Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 144(4): 1603-1609, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38441618

RESUMEN

INTRODUCTION: Distal radioulnar joint (DRUJ) instabilities are challenging and their optimal treatment is controversial. In special cases or when reconstruction of the stabilizing triangular fibrocartilage complex (TFCC) fails, K-wire transfixation can be performed. However, no consensus has been reached regarding the rotational position of the forearm in which this should be done. Therefore, it was investigated whether anatomical reduction would best be achieved by transfixation in neutral position or supination of the forearm. MATERIALS AND METHODS: Twelve cadaveric upper limbs were examined before dissection of the DRUJ stabilizing ligaments and after closed transfixation in both positions by C-arm cone-beam CT. Whether this was first done in neutral position or in supination was randomized. The change in the radioulnar ratio (RR) in percentage points (%points) was analyzed using Student's t-test. RR was used since it is a common and sensitive method to evaluate DRUJ reduction, expressing the ulnar head's position in the sigmoid notch as a length ratio. RESULTS: The analysis showed an increased change in RR in neutral position with 5.4 ± 9.7%points compared to fixation in supination with 0.2 ± 16.1%points, yet this was not statistically significant (p = 0.404). CONCLUSIONS: Neither position leads to a superior reduction in general. However, the result was slightly closer to the anatomical position in supination. Thus, transfixation of the DRUJ should be performed in the position in which reduction could best be achieved and based on these data, that tends to be in supination. Further studies are necessary to validate these findings and to identify influential factors.


Asunto(s)
Antebrazo , Inestabilidad de la Articulación , Humanos , Supinación , Pronación , Fenómenos Biomecánicos , Articulación de la Muñeca/cirugía , Cadáver , Inestabilidad de la Articulación/cirugía
2.
BMC Musculoskelet Disord ; 24(1): 850, 2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37891527

RESUMEN

BACKGROUND: Surgical treatment of distal clavicle fractures Neer type II is challenging. A gold standard has not yet been established, thus various surgical procedures have been described. The purpose of this study is to report the radiological and clinical outcomes using hook plate fixation in Neer type II distal clavicle fractures. METHODS: We retrospectively reviewed data of 53 patients who underwent hook plate fixation between December 2009 and December 2019 with ≥ 2 years of follow-up. Patients with preexisting pathologies or concomitant injuries of the ipsilateral shoulder were excluded. Pre- and postoperative coracoclavicular distance (CCD), bony union and patient-reported outcomes were collected, including the Constant Score (CS) and Subjective Shoulder Value (SSV). Complications and revisions were recorded. RESULTS: At a mean final follow-up of 6.2 years, mean SSV was 91.0% (range, 20-100) and mean CS was 80.9 points (range, 25-99). The mean preoperative CCD was 19.0 mm (range, 5.7-31.8), the mean postoperative CCD was 8.2 mm (range, 4.4-12.2) and the mean CCD following hardware removal was 9.7 mm (range, 4.7-18.8). The loss of reduction following hardware removal was statistically significant (P = 0.007). Eleven (20.8%) patients had complications, with 5 cases of deep or superficial infection (9.4%), four non-unions (7.5%), one periosteosynthetic fracture, one postoperative seroma, one implant failure and one symptomatic acromioclavicular joint arthritis (all 1.9%). A total of 10 patients (18.9%) underwent revision surgery at a mean of 113 (range, 7-631) days. CONCLUSION: Medium-term patient-reported outcomes for hook plate fixation of Neer type II distal clavicle fractures are satisfactory; however, one in five patients suffers a complication with the majority of them requiring revision surgery.


Asunto(s)
Fijación Interna de Fracturas , Fracturas Óseas , Humanos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Clavícula/diagnóstico por imagen , Clavícula/cirugía , Clavícula/lesiones , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Óseas/etiología , Placas Óseas/efectos adversos
3.
J Shoulder Elbow Surg ; 32(9): 1909-1917, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36907312

RESUMEN

BACKGROUND: Vitality-threatening proximal humerus fractures often provide an indication for prosthetic treatment. We investigated the issue of how anatomic hemiprostheses perform in younger, functionally challenging patients with the use of a specific fracture stem and systematic tuberosity management in medium-term follow-up. METHODS: Thirteen skeletally mature patients with a mean age of 64 ± 9 years and a minimum follow-up of 1 year after primary open-stem hemiarthroplasty for 3- and 4-part proximal humeral fractures were included. All patients were followed up regarding their clinical course. Radiologic follow-up included fracture classification, healing of tuberosities, proximal migration of the humeral head, evidence of stem loosening, and glenoid erosion. Functional follow-up included range of motion, pain, objective and subjective performance scores, complications, and return to sports rates. We statistically compared treatment success based on the Constant score between the cohort with proximal migration and the cohort with regular acromiohumeral distance by means of the Mann-Whitney U test. RESULTS: After an average follow-up period of 4.8 years, satisfactory results were obtained. The absolute Constant-Murley score was 73.2 ± 12.4 points. The disabilities of the arm, shoulder, and hand score was 13.2 ± 13.0 points. Patients reported their mean subjective shoulder value as 86.6% ± 8.5%. Pain was reported as 1.1 ± 1.3 points on a visual analog scale. Flexion, abduction, and external rotation values were 138 ± 31°, 134 ± 34°, and 32 ± 17°, respectively. 84.6% of the referred tuberosities healed successfully. Proximal migration was observed in 38.5% of cases and was associated with worse Constant score results (P = .065). No patient showed signs of loosening. Mild glenoid erosion was apparent in 4 patients (30.8%). All patients who were interviewed and participated in sports before surgery were able to return to their primary sport after surgery and continued to do so during the final follow-up. CONCLUSIONS: With narrow indications, use of a specific fracture stem and adequate tuberosity management, successful radiographic and functional results are presented after a mean follow-up of 4.8 years after hemiarthroplasty for primary nonreconstructable humeral head fractures. Accordingly, open-stem hemiarthroplasty appears to remain a possible alternative to reverse shoulder arthroplasty in younger, functionally challenging patients with primary 3- or 4-part proximal humeral fractures.


Asunto(s)
Hemiartroplastia , Fracturas del Hombro , Articulación del Hombro , Humanos , Persona de Mediana Edad , Anciano , Hemiartroplastia/métodos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Dolor , Rango del Movimiento Articular , Estudios Retrospectivos
4.
Arch Orthop Trauma Surg ; 143(8): 4853-4860, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36795151

RESUMEN

INTRODUCTION: One current trend in the field of shoulder arthroplasty is a design shift to shorter and metaphyseal fixed humeral stem components. The aim of this investigation is to analyze complications resulting in revision surgery after anatomic (ASA) and reverse (RSA) short stem arthroplasty. We hypothesize that complications are influenced by the type of prosthesis and indication for arthroplasty. MATERIALS AND METHODS: A total of 279 short stem shoulder prostheses were implanted by the same surgeon (162 ASA; 117 RSA), and 223 of these prostheses were implanted as primary procedures; in 54 cases, arthroplasty was performed secondary to prior open surgery. Main indications were osteoarthritis (OA) (n = 134), cuff tear arthropathy (CTA) (n = 74) and posttraumatic deformities (PTr) (n = 59). Patients were evaluated at 6 weeks (follow-up 1; FU1), 2 years (FU2) and the time span of the last follow-up defined as FU3 with a minimum FU of 2 years. Complications were categorized into early complications (within FU1), intermediate complications (within FU2) and late complications (> 2 years; FU3). RESULTS: In total, 268 prostheses (96.1%) were available for FU1; 267 prostheses (95.7%) were available for FU2 and 218 prostheses (77.8%) were available for FU3. The average time for FU3 was 53.0 months (range 24-95). A complication leading to revision occurred in 21 prostheses (7.8%), 6 (3.7%) in the ASA group and 15 (12.7%) in the RSA group (p < 0.005). The most frequent cause for revision was infection (n = 9; 42.9%). After primary implantation, 3 complications (2.2%) occurred in the ASA and 10 complications (11.0%) in the RSA group (p < 0.005). The complication rate was 2.2% in patients with OA, 13.5% in CTA and 11.9% in PTr. CONCLUSIONS: Primary reverse shoulder arthroplasty had a significantly higher rate of complications and revisions than primary and secondary anatomic shoulder arthroplasty, respectively. Therefore, indications for reverse shoulder arthroplasty should be critically questioned in each individual case.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Prótesis de Hombro/efectos adversos , Osteoartritis/cirugía , Osteoartritis/etiología , Húmero/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Reoperación , Rango del Movimiento Articular
5.
Arch Orthop Trauma Surg ; 142(11): 3395-3403, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35059824

RESUMEN

INTRODUCTION: The interval slide procedure (IS) has been introduced to improve mobility in massive, retracted rotator cuff tears. As clinical studies showed controversial results, the benefit of the IS is still widely discussed. AIM: Aim of this study was to analyze the effect of IS procedure on tendon mobility in a fresh porcine cadaver model. MATERIALS AND METHODS: In 30 fresh porcine cadaver shoulders with artificial supraspinatus defect tendon mobility was tested by measuring the load (in N) during tendon reduction to the footprint at the greater tubercle using a sensor enhanced arthroscopic grasper (t1). In intervention group (N = 15) anterior IS (t2), posterior IS (t3) and intraarticular capsule release (t4) were successively performed, each followed by tendon mobility assessment. Tendon mobility of the control group (N = 15) was measured in same time schedule without intervention. RESULTS: Mobility did not differ between groups for native tendons (CG 28.0 ± 11.2 N vs. IG 26.6 ± 11.6 N; P = 0.75). IS procedure significantly improves mobility at about 25.2% (t1 26.6 ± 11.6 N vs. t4 19.9 ± 12.3 N; P < 0.001) compared to the native tendon and 34.1% compared to CG (CG 30.2 ± 13.7 N vs. 19.9 ± 12.3 N; P = 0.026). In posthoc analyzes, anterior IS (P < 0.001) and capsule release (P = 0.005) significantly increased mobility, whereas the posterior IS did not (P = 0.778). CONCLUSION: The IS procedure results in increased supraspinatus tendon mobility in fresh porcine cadaver shoulders. However, performing the posterior IS subsequent to the anterior IS no significant improvement of mobility has been observed.


Asunto(s)
Lesiones del Manguito de los Rotadores , Traumatismos de los Tendones , Animales , Fenómenos Biomecánicos , Cadáver , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Porcinos , Traumatismos de los Tendones/cirugía
6.
J Shoulder Elbow Surg ; 30(7): e361-e369, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33484832

RESUMEN

BACKGROUND: The purposes of this study were (1) to report functional outcomes; (2) to assess complications, revisions, and survival rate; and (3) to assess differences in functional outcomes between removed and retained radial head arthroplasties (RHAs), early and delayed treatment, and type of RHA used at long-term follow-up after monopolar RHA for unreconstructible radial head fractures or their sequelae. METHODS: Seventy-eight patients (mean age, 59.2 years) who were at least 6 years postoperatively after monopolar RHA for unreconstructible RHFs or their sequelae were included. The Mayo Elbow Performance Score (MEPS); Quick Disability of the Arm, Shoulder, and Hand (QuickDASH) score; visual analog scale; postoperative satisfaction (1-6, 6 = highly unsatisfied); range of motion; complications; and revisions were assessed. Radiographic findings were reported. Kaplan-Meier survival analysis was performed. Subgroups (RHA type, early vs. delayed surgery, RHA removed vs. retained) were compared. RESULTS: At a median clinical follow-up of 9.5 years (range: 6.0-28.4 years), median MEPS was 80.0 (interquartile range [IQR]: 60.0-97.5), median QuickDASH was 22.0 (IQR: 4.6-42.6), median visual analog scale was 1 (IQR: 0-4), median postoperative satisfaction was 2 (IQR: 1-3), and median arc of extension/flexion was 110° (IQR: 80°-130°). Radiographic follow-up was available for 48 patients at a median of 7.0 years (range: 2.0-15.0 years). Heterotopic ossifications were seen in 14 (29.2%), moderate-to-severe capitellar osteopenia/abrasion in 3 (6.1%), moderate-to-severe ulnohumeral degeneration in 3 (6.1%), and periprosthetic radiolucencies in 17 (35.4%) patients. Twenty-nine patients (37.2%) had complications and 20 patients (25.6%) underwent RHA exchange or removal. Kaplan-Meier analysis with failure defined as RHA exchange or removal demonstrated survival of 75.1% (95% confidence interval: 63.7-83.3) at 18 years. The highest annual failure rate was observed in the first year in which the RHAs of 7 patients (9%) were exchanged or removed. No significant differences were detected between type of RHA in MEPS (Mathys: 82.5 [75.0-100] vs. Evolve: 80.0 [60.0-95.0]; P = .341) and QuickDASH (Mathys: 12.5 [0-34.4] vs. Evolve: 26.7 [6.9-46.2]; P = .112). Early surgery (≤3 weeks) yielded significantly superior MEPS (80.0 [70.0-100.0] vs. 52.5 [30.0-83.8]; P = .014) and QuickDASH (18.6 [1.5-32.6] vs. 46.2 [31.5-75.6]; P = .002) compared with delayed surgery (>3 weeks). Patients with retained RHAs had significantly better MEPS (80.0 [67.5-100] vs. 70.0 [32.5-82.5]; P = .016) and QuickDASH (18.1 [1.7-31.9] vs. 49.1 [22.1-73.8]; P = .007) compared with patients with removed RHAs. CONCLUSIONS: Long-term outcomes for RHA are satisfactory; however, there is a high complication and revision rate, resulting in implant survival of 75.1% at 18 years with the highest annual failure rate observed in the first postoperative year.


Asunto(s)
Articulación del Codo , Fracturas del Radio , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/cirugía , Humanos , Persona de Mediana Edad , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Rango del Movimiento Articular , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
7.
Arch Orthop Trauma Surg ; 141(10): 1649-1657, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32780199

RESUMEN

INTRODUCTION: The aim of the present study was to analyze the injury pattern and thus the dislocation mechanism after simple elbow dislocation using radiographs and magnetic resonance imaging (MRI) data sets. MATERIALS AND METHODS: The MRI data sets of 64 patients with a mean age of 44 years (18-77 years) were analyzed retrospectively. The inclusion criteria for the study were (1) radiograph with confirmed simple elbow dislocation, (2) low-energy trauma, (3) MRI of the affected elbow ≤ 3 weeks after trauma. The dislocation direction was determined using radiographs. The integrity of the lateral collateral ligament complex (LCLC), common extensor origin (CEO), anterior capsule (AC), medial collateral ligament (MCL), and common flexor origin (CFO) as well as the joint congruity were assessed based on MRI. RESULTS: 34 patients (53%) had a posterolateral, 26 patients (41%) a posterior, and 4 patients (6%) a posteromedial dislocation. LCLC and AC were affected in 64 out of 64 patients (100%). MCL was affected in 58 patients (91%). CEO were affected in 25 patients (39%) and the CFO in 20 patients (31%). In 11 patients (17%) the injury pattern was more pronounced medially than laterally (MCL, CFO, LCLC), with 2 of these patients exhibiting only a partial LCLC tear. All cases with joint incongruency (n = 12, 19%) showed CEO and/or CFO involvement. CONCLUSIONS: Simple elbow dislocation leads to a very heterogeneous spectrum of soft tissue injury pattern. A small proportion of patients showed medially pronounced injury patterns. These findings strongly indicate existence of a "reversed Horii circle" with an underlying valgus mechanism (medial force induction) originating and continuing from medial to anterior.


Asunto(s)
Ligamentos Colaterales , Articulación del Codo , Inestabilidad de la Articulación , Adulto , Codo , Articulación del Codo/diagnóstico por imagen , Humanos , Estudios Retrospectivos
8.
Arthroscopy ; 36(1): 178-185, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31864574

RESUMEN

PURPOSE: To compare and evaluate knee laxity and functional outcomes between autologous bone graft and silicate-substituted calcium phosphate (Si-CaP) in the treatment of tunnel defects in 2-stage revision anterior cruciate ligament reconstruction (ACLR). METHODS: This prospective, randomized controlled trial was conducted between 2012 and 2015 with a total of 40 patients who underwent 2-stage revision ACLR. The tunnels were filled with autologous iliac crest cancellous bone graft in 20 patients (control group) and with Si-CaP in the other 20 patients (intervention group). After a minimum follow-up period of 2 years, functional outcomes were assessed by KT-1000 arthrometry (side-to-side [STS] difference), the Tegner score, the Lysholm score, and the International Knee Documentation Committee score. RESULTS: A total of 37 patients (follow-up rate, 92.5%) with an average age of 31 years were followed up for 3.4 years (range, 2.2-5.5 years). The KT-1000 measurement did not show any STS difference between the bone graft group (0.9 ± 1.5 mm) and the Si-CaP group (0.7 ± 2.0 mm) (P = .731). One patient in the intervention group (5%) had an STS difference greater than 5 mm. Both groups showed significant improvements in the Tegner score, Lysholm score, and International Knee Documentation Committee score from preoperative assessment to final follow-up (P ≤ .002), without any difference between the 2 groups (P ≥ .396). Complications requiring revision occurred in 4 control patients (22%) and in 2 patients in the intervention group (11%) (P = .660). No complications in relation to Si-CaP were observed. CONCLUSIONS: Equivalent knee laxity and clinical function outcomes were noted 3 years after surgery in both groups of patients. Si-CaP bone substitute is therefore a safe alternative to autologous bone graft for 2-stage ACLR. LEVEL OF EVIDENCE: Level I, prospective, randomized controlled clinical trial.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Trasplante Óseo/métodos , Compuestos de Calcio/farmacología , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/cirugía , Rango del Movimiento Articular/fisiología , Silicatos/farmacología , Adulto , Lesiones del Ligamento Cruzado Anterior/complicaciones , Lesiones del Ligamento Cruzado Anterior/diagnóstico , Lesiones del Ligamento Cruzado Anterior/fisiopatología , Autoinjertos , Sustitutos de Huesos , Femenino , Estudios de Seguimiento , Humanos , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Masculino , Estudios Prospectivos , Radiografía , Reoperación , Factores de Tiempo , Resultado del Tratamiento
9.
Arch Orthop Trauma Surg ; 140(8): 1073-1079, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32236714

RESUMEN

INTRODUCTION: Rotator cuff tears (rct) subsequent to glenohumeral dislocation are relevant concomitant injuries, can lead to impaired shoulder function and increase risk of recurrent dislocation. AIM: The aim of this study was to determine the functional outcome, recurrent dislocation rate and tendon integrity after rotator cuff repair after primary traumatic shoulder dislocation. MATERIALS AND METHODS: In this retrospective case series, 23 patients (age 56.4 years ± 6.3) who underwent a rotator cuff reconstruction after primary traumatic shoulder dislocation with confirmed combination of full-thickness RCT and Bankart lesion were enrolled after a minimum follow-up of 2 years. Clinical outcome (age and gender adjusted Constant Murley Score (CMS), DASH, Rowe Score) (n = 23) and sonographic tendon integrity (n = 19) were studied. RESULTS: After a mean follow-up of 58 ± 32 months, a CMS of 85.1% ± 14.7, DASH of 14.2 ± 20.5, and Rowe Score of 82.4 ± 15.2 indicated good functional outcome. In 4 of 19 patients (21.1%) a re-tear was found during sonographic evaluation. In 3 cases (13%), a revision was performed (2 × stiff shoulder, 1 × postoperative infection). One patient had a single traumatic re-dislocation (4.3%). CONCLUSIONS: Patients undergone reconstruction of the rotator cuff following a primary traumatic shoulder dislocation can achieve good functional results and a low rate of recurrent dislocation. Postoperative tendon integrity is comparable with known data about non traumatic tears.


Asunto(s)
Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/cirugía , Luxación del Hombro/cirugía , Lesiones de Bankart/cirugía , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Tendones/cirugía , Resultado del Tratamiento
10.
J Shoulder Elbow Surg ; 28(8): 1441-1448, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31227468

RESUMEN

BACKGROUND: The aim of this study was to analyze sports participation after radial head arthroplasty among recreational athletes. METHODS: A total of 57 recreational athletes (mean age, 49 years; age range, 18-79 years) treated with radial head arthroplasty for non-reconstructible radial head fractures were included in this retrospective study. The return-to-sports rate and the time to return to sports were analyzed. The clinical and radiologic outcomes were compared between patients who returned to sports (group 1) and those who did not (group 2). RESULTS: After a mean follow-up period of 8.4 years (range, 2.5-16.4 years), 30 of 57 patients (53%) had returned to sports. The mean sports frequency significantly decreased from 5.2 ± 5.0 h/week to 2.2 ± 2.9 h/week after surgery (P < .001). In group 1, 83% of patients returned to the same sports activity whereas 17% changed to a less demanding sports activity. The mean time to return to sports was 158 days (range, 21-588 days). Patients who returned to sports had a significantly better Mayo Elbow Performance Score (MEPS) (84 ± 19 points vs. 63 ± 20 points, P < .001); Disabilities of the Arm, Shoulder and Hand score (16 ± 17 vs. 46 ± 22, P < .001); and arc of flexion (114° ± 32° vs. 89° ± 36°, P = .007). A secondary radial head prosthesis (P = .046) and MEPS lower than 85 points (P = .001) were associated with a significantly lower return-to-sports rate. No differences regarding radiographic changes were found between the 2 groups (P ≥ .256). CONCLUSION: The return-to-sports rate after radial head replacement is low. A secondary radial head prosthesis and a worse clinical outcome (MEPS < 85 points) significantly increase the risk of not returning to sports after radial head arthroplasty.


Asunto(s)
Artroplastia/métodos , Articulación del Codo/cirugía , Predicción , Fracturas del Radio/cirugía , Radio (Anatomía)/cirugía , Rango del Movimiento Articular/fisiología , Volver al Deporte , Adolescente , Adulto , Anciano , Articulación del Codo/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Radio (Anatomía)/diagnóstico por imagen , Fracturas del Radio/fisiopatología , Estudios Retrospectivos , Deportes , Resultado del Tratamiento , Adulto Joven , Lesiones de Codo
11.
J Shoulder Elbow Surg ; 28(4): 715-723, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30473242

RESUMEN

BACKGROUND: Several short-stemmed press-fit humeral components have been developed in recent years for anatomic total shoulder arthroplasty (TSA) as well as reverse shoulder arthroplasty (RSA). Varying radiographic outcomes have been reported, with some studies reporting concerning rates of aseptic loosening. This study analyzed the radiographic findings of a press-fit convertible short-stemmed humeral component in both TSA and RSA. METHODS: There were 150 anatomic TSAs (group 1) and 77 RSAs (group 2) analyzed radiographically at a minimum follow-up of 2 years postoperatively. Plain radiographs were reviewed for stem loosening, alignment, signs of stress shielding, and the filling ratio. RESULTS: At final follow-up, 49% of group 1 and 65% of group 2 had no evidence for radiographic changes. In those with radiographic changes, low bone adaptions were found in 83% and high adaptions in 17% in both groups. Larger stem sizes with higher filling ratios were associated with high radiographic adaptions in both groups (P = .02). The overall filling ratios were higher in group 2 (P = .002). Cortical contact of the stem led to higher bone adaptions (P = .014). CONCLUSIONS: The short humeral component analyzed in this study showed encouraging survival rates without aseptic loosening. Radiographic changes are associated with a higher filling ratio and cortical contact of the stem. Surgeons should aim to achieve fixation with the minimal required canal filling to minimize radiographic changes with the uncemented humeral component used in this study.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Articulación del Hombro/diagnóstico por imagen , Prótesis de Hombro , Adulto , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Diseño de Prótesis , Falla de Prótesis , Radiografía , Estudios Retrospectivos , Resultado del Tratamiento
12.
J Shoulder Elbow Surg ; 28(8): 1457-1467, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30713065

RESUMEN

BACKGROUND: Radial head fractures lead to persisting disability in a considerable number of cases. This study aimed to investigate their most common revision causes and procedures. METHODS: This multicenter retrospective study reviewed the cases of 466 adult patients who had undergone surgical revision after operative or nonoperative treatment of a radial head fracture. The initial diagnosis was a Mason type I fracture in 13.0%, Mason type II fracture in 14.6%, Mason type III fracture in 22.8%, Mason type IV fracture in 20.9%, terrible-triad injury in 12.8%, Monteggia-like lesion in 13.1%, and Essex-Lopresti lesion in 2.0%. Initial treatment was nonoperative in 30.2%, open reduction and internal fixation (ORIF) in 44.9%, radial head arthroplasty in 16.6%, radial head resection in 3.7%, sole treatment of concomitant injuries in 2.6%, and fragment excision in 2.0%. Up to 3 revision causes and procedures were recorded per case. RESULTS: The most common complications were stiffness (67.4%), instability (36.5%), painful osteoarthritis (29.2%), ORIF related (14.8%), nonunion or necrosis (9.2%), radial head arthroplasty related (7.5%), ulnar neuropathy (6.0%), and infection (2.6%). Revision procedures frequently included arthrolysis (42.1%), arthroplasty (24.9%), implant removal (23.6%), ligament repair or reconstruction (23.0%), débridement (14.2%), repeated ORIF (8.2%), and/or radial head resection (7.7%). Mason type I or II fractures were primarily revised because of stiffness and painful osteoarthritis. Complications after Mason type III fractures were predominantly ORIF related. Fracture-dislocations showed a wide range of complications, with instability and stiffness comprising the most common causes of revision. CONCLUSIONS: The complications of radial head fractures are characteristic to their classification. Knowledge of these findings might guide surgeons in treating these injuries and may help counsel patients accordingly.


Asunto(s)
Articulación del Codo/cirugía , Fractura-Luxación/cirugía , Fijación Interna de Fracturas/métodos , Reducción Abierta/métodos , Fracturas del Radio/cirugía , Adulto , Articulación del Codo/diagnóstico por imagen , Femenino , Fractura-Luxación/diagnóstico , Humanos , Masculino , Fracturas del Radio/diagnóstico , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento , Lesiones de Codo
13.
Arch Orthop Trauma Surg ; 139(2): 149-154, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30242565

RESUMEN

INTRODUCTION: The aim of the study was to evaluate the short-term clinical results of anatomic total shoulder arthroplasty with a short-stem prosthesis in primary osteoarthritis. MATERIALS AND METHODS: 65 shoulders with a mean age of 70 years (range 47-85 years) were available for minimum follow-up of 24 months. Clinical outcome was determined by range of motion, Constant score (CS) age and sex-adjusted Constant score (CS%), and subjective shoulder value (SSV). The influence of six different factors (high bone adaptations, age > 65 years, female gender, dominant side, atrophy of the supraspinatus tendon ≥ grade 2, glenoid type B2/B3) on the clinical outcome was assessed. RESULTS: At mean follow-up of 37 months (range 24-58 months), the CS improved from 36 ± 8 to 75 ± 12 (p < 0.001). The shoulder flexion (100° ± 21° to 159° ± 19°) as well as the external rotation (3° ± 11° to 43° ± 18°) improved significantly (p < 0.001). Three complications were noted (transient neuropraxia of the radial nerve, subjective instability, hematoma with superficial wound infection) leading to one revision surgery (wound debridement). No stem loosening was observed. High bone adaptation was present in 19 out of 65 shoulders (29%). The clinical outcome was not influenced by high bone adaptations (p ≥ 0.095). Age > 65 years (n = 44) and female gender (n = 38) were associated with worse clinical outcome (p ≤ 0.043). CONCLUSIONS: In the short term, the clinical results of this anatomical short-stem shoulder prosthesis are encouraging. A low prevalence of high bone adaptations was found without any influence on the clinical outcome and stem loosening was not observed.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Complicaciones Posoperatorias , Articulación del Hombro , Prótesis de Hombro , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico , Osteoartritis/cirugía , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Radiografía/métodos , Rango del Movimiento Articular , Reoperación/métodos , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento
14.
Arch Orthop Trauma Surg ; 139(11): 1543-1549, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30989412

RESUMEN

INTRODUCTION: The aim of this study was to evaluate a radiographic measurement method for assessment of overlengthening of the MoPyC radial head prosthesis. MATERIALS AND METHODS: Seven cadaver specimens were studied in ten stages: native specimen (1), radial head resection (2), and implantation of the MoPyC radial head prostheses (Bioprofile, Tornier, Montbonnot-Saint-Martin, France) in four increasing length (correct length, overlengthening of 1.5 mm, 3 mm, and 5 mm) with an intact medial collateral ligament (MCL 3-6) and following transection of the MCL (7-10). The radiographic measurement method according to Athwal et al. was evaluated to detect overlengthening. Statistical analysis included calculation of the diagnostic accuracy of the radiographic method. RESULTS: The radiographic measurement method correctly determined the size of the radial head prosthesis within ± 1 mm in 224 of 336 scenarios (67%) and within ± 2 mm in 320 of 336 scenarios (95%). With a threshold value of ≥ 1 mm, the overall diagnostic sensitivity for detecting overlengthening when it was present and was 90% and the specificity was 79%. The sensitivity was higher with increasing size of the prosthesis: in cases with overlengthening of 1.5 mm, the sensitivity was 76%, with an overlengthening of 3 mm, the sensitivity was 95%, and with an overlengthening of 5 mm, the sensitivity was 100%. CONCLUSION: The radiographic measurement method of Athwal et al. can be used to estimate and to diagnose the magnitude overlengthening of the MoPyC radial head prosthesis. However, the sensitivity is limited (76%) in cases with a small amount of overlengthening of 1.5 mm.


Asunto(s)
Articulación del Codo , Prótesis de Codo , Implantación de Prótesis , Radiografía , Radio (Anatomía) , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/cirugía , Humanos , Diseño de Prótesis , Implantación de Prótesis/métodos , Implantación de Prótesis/normas , Radiografía/métodos , Radiografía/normas , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/cirugía
15.
J Shoulder Elbow Surg ; 27(5): 839-845, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29292036

RESUMEN

BACKGROUND: This study analyzed the radiographic results of a cemented all-polyethylene keeled glenoid component available in different sizes and multiple backside radiuses of curvature. METHODS: The study group consisted of 118 cases (114 patients). There were 63 women and 51 men. Mean age at the time of arthroplasty was 68 years (range, 51-85 years). True anterior-posterior radiographs obtained postoperatively and at the final follow-up were analyzed for implant seating and the occurrence of radiolucent lines. Glenoid morphology and fatty infiltration of the rotator cuff muscles were examined using computed tomography scans. Mean follow-up was 38 months (range, 24-70 months). RESULTS: The mean radiolucent line score after surgery was 0.54 points (range, 0-3 points), and 90% had no or only 1 radiolucent line. At the final follow-up, the mean score was 1.06 points (range, 0-3 points), and 74% had no or only 1 radiolucent line. The score increased significantly over time (P < .001). No component was at risk for loosening. No correlation was found between patient age, sex, hand dominance, glenoid morphology, or fatty infiltration of the rotator cuff muscles and the occurrence of radiolucent lines. CONCLUSION: In the short-term, the glenoid component analyzed in this study showed promising radiographic results, with a low number of radiolucent lines without failure. However, the mean radiolucent line score increased significantly over time, and long-term observations are necessary to confirm a possible advantage compared with older component designs.


Asunto(s)
Artroplastía de Reemplazo de Hombro/métodos , Osteoartritis/cirugía , Polietileno , Articulación del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico , Diseño de Prótesis , Articulación del Hombro/diagnóstico por imagen , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
16.
J Digit Imaging ; 31(1): 74-83, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28799133

RESUMEN

Medical images are essential in modern traumatology and orthopedic surgery. Access to images is often cumbersome due to a limited number of workstations. Moreover, due to the tremendous increase of data, the time to review or to communicate images has also become limited. One approach to overcome these problems is to make use of modern mobile devices, like tablet computers, to facilitate image access and associated workflows. Ten orthopedic surgeons were equipped with an Apple iPad mini 2 and specialized viewing software for medical images. The surgeons were able to send images from a workstation onto the tablets or to search for patient images directly. The software enabled the physicians to share images, annotated key slices, and messages instantly with their colleagues. The surgeons carried the tablets within or in the periphery of the hospital. The participants evaluated the software by means of daily questionnaires. Data was collected for a period of 9 months. Nearly 25 images were viewed in total by the surgeons per day. The tablet viewer was used for accessing approximately 30% of these images. On average, the surgeons were asked 1.7 times per day by a colleague for a second opinion. They used the tablets in approximately 29% of these cases. Furthermore, the mean time for accessing images was significantly lower using mobile software compared to conventional methods. Tablet computers can play a vital role for image access and communication in the daily routine of an orthopedic surgeon. Mobile image access is an important aspect for surgeons, especially in larger facilities, to facilitate and accelerate the clinical workflows.


Asunto(s)
Computadoras de Mano , Cirujanos Ortopédicos , Ortopedia , Sistemas de Información Radiológica , Telerradiología/métodos , Humanos , Estudios Prospectivos
17.
Arch Orthop Trauma Surg ; 138(4): 487-493, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29322319

RESUMEN

INTRODUCTION: In operative treatment of distal radius fractures satisfying outcome mainly relies on anatomical fracture reduction and correct implant placement. Examination with two-dimensional fluoroscopy may not provide reliable information about this. The aim of this study was to determine the effectiveness of additional intraoperative three-dimensional imaging in the operative treatment of comminuted distal radius fractures. MATERIALS AND METHODS: From August 2001 to June 2015, patients with a distal radius fracture who were treated operatively and received intraoperative three-dimensional scan were included. The findings of the three-dimensional scan were documented by the operative surgeon and analyzed retrospectively with regard to incidence and the need for intraoperative revisions. Clinical evaluation included the patient's medical history, the injury pattern of the affected wrist (according to the OTA/AO fracture classification) and concomitant injuries. Intraoperative and postoperative complications and revision surgeries were evaluated as well. RESULTS: Of 4515 operatively treated distal radius fractures, 307 (6.8%) received additional intraoperative three-dimensional imaging during surgery. 263 of 307 patients (85.7%) had a distal radius fracture type C. Intraoperative three-dimensional imaging revealed findings in 125 patients (40.7%) that were not detected on conventional two-dimensional fluoroscopy. In 54 patients (17.6%) these findings led to an immediate revision. Most commonly, revision was done in the case of remaining steps in the articular surface ≥ 1 mm (n = 25, 8.1%) followed by intra-articular screw placement (n = 23, 7.5%). CONCLUSIONS: Intraoperative three-dimensional imaging can provide additional information compared to conventional two-dimensional fluoroscopy in the operative treatment of distal radius fractures with the possibility of immediate intraoperative revision.


Asunto(s)
Imagenología Tridimensional , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Humanos , Estudios Retrospectivos
18.
BMC Musculoskelet Disord ; 18(1): 85, 2017 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-28219360

RESUMEN

BACKGROUND: The primary objective of this study was to assess the interobserver and intraobserver agreement on ligamentous injuries on conventional magnetic resonance imaging (MRI) in acute simple elbow dislocation. The secondary objectives were to determine the interobserver agreement on the assessment of joint congruity, joint effusion, loose bodies and chondral lesions on conventional MRI. METHODS: Conventional MRIs (1.5 Tesla, elbow specific surface coil) of 30 patients (40.7 years; range 14-72) with simple elbow dislocations were evaluated by four blinded examiners. An analysis of the interobserver agreement of all raters and for several subgroups (radiologists, orthopaedics, experienced, non-experienced) was performed. The examiners assessed the integrity (intact, partial tear, complete tear) of the lateral collateral ligament (LCL), medial collateral ligament (MCL), extensor and flexor tendons, as well as the presence of joint congruity, joint effusion, loose bodies and chondral lesions. Agreement strength, correlation and proportion of exact agreement were determined for interobserver agreement, and intraobserver agreement analyses. RESULTS: Interobserver agreement of all examiners was fair to moderate for collateral ligaments (LCL: 0.441, MCL: 0.275). Exact agreement of all raters was found in 33.3% for the LCL and in 26.7% for the MCL. The both experienced examiners showed highest agreement strength for the LCL (0.619) and the radiologists showed highest agreement strength for the MCL (0.627), the proportion of exact agreement was 60.0% in both categories. A high proportion of exact agreement regarding joint congruity (90%), joint effusion (100%), loose bodies (96.7%) and chondral lesion (80%) was found among the radiologists. The evaluation of the intraobserver agreement revealed slight to substantial agreement (0.227 to 0.718) for the collateral ligaments. CONCLUSIONS: This study shows difficulties in the evaluation of ligaments by conventional MRI technique as demonstrated by a weak inter- and intraobserver agreement. This should be the basis to develop new MRI quality standards with special focus on coronal oblique reconstructions to improve the evaluation of ligament injuries after simple elbow dislocations.


Asunto(s)
Ligamentos Colaterales/diagnóstico por imagen , Ligamentos Colaterales/lesiones , Lesiones de Codo , Articulación del Codo/diagnóstico por imagen , Luxaciones Articulares/diagnóstico por imagen , Imagen por Resonancia Magnética/normas , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Rango del Movimiento Articular , Método Simple Ciego , Adulto Joven
19.
Arthroscopy ; 33(4): 819-827, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28043751

RESUMEN

PURPOSE: To evaluate the histologic and radiographic outcomes of using silicate-substituted calcium phosphate (Si-CaP) as bone graft substitute for the augmentation of tunnel defects in 2-stage revision anterior cruciate ligament (ACL) reconstruction. METHODS: Forty patients undergoing 2-stage revision ACL reconstruction were included in a prospective, randomized controlled clinical trial between 2012 and 2015. The inclusion criteria were tunnel diameter of the tibial and/or femoral tunnel of 10 mm or greater after failed ACL reconstruction. Twenty patients received autologous bone from the iliac crest and 20 patients received Si-CaP as a bone graft substitute for tunnel grafting at the first-stage procedure. Punch biopsy specimens of the augmented tunnels were taken at the second-stage procedure, and histologic examination included quantitative analysis of the area of immature bone formation, lamellar bone, and bone marrow. Radiographic analysis included determination of the filling rates of the tunnels on postoperative computed tomography scans. RESULTS: Forty patients with a mean age of 32 years (standard deviation [SD], 11.0 years) were analyzed. Histologic examination of the tunnels filled with Si-CaP showed that 15% (SD, 14%) of the area was covered with immature bone formation, 41% (SD, 10%) with well-organized lamellar bone, and 44% (SD, 8%) with bone marrow. In the control group (autologous bone), 58% (SD, 3%) of the area was covered with well-organized lamellar bone and 42% (SD, 3%) with bone marrow. Quantitative evaluation of the postoperative computed tomography scans showed a trend of better filling rates in patients with Si-CaP for the tibial tunnel (86% [SD, 17%] vs 78% [SD, 14%]; P = .131). Intraoperatively, Si-CaP was completely integrated into the original bone tunnel providing good stability for tunnel placement and tendon graft fixation comparable to autologous bone. CONCLUSIONS: Si-CaP as bone graft substitute for tunnel augmentation in 2-stage revision ACL reconstruction shows good histologic, radiographic, and intraoperative integration comparable to autologous bone. LEVEL OF EVIDENCE: Level I, prospective randomized controlled trial.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirugía , Sustitutos de Huesos/uso terapéutico , Trasplante Óseo/métodos , Fosfatos de Calcio/uso terapéutico , Adulto , Ligamento Cruzado Anterior/diagnóstico por imagen , Ligamento Cruzado Anterior/patología , Lesiones del Ligamento Cruzado Anterior/cirugía , Biopsia , Médula Ósea/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos , Reoperación/métodos , Silicatos/uso terapéutico , Tendones/trasplante , Tibia/diagnóstico por imagen , Tibia/cirugía , Tomografía Computarizada por Rayos X
20.
Knee Surg Sports Traumatol Arthrosc ; 25(7): 1995-2003, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27565482

RESUMEN

PURPOSE: Sports activity after surgical AC joint stabilisation has not been comprehensively evaluated to date. The aim of this study was to determine rate, level and time to return to sports after AC joint stabilisation and to identify the influence of overhead sports on post-operative sports activity. METHODS: In this retrospective case series, a total of 68 patients with a high-grade AC joint dislocation (Rockwood type V) were stabilised using a single TightRope technique. Fifty-five patients (80.9 %) with median age of 42.0 (range, 18-65) years completed questionnaires regarding sports activity before and after surgery. Clinical outcome and complications were also evaluated. Forty-three patients participated in sports regularly before injury. Their sports activity was rated according to Allain, and non-overhead and overhead sports were differentiated. RESULTS: At median follow-up of 24 (18-45) months, 41 of 43 patients (95.3 %) had returned to sports. 63 % returned to the same sports activity as before injury. 16.3 % needed to adapt the type of sports to reduce demanding activities. 11.6 % reduced the frequency and 32.5 % the intensity of sports. The median time to return to sports was 9.5 (3-18) months. Overhead athletes (Allain Type III and IV) had to reduce their sports activity significantly more often (11.8 vs. 53.8 %; p = 0.011) and needed more time to return to sports (9.5 vs. 4.5 months; p = 0.009). CONCLUSION: After stabilisation of AC joint dislocation, the majority of patients returned to sports after a substantial period of time. Overhead athletes, in particular, required more time and had to considerably reduce their sports activity. The findings impact therapeutic decision-making after AC joint injury and help with the prognosis and assessment of rehabilitation progress. LEVEL OF EVIDENCE: IV.


Asunto(s)
Articulación Acromioclavicular/lesiones , Luxaciones Articulares/cirugía , Dispositivos de Fijación Ortopédica , Procedimientos Ortopédicos/métodos , Volver al Deporte , Articulación Acromioclavicular/cirugía , Adolescente , Adulto , Anciano , Traumatismos en Atletas/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA