Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Chin J Cancer Res ; 23(2): 129-33, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23482452

RESUMEN

OBJECTIVE: To evaluate the maximum tolerated dose (MTD) of docetaxel (DCT) and cisplatin (DDP) concurrently with three dimensional (3D) conformal radiotherapy or IMRT for patients with locally advanced non-small cell lung cancer (stage IIIa and IIIb) after 2-4 cycles of induction chemotherapy. METHODS: Fourteen patients with histological/cytological proven stage III non-small-cell lung cancer were eligible. 3D or IMRT radiotherapy (60-70Gy in 30-35 fractions, 6-7weeks, 2 Gy/fraction) was delivered concurrently with cisplatin and docetaxel, 2 cycles during concurrent chemoradiotherapy (CCRT). The level I dosage was composed of 56 mg/m(2) DCT, on day 1 and 28mg/m(2) DDP, on day 1 and day 2. The level II was composed of 60 mg/m(2) DCT, on day 1 and 30 mg/ m(2) DDP, on day 1 and day 2. The level III was composed of 64 mg/m(2) DCT, on day 1 and 32 mg/ m(2) DDP, on day 1 and day 2. RESULTS: Fourteen patients were allocated and finished concurrent chemoradiotherapy. The dose-limiting neutropenia was at the dose Level III (64 mg/m(2)) and occurred in 2 of 5 patients. No dose limiting non-hematologic or hematologic toxicity occurred in the other patients. CONCLUSIONS: Patients with locally advanced non-small cell lung cancer may tolerate 60mg/m(2) docetaxel and 60mg/m(2) cisplatin for 2 cycles during concurrent radiotherapy after 2-3 cycles of induction chemotherapy.

2.
Thorac Cancer ; 11(2): 362-368, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31808285

RESUMEN

BACKGROUND: The aim of this study was to explore whether spectral computed tomography (CT) imaging parameters are associated with PD-L1 expression of lung adenocarcinoma. METHODS: Spectral CT imaging parameters (iodine concentrations [IC] of lesion in arterial phase [ICLa] and venous phase [ICLv], normalized IC [NICa/NICv]-normalized to the IC in the aorta, slope of the spectral HU curve [λHUa/λHUv] and enhanced monochromatic CT number [CT40keVa/v, CT70keVa/v] on 40 and 70 keV images) were analyzed in 34 prospectively enrolled lung adenocarcinoma patients with common molecular pathological markers including PD-L1 expression detected with immunohistochemistry. Patients were divided into two groups: positive PD-L1 expression and negative PD-L1 expression groups. Two-sample Mann-Whitney U test was used to test the difference of spectral CT imaging parameters between the two groups. RESULTS: The CT40keVa (127.03 ± 37.92 vs. -54.69 ± 262.04), CT40keVv (124.39 ± 34.71 vs. -45.73 ± 238.97), CT70keVa (49.56 ± 11.76 vs. -136.51 ± 237.08) and CT70keVv (46.13 ± 15.81 vs. -133.10 ± 230.72) parameters in the positive PD-L1 expression group of lung adenocarcinoma were significantly higher than the negative PD-L1 expression group (all P < 0.05). There was no difference detected in IC, NIC and λHU of the arterial and venous phases between both groups (all P > 0.05). CONCLUSION: CT40keVa, CT40keVv, CT70keVa and CT70keVv were increased in positive PD-L1 expression. These parameters may be used to distinguish the PD-L1 expression state of lung adenocarcinoma.


Asunto(s)
Adenocarcinoma del Pulmón/patología , Antígeno B7-H1/metabolismo , Biomarcadores de Tumor/metabolismo , Neoplasias Pulmonares/patología , Tomografía Computarizada por Rayos X/métodos , Adenocarcinoma del Pulmón/diagnóstico por imagen , Adenocarcinoma del Pulmón/metabolismo , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/metabolismo , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos
3.
Zhonghua Zhong Liu Za Zhi ; 29(7): 545-8, 2007 Jul.
Artículo en Zh | MEDLINE | ID: mdl-18069640

RESUMEN

OBJECTIVE: To investigate the time of whole brain irradiation and the prognostic factors for non-small lung cancer patients with brain metastasis. METHODS: From August 1996 to December 2003, 147 patients with brain metastasis from non-small cell lung cancer received whole brain irradiation. The patients were divided into two groups: with or without symptoms caused by brain metastasis, each group was then divided into two sub-groups, early whole brain irradiation group (the interval between the diagnosis of brain metastasis and the brain irradiation < or = one month) and late group ( the interval > one month ). Univariate and multivariate analysis (Cox regression) as well as Kaplan-Meier method in SPSS software package 11.5 was used to analyze the data of the 147 patients including 72 with brain metastasis symptom and 75 without. RESULTS: The median survival time (MS) of patients with or without extracranial metastasis was 9.9 months and 11.3 months (P = 0.0002). Multivariate analysis indicated that extracranial metastasis was an independent prognostic factor (P = 0.0004). For 72 patients with brain metastasis symptom, the MS of the patients with and without extracranial metastasis was 9.3 months and 11.3 months (P = 0.0036). The MS of patients with early and late whole brain irradiation was 11.4 months and 9.2 months (P = 0.001). Multivariate analysis showed that extracranial metastasis, the interval between the diagnosis of brain metastasis and the whole brain irradiation were independent prognostic factors. However, for 75 patients without brain metastasis symptom, the MS difference of those with early or late whole brain irradiation was not statistically significant (P = 0.1643). CONCLUSION: The extracranial metastasis in non-small cell lung cancer patients with brain metastasis is an independent prognostic factors. Early whole brain irradiation may improve the survival for those with brain metastasis symptoms.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Irradiación Craneana , Neoplasias Pulmonares/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias Óseas/tratamiento farmacológico , Neoplasias Óseas/radioterapia , Neoplasias Óseas/secundario , Neoplasias Encefálicas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Pulmón de Células no Pequeñas/secundario , Terapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Modelos de Riesgos Proporcionales , Radioterapia de Alta Energía , Estudios Retrospectivos , Tasa de Supervivencia , Tiempo
4.
World J Gastroenterol ; 18(37): 5266-75, 2012 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-23066322

RESUMEN

AIM: To compare the volumetric-modulated arc therapy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning system: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (9F), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the planning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normalized to 95% of the PTV that received 100% of the prescribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different locations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1.1 and 2A 1.09). Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT. V20 (2A 21.49 Gy vs. 7F 24.59 Gy and 9F 24.16 Gy) and V30 (2A 9.73 Gy vs. 5F 12.61 Gy, 7F 11.5 Gy and 9F 11.37 Gy) of lungs in VMAT were lower than in c-IMRT, but low doses to lungs (V5 and V10) were increased. V30 (1A 48.12 Gy vs. 5F 59.2 Gy, 7F 58.59 Gy and 9F 57.2 Gy), V40 and V50 of heart in VMAT was lower than in c-IMRT. MUs in VMAT plans were significantly reduced in comparison with c-IMRT, maximum doses to the spinal cord and mean doses of lungs were similar between the two techniques. NTCP of spinal cord was 0 for all cases. NTCP of lungs and heart in VMAT were lower than in c-IMRT. The advantage of VMAT plan was enhanced by doubling the arc. CONCLUSION: Compared with c-IMRT, VMAT, especially the 2A, slightly improves the OAR dose sparing, such as lungs and heart, and reduces NTCP and MU with a better PTV coverage.


Asunto(s)
Neoplasias Esofágicas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo , Probabilidad , Oncología por Radiación/métodos , Radiometría/métodos , Dosificación Radioterapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA