J Clin Microbiol ; 60(2): e0178521, 2022 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-34911366

RESUMEN

Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and presymptomatic transmission, curb the spread of variants, and maximize treatment efficacy. Low-analytical-sensitivity nasal-swab testing is commonly used for surveillance and symptomatic testing, but the ability of these tests to detect the earliest stages of infection has not been established. In this study, conducted between September 2020 and June 2021 in the greater Los Angeles County, California, area, initially SARS-CoV-2-negative household contacts of individuals diagnosed with COVID-19 prospectively self-collected paired anterior-nares nasal-swab and saliva samples twice daily for viral-load quantification by high-sensitivity reverse-transcription quantitative PCR (RT-qPCR) and digital-RT-PCR assays. We captured viral-load profiles from the incidence of infection for seven individuals and compared diagnostic sensitivities between respiratory sites. Among unvaccinated persons, testing saliva with a high-analytical-sensitivity assay detected infection up to 4.5 days before viral loads in nasal swabs reached concentrations detectable by low-analytical-sensitivity nasal-swab tests. For most participants, nasal swabs reached higher peak viral loads than saliva but were undetectable or at lower loads during the first few days of infection. High-analytical-sensitivity saliva testing was most reliable for earliest detection. Our study illustrates the value of acquiring early (within hours after a negative high-sensitivity test) viral-load profiles to guide the appropriate analytical sensitivity and respiratory site for detecting earliest infections. Such data are challenging to acquire but critical to designing optimal testing strategies with emerging variants in the current pandemic and to respond to future viral pandemics.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Nasofaringe , Pandemias , Saliva , Manejo de Especímenes
2.
PLoS One ; 18(10): e0292389, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37796850

RESUMEN

At-home rapid COVID-19 tests in the U.S. utilize nasal-swab specimens and require high viral loads to reliably give positive results. Longitudinal studies from the onset of infection have found infectious virus can present in oral specimens days before nasal. Detection and initiation of infection-control practices may therefore be delayed when nasal-swab rapid tests are used, resulting in greater transmission to contacts. We assessed whether index cases first identified by rapid nasal-swab COVID-19 tests had more transmission to household contacts than index cases who used other test types (tests with higher analytical sensitivity and/or non-nasal specimen types). In this observational cohort study, 370 individuals from 85 households with a recent COVID-19 case were screened at least daily by RT-qPCR on one or more self-collected upper-respiratory specimen types. A two-level random intercept model was used to assess the association between the infection outcome of household contacts and each covariable (household size, race/ethnicity, age, vaccination status, viral variant, infection-control practices, and whether a rapid nasal-swab test was used to initially identify the household index case). Transmission was quantified by adjusted secondary attack rates (aSAR) and adjusted odds ratios (aOR). An aSAR of 53.6% (95% CI 38.8-68.3%) was observed among households where the index case first tested positive by a rapid nasal-swab COVID-19 test, which was significantly higher than the aSAR for households where the index case utilized another test type (27.2% 95% CI 19.5-35.0%, P = 0.003 pairwise comparisons of predictive margins). We observed an aOR of 4.90 (95% CI 1.65-14.56) for transmission to household contacts when a nasal-swab rapid test was used to identify the index case, compared to other test types. Use of nasal-swab rapid COVID-19 tests for initial detection of infection and initiation of infection control may be less effective at limiting transmission to household contacts than other test types.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiología , SARS-CoV-2 , Composición Familiar , Estudios de Cohortes , Nariz
3.
Microbiol Spectr ; 10(6): e0387322, 2022 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-36287073

RESUMEN

Optimizing specimen collection methods to achieve the most reliable SARS-CoV-2 detection for a given diagnostic sensitivity would improve testing and minimize COVID-19 outbreaks. From September 2020 to April 2021, we performed a household-transmission study in which participants self-collected specimens every morning and evening throughout acute SARS-CoV-2 infection. Seventy mildly symptomatic participants collected saliva, and of those, 29 also collected nasal swab specimens. Viral load was quantified in 1,194 saliva and 661 nasal swab specimens using a high-analytical-sensitivity reverse transcription-quantitative PCR (RT-qPCR) assay. Viral loads in both saliva and nasal swab specimens were significantly higher in morning-collected specimens than in evening-collected specimens after symptom onset. This aspect of the biology of SARS-CoV-2 infection has implications for diagnostic testing. We infer that morning collection would have resulted in significantly improved detection and that this advantage would be most pronounced for tests with low to moderate analytical sensitivity. Collecting specimens for COVID-19 testing in the morning offers a simple and low-cost improvement to clinical diagnostic sensitivity of low- to moderate-analytical-sensitivity tests. IMPORTANCE Our findings suggest that collecting saliva and nasal swab specimens in the morning immediately after waking yields higher SARS-CoV-2 viral loads than collection later in the day. The higher viral loads from morning specimen collection are predicted to significantly improve detection of SARS-CoV-2 in symptomatic individuals, particularly when using moderate- to low-analytical-sensitivity COVID-19 diagnostic tests, such as rapid antigen tests.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Prueba de COVID-19 , Saliva , Técnicas de Laboratorio Clínico/métodos , Carga Viral , Manejo de Especímenes/métodos
4.
medRxiv ; 2021 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-33851180

RESUMEN

Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and pre-symptomatic transmission, curb the spread of variants by travelers, and maximize treatment efficacy. Low-sensitivity nasal-swab testing (antigen and some nucleic-acid-amplification tests) is commonly used for surveillance and symptomatic testing, but the ability of low-sensitivity nasal-swab tests to detect the earliest stages of infection has not been established. In this case-ascertained study, initially-SARS-CoV-2-negative household contacts of individuals diagnosed with COVID-19 prospectively self-collected paired anterior-nares nasal-swab and saliva samples twice daily for viral-load quantification by high-sensitivity RT-qPCR and digital-RT-PCR assays. We captured viral-load profiles from the incidence of infection for seven individuals and compared diagnostic sensitivities between respiratory sites. Among unvaccinated persons, high-sensitivity saliva testing detected infection up to 4.5 days before viral loads in nasal swabs reached the limit of detection of low-sensitivity nasal-swab tests. For most participants, nasal swabs reached higher peak viral loads than saliva, but were undetectable or at lower loads during the first few days of infection. High-sensitivity saliva testing was most reliable for earliest detection. Our study illustrates the value of acquiring early (within hours after a negative high-sensitivity test) viral-load profiles to guide the appropriate analytical sensitivity and respiratory site for detecting earliest infections. Such data are challenging to acquire but critical to design optimal testing strategies in the current pandemic and will be required for responding to future viral pandemics. As new variants and viruses emerge, up-to-date data on viral kinetics are necessary to adjust testing strategies for reliable early detection of infections.