Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Crit Rev Clin Lab Sci ; 60(7): 502-517, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37194676

RESUMEN

Quality control practices in the modern laboratory are the result of significant advances over the many years of the profession. Major advance in conventional internal quality control has undergone a philosophical shift from a focus solely on the statistical assessment of the probability of error identification to more recent thinking on the capability of the measurement procedure (e.g. sigma metrics), and most recently, the risk of harm to the patient (the probability of patient results being affected by an error or the number of patient results with unacceptable analytical quality). Nonetheless, conventional internal quality control strategies still face significant limitations, such as the lack of (proven) commutability of the material with patient samples, the frequency of episodic testing, and the impact of operational and financial costs, that cannot be overcome by statistical advances. In contrast, patient-based quality control has seen significant developments including algorithms that improve the detection of specific errors, parameter optimization approaches, systematic validation protocols, and advanced algorithms that require very low numbers of patient results while retaining sensitive error detection. Patient-based quality control will continue to improve with the development of new algorithms that reduce biological noise and improve analytical error detection. Patient-based quality control provides continuous and commutable information about the measurement procedure that cannot be easily replicated by conventional internal quality control. Most importantly, the use of patient-based quality control helps laboratories to improve their appreciation of the clinical impact of the laboratory results produced, bringing them closer to the patients.Laboratories are encouraged to implement patient-based quality control processes to overcome the limitations of conventional internal quality control practices. Regulatory changes to recognize the capability of patient-based quality approaches, as well as laboratory informatics advances, are required for this tool to be adopted more widely.

2.
Clin Chem Lab Med ; 61(10): 1808-1819, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37013650

RESUMEN

OBJECTIVES: Low-density lipoprotein cholesterol (LDLC) is the primary cholesterol target for the diagnosis and treatment of cardiovascular disease (CVD). Although beta-quantitation (BQ) is the gold standard to determine LDLC levels accurately, many clinical laboratories apply the Friedewald equation to calculate LDLC. As LDLC is an important risk factor for CVD, we evaluated the accuracy of Friedewald and alternative equations (Martin/Hopkins and Sampson) for LDLC. METHODS: We calculated LDLC based on three equations (Friedewald, Martin/Hopkins and Sampson) using the total cholesterol (TC), triglycerides (TG), and high-density lipoprotein cholesterol (HDLC) in commutable serum samples measured by clinical laboratories participating in the Health Sciences Authority (HSA) external quality assessment (EQA) programme over a 5 years period (number of datasets, n=345). LDLC calculated from the equations were comparatively evaluated against the reference values, determined from BQ-isotope dilution mass spectrometry (IDMS) with traceability to the International System of Units (SI). RESULTS: Among the three equations, Martin/Hopkins equation derived LDLC had the best linearity against direct measured (y=1.141x - 14.403; R2=0.8626) and traceable LDLC (y=1.1692x - 22.137; R2=0.9638). Martin/Hopkins equation (R2=0.9638) had the strongest R2 in association with traceable LDLC compared with the Friedewald (R2=0.9262) and Sampson (R2=0.9447) equation. The discordance with traceable LDLC was the lowest in Martin/Hopkins (median=-0.725%, IQR=6.914%) as compared to Friedewald (median=-4.094%, IQR=10.305%) and Sampson equation (median=-1.389%, IQR=9.972%). Martin/Hopkins was found to result in the lowest number of misclassifications, whereas Friedewald had the most numbers of misclassification. Samples with high TG, low HDLC and high LDLC had no misclassification by Martin/Hopkins equation, but Friedewald equation resulted in ∼50% misclassification in these samples. CONCLUSIONS: The Martin/Hopkins equation was found to achieve better agreement with the LDLC reference values as compared to Friedewald and Sampson equations, especially in samples with high TG and low HDLC. Martin/Hopkins derived LDLC also enabled a more accurate classification of LDLC levels.


Asunto(s)
Enfermedades Cardiovasculares , Humanos , LDL-Colesterol , Valores de Referencia , Triglicéridos , HDL-Colesterol , Enfermedades Cardiovasculares/diagnóstico
3.
Clin Chem Lab Med ; 61(5): 769-776, 2023 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-36420533

RESUMEN

Lot-to-lot verification is an integral component for monitoring the long-term stability of a measurement procedure. The practice is challenged by the resource requirements as well as uncertainty surrounding experimental design and statistical analysis that is optimal for individual laboratories, although guidance is becoming increasingly available. Collaborative verification efforts as well as application of patient-based monitoring are likely to further improve identification of any differences in performance in a relatively timely manner. Appropriate follow up actions of failed lot-to-lot verification is required and must balance potential disruptions to clinical services provided by the laboratory. Manufacturers need to increase transparency surrounding release criteria and work closer with laboratory professionals to ensure acceptable reagent lots are released to end users. A tripartite collaboration between regulatory bodies, manufacturers, and laboratory medicine professional bodies is key to developing a balanced system where regulatory, manufacturing, and clinical requirements of laboratory testing are met, to minimize differences between reagent lots and ensure patient safety. Clinical Chemistry and Laboratory Medicine has served as a fertile platform for advancing the discussion and practice of lot-to-lot verification in the past 60 years and will continue to be an advocate of this important topic for many more years to come.


Asunto(s)
Química Clínica , Juego de Reactivos para Diagnóstico , Humanos , Control de Calidad , Laboratorios
4.
Anal Bioanal Chem ; 415(5): 787-800, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36562812

RESUMEN

Urine albumin concentration and albumin-creatinine ratio are important for the screening of early-stage kidney damage. Commutable urine certified reference materials (CRMs) for albumin and creatinine are necessary for standardization of urine albumin and accurate measurement of albumin-urine ratio. Two urine CRMs for albumin and creatinine with certified values determined using higher-order reference measurement procedures were evaluated for their commutability on five brands/models of clinical analyzers where different reagent kits were used, including Roche Cobas c702, Roche Cobas c311, Siemens Atellica CH, Beckman Coulter AU5800, and Abbott Architect c16000. The commutability study was conducted by measuring at least 26 authentic patient urine samples and the human urine CRMs using both reference measurement procedures and the routine methods. Both the linear regression model suggested by the Clinical and Laboratory Standard Institute (CLSI) guidelines and log-transformed model recommended by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Commutability Working Group were used to evaluate the commutability of the human urine CRMs. The commutability of the human urine CRMs was found to be generally satisfactory on all five clinical analyzers for both albumin and creatinine, suggesting that they are suitable to be used routinely by clinical laboratories as quality control or for method validation of urine albumin and creatinine measurements.


Asunto(s)
Albúminas , Modelos Estadísticos , Humanos , Creatinina , Estándares de Referencia , Control de Calidad
5.
Clin Chem Lab Med ; 59(4): 711-720, 2021 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-33079695

RESUMEN

OBJECTIVES: Urine albumin is measured in clinical laboratories by immunoturbidimetry. However, large biases are observed among the different routine methods. To standardize the measurement of urine albumin, a reference measurement procedure (RMP) and urine albumin certified reference materials (CRMs) are needed. METHODS: A candidate RMP for urine albumin based on liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) using human serum albumin as calibration standard was developed. Isotope-labeled human albumin was used as internal standard. Urine samples were digested using trypsin and eight resulting "signature" peptides of albumin were quantified by LC-IDMS/MS. The candidate RMP was employed in value assignment of external quality assessment (EQA) samples and certification of urine albumin reference materials. The commutability of the developed CRMs was assessed against patient samples. RESULTS: The candidate RMP (recovery 101.5-103.2% and CV 1.2-3.3% at about 7-40 mg/L) met optimal performance goal. The lower limit of quantification was 0.03 mg/L as determined by signal-to-noise method. The EQA results from clinical laboratories using different immunoturbidimetric methods were generally comparable with assigned target values determined by the candidate RMP, with albumin concentrations ranging from 5 to 226 mg/L. Urine albumin reference materials (two levels) certified using the candidate RMP showed good commutability in a preliminary study. CONCLUSIONS: With optimal method precision and trueness, as well as comparability with routine methods, the developed RMP may be used for value assignment of EQA samples or certification of reference materials, which are important pillars in urine albumin method standardization.


Asunto(s)
Laboratorios Clínicos , Espectrometría de Masas en Tándem , Albúminas , Certificación , Cromatografía Liquida , Humanos , Isótopos , Estándares de Referencia
6.
Clin Chem Lab Med ; 57(5): 648-658, 2019 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-30543519

RESUMEN

Background The measurement of hemoglobin A1c (HbA1c) is important for diagnosing diabetes mellitus as well as assessing glycemic control in diabetic patients. Commutable whole blood certified reference materials (CRMs) are needed in the measurement of HbA1c for method validation and/or as quality controls. Methods We developed three levels of hemolyzed whole blood CRMs for HbA1c. The certified values were determined using liquid chromatography-isotope dilution tandem mass spectrometry method (LC-IDMS/MS) where two "signature" hexapeptides of HbA1c and hemoglobin A0 (HbA0) were used as the calibration standards. The concentrations of the hexapeptide solutions were determined by amino acid analysis by the LC-IDMS/MS method using amino acid CRMs as the calibration standards. The commutability study was conducted by measuring 25 patient specimens and the whole blood CRMs by both LC-IDMS/MS method and various routine methods using six different clinical analyzers. Results The certified values were determined to be 35.1±2.0, 50.3±1.9 and 65.8±2.6 mmol/mol, respectively. These CRMs showed good commutability on five of the six clinical analyzers but showed poor commutability on one of the clinical analyzers that used similar method as two other analyzers where good commutability was observed. Conclusions With certified target values based on metrological traceability and good commutability on most of the clinical analyzers, the developed whole blood CRMs can be used for method validation or as quality control materials in the measurement of HbA1c. The commutability study results also underscored the need of commutability testing of clinical CRMs using various clinical analyzers.


Asunto(s)
Hemoglobina Glucada/análisis , Análisis Químico de la Sangre/normas , Cromatografía Liquida , Hemoglobina Glucada/química , Humanos , Estabilidad Proteica , Estándares de Referencia , Espectrometría de Masas en Tándem
7.
Anal Bioanal Chem ; 411(28): 7519-7528, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31630222

RESUMEN

Testosterone in human serum is commonly tested in clinical laboratories using immunoassay methods as well as liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. To standardize and ensure the accuracy of the measurement results, reference procedures with higher metrological order are required. A simple measurement procedure based on one-step liquid-liquid extraction (LLE) and liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) was developed for total testosterone in human serum. The procedure involved serum spiked with 13C3-testosterone, equilibration for 2 h, and extraction with an organic solvent. Testosterone certified reference material (CRM) was used as the calibration standard to ensure the traceability to the International System of Units (SI). Testosterone in serum CRMs from the National Institute for Standards and Technology (NIST) and LGC were used to validate the accuracy of the newly developed method. The deviations of the obtained values from the NIST and LGC certified values ranged from -0.55% to 0.45%. Similarly, the coefficient of variations (CVs) of the replicate measurements were in the range of 0.55% and 0.78%, respectively. The relative expanded uncertainties were comparable with those of the certified materials. The newly developed LC-IDMS/MS procedure demonstrated adequate trueness and precision, and was simple to perform. The method can be used for value assignment of testosterone in external quality assessment (EQA) materials as well as certification of CRMs in the future. Graphical abstract.


Asunto(s)
Extracción Líquido-Líquido/métodos , Espectrometría de Masas en Tándem/métodos , Testosterona/sangre , Calibración , Cromatografía Liquida/métodos , Humanos , Técnicas de Dilución del Indicador , Isótopos , Estándares de Referencia , Reproducibilidad de los Resultados , Testosterona/normas , Incertidumbre
8.
J Clin Lab Anal ; 27(4): 272-6, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23852783

RESUMEN

BACKGROUND: Loop-mediated isothermal amplification (LAMP) assay has come forward as a rapid, cost-effective molecular technique for diagnosis of tuberculosis (TB) in developing countries. This study evaluated Mycobacterium tuberculosis-specific in-house LAMP assay targeting 16s rRNA and compared it with other conventional tests and nucleic acid amplification assay (IS6110 PCR). METHODS: A total of 133 sputum specimens (103 from suspected pulmonary TB cases and 30 from non-TB controls) were subjected to conventional tests, IS6110 PCR and 16s rRNA LAMP assay. RESULTS: Of the 103 patients, the maximum number of cases were found to be positive by LAMP assay, that is, in 87 (84.5%) patients, followed by culture positive in 78 (75.7%), IS6110 PCR in 74 (71.8%), and smear positive in 70 (67.9%) patients. Of the 83 smear positive and/or culture positive cases, LAMP detected 77 (92.77%) cases, and was found to be superior to IS6110 PCR, which could detect 69 (83.1%) cases; a concordance of 0.6 was obtained between the two tests using kappa statistics. CONCLUSION: Overall, LAMP was simple and efficacious for early diagnosis of smear positive, culture positive cases as well as for confirmation of smear negative, culture negative cases, and was found to be superior to IS6110 PCR.


Asunto(s)
Mycobacterium tuberculosis/genética , Técnicas de Amplificación de Ácido Nucleico/métodos , Esputo/microbiología , Tuberculosis Pulmonar/diagnóstico , Humanos , ARN Ribosómico 16S/genética
9.
Adv Clin Chem ; 115: 175-203, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37673520

RESUMEN

Delta check is an electronic error detection tool. It compares the difference in sequential results within a patient against a predefined limit, and when exceeded, the delta check rule is considered triggered. The patient results should be withheld for review and troubleshooting before releasing to the clinical team for patient management. Delta check was initially developed as a tool to detect wrong-blood-in-tube (sample misidentification) errors. It is now applied to detect errors more broadly within the total testing process. Recent advancements in the theoretical understanding of delta check has allowed for more precise application of this tool to achieve the desired clinical performance and operational set up. In this Chapter, we review the different pre-implementation considerations, the foundation concepts of delta check, the process of setting up key delta check parameters, performance verification and troubleshooting of a delta check flag.

10.
Ann Lab Med ; 43(1): 5-18, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36045052

RESUMEN

Background: Calibration is a critical component for the reliability, accuracy, and precision of mass spectrometry measurements. Optimal practice in the construction, evaluation, and implementation of a new calibration curve is often underappreciated. This systematic review examined how calibration practices are applied to liquid chromatography-tandem mass spectrometry measurement procedures. Methods: The electronic database PubMed was searched from the date of database inception to April 1, 2022. The search terms used were "calibration," "mass spectrometry," and "regression." Twenty-one articles were identified and included in this review, following evaluation of the titles, abstracts, full text, and reference lists of the search results. Results: The use of matrix-matched calibrators and stable isotope-labeled internal standards helps to mitigate the impact of matrix effects. A higher number of calibration standards or replicate measurements improves the mapping of the detector response and hence the accuracy and precision of the regression model. Constructing a calibration curve with each analytical batch recharacterizes the instrument detector but does not reduce the actual variability. The analytical response and measurand concentrations should be considered when constructing a calibration curve, along with subsequent use of quality controls to confirm assay performance. It is important to assess the linearity of the calibration curve by using actual experimental data and appropriate statistics. The heteroscedasticity of the calibration data should be investigated, and appropriate weighting should be applied during regression modeling. Conclusions: This review provides an outline and guidance for optimal calibration practices in clinical mass spectrometry laboratories.


Asunto(s)
Calibración , Cromatografía Liquida/métodos , Humanos , Espectrometría de Masas , Estándares de Referencia , Reproducibilidad de los Resultados
11.
Ann Acad Med Singap ; 52(1): 8-16, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36730801

RESUMEN

INTRODUCTION: Three doses of SARS-CoV-2 mRNA vaccines have been recommended for cancer patients to reduce the risk of severe disease. Anti-neoplastic treatment, such as chemotherapy, may affect long-term vaccine immunogenicity. METHOD: Patients with solid or haematological cancer were recruited from 2 hospitals between July 2021 and March 2022. Humoral response was evaluated using GenScript cPASS surrogate virus neutralisation assays. Clinical outcomes were obtained from medical records and national mandatory-reporting databases. RESULTS: A total of 273 patients were recruited, with 40 having haematological malignancies and the rest solid tumours. Among the participants, 204 (74.7%) were receiving active cancer therapy, including 98 (35.9%) undergoing systemic chemotherapy and the rest targeted therapy or immunotherapy. All patients were seronegative at baseline. Seroconversion rates after receiving 1, 2 and 3 doses of SARS-CoV-2 mRNA vaccination were 35.2%, 79.4% and 92.4%, respectively. After 3 doses, patients on active treatment for haematological malignancies had lower antibodies (57.3%±46.2) when compared to patients on immunotherapy (94.1%±9.56, P<0.05) and chemotherapy (92.8%±18.1, P<0.05). SARS-CoV-2 infection was reported in 77 (28.2%) patients, of which 18 were severe. No patient receiving a third dose within 90 days of the second dose experienced severe infection. CONCLUSION: This study demonstrates the benefit of early administration of the third dose among cancer patients.


Asunto(s)
COVID-19 , Neoplasias Hematológicas , Neoplasias , Humanos , SARS-CoV-2 , COVID-19/prevención & control , Resultado del Tratamiento , Neoplasias/tratamiento farmacológico , Vacunación , ARN Mensajero , Anticuerpos Antivirales , Inmunogenicidad Vacunal
12.
J Med Virol ; 84(3): 394-401, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22246824

RESUMEN

Genotyping for HIV drug resistance is costly and beyond the means for many Southeast Asian patients, who are self-funded. This prompted the development of a more cost-effective, in-house assay for an ethnically diverse, Southeast Asian population at the National University Hospital in Singapore, using Sanger-based sequencing. Plasma samples from 20 treatment-failure patients with a broad spectrum of HIV drug resistance mutations were used to validate this assay clinically. Blinded testing gave concordant results for 7/7 (100%) protease drug resistance-related mutations, including one major and six minor mutations, and 111/116 (95.7%) reverse-transcriptase (RT) drug resistance-related mutations, including 65 nucleoside RT inhibitors (NRTI) and 46 non-nucleoside RT inhibitors (NNRTI) mutations. There were five discordant results, involving three NRTI- and two NNRTI-resistance-associated mutations. Highly conserved primers designed to have a wide coverage of the HIV pol gene (covering the entire protease and 395 codons of the RT region) enabled efficient multi-ethnic population-based genotyping. Reagents for this in-house test cost around 60% less than those for commercially available assays (SGD150 vs. SGD350 per sample). In addition, this assay also identified mutations located within the C-terminal domain (codons 312-560) of RT that are beyond the reach of most published and commercial GRTs. Currently, most research on C-terminal drug-resistance-related mutations has been conducted on HIV subtype B infections. Therefore this assay enables further study of these C-terminal mutations in Southeast Asian populations, where there is a high prevalence of CRF01_AE and other non-subtype B HIV infections.


Asunto(s)
Fármacos Anti-VIH/farmacología , Técnicas de Genotipaje , VIH-1/efectos de los fármacos , VIH-1/genética , Mutación , Fármacos Anti-VIH/uso terapéutico , Pueblo Asiatico , Farmacorresistencia Viral/genética , Genotipo , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/virología , Proteasa del VIH/genética , Transcriptasa Inversa del VIH/genética , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Viral
14.
J Trace Elem Med Biol ; 68: 126825, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34391072

RESUMEN

BACKGROUND: A chloride test is an integral part of a basic metabolic panel that is essential for the assessment of a patient's acid-base and electrolyte status. While many methods are available commercially for the routine measurement of chloride, there is a need to address the accuracy and variability among the measurement results, especially with the prevalence of patients seeking treatment across different healthcare providers for alternative opinions. METHOD: A method based on sector field inductively coupled plasma isotope dilution mass spectrometry (SF-ICP-IDMS) was developed for the measurement of chloride in human serum. The SF-ICP-IDMS method was then used to assign the target values in the Health Sciences Authority (HSA) External Quality Assessment (EQA) Programme to evaluate the results of chloride test from participating clinical laboratories. RESULTS: The accuracy of the measurements was evaluated by comparing the results with the certified values of Electrolytes in Frozen Human Serum Certified Reference Materials (SRM 956c and SRM 956d) from the National Institute of Standards and Technology (NIST) at different chloride concentration levels. Over a five-year period from 2014-2018, the number of clinical laboratories which participated in the EQA Programme increased from 23 to 33. Comparison of robust means from the laboratories' results with our assigned target values revealed a reduction in relative deviation over time. The relationship between the deviation of each brand of clinical analysers and the chloride levels was established, where a larger deviation was uncovered at low chloride concentration. The SF-ICP-IDMS method was further demonstrated to be comparable with methods used by other metrology institutes in an international comparison organised by HSA under the auspice of the Consultative Committee for Amount of Substance - Metrology in Chemistry and Biology (CCQM). CONCLUSION: The use of metrologically traceable assigned target values enabled the study of method biasness from a small pool of dataset in each of the four brands of clinical analysers in HSA EQA Programme. This work underscores the need to improve the accuracy of chloride measurements by regular participation in an accuracy-based EQA Programme.


Asunto(s)
Cloruros , Laboratorios Clínicos , Electrólitos , Humanos , Técnicas de Dilución del Indicador , Estándares de Referencia
16.
Pathology ; 51(3): 281-285, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30803737

RESUMEN

We applied the indirect approach using anonymised data from an Australian and a Singapore laboratory to derive biological variation data for a group of 10 therapeutic drugs routinely monitored. A series of inclusion and exclusion criteria were applied on the data. The within- (CVi) and between-individual (CVg) biological variation data were then derived as previously described. The corresponding index of individuality and analytical performance specifications were also calculated. The biological variation data were overall very similar between the two study sites. Moreover, the biological variation data were also comparable between males and females, as well as whether the data originated from patients who only had two episodes of measurement during the study period or from the last two results from patients who had more than two episodes of measurement during the study period. The results presented in this study contribute towards the biological variation data for therapeutic drugs, which can be used to inform discussions about the setting of harmonised analytical performance specifications for these measurands.


Asunto(s)
Monitoreo de Drogas/métodos , Australia , Humanos , Laboratorios , Valores de Referencia , Singapur
20.
Clin Chim Acta ; 476: 103-106, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29175172

RESUMEN

Two sisters with hirsutism presented with mild hirsutism and isolated, grossly elevated (>34.9nmol/L) serum concentrations of androstenedione measured by competitive, homogeneous immunoassay. The clinically discordant laboratory results prompted us to look for assay interference. In this immunoassay, horseradish peroxidase (HRP)-conjugated androstenedione competes with endogenous androstenedione for binding with the solid-phase polyclonal rabbit IgG antibodies. After a wash step, the amount of signal generated by the bound HRP conjugate is inversely proportional to the androstenedione concentration. Alternative analysis by tandem mass spectrometry (a good first line option for troubleshooting) and repeating the competitive immunoassay after polyethylene glycol treatment returned androstenedione concentrations within reference limits. These findings suggested that the original result was spuriously elevated due to assay interference. Additionally, the patient samples were pre-incubated with heterophile blocking reagents, normal rabbit IgG antibodies and HRP-conjugated normal goat IgG antibodies, followed by repeat measurement using the immunoassay. Only samples pre-incubated with HRP-conjugate returned significantly lower androstenedione (9.5 and 12.5nmol/L, respectively), implying neutralisation of the interfering antibodies. Androstenedione remained grossly elevated in the other experiments. This deductive exercise showed that the interference is due to autoantibodies against the HRP label used in the immunoassay. Another immunoassay using HRP label (5α-dihydrotestosterone) also produced gross elevation that was normal by tandem mass spectrometry analysis. Assay interferences, though not uncommon, are frequently overlooked. Laboratory results discordant with clinical features should prompt consideration of assay interference to avoid unnecessary investigations and treatment. This is the first report of autoantibodies against the HRP label used in immunoassay.


Asunto(s)
Androstenodiona/aislamiento & purificación , Autoanticuerpos/inmunología , Hirsutismo/diagnóstico , Peroxidasa de Rábano Silvestre/inmunología , Inmunoensayo , Adolescente , Androstenodiona/sangre , Androstenodiona/inmunología , Autoanticuerpos/sangre , Niño , Femenino , Hirsutismo/sangre , Hirsutismo/inmunología , Peroxidasa de Rábano Silvestre/sangre , Peroxidasa de Rábano Silvestre/metabolismo , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA