Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Synchrotron Radiat ; 30(Pt 5): 1013-1022, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37610343

RESUMEN

The BL09XU beamline of SPring-8 has been reorganized into a beamline dedicated for hard X-ray photoelectron spectroscopy (HAXPES) to provide advanced capabilities with upgraded optical instruments. The beamline has two HAXPES analyzers to cover a wide range of applications. Two sets of double channel-cut crystal monochromators with the Si(220) and (311) reflections were installed to perform resonant HAXPES analyses with a total energy resolution of less than 300 meV over a wide energy range (4.9-12 keV) while achieving a fixed-exit condition. A double-crystal X-ray phase retarder using diamond crystals controls the polarization state with a high degree of polarization over 0.9 in the wide energy range 5.9-9.5 keV. Each HAXPES analyzer is equipped with a focusing mirror to provide a high-flux microbeam. The design and performance of the upgraded instruments are presented.

2.
Opt Express ; 31(23): 38132-38145, 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-38017927

RESUMEN

X-ray focusing mirrors often employ the Kirkpatrick-Baez (KB) geometry, which sequentially crosses two elliptic-cylindrical mirrors in grazing-incidence configurations. However, KB mirrors do not satisfy the Abbe sine condition and thus potentially expand the focus size with severe coma aberration. Satisfying the Abbe sine condition complicates mirror shapes or increases the number of ultraprecision mirrors required. The present study shows that the focal length and mirror length of KB mirrors have to be shortened to simultaneously achieve a large numerical aperture and reduced aberration. Such ultracompact KB (ucKB) mirrors are examined using a simulation that combines ray tracing and wave propagation. The focus intensity distributions show that ucKB mirrors suppress the aberration produced by their rotation errors and that they robustly achieve diffraction-limited focusing. The simulation results are confirmed in a synchrotron radiation experiment. ucKB mirrors can be advantageous for soft-X-ray nanoprobes, which require focusing devices to achieve a large numerical aperture.

3.
J Synchrotron Radiat ; 29(Pt 5): 1265-1272, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36073886

RESUMEN

In this study, double-multilayer monochromators that generate intense, high-energy, pink X-ray beams are designed, installed and evaluated at the SPring-8 medium-length (215 m) bending-magnet beamline BL20B2 for imaging applications. Two pairs of W/B4C multilayer mirrors are designed to utilize photon energies of 110 keV and 40 keV with bandwidths of 0.8% and 4.8%, respectively, which are more than 100 times larger when compared with the Si double-crystal monochromator (DCM) with a bandwidth of less than 0.01%. At an experimental hutch located 210 m away from the source, a large and uniform beam of size 14 mm (V) × 300 mm (H) [21 mm (V) × 300 mm (H)] was generated with a high flux density of 1.6 × 109 photons s-1 mm-2 (6.9 × 1010 photons s-1 mm-2) at 110 keV (40 keV), which marked a 300 (190) times increase in the photon flux when compared with a DCM with Si 511 (111) diffraction. The intense pink beams facilitate advanced X-ray imaging for large-sized objects such as fossils, rocks, organs and electronic devices with high speed and high spatial resolution.


Asunto(s)
Fotones , Sincrotrones , Rayos X
4.
J Synchrotron Radiat ; 28(Pt 5): 1631-1638, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34475310

RESUMEN

An endstation dedicated to angle-resolved photoemission spectroscopy (ARPES) using a soft X-ray microbeam has been developed at the beamline BL25SU of SPring-8. To obtain a high photoemission intensity, this endstation is optimized for measurements under the condition of grazing beam incidence to a sample surface, where the glancing angle is 5° or smaller. A Wolter mirror is used for focusing the soft X-rays. Even at the glancing angle of 5°, the smallest beam spot still having a sufficient photon flux for ARPES is almost round on the sample surface and the FWHM diameter is ∼5 µm. There is no need to change the sample orientation for performing kx - ky mapping by virtue of the electron lens with a deflector of the photoelectron analyzer, which makes it possible to keep the irradiation area unchanged. A partially cleaved surface area as small as ∼20 µm was made on an Si(111) wafer and ARPES measurements were performed. The results are presented.

5.
J Synchrotron Radiat ; 27(Pt 5): 1103-1107, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876584

RESUMEN

A focusing optics that can provide a sub-micrometre high-flux probe for soft X-ray micrometre-scale angle-resolved photoemission spectroscopy (ARPES) is proposed. A monolithic Wolter-type mirror with a large acceptance, achromatism and small comatic aberration was designed and evaluated. A focused beam size of 0.4 µm (vertical) × 4 µm (horizontal), a high throughput of 59% and a high tolerance of 1.6 mrad to the pitching error were realized at a photon energy of 1000 eV. A Wolter-type mirror can be practically employed as a stable sub-micrometre focusing mirror with high throughput in ARPES applications.

6.
J Synchrotron Radiat ; 26(Pt 3): 756-761, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-31074440

RESUMEN

Probing the spatial coherence of X-rays has become increasingly important when designing advanced optical systems for beamlines at synchrotron radiation sources and free-electron lasers. Double-slit experiments at various slit widths are a typical method of quantitatively measuring the spatial coherence over a wide wavelength range including the X-ray region. However, this method cannot be used for the analysis of spatial coherence when the two evaluation points are separated by a large distance of the order of millimetres owing to the extremely narrow spacing between the interference fringes. A Fresnel-mirror-based optical system can produce interference patterns by crossing two beams from two small mirrors separated in the transverse direction to the X-ray beam. The fringe spacing can be controlled via the incidence angles on the mirrors. In this study, a Fresnel-mirror-based optical system was constructed at the soft X-ray beamline (BL25SU) of SPring-8. The relationship between the coherence and size of the virtual source was quantitatively measured at 300 eV in both the vertical and horizontal directions using the beam. The results obtained indicate that this is a valuable method for the optimization of optical systems along beamlines.

7.
J Synchrotron Radiat ; 25(Pt 5): 1444-1449, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30179184

RESUMEN

For the purpose of imaging element- and shell-specific magnetic distributions under high magnetic fields, a scanning soft X-ray microscope has been developed at beamline BL25SU, SPring-8, Japan. The scanning X-ray microscope utilizes total electron yield detection of absorbed circularly polarized soft X-rays in order to observe magnetic domains through the X-ray magnetic circular dichroism effect. Crucially, this system is equipped with an 8 T superconducting magnet. The performance and features of the present system are demonstrated by magnetic domain observations of the fractured surface of a Nd14.0Fe79.7Cu0.1B6.2 sintered magnet.

8.
J Synchrotron Radiat ; 25(Pt 1): 282-288, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29271777

RESUMEN

The design and performance of a soft X-ray free-electron laser (FEL) beamline of the SPring-8 Compact free-electron LAser (SACLA) are described. The SPring-8 Compact SASE Source test accelerator, a prototype machine of SACLA, was relocated to the SACLA undulator hall for dedicated use for the soft X-ray FEL beamline. Since the accelerator is operated independently of the SACLA main linac that drives the two hard X-ray beamlines, it is possible to produce both soft and hard X-ray FEL simultaneously. The FEL pulse energy reached 110 µJ at a wavelength of 12.4 nm (i.e. photon energy of 100 eV) with an electron beam energy of 780 MeV.

9.
J Synchrotron Radiat ; 23(1): 158-62, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26698058

RESUMEN

A combination of plane and threefold-shape X-ray mirrors was installed in SPring-8 BL29XUL. The second mirror has parabolic cylinder surfaces that collimate X-rays in the vertical direction. A performance test was conducted, yielding highly collimated 8 keV photon beams with an effective angular divergence of 0.4 µrad, below only 5% of that of the original beams. The double-mirror system preserved 70% of the total incident flux and nearly tripled the flux density at 988 m from the light source. The values of the observations were almost similar to those of our ray-tracing simulation. Based on the results a discussion of future prospects of the mirror system is included.

10.
J Synchrotron Radiat ; 21(Pt 2): 352-65, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24562556

RESUMEN

A new soft X-ray beamline, BL07LSU, has been constructed at SPring-8 to perform advanced soft X-ray spectroscopy for materials science. The beamline is designed to achieve high energy resolution (E/ΔE> 10000) and high photon flux [>10(12) photons s(-1) (0.01% bandwidth)(-1)] in the photon energy range 250-2000 eV with controllable polarization. To realise this state-of-the-art performance, a novel segmented cross undulator was developed and adopted as a light source. The details of the undulator light source and beamline monochromator design are described. The achieved performance of the beamline, such as the photon flux, energy resolution and the state of polarization, is reported.

11.
Nat Commun ; 15(1): 665, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38326328

RESUMEN

Nanoscale soft-X-ray microscopy is a powerful analysis tool in biological, chemical, and physical sciences. To enhance its probe sensitivity and leverage multimodal soft-X-ray microscopy, precise achromatic focusing devices, which are challenging to fabricate, are essential. Here, we develop an ultracompact Kirkpatrick-Baez (ucKB) mirror, which is ideal for the high-performance nanofocusing of broadband-energy X-rays. We apply our advanced fabrication techniques and short-focal-length strategy to realize diffraction-limited focusing over the entire soft-X-ray range. We achieve a focus size of 20.4 nm at 2 keV, which represents a significant improvement in achromatic soft-X-ray focusing. The ucKB mirror extends soft-X-ray fluorescence microscopy by producing a bicolor nanoprobe with a 1- or 2-keV photon energy. We propose a subcellular chemical mapping method that allows a comprehensive analysis of specimen morphology and the distribution of light elements and metal elements. ucKB mirrors will improve soft-X-ray nanoanalyses by facilitating photon-hungry, multimodal, and polychromatic methods, even with table-top X-ray sources.

12.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38240678

RESUMEN

Understanding the pressure-induced structural changes in liquids and amorphous materials is fundamental in a wide range of scientific fields. However, experimental investigation of the structure of liquid and amorphous material under in situ high-pressure conditions is still limited due to the experimental difficulties. In particular, the range of the momentum transfer (Q) in the structure factor [S(Q)] measurement under high-pressure conditions has been limited at relatively low Q, which makes it difficult to conduct detailed structural analysis of liquid and amorphous material. Here, we show the in situ high-pressure pair distribution function measurement of liquid and glass by using the 100 keV pink beam. Structures of liquids and glasses are measured under in situ high-pressure conditions in the Paris-Edinburgh press by high-energy x-ray diffraction measurement using a double-slit collimation setup with a point detector. The experiment enables us to measure S(Q) of GeO2 and SiO2 glasses and liquid Ge at a wide range of Q up to 20-29 Å-1 under in situ high-pressure and high-temperature conditions, which is almost two times larger than that of the conventional high-pressure angle-dispersive x-ray diffraction measurement. The high-pressure experimental S(Q) precisely determined at a wide range of Q opens the way to investigate detailed structural features of liquids and amorphous materials under in situ high-pressure and high-temperature conditions, as well as ambient pressure study.

13.
J Synchrotron Radiat ; 20(Pt 6): 910-3, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24121338

RESUMEN

SPring-8 BL41XU is a high-flux macromolecular crystallography beamline using an in-vacuum undulator as a light source. The X-rays are monochromated by a liquid-nitrogen-cooling Si double-crystal monochromator, and focused by Kirkpatrick-Baez mirror optics. The focused beam size at the sample is 80 µm (H) × 22 µm (V) with a photon flux of 1.1 × 10(13) photons s(-1). A pinhole aperture is used to collimate the beam in the range 10-50 µm. This high-flux beam with variable size provides opportunities not only for micro-crystallography but also for data collection effectively making use of crystal volume. The beamline also provides high-energy X-rays covering 20.6-35.4 keV which allows ultra-high-resolution data to be obtained and anomalous diffraction using the K-edge of Xe and I. Upgrade of BL41XU for more rapid and accurate data collection is proceeding. Here, details of BL41XU are given and an outline of the upgrade project is documented.

14.
Opt Express ; 21(13): 15382-8, 2013 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23842324

RESUMEN

We evaluated the ablation thresholds of optical materials by using hard X-ray free electron laser. A 1-µm-focused beam with 10-keV of photon energy from SPring-8 Angstrom Compact free electron LAser (SACLA) was irradiated onto silicon and SiO2 substrates, as well as the platinum and rhodium thin films on these substrates, which are widely used for optical materials such as X-ray mirrors. We designed and installed a dedicated experimental chamber for the irradiation experiments. For the silicon substrate irradiated at a high fluence, we observed strong mechanical cracking at the surface and a deep ablation hole with a straight side wall. We confirmed that the ablation thresholds of uncoated silicon and SiO2 substrates agree with the melting doses of these materials, while those of the substrates under the metal coating layer are significantly reduced. The ablation thresholds obtained here are useful criteria in designing optics for hard X-ray free electron lasers.

15.
Phys Rev Lett ; 111(19): 193001, 2013 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-24266469

RESUMEN

High-resolution O 1s resonant inelastic x-ray scattering spectra of liquid H2O, D2O, and HDO, obtained by excitation near the preedge resonance show, in the elastic line region, well-separated multiple vibrational structures corresponding to the internal OH stretch vibration in the ground state of water. The energy of the first-order vibrational excitation is strongly blueshifted with respect to the main band in the infrared or Raman spectra of water, indicating that water molecules with a highly weakened or broken donating hydrogen bond are correlated with the preedge structure in the x-ray absorption spectrum. The vibrational profile of preedge excited HDO water is well fitted with 50%±20% greater OH-stretch contribution compared to OD, which strongly supports a preference for OH being the weakened or broken H-bond in agreement with the well-known picture that D2O makes stronger H-bonds than H2O. Accompanying path-integral molecular dynamics simulations show that this is particularly the case for strongly asymmetrically H-bonded molecules, i.e., those that are selected by preedge excitation.

16.
Appl Opt ; 52(3): 509-15, 2013 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-23338201

RESUMEN

LiF crystal and film detectors were used to measure the far-field fluence profile of a self-amplified spontaneous-emission free-electron laser beam and diffraction imaging with high spatial resolution. In these measurements the photoluminescence (PL) response of LiF crystal and film was compared over a wide range of soft x-ray fluences. It was found that the soft x-ray fluence dependences of LiF crystal and film differ. At low fluence, the LiF crystal shows higher PL response compared to LiF film, while this comparison is the opposite at higher fluence. Accurate measurement of LiF crystal and film PL response is important for precise characterization of the spatial, spectral, and coherence features of x-ray beams across the full profile and in localized areas. For such measurements, crucial LiF detector attributes are high spatial resolution and high dynamic range.

17.
Rev Sci Instrum ; 94(1): 015106, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36725599

RESUMEN

Abrasive machining has been used for inner surface processing of various hollow components. In this study, we applied an in-air fluid jet as a precision machining method for the inner surface of an axisymmetric x-ray mirror whose inner diameter was less than 10 mm. We employed an abrasive with a polyurethane@silica core-shell structure, which has a low density of about 1.2 g/cm3 and a relatively large particle size of about 15 µm. By using this abrasive, a practical removal rate and a smooth machined surface were simultaneously obtained. We performed figure corrections for an axisymmetric mirror and improved the circumferential figure accuracy to a sub-10 nm root mean square level. To evaluate the machining performance in the longitudinal direction of the ellipsoidal surface, we also performed periodic figure fabrication on the inner surface of a 114 mm-long nickel ellipsoidal mirror. X-ray ptychography, an optical phase retrieval method, was also employed as a three-dimensional figure measurement technique of the mirror. The wavefield of the x-ray beam focused by the processed ellipsoidal mirror was observed with the ptychographic system at SPring-8, a synchrotron radiation facility. The retrieval calculations for the wavefront error confirmed that a sinusoidal waveform with a period of 12 mm was fabricated on the mirror surface. These experimental results suggest that a nanoscale figure fabrication cycle for the inner surface consisting of jet machining and wavefront measurement has been successfully constructed. We expect this technique to be utilized in the fabrication of error-free optical mirrors and various parts having hollow shapes.

18.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38081249

RESUMEN

This paper presents nanometer-scale production and metrology methods for elliptic-cylindrical x-ray mirrors with an unprecedentedly small tangential radius of curvature of 160 mm. Sub-millimeter-scale figure correction is conducted based on dynamic stencil deposition. The deposition flux through one or two shadow masks is examined by a comparison to a simple model. The masked deposition flux distribution is improved, leading to film thickness profiles that are 50 times sharper in terms of aspect ratio than those obtained using existing differential deposition approaches. Surface roughness deterioration is also effectively suppressed. A 2-mm-long 160-mm-radius mirror is produced with a width of 10 mm and measured using simple interferometry. The results are confirmed by conventional mirror metrology, contact profilometry, and x-ray ptychography. The x-ray focusing profile is diffraction-limited with a 142-nm focus size at a photon energy of 300 eV. The proposed methods have the potential to enhance the ultraprecise fabrication of highly curved mirrors, thus benefiting nanoscale photon-hungry x-ray techniques.

19.
Nat Commun ; 14(1): 7851, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38062025

RESUMEN

While polymorphism is prevalent in crystalline solids, polyamorphism draws increasing interest in various types of amorphous solids. Recent studies suggested that supercooling of liquid phase-change materials (PCMs) induces Peierls-like distortions in their local structures, underlying their liquid-liquid transitions before vitrification. However, the mechanism of how the vitrified phases undergo a possible polyamorphic transition remains elusive. Here, using high-energy synchrotron X-rays, we can access the precise pair distribution functions under high pressure and provide clear evidence that pressure can reverse the Peierls-like distortions, eliciting a polyamorphic transition in GeTe and GeSe. Combined with simulations based on machine-learned-neural-network potential, our structural analysis reveals a high-pressure state characterized by diminished Peierls-like distortion, greater coherence length, reduced compressibility, and a narrowing bandgap. Our finding underscores the crucial role of Peierls-like distortions in amorphous octahedral systems including PCMs. These distortions can be controlled through pressure and composition, offering potentials for designing properties in PCM-based devices.

20.
Phys Rev Lett ; 109(12): 127205, 2012 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-23005982

RESUMEN

CuFeO(2) is one of the multiferroic materials and is the first case that the electric polarization is not explained by the magnetostriction model or the spin-current model. We have studied this material using soft x-ray resonant diffraction and found that superlattice reflection 0 1-2q 0 appears in the ferroelectric and incommensurate magnetic ordered phase at the Fe L(2,3) absorption edges and moreover that the rotation of the x-ray polarization such as from σ to π or from π to σ is allowed at this reflection. These findings definitely provide direct evidence that the 3d t(2g↓) orbital state of Fe ions has a long-range order in the ferroelectric state. The spin-orbit interaction in Fe ions plays a crucial role to the ferroelectricity in CuFeO(2), coupling two nontrivial spin and orbital orders, both of which break the crystal symmetry.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA