1.
Exp Physiol ; 107(11): 1225-1240, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35993480

RESUMEN

NEW FINDINGS: What is the central question of this study? Does the hyperbaric, hypercapnic, acidotic, hypoxic stress of apnoea diving lead to greater pulmonary vasoreactivity and increased right heart work in apnoea divers? What is the main finding and its importance? Compared with sex- and age-matched control subjects, divers experienced significantly less change in total pulmonary resistance in response to short-duration isocapnic hypoxia. With oral sildenafil (50 mg), there were no differences in total pulmonary resistance between groups, suggesting that divers can maintain normal pulmonary artery tone in hypoxic conditions. Blunted hypoxic pulmonary vasoconstriction might be beneficial during apnoea diving. ABSTRACT: Competitive apnoea divers dive repetitively to depths >50 m. During the final portions of ascent, divers experience significant hypoxaemia. Additionally, hyperbaria during diving increases thoracic blood volume while simultaneously reducing lung volume and increasing pulmonary artery pressure. We hypothesized that divers would have exaggerated hypoxic pulmonary vasoconstriction, leading to increased right heart work owing to their repetitive hypoxaemia and hyperbaria, and that the administration of sildenafil would have a greater effect in reducing pulmonary resistance in divers. We recruited 16 divers (Divers) and 16 age- and sex-matched non-diving control subjects (Controls). Using a double-blinded, placebo-controlled, cross-over design, participants were evaluated for normal cardiac and lung function, then their cardiopulmonary responses to 20-30 min of isocapnic hypoxia (end-tidal partial pressure of O2  = 50 mmHg) were measured 1 h after ingestion of 50 mg sildenafil or placebo. Cardiac structure and cardiopulmonary function were similar at baseline. With placebo, Divers had a significantly smaller increase in total pulmonary resistance than Controls after 20-30 min isocapnic hypoxia (change -3.85 ± 72.85 vs. 73.74 ± 91.06 dyns cm-5 , P = 0.0222). With sildenafil, Divers and Controls had similar blunted increases in total pulmonary resistance after 20-30 min of hypoxia. Divers also had a significantly lower systemic vascular resistance after sildenafil in normoxia. These data indicate that repetitive apnoea diving leads to a blunted hypoxic pulmonary vasoconstriction. We suggest that this is a beneficial adaption allowing for increased cardiac output with reduced right heart work and thus reducing cardiac oxygen utilization in hypoxaemic conditions.


Asunto(s)
Apnea , Vasoconstricción , Humanos , Hipoxia , Pulmón , Oxígeno , Citrato de Sildenafil , Método Doble Ciego , Estudios Cruzados
2.
Exp Physiol ; 106(4): 1120-1133, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33559974

RESUMEN

NEW FINDINGS: What is the central question of this study? How does deep breath-hold diving impact cardiopulmonary function, both acutely and over the subsequent 2.5 hours post-dive? What is the main finding and its importance? Breath-hold diving, to depths below residual volume, is associated with acute impairments in pulmonary gas exchange, which typically resolve within 2.5 hours. These data provide new insight into the behaviour of the lungs and pulmonary vasculature following deep diving. ABSTRACT: Breath-hold diving involves highly integrative and extreme physiological responses to both exercise and asphyxia during progressive elevations in hydrostatic pressure. Over two diving training camps (Study 1 and 2), 25 breath-hold divers (recreational to world-champion) performed 66 dives to 57 ± 20 m (range: 18-117 m). Using the deepest dive from each diver, temporal changes in cardiopulmonary function were assessed using non-invasive pulmonary gas exchange (indexed via the O2 deficit), ultrasound B-line scores, lung compliance and pulmonary haemodynamics at baseline and following the dive. Hydrostatically induced lung compression was quantified in Study 2, using spirometry and lung volume measurement, enabling each dive to be categorized by its residual volume (RV)-equivalent depth. From both studies, pulmonary gas exchange inefficiency - defined as an increase in O2 deficit - was related to the depth of the dive (r2  = 0.345; P < 0.001), with dives associated with lung squeeze symptoms exhibiting the greatest deficits. In Study 1, although B-lines doubled from baseline (P = 0.027), cardiac output and pulmonary artery systolic pressure were unchanged post-dive. In Study 2, dives with lung compression to ≤RV had higher O2 deficits at 9 min, compared to dives that did not exceed RV (24 ± 25 vs. 5 ± 8 mmHg; P = 0.021). The physiological significance of a small increase in estimated lung compliance post-dive (via decreased and increased/unaltered airway resistance and reactance, respectively) remains equivocal. Following deep dives, the current study highlights an integrated link between hydrostatically induced lung compression and transient impairments in pulmonary gas exchange efficiency.


Asunto(s)
Contencion de la Respiración , Intercambio Gaseoso Pulmonar , Gasto Cardíaco , Volumen Residual , Espirometría
3.
J Sci Med Sport ; 25(7): 553-556, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35466041

RESUMEN

OBJECTIVES: During apnea diving, a patent foramen ovale may function as a pressure relief valve under conditions of high pulmonary pressure, preserving left-ventricular output. Patent foramen ovale prevalence in apneic divers has not been previously reported. We aimed to determine the prevalence of patent foramen ovale in apneic divers compared to non-divers. DESIGN: Cross sectional. METHODS: Apnea divers were recruited from a training camp in Cavtat, Croatia and the diving community of Split, Croatia. Controls were recruited from the population of Split, Croatia and Eugene, Oregon, USA. Participants were instrumented with an intravenous catheter and underwent patent foramen ovale screening utilizing transthoracic saline contrast echocardiography. Appearance of microbubbles in the left heart within 3 cardiac cycles indicated the presence of patent foramen ovale. Lung function was measured with spirometry. Comparison of patent foramen ovale prevalence was conducted using chi-square analysis, p < .05. RESULTS: Apnea divers had a significantly higher prevalence of patent foramen ovale (19 of 36, 53%) compared to controls (9 of 36, 25%) (X2 (1, N = 72) = 5.844, p = .0156). CONCLUSIONS: Why patent foramen ovale prevalence is greater in apnea divers remains unknown, though hyperbaria during an apnea dive results in a translocation of blood volume centrally with a concomitant reduction in lung volume and alveolar hypoxia during ascent results in hypoxic pulmonary vasoconstriction. These conditions increase pulmonary arterial pressure, increasing right-atrial pressure allowing for right-to-left blood flow through a patent foramen ovale which may be beneficial for preserving cardiac output and reducing capillary hydrostatic forces.


Asunto(s)
Enfermedad de Descompresión , Buceo , Foramen Oval Permeable , Apnea/complicaciones , Contencion de la Respiración , Estudios Transversales , Enfermedad de Descompresión/complicaciones , Enfermedad de Descompresión/prevención & control , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/epidemiología , Humanos , Prevalencia
4.
Front Physiol ; 12: 639377, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34093221

RESUMEN

Breath-hold diving involves highly integrative physiology and extreme responses to both exercise and asphyxia during progressive elevations in hydrostatic pressure. With astonishing depth records exceeding 100 m, and up to 214 m on a single breath, the human capacity for deep breath-hold diving continues to refute expectations. The physiological challenges and responses occurring during a deep dive highlight the coordinated interplay of oxygen conservation, exercise economy, and hyperbaric management. In this review, the physiology of deep diving is portrayed as it occurs across the phases of a dive: the first 20 m; passive descent; maximal depth; ascent; last 10 m, and surfacing. The acute risks of diving (i.e., pulmonary barotrauma, nitrogen narcosis, and decompression sickness) and the potential long-term medical consequences to breath-hold diving are summarized, and an emphasis on future areas of research of this unique field of physiological adaptation are provided.

5.
J Appl Physiol (1985) ; 130(5): 1345-1350, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33600279

RESUMEN

In this case study, we evaluate the unique physiological profiles of two world-champion breath-hold divers. At close to current world-record depths, the extreme physiological responses to both exercise and asphyxia during progressive elevations in hydrostatic pressure are profound. As such, these professional athletes must be capable of managing such stress, to maintain performing at the forefront human capacity. In both divers, pulmonary function before and after deep dives to 102 m and 117 m in the open sea was assessed using noninvasive pulmonary gas exchange (indexed via the O2 deficit, which is analogous to the traditional alveolar to arterial oxygen difference), ultrasound B-line scores, airway resistance, and airway reactance. Hydrostatic-induced lung compression was also quantified via spirometry. Both divers successfully performed their dives. Pulmonary gas exchange efficiency was impaired in both divers at 10 min but had mostly restored within a few hours. Mild hemoptysis was transiently evident immediately following the 117-m dive, whereas both divers experienced nitrogen narcosis. Although B-lines were only elevated in one diver postdive, reductions in airway resistance and reactance occurred in both divers, suggesting that the compressive strain on the structural characteristics of the airways can persist for up to 3.5 h. Marked echocardiographic dyssynchrony was evident in one diver after 10 m of descent, which persisted until resolving at ∼77 m during ascent. In summary, despite the enormous hydrostatic and physiological stress to diving beyond 100 m on a single breath, these data provide valuable insight into the extraordinary capacity of those at the pinnacle of apneic performance.NEW & NOTEWORTHY This study shows that world-champion breath-hold divers demonstrate incredible tolerability to extreme levels of hydrostatic-induced lung compression. Immediately following dives to >100 m, there were acute impairments in pulmonary gas exchange efficiency, mild accummulation of extravascular lung fluid, noticable intrathoracic discomfort, and evident nitrogen narcosis, however, within a few hours, these had all mostly resolved.


Asunto(s)
Buceo , Contencion de la Respiración , Humanos , Oxígeno , Fenómenos Fisiológicos Respiratorios , Espirometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA