Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Clin Microbiol ; 56(8)2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29793968

RESUMEN

Detection of acute HIV infection is critical for HIV public health and diagnostics. Clinical fourth-generation antigen (Ag)/antibody (Ab) combination (combo) and p24 Ag immunoassays have enhanced detection of acute infection compared to Ab-alone assays but require ongoing evaluation with currently circulating diverse subtypes. Genetically and geographically diverse HIV clinical isolates were used to assess clinical HIV diagnostic, blood screening, and next-generation assays. Three-hundred-member panels of 20 serially diluted well-characterized antibody-negative HIV isolates for which the researchers were blind to the results (blind panels) were distributed to manufacturers and end-user labs to assess the relative analytic sensitivity of currently approved and preapproved clinical HIV fourth-generation Ag/Ab combo or p24 Ag-alone immunoassays for the detection of diverse subtypes. The limits of detection (LODs) of virus were estimated for different subtypes relative to confirmed viral loads. Analysis of immunoassay sensitivity was benchmarked against confirmed viral load measurements on the blind panel. On the basis of the proportion of positive results on 300 observations, all Ag/Ab combo and standard sensitivity p24 Ag assays performed similarly and within half-log LODs, illustrating the similar breadth of reactivity and diagnostic utility. Ultrasensitive p24 Ag assays achieved dramatically increased sensitivities, while the rapid combo assays performed poorly. The similar performance of the different commercially available fourth-generation assays on diverse subtypes supports their use in broad geographic settings with locally circulating HIV clades and recombinant strains. Next-generation preclinical ultrasensitive p24 Ag assays achieved dramatically improved sensitivity, while rapid fourth-generation assays performed poorly for p24 Ag detection.


Asunto(s)
Serodiagnóstico del SIDA/métodos , Serodiagnóstico del SIDA/normas , Proteína p24 del Núcleo del VIH/sangre , Proteína p24 del Núcleo del VIH/inmunología , Infecciones por VIH/diagnóstico , VIH/aislamiento & purificación , Inmunoensayo/normas , Carga Viral/normas , Benchmarking , VIH/inmunología , Anticuerpos Anti-VIH/sangre , Antígenos VIH/sangre , Antígenos VIH/inmunología , Infecciones por VIH/sangre , Humanos , Límite de Detección , Sensibilidad y Especificidad
2.
J Clin Virol ; 91: 84-89, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28366544

RESUMEN

OBJECTIVE: FDA-approved antigen/antibody combo and HIV-1/2 differentiation supplemental tests do not have claims for dried blood spot (DBS) use. We compared two DBS-modified protocols, the Bio-Rad GS HIV Combo Ag/Ab (BRC) EIA and Geenius™ HIV-1/2 (Geenius) Supplemental Assay, to plasma protocols and evaluated them in the CDC/APHL HIV diagnostic algorithm. METHODS: BRC-DBS p24 analytical sensitivity was calculated from serial dilutions of p24. DBS specimens included 11 HIV-1 seroconverters, 151 HIV-1-positive individuals, including 20 on antiretroviral therapy, 31 HIV-2-positive and one HIV-1/HIV-2-positive individuals. BRC-reactive specimens were tested with Geenius using the same DBS eluate. Matched plasma specimens were tested with BRC, an IgG/IgM immunoassay and Geenius. DBS and plasma results were compared using the McNemar's test. A DBS-algorithm applied to 348 DBS from high-risk individuals who participated in surveillance was compared to HIV status based on local testing algorithms. RESULTS: BRC-DBS detects p24 at a concentration 18 times higher than in plasma. In seroconverters, BRC-DBS detected more infections than the IgG/IgM immunoassay in plasma (p=0.0133), but fewer infections than BRC-plasma (p=0.0133). In addition, the BRC/Geenius-plasma algorithm identified more HIV-1 infections than the BRC/Geenius-DBS algorithm (p=0.0455). The DBS protocols correctly identified HIV status for established HIV-1 infections, including those on therapy, HIV-2 infections, and surveillance specimens. CONCLUSIONS: The DBS protocols exhibited promising performance and allowed rapid supplemental testing. Although the DBS algorithm missed some early infections, it showed similar results when applied to specimens from a high-risk population. Implementation of a DBS algorithm would benefit testing programs without capacity for venipuncture.


Asunto(s)
Pruebas con Sangre Seca , Infecciones por VIH/diagnóstico , Técnicas para Inmunoenzimas , Serodiagnóstico del SIDA , Algoritmos , Pruebas con Sangre Seca/instrumentación , Pruebas con Sangre Seca/métodos , Monitoreo Epidemiológico , Anticuerpos Anti-VIH/sangre , Antígenos VIH/sangre , Antígenos VIH/inmunología , Infecciones por VIH/sangre , Infecciones por VIH/inmunología , Infecciones por VIH/virología , VIH-1/inmunología , VIH-2/inmunología , Humanos , ARN Viral/sangre , Juego de Reactivos para Diagnóstico , Factores de Riesgo , Sensibilidad y Especificidad
3.
J Clin Virol ; 58 Suppl 1: e79-84, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24342482

RESUMEN

BACKGROUND: A multisite study was conducted to evaluate the performance of the Bio-Rad 4th generation GS HIV Combo Ag/Ab EIA versus Abbott 4th generation ARCHITECT HIV Ag/Ab Combo. The performance of two 3rd generation EIAs, Ortho Diagnostics Anti-HIV 1+2 EIA and Siemens HIV 1/O/2 was also evaluated. OBJECTIVE: Study objective was comparison of analytical HIV-1 p24 antigen detection, sensitivity in HIV-1 seroconversion panels, specificity in blood donors and two HIV false reactive panels. STUDY DESIGN: Analytical sensitivity was evaluated with International HIV-1 p24 antigen standards, the AFFSAPS (pg/mL) and WHO 90/636 (IU/mL) standards; sensitivity in acute infection was compared on 55 seroconversion samples, and specificity was evaluated on 1000 negative blood donors and two false reactive panels. RESULTS: GS HIV Combo Ag/Ab demonstrated better analytical HIV antigen sensitivity compared to ARCHITECT HIV Ag/Ab Combo: 0.41 IU/mL versus 1.2 IU/mL (WHO) and 12.7 pg/mL versus 20.1 pg/mL (AFSSAPS); GS HIV Combo Ag/Ab EIA also demonstrated slightly better specificity compared to ARCHITECT HIV Ag/Ab Combo (100% versus 99.7%). The 4th generation HIV Combo tests detected seroconversion 7-11 days earlier than the 3rd generation HIV antibody only EIAs. CONCLUSION: Both 4th generation immunoassays demonstrated excellent performance in sensitivity, with the reduction of the serological window period (7-11 days earlier detection than the 3rd generation HIV tests). However, GS HIV Combo Ag/Ab demonstrated improved HIV antigen analytical sensitivity and slightly better specificity when compared to ARCHITECT HIV Ag/Ab Combo assay, with higher positive predictive values (PPV) for low prevalence populations.


Asunto(s)
Automatización de Laboratorios/métodos , Pruebas Diagnósticas de Rutina/métodos , Anticuerpos Anti-VIH/sangre , Antígenos VIH/sangre , Infecciones por VIH/diagnóstico , VIH-1/inmunología , Reacciones Falso Positivas , Humanos , Sensibilidad y Especificidad , Pruebas Serológicas/métodos
4.
J Clin Virol ; 52 Suppl 1: S57-61, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21995929

RESUMEN

BACKGROUND: A multi-center study was conducted to evaluate the Bio-Rad GS HIV Combo Ag/Ab EIA, a 4th generation HIV-1/HIV-2 assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma in adult and pediatric populations. OBJECTIVES: The objectives of the study were to assess assay performance for the detection of acute HIV infections; sensitivity in known HIV positive samples; percent agreement with HIV status; specificity in low and high risk individuals of unknown HIV status; and to compare assay performance to a 3rd generation HIV assay. STUDY DESIGN: The evaluation included testing 9150 samples at four U.S. clinical trial sites, using three kit lots. Unlinked samples were from routine testing, repositories or purchased from vendors. RESULTS: GS HIV Combo Ag/Ab EIA detection in samples from individuals in two separate populations with acute HIV infection was 95.2% (20/21) and 86.4% (38/44). Sensitivity was 100% (1603/1603) in known antibody positive [HIV-1 Groups M and O, and HIV-2] samples. HIV p24 antigen detection was 100% (53/53) in HIV-1 culture supernatants. HIV-1 seroconversion panel detection improved by a range of 0-20 days compared to a 3rd generation HIV test. Specificity was 99.9% (5989/5996) in low risk, 99.9% (959/960) in high risk and 100% (100/100) in pediatric populations. CONCLUSION: The GS HIV Combo Ag/Ab EIA significantly reduced the diagnostic window when compared to the 3rd generation screening assay, enabling earlier diagnosis of HIV infection. The performance parameters of the Bio-Rad GS HIV Combo Ag/Ab EIA are well suited for use in HIV diagnostic settings.


Asunto(s)
Anticuerpos Anti-VIH/análisis , Proteína p24 del Núcleo del VIH/análisis , Infecciones por VIH/diagnóstico , VIH-1/inmunología , VIH-2/inmunología , Técnicas para Inmunoenzimas/métodos , Anticuerpos Anti-VIH/sangre , Anticuerpos Anti-VIH/inmunología , Proteína p24 del Núcleo del VIH/sangre , Proteína p24 del Núcleo del VIH/inmunología , Infecciones por VIH/inmunología , Infecciones por VIH/virología , Seropositividad para VIH/diagnóstico , Seropositividad para VIH/inmunología , Seropositividad para VIH/virología , VIH-1/patogenicidad , VIH-2/patogenicidad , Humanos , Técnicas de Amplificación de Ácido Nucleico , Plasma/inmunología , Plasma/virología , Juego de Reactivos para Diagnóstico , Factores de Riesgo , Sensibilidad y Especificidad , Suero/inmunología , Suero/virología , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA