABG+MVR group was higher than in the CABG-only group (8.88 ± 2.39 vs. 4.31 ± 1.23, p<0.001). There was no significant difference in operative mortality (6.3% vs. 7.7%, p=0.679). CONCLUSIONS: CABG+MVR can be performed safely in patients with moderate-to-severe IMR. CABG+MVR resulted in lower rates of complications than CABG only. Both surgical approaches resulted in significant improvement of postoperative LVEF. However, there was greater improvement in the CABG+MVR group.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad Coronaria/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Enfermedad Coronaria/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
15.
Ann Thorac Surg ; 113(4): 1192-1199, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34048758

RESUMEN

BACKGROUND: Surgical aortic valve replacement (SAVR) for patients with aortic valve stenosis (AS) with small aortic root is associated with a higher rate of prosthesis-patient mismatch and suboptimal clinical outcomes. Aortic valve neocuspidization using xenologous pericardium (xAVNeo) has shown a favorable hemodynamic performance. The aim was to compare 6-year clinical outcomes of xAVNeo with SAVR. METHODS: Between 2003 and 2018, 412 patients with severe AS and small aortic root received either xAVNeo (n = 114) or bioprosthesis (n = 298). After propensity matching the cohort included 222 patients. The primary endpoints were early mortality, 6-year mortality, and freedom from reoperation. Mean follow-up averaged 3.4 ± 3.1 years and was 95% complete. RESULTS: Early mortality was 8.1% for the SAVR group versus 9.9% for the xAVNeo group (odds ratio, 1.25; 95% confidence interval, 0.51-2.89). The estimated survival probabilities at 6 years for the SAVR and xAVNeo cohorts were 89.9% and 88.8%, respectively (odds ratio, 1.07; 95% confidence interval, 0.49-2.34). Progressive degeneration of the neocusps resulted in a mean gradient increase from 6.1 ± 2.3 mm Hg to 22.7 ± 11.5 mm Hg (P < .0001); cusp sclerosis was the most common indication for reoperation in the xAVNeo group with a linearized rate of 1.92% versus 0.26% per patient-year (rate ratio, 7.41; 95% confidence interval, 0.95-333.7). The freedom from reoperation was 84.8% at 6 years, inferior to that of the SAVR group (100%). CONCLUSIONS: Early clinical outcomes and 6-year survival rates after xAVNeo and SAVR were comparable. However xAVNeo using bovine pericardium was associated with a higher rate of structural valve deterioration and inferior freedom from reoperation when compared with SAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Animales , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bovinos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Pericardio/cirugía , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
16.
Braz J Cardiovasc Surg ; 37(5): 710-720, 2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-34673507

RESUMEN

INTRODUCTION: Transcatheter aortic valve-in-valve implantation (TAVI-ViV) can be associated with unfavorable hemodynamic outcomes. This study aimed to estimate the prevalence, identify the risk factors, and evaluate the outcomes and survival of patients with high residual gradients after TAVI-ViV. METHODS: A total of 85 patients were included in the study. The cohort was divided into group A, with postprocedural mean pressure gradient (PG) ≥ 20 mmHg, and group B, with mean PG < 20 mmHg. RESULTS: Postprocedural PG ≥ 20 mmHg was observed in 24.7% of the patients. In a univariate analysis, preoperative gradient, pre-existing patient-prosthesis mismatch (PPM), deep valve implantation, small degenerated valves, and an older generation of transcatheter aortic valves were found to be risk factors for high residual gradient. Multivariate analysis showed that preexisting maxPG > 60 mmHg, implantation level of 4 mm below neo-annulus, and degenerated valve size ≤ 23 mm were independent predictors of high residual gradient. There were no differences in early morbidity (myocardial infarction, pacemaker implantation, stroke, acute renal insufficiency) between groups. Kaplan-Meier estimated that the survival rate was comparable at one and five years regardless of postoperative gradient. Survivors with high residual mean gradient were significantly affected by a high New York Heart Association (NYHA) class. CONCLUSION: High residual transvalvular gradient after TAVI-ViV is not rare, but it does not significantly affect mortality. High residual mean gradient has a negative impact on NYHA functional class improvement after the procedure. High preoperative gradient, implantation level, and small failed bioprosthesis may predispose to increased residual gradient.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Falla de Prótesis , Diseño de Prótesis , Resultado del Tratamiento , Bioprótesis/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo , Análisis Factorial
17.
Braz J Cardiovasc Surg ; 37(1): 13-19, 2022 03 10.
Artículo en Inglés | MEDLINE | ID: mdl-34673508

RESUMEN

INTRODUCTION: The objective of this study was to identify risk factors for deep sternal wound infection (DSWI) after off-pump coronary artery bypass (OPCAB) grafting surgery. METHODS: A total of 8,442 patients undergoing OPCAB from April 1, 2009 to December 31, 2018 were retrospectively analyzed. A total of 956 were eventually enrolled on this study based on our exclusion criteria. All subjects were divided into two groups: group 1 (n=63) - DSWI; group 2 (n=893) - without DSWI. Patients were excluded if they had one of the following: acute coronary syndrome, conversion to OPCAB grafting surgery, redo procedure, concomitant cardiac surgery procedures. RESULTS: The prevalence of body mass index (BMI) ≥40 kg/m2 (7.9% vs. 1.9%, respectively; P=0.01), lower extremity atherosclerotic artery disease (23.8% vs. 7.2%, respectively; P=0.001) and use of bilateral internal thoracic artery (19.5% vs. 2.5%, respectively; P=0.008) was significantly higher in patients with DSWI. The incidence of morbidities, including reoperation for bleeding (26.4% vs. 2.1%, respectively; P<0.001), stroke (4.8% vs. 0.8%, respectively; P=0.02), acute renal failure (7.9% vs. 0.8%, respectively; P=0.001), delirium (7.9% vs. 1.7%, respectively; P=0.008) and blood transfusion (30.6% vs. 9.8%, respectively; P<0.001) was significantly higher in patients with DSWI. CONCLUSIONS: A BMI of >40 kg/m2, lower extremity artery disease, use of bilateral internal thoracic artery (BITA) graft, postoperative stroke, sepsis, reoperation due to postoperative complications and blood product requirement significantly increased the risk of sternal infection after OPCAB.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Enfermedad de la Arteria Coronaria , Estudios de Casos y Controles , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria Off-Pump/efectos adversos , Enfermedad de la Arteria Coronaria/etiología , Humanos , Estudios Retrospectivos , Factores de Riesgo , Infección de la Herida Quirúrgica/etiología , Resultado del Tratamiento
18.
Interact Cardiovasc Thorac Surg ; 34(2): 201-211, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34542639

RESUMEN

OBJECTIVES: Extended reality (XR), encompassing both virtual reality (VR) and augmented reality, allows the user to interact with a computer-generated environment based on reality. In essence, the immersive nature of VR and augmented reality technology has been warmly welcomed in all aspects of medicine, gradually becoming increasingly feasible to incorporate into everyday practice. In recent years, XR has become increasingly adopted in thoracic surgery, although the extent of its applications is unclear. Here, we aim to review the current applications of XR in thoracic surgery. METHODS: A systematic database search was conducted of original articles that explored the use of VR and/or augmented reality in thoracic surgery in EMBASE, MEDLINE, Cochrane database and Google Scholar, from inception to December 2020. RESULTS: Our search yielded 1494 citations, of which 21 studies published from 2007 to 2019 were included in this review. Three main areas were identified: (i) the application of XR in thoracic surgery training; (ii) preoperative planning of thoracic procedures; and (iii) intraoperative assistance. Overall, XR could produce progression along the learning curve, enabling trainees to reach acceptable standards before performing in the operating theatre. Preoperatively, through the generation of 3D-renderings of the thoracic cavity and lung anatomy, VR increases procedural accuracy and surgical confidence through familiarization of the patient's anatomy. XR-assisted surgery may have therapeutic use particularly for complex cases, where conventional methods would yield inadequate outcomes due to inferior accuracy. CONCLUSION: XR represents a salient step towards improving thoracic surgical training, as well as enhancing preoperative planning and intraoperative guidance.


Asunto(s)
Realidad Aumentada , Cirugía Torácica , Procedimientos Quirúrgicos Torácicos , Realidad Virtual , Humanos , Quirófanos
19.
Ann Thorac Surg ; 113(3): 1036-1046, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-33378694

RESUMEN

BACKGROUND: The benefits of pulmonary valve replacement (PVR) for pulmonary insufficiency in patients with repaired tetralogy of Fallot are still incompletely understood, and optimal timing remains challenging. METHODS: We systematically reviewed databases (PubMed/MEDLINE, Embase, Cochrane Central Register of Controlled Trials /Cochrane Controlled Trials Register, ClinicalTrials.gov, Scientific Electronic Library Online, Literatura Latino Americana em Ciências da Saúde, and Google Scholar) and reference lists of relevant articles for studies about PVR in repaired tetralogy of Fallot patients that reported any of the following outcomes: mortality and redo PVR rates, right ventricular (RV) and left ventricular measures, QRS duration, cardiopulmonary exercise test results, or brain natriuretic peptide. In addition to calculating the pooled treatment effects using a random-effects meta-analysis, we evaluated the effect of preoperative measures on PVR outcomes using meta-regressions. RESULTS: Eighty-four studies involving 7544 patients met the eligibility criteria. Pooled mortality at 30 days, 5 years, and 10 years after PVR was 0.87% (63 of 7253 patients, 80 studies), 2.7% (132 of 4952 patients, 37 studies), and 6.2% (510 of 2765 patients, 15 studies), respectively. Pooled 5- and 10-year redo PVR rates were 3.7% (141 of 3755 patients, 23 studies) and 16.8% (172 of 3035 patients, 16 studies), respectively. The results of the previous meta-analysis could be confirmed. In addition, we demonstrated that after PVR (1) QRS duration, cardiopulmonary exercise test results, and RV and left ventricular measures longitudinal strain do not significantly change; (2) brain natriuretic peptide decreases; and (3) greater indexed RV end-diastolic and end-systolic volumes are associated with lower chances of RV volume normalization after PVR. CONCLUSIONS: This updated meta-analysis provides evidence about the benefits of PVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Tetralogía de Fallot , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Péptido Natriurético Encefálico , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Estudios Retrospectivos , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía , Resultado del Tratamiento
20.
Braz J Cardiovasc Surg ; 36(4): 453-460, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-34617426

RESUMEN

INTRODUCTION: Open access (OA) publishing often requires article processing charges (APCs). While OA provides opportunities for broader readership, authors able to afford APCs are more commonly associated with well-funded, high-income country institutions, skewing knowledge dissemination. Here, we evaluate publishing models, OA practices, and APCs in cardiology and cardiac surgery. METHODS: The InCites Journal Citation Reports 2019 directory by Clarivate Analytics was searched for "Cardiac and Cardiovascular Systems" journals. Sister journals of included journals were identified. All journals were categorized as predominantly cardiology or cardiac surgery. Publishing models, APCs, and APC waivers were defined for all journals. RESULTS: One hundred sixty-one journals were identified (139 cardiology, 22 cardiac surgery). APCs ranged from $244 to $5,000 ($244-5,000 cardiology; $383-3,300 cardiac surgery), with mean $2,911±891 and median $3,000 (interquartile range [IQR]: $2,500-3,425) across 139 journals with non-zero available APCs ($2,970±890, median $3,000, IQR: $2,573-3,450, cardiology; $2,491±799, median $2,740, IQR: $2,300-3,000, cardiac surgery). Average APCs were $3,307±566 and median $3,250 (IQR: $3,000-3,500) for hybrid journals ($3,344±583, median $3,260, IQR: $3,000-3,690, cardiology; $2,983±221, median $2,975, IQR: $2,780-3,149, cardiac surgery) and $1,997±832 and median $2,100 (IQR: $1,404-2,538) for fully OA journals ($2,039±843, median $2,100, IQR: $1,419-2,604, cardiology; $1,788±805, median $2,000, IQR: $1,475-2,345, cardiac surgery). Waivers were available for 51 (86.4%) fully OA and 37 (37.4%) hybrid journals. Seventeen journals were fully OA without APCs, one journal did not yet release APCs, and four journals were subscription-only. CONCLUSION: OA publishing is common in cardiology and cardiac surgery with substantial APCs. Waivers remain limited, posing barriers for unfunded and lesser-funded researchers.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiología , Publicaciones Periódicas como Asunto , Acceso a la Información , Estudios Transversales , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA