Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 120(9): e2220882120, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36802418

RESUMEN

Pathogens such as severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2), influenza, and rhinoviruses are transmitted by airborne aerosol respiratory particles that are exhaled by infectious subjects. We have previously reported that the emission of aerosol particles increases on average 132-fold from rest to maximal endurance exercise. The aims of this study are to first measure aerosol particle emission during an isokinetic resistance exercise at 80% of the maximal voluntary contraction until exhaustion, second to compare aerosol particle emission during a typical spinning class session versus a three-set resistance training session. Finally, we then used this data to calculate the risk of infection during endurance and resistance exercise sessions with different mitigation strategies. During a set of isokinetic resistance exercise, aerosol particle emission increased 10-fold from 5,400 ± 1,200 particles/min at rest to 59,000 ± 69,900 particles/min during a set of resistance exercise. We found that aerosol particle emission per minute is on average 4.9-times lower during a resistance training session than during a spinning class. Using this data, we determined that the simulated infection risk increase during an endurance exercise session was sixfold higher than during a resistance exercise session when assuming one infected participant in the class. Collectively, this data helps to select mitigation measures for indoor resistance and endurance exercise classes at times where the risk of aerosol-transmitted infectious disease with severe outcomes is high.


Asunto(s)
COVID-19 , Entrenamiento de Fuerza , Humanos , SARS-CoV-2 , COVID-19/prevención & control , Aerosoles y Gotitas Respiratorias , Ejercicio Físico
2.
Indoor Air ; 32(3): e13012, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35347787

RESUMEN

In this study, the risk of infection from SARS-CoV-2 Delta variant of passengers sharing a car cabin with an infected subject for a 30-min journey is estimated through an integrated approach combining a recently developed predictive emission-to-risk approach and a validated CFD numerical model numerically solved using the open-source OpenFOAM software. Different scenarios were investigated to evaluate the effect of the infected subject position within the car cabin, the airflow rate of the HVAC system, the HVAC ventilation mode, and the expiratory activity (breathing vs. speaking). The numerical simulations here performed reveal that the risk of infection is strongly influenced by several key parameters: As an example, under the same ventilation mode and emitting scenario, the risk of infection ranges from zero to roughly 50% as a function of the HVAC flow rate. The results obtained also demonstrate that (i) simplified zero-dimensional approaches limit proper evaluation of the risk in such confined spaces, conversely, (ii) CFD approaches are needed to investigate the complex fluid dynamics in similar indoor environments, and, thus, (iii) the risk of infection in indoor environments characterized by fixed seats can be in principle controlled by properly designing the flow patterns of the environment.


Asunto(s)
COVID-19 , Automóviles , COVID-19/etiología , Simulación por Computador , Humanos , Hidrodinámica , SARS-CoV-2
3.
Environ Res ; 201: 111487, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34116013

RESUMEN

BACKGROUND: There has been a notable increase in knowledge production on air pollution and human health. OBJECTIVE: To analyze the state of the art on the effects of air pollution on human health through a mapping review of existing systematic reviews and meta-analyses (SRs and MAs). METHODS: The systematic mapping review was based on the recommendations for this type of scientific approach in environmental sciences. The search was performed using PubMed, Web of Science, Scopus, Cinahl, and Cochrane Library databases, from their inception through June 2020. RESULTS: Among 3401 studies screened, 240 SRs and MAs satisfied the inclusion criteria. Five research questions were answered. There has been an overall progressive increase in publications since 2014. The majority of the SRs and MAs were carried out by researchers from institutions in China, the US, the UK, and Italy. Most studies performed a meta-analysis (161). In general, the reviews support the association of air pollution and health outcomes, and analyzed the effects of outdoor air pollution. The most commonly investigated health outcome type was the respiratory (mainly asthma and COPD), followed by cardiovascular outcomes (mainly stroke). Particulate matter (with a diameter of 2.5 µm (PM2.5) and 10 µm (PM10) or less) and nitrogen dioxide (NO2) were the most widely investigated pollutants in the reviews. The general population was the most common sample in the reviews, followed by children, and adults. The majority of the reviews investigated health outcomes of respiratory diseases in children, as well as cardiovascular diseases in all ages. Combining health outcomes and air pollutants, PM2.5 was included in a higher number of reviews in eight health outcomes, mainly cardiovascular diseases. DISCUSSION: The majority of SRs and MAs showed that air pollution has harmful effects on health, with a focus on respiratory and cardiovascular outcomes. Future studies should extend the analysis to psychological and social aspects influenced by air pollution.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Adulto , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/toxicidad , Contaminación del Aire/efectos adversos , Contaminación del Aire/análisis , Niño , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Humanos , Dióxido de Nitrógeno/análisis , Material Particulado/análisis , Material Particulado/toxicidad , Revisiones Sistemáticas como Asunto
4.
Indoor Air ; 31(1): 63-73, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32638396

RESUMEN

The new particle formation due to the use of cleaning products containing volatile organic compounds (VOCs) in indoor environments is well documented in the scientific literature. Indeed, the physical-chemical process occurring in particle nucleation due to VOC-ozone reactions was deepened as well as the effect of the main influencing parameters (ie, temperature, ozone). Nonetheless, proper quantification of the emission under actual meteo-climatic conditions and ozone concentrations is not available. To this end, in the present paper the emission factors of newly generated ultrafine particles due to the use of different floor cleaning products under actual temperature and relative humidity conditions and ozone concentrations typical of the summer periods were evaluated. Tests in a chamber and in an actual indoor environment were performed measuring continuously particle number concentrations and size distributions during cleaning activities. The tests revealed that a significant particle emission in the nucleation mode was present for half of the products under investigation with emission factors up to 1.1 × 1011 part./m2 (8.8 × 1010 part./mLproduct ), then leading to an overall particle emission comparable to other well-known indoor sources when cleaning wide surfaces.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Detergentes , Material Particulado/análisis , Ozono/análisis , Tamaño de la Partícula , Temperatura , Compuestos Orgánicos Volátiles/análisis
5.
Sensors (Basel) ; 20(23)2020 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-33255163

RESUMEN

In this work, we characterise the performance of a Sharp optical aerosol sensor model GP2Y1010AU0F. The sensor was exposed to different environments: to a clean room, to a controlled atmosphere with known aerosol size distribution and to the ambient atmosphere on a busy city street. During the exposure, the output waveforms of the sensor pulses were digitised, saved and a following offline analysis enabled us to study the behaviour of the sensor pulse-by-pulse. A linear response of the sensor on number concentration of the monosized dispersed PSL particles was shown together with an almost linear dependence on particle diameters in the 0.4 to 4 micrometer range. The gathered data about the sensor were used to predict its response to an ambient atmosphere, which was observed simultaneously with a calibrated optical particle counter.

6.
Toxicol Appl Pharmacol ; 278(1): 9-15, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24732441

RESUMEN

The objective of this study was to compare the short-term respiratory effects due to the inhalation of electronic and conventional tobacco cigarette-generated mainstream aerosols through the measurement of the exhaled nitric oxide (eNO). To this purpose, twenty-five smokers were asked to smoke a conventional cigarette and to vape an electronic cigarette (with and without nicotine), and an electronic cigarette without liquid (control session). Electronic and tobacco cigarette mainstream aerosols were characterized in terms of total particle number concentrations and size distributions. On the basis of the measured total particle number concentrations and size distributions, the average particle doses deposited in alveolar and tracheobronchial regions of the lungs for a single 2-s puff were also estimated considering a subject performing resting (sitting) activity. Total particle number concentrations in the mainstream resulted equal to 3.5±0.4×10(9), 5.1±0.1×10(9), and 3.1±0.6×10(9) part. cm(-3) for electronic cigarettes without nicotine, with nicotine, and for conventional cigarettes, respectively. The corresponding alveolar doses for a resting subject were estimated equal to 3.8×10(10), 5.2×10(10) and 2.3×10(10) particles. The mean eNO variations measured after each smoking/vaping session were equal to 3.2ppb, 2.7ppb and 2.8ppb for electronic cigarettes without nicotine, with nicotine, and for conventional cigarettes, respectively; whereas, negligible eNO changes were measured in the control session. Statistical tests performed on eNO data showed statistically significant differences between smoking/vaping sessions and the control session, thus confirming a similar effect on human airways whatever the cigarette smoked/vaped, the nicotine content, and the particle dose received.


Asunto(s)
Sistemas de Liberación de Medicamentos/instrumentación , Espiración , Pulmón/efectos de los fármacos , Óxido Nítrico/metabolismo , Material Particulado/efectos adversos , Fumar/efectos adversos , Productos de Tabaco/efectos adversos , Administración por Inhalación , Adulto , Aerosoles , Pruebas Respiratorias , Electrónica , Diseño de Equipo , Femenino , Humanos , Pulmón/metabolismo , Pulmón/fisiopatología , Masculino , Nicotina/administración & dosificación , Nicotina/efectos adversos , Agonistas Nicotínicos/administración & dosificación , Agonistas Nicotínicos/efectos adversos , Tamaño de la Partícula , Factores de Tiempo , Volatilización , Adulto Joven
7.
Ann Occup Hyg ; 58(7): 860-76, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24817159

RESUMEN

Adverse health effects caused by worker exposure to ultrafine particles have been detected in recent years. The scientific community focuses on the assessment of ultrafine aerosols in different microenvironments in order to determine the related worker exposure/dose levels. To this end, particle size distribution measurements have to be taken along with total particle number concentrations. The latter are obtainable through hand-held monitors. A portable particle size distribution analyzer (Nanoscan SMPS 3910, TSI Inc.) was recently commercialized, but so far no metrological assessment has been performed to characterize its performance with respect to well-established laboratory-based instruments such as the scanning mobility particle sizer (SMPS) spectrometer. The present paper compares the aerosol monitoring capability of the Nanoscan SMPS to the laboratory SMPS in order to evaluate whether the Nanoscan SMPS is suitable for field experiments designed to characterize particle exposure in different microenvironments. Tests were performed both in a Marple calm air chamber, where fresh diesel particulate matter and atomized dioctyl phthalate particles were monitored, and in microenvironments, where outdoor, urban, indoor aged, and indoor fresh aerosols were measured. Results show that the Nanoscan SMPS is able to properly measure the particle size distribution for each type of aerosol investigated, but it overestimates the total particle number concentration in the case of fresh aerosols. In particular, the test performed in the Marple chamber showed total concentrations up to twice those measured by the laboratory SMPS-likely because of the inability of the Nanoscan SMPS unipolar charger to properly charge aerosols made up of aggregated particles. Based on these findings, when field test exposure studies are conducted, the Nanoscan SMPS should be used in tandem with a condensation particle counter in order to verify and correct the particle size distribution data.


Asunto(s)
Monitoreo del Ambiente/instrumentación , Material Particulado/análisis , Análisis Espectral/instrumentación , Aerosoles/efectos adversos , Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Contaminantes Ocupacionales del Aire/análisis , Monitoreo del Ambiente/métodos , Humanos , Exposición por Inhalación/análisis , Tamaño de la Partícula , Material Particulado/efectos adversos
8.
Sci Rep ; 13(1): 18294, 2023 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-37880507

RESUMEN

The number of respiratory particles emitted during different respiratory activities is one of the main parameters affecting the airborne transmission of respiratory pathogens. Information on respiratory particle emission rates is mostly available for adults (few studies have investigated adolescents and children) and generally involves a limited number of subjects. In the present paper we attempted to reduce this knowledge gap by conducting an extensive experimental campaign to measure the emission of respiratory particles of more than 400 children aged 6 to 12 years while they pronounced a phonetically balanced word list at two different voice intensity levels ("speaking" and "loudly speaking"). Respiratory particle concentrations, particle distributions, and exhaled air flow rates were measured to estimate the respiratory particle emission rate. Sound pressure levels were also simultaneously measured. We found out that median respiratory particle emission rates for speaking and loudly speaking were 26 particles s-1 (range 7.1-93 particles s-1) and 41 particles s-1 (range 10-146 particles s-1), respectively. Children sex was significant for emission rates, with higher emission rates for males during both speaking and loudly speaking. No effect of age on the emission rates was identified. Concerning particle size distributions, for both respiratory activities, a main mode at approximately 0.6 µm and a second minor mode at < 2 µm were observed, and no differences were found between males and females. This information provides important input parameters in predictive models adopted to estimate the transmission risk of airborne pathogens in indoor spaces.


Asunto(s)
Contaminación del Aire Interior , Espiración , Masculino , Adulto , Femenino , Adolescente , Humanos , Niño , Tamaño de la Partícula
9.
Artículo en Inglés | MEDLINE | ID: mdl-36834200

RESUMEN

Atmospheric pollutants present environmental threats to health and have been investigated in different environments, such as highways, squares, parks, and gyms. These environments are frequented by older adults, who are considered fragile to the harmful impacts of pollution present in the air. The aim was to analyze the state of the art on the effects of air pollution on the health of older adults during physical activities (PAs) through a mapping review. The search was performed in PubMed, Web of Science, Scopus, and Cinahl databases until June 2022. Of the 10,109 studies initially identified, 58 met the inclusion criteria. The most investigated health outcome was cardiovascular disease, followed by respiratory outcomes. Particulate matter (PM2.5 and PM10), nitrogen dioxide (NO2), and ozone (O3) were the most investigated pollutants. Of the 75 health outcomes investigated, in 29, air pollution had harmful effects on the health of the older adults during the practice of PA, more frequently in cardiovascular diseases. In 25 outcomes, the beneficial effects of PA to the health of the older adults remained, despite exposure to high and low concentrations of pollutants, most often in terms of mental disorders. We conclude that poor air quality is a harmful factor for the health of older adults during the practice of PAs, more frequently in cardiovascular and respiratory diseases. On the other hand, for mental-health-related outcomes (depression and cognition), in most studies, the beneficial effects of PA in older adults were maintained, even after exposure to pollutants.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Enfermedades Cardiovasculares , Contaminantes Ambientales , Ozono , Humanos , Anciano , Contaminantes Atmosféricos/análisis , Exposición a Riesgos Ambientales/análisis , Contaminación del Aire/análisis , Material Particulado/análisis , Ozono/análisis , Dióxido de Nitrógeno/análisis
10.
Sci Total Environ ; 892: 164642, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37271394

RESUMEN

Characterizing the size distribution of airborne particles carrying SARS-CoV-2 virus is essential for understanding and predicting airborne transmission and spreading of COVID-19 disease in hospitals as well as public and home indoor settings. Nonetheless, few data are currently available on virus-laden particle size distribution. Thus, the aim of this study is reporting the total concentrations and size distributions of SARS-CoV-2- genetic material in airborne particles sampled in hospital and home environments. A nanoMOUDI R122 cascade impactor (TSI, USA) was used to collect size-segregated aerosol down to the sub-micron range in home and in three different hospital environments in presence of infected patients in order to provide the concentration of airborne SARS-CoV-2 genetic material for each particle size range at different sampling locations. Providing one of the largest datasets of detailed size-fractionated airborne SARS-CoV-2 RNA to date, we found that 45.2 % of the total sub- and super-micrometric fractions were positive for SARS-CoV-2 with its genetic material being present in 17.7 % of sub-micrometric (0.18-1 µm) and 81.9 % of super-micrometric (>1 µm) fractions. The highest concentration of SARS-CoV-2 genetic material in total suspended particles (5.6 ± 3.4 RNA copies m-3) was detected in the room occupied with patients with more severe COVID-19 symptoms collected during the patients' high flow nasal oxygen therapy. The highest concentration at certain particle size fraction strongly depends on the sampling environment. However, the contribution of SARS-CoV-2 genetic material was in favour of super-micrometric compared to sub-micrometric particle size range. The evaluation of the individual risk of infection was carried out on the basis of the obtained data considering a hypothetical exposure scenario. The obtained results indicate the necessity of the protective masks in presence of infected subjects, especially while staying for longer period of time in the hospital environments.


Asunto(s)
COVID-19 , Humanos , SARS-CoV-2/genética , ARN Viral , Aerosoles y Gotitas Respiratorias , Hospitales
11.
Sci Total Environ ; 827: 154288, 2022 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-35248635

RESUMEN

Pollutant emissions from residential heating systems represent a main concern in terms of outdoor air quality. Differently from other pollutants, sub-micron particle emission from heating systems has not yet been exhaustively characterized by the scientific literature, with limited data available, in particular, for gas-fueled boilers. In the present paper, an experimental campaign to measure the sub-micron particle number concentrations and distributions at the stack of different automatically-fed small-scale heating systems (conventional and condensing boilers fueled by natural gas and liquid petroleum gas, and pellet stoves) was performed. Based on the measured concentrations, corresponding emission rates and emission factors were also estimated. The results of the experimental campaign revealed that the highest concentrations were measured for pellet stoves (median value >107 part. m-3), whereas conventional (about 1 × 106 part. m-3) and condensing boilers (<106 part. m-3) presented much lower concentrations. No effect of the fuel (natural gas, liquid petroleum gas) on the total concentration measured at the stack of boilers was recognized, whereas a smaller distribution mode (at 10 nm) was measured for gas-fired boilers. Because of the particle concentration values, the highest particle emission rates and factors were the pellet stove ones (median values of 2.1 × 1015 part. h-1 and 8.4 × 1013 part. kWh-1, respectively), whereas emission rates for conventional and condensing boilers were about 5 × 1013 part. h-1 and 2 × 1013 part. h-1, respectively. The estimated emission factors were also adopted to perform a simplified evaluation of the relative contributions of the investigated automatically-fed small-scale heating systems in terms of particle number on a national scale (Italy): we obtained that the pellet stove contribution is the main one as it accounts for 87% of total emissions of particle number for heating purpose.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Contaminantes Ambientales , Petróleo , Contaminantes Atmosféricos/análisis , Contaminación del Aire/análisis , Calefacción , Gas Natural , Material Particulado/análisis
12.
Sci Total Environ ; 816: 151499, 2022 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-34752865

RESUMEN

The Delta variant of SARS-CoV-2 causes higher viral loads in infected hosts, increasing the risk of close proximity airborne transmission through breathing, speaking and coughing. We performed a Monte Carlo simulation using a social contact network and exponential dose-response model to quantify the close proximity reproduction number of both wild-type SARS-CoV-2 and the Delta variant. We estimate more than twice as many Delta variant cases will reproduce infection in their close proximity contacts (64%) versus the wild-type SARS-CoV-2 (29%). Occupational health guidelines must consider close proximity airborne transmission and recommend improved personal respiratory protection for high-risk workers.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos
13.
Nat Rev Phys ; 4(11): 723-734, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36065441

RESUMEN

Given that breathing is one of the most fundamental physiological functions, there is an urgent need to broaden our understanding of the fluid dynamics that governs it. There would be many benefits from doing so, including a better assessment of respiratory health, a basis for more precise delivery of pharmaceutical drugs for treatment, and the understanding and potential minimization of respiratory infection transmission. We review the physics of particle generation in the respiratory tract, the fate of these particles in the air on exhalation and the physics of particle inhalation. The main focus is on evidence from experimental studies. We conclude that although there is qualitative understanding of the generation of particles in the respiratory tract, a basic quantitative knowledge of the characteristics of the particles emitted during respiratory activities and their fate after emission, and a theoretical understanding of particle deposition during inhalation, nevertheless the general understanding of the entire process is rudimentary, and many open questions remain.

14.
Front Public Health ; 10: 1087087, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36568748

RESUMEN

Introduction: While increasing the ventilation rate is an important measure to remove inhalable virus-laden respiratory particles and lower the risk of infection, direct validation in schools with population-based studies is far from definitive. Methods: We investigated the strength of association between ventilation and SARS-CoV-2 transmission reported among the students of Italy's Marche region in more than 10,000 classrooms, of which 316 were equipped with mechanical ventilation. We used ordinary and logistic regression models to explore the relative risk associated with the exposure of students in classrooms. Results and discussion: For classrooms equipped with mechanical ventilation systems, the relative risk of infection of students decreased at least by 74% compared with a classroom with only natural ventilation, reaching values of at least 80% for ventilation rates >10 L s-1 student-1. From the regression analysis we obtained a relative risk reduction in the range 12%15% for each additional unit of ventilation rate per person. The results also allowed to validate a recently developed predictive theoretical approach able to estimate the SARS-CoV-2 risk of infection of susceptible individuals via the airborne transmission route. We need mechanical ventilation systems to protect students in classrooms from airborne transmission; the protection is greater if ventilation rates higher than the rate needed to ensure indoor air quality (>10 L s-1 student-1) are adopted. The excellent agreement between the results from the retrospective cohort study and the outcome of the predictive theoretical approach makes it possible to assess the risk of airborne transmission for any indoor environment.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/epidemiología , Estudios Retrospectivos , Aerosoles y Gotitas Respiratorias , Instituciones Académicas , Italia/epidemiología
15.
Geosci Front ; 13(6): 101285, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38620948

RESUMEN

The infectious emission rate is a fundamental input parameter for airborne transmission risk assessment, but data are limited due to reliance on estimates from chance superspreading events. This study assesses the strength of a predictive estimation approach developed by the authors for SARS-CoV-2 and uses novel estimates to compare the contagiousness of respiratory pathogens. We applied the approach to SARS-CoV-1, SARS-CoV-2, MERS, measles virus, adenovirus, rhinovirus, coxsackievirus, seasonal influenza virus and Mycobacterium tuberculosis (TB) and compared quanta emission rate (ERq) estimates to literature values. We calculated infection risk in a prototypical classroom and barracks to assess the relative ability of ventilation to mitigate airborne transmission. Our median standing and speaking ERq estimate for SARS-CoV-2 (2.7 quanta h-1) is similar to active, untreated TB (3.1 quanta h-1), higher than seasonal influenza (0.17 quanta h-1), and lower than measles virus (15 quanta h-1). We calculated event reproduction numbers above 1 for SARS-CoV-2, measles virus, and untreated TB in both the classroom and barracks for an activity level of standing and speaking at low, medium and high ventilation rates of 2.3, 6.6 and 14 L per second per person (L s-1 p-1), respectively. Our predictive ERq estimates are consistent with the range of values reported over decades of research. In congregate settings, current ventilation standards are unlikely to control the spread of viruses with upper quartile ERq values above 10 quanta h-1, such as SARS-CoV-2, indicating the need for additional control measures.

16.
Sci Total Environ ; 818: 151756, 2022 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-34822884

RESUMEN

This study is the first study that reports the cluster particle (1-3 nm) formation (CPF) in two modern preschools located in Nur-Sultan city of Kazakhstan from October 28 to November 27, 2019. The average particle number concentration and mode diameter values during major CPF events in Preschool I and Preschool II were found to be 1.90 × 106 (SD 6.43 × 106) particles/cm3 and 1.60 (SD 0.85) nm, and 1.11 × 109 (SD 5.46 × 109) particles/cm3 and 2.16 (SD 1.47) nm, respectively. The ultraviolet PM concentration reached as high as 7 µg/m3 in one of the measurement days. The estimated emission rate in Preschool I for CPF events was 9.57 × 109 (SD 1.92 × 109) particles/min. For Preschool II, the emission rate was 7.25 × 109 (SD 12.4 × 109) particles/min. We identified primary cluster particles (CPs) emitted directly from the sources such as candle burning, and secondary CPs formed as a result of the oxidation of indoor VOCs or smoking VOCs. The secondary CPs are likely to be SOA. Indoor VOCs were mainly emitted during cleaning activities as well as during painting and gluing. Indoor VOCs are the controlling factors in the CPF events. Changes in the training and cleaning programs may result in significant reductions in the exposure of the children to CPs.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Niño , Preescolar , Humanos , Tamaño de la Partícula , Material Particulado/análisis , Instituciones Académicas
17.
Environ Int ; 147: 106326, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33340987

RESUMEN

Given the widespread concern but general lack of information over the possibility of SARS-CoV-2 infection in public transport, key issues such as passenger personal hygiene, efficient air circulation systems, and the effective disinfection of frequently touched surfaces need to be evaluated to educate the public and diminish the risk of viral transmission as we learn to live with the ongoing pandemic. In this context we report on a study involving the collection of 99 samples taken from inside Barcelona buses and subway trains in May to July 2020. From this sample group 82 (58 surface swabs, 9 air conditioning (a/c) filters, 3 a/c dust, 12 ambient air) were selected to be analysed by RT-PCR for traces of the SARS-CoV-2 virus. Thirty of these selected samples showed evidence for one or more of 3 target RNA gene regions specific for this virus (IP2, IP4, E). Most (24) of these 30 samples showed positivity for only 1 of the 3 RNA targets, 4 samples yielded 2 targets, and 2 samples provided evidence for all 3 targets. RNA remnants were more common in surface swabs from support bars (23 out of 58) than in ambient air inside the vehicles (3 out of 12), with relatively higher concentrations of viral RNA fragments in buses rather than in trains. Whereas subway train a/c filters examined were all virus-free, 4 of the 9 bus a/c filter/dust samples yielded evidence for viral RNA. After nocturnal maintenance and cleaning most buses initially yielding positive results subsequently showed elimination of the RT-PCR signal, although signs of viral RNA remained in 4 of 13 initially positive samples. The presence of such remnant viral traces however does not demonstrate infectivity, which in the present study is considered unlikely given the fragmentary nature of the gene targets detected. Nevertheless, best practice demands that close attention to ventilation systems and regular vehicle disinfection in public transport worldwide need to be rigorously applied to be effective at eliminating traces of the virus throughout the vehicle, especially at times when COVID-19 cases are peaking. Additionally, infectivity tests should be implemented to evaluate the efficiency of disinfection procedures to complement the information resulting from RT-PCR analysis. Modelling the probability of infection whilst travelling in buses under different scenarios indicates that forced ventilation greatly reduces the risk.


Asunto(s)
COVID-19 , Vías Férreas , Humanos , Vehículos a Motor , Pandemias , ARN Viral , SARS-CoV-2
18.
Environ Pollut ; 269: 116229, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-33321310

RESUMEN

In the present study, the daily dose in terms of particle surface area received by citizens living in different low- and middle-income countries, characterized by different lifestyles, habits, and climates, was evaluated. The level of exposure to submicron particles and the dose received by the populations of Accra (Ghana), Cairo (Egypt), Florianopolis (Brazil), and Nur-Sultan (Kazakhstan) were analyzed. A direct exposure assessment approach was adopted to measure the submicron particle concentration levels of volunteers at a personal scale during their daily activities. Non-smoking adult volunteers performing non-industrial jobs were considered. Exposure data were combined with time-activity pattern data (characteristic of each population) and the inhalation rates to estimate the daily dose in terms of particle surface area. The received dose of the populations under investigation varied from 450 mm2 (Florianopolis, Brazil) to 1300 mm2 (Cairo, Egypt). This work highlights the different contributions of the microenvironments to the daily dose with respect to high-income western populations. It was evident that the contribution of the Cooking & Eating microenvironment to the total exposure (which was previously proven to be one of the main exposure routes for western populations) was only 8%-14% for low- and middle-income populations. In contrast, significant contributions were estimated for Outdoor day and Transport microenvironments (up to 20% for Cairo, Egypt) and the Sleeping & Resting microenvironment (up to 28% for Accra, Ghana), highlighting the effects of different site-specific lifestyles (e.g. time-activity patterns), habits, socioeconomic conditions, climates, and outdoor air quality.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Adulto , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Brasil , Países en Desarrollo , Egipto , Monitoreo del Ambiente , Ghana , Humanos , Kazajstán , Tamaño de la Partícula , Material Particulado/análisis
19.
Environ Pollut ; 266(Pt 2): 115209, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32688075

RESUMEN

In everyday life, people are exposed to different concentrations of airborne particles depending on the microenvironment where they perform their different activities. Such exposure can lead to high sub-micron particle doses. The received dose depends on particle concentration to which people are exposed (typically expressed in terms of number or surface area), time spent in each activity or microenvironment (time activity pattern) and amount of air inhaled (inhalation rate). To estimate an actual value of the received dose, all these parameters should be measured under real-life conditions; in fact, the concentrations should be measured on a personal scale (i.e. through a direct exposure assessment), whereas time activity patterns and inhalation rates specific to the activity performed should be considered. The difficulties in obtaining direct measurements of these parameters usually lead to adopt time activity patterns and inhalation rates already available in scientific literature for typical populations, and local outdoor particle concentrations measured with fixed monitoring stations and extrapolated for all the other microenvironments. To overcome these limitations, we propose a full-field method for estimating the received dose of a population sample, in which all the parameters (concentration levels, time activity patterns and inhalation rates) are measured under real-life conditions (also including the inhalation rates, that were evaluated on the basis of the measured heart rates). Specifically, 34 volunteers were continuously monitored for seven days and the data of sub-micron particle concentrations, activities performed, and inhalation rates were recorded. The received dose was calculated with the proposed method and compared with those obtained from different simplified methodologies that consider typical data of particle concentrations, time activity patterns and inhalation rates obtained from literature. The results show that, depending on the methodology used, the differences in the received daily dose can be significant, with a general underestimation of the most simplified method.


Asunto(s)
Contaminantes Atmosféricos/análisis , Monitoreo del Ambiente , Humanos , Exposición por Inhalación/análisis , Tamaño de la Partícula , Material Particulado/análisis
20.
Artículo en Inglés | MEDLINE | ID: mdl-32069790

RESUMEN

One of the most important functions of air conditioning systems in operating rooms is to protect occupants against pathogenic agents transported by air. This protection is done by simultaneously controlling the air distribution, temperature, humidity, filtration and infiltration from other areas etc. Due to their low price, simple installation, operation and maintenance, window/wall air conditioning system have largely been used in operating rooms in Brazil, even if these types of equipment only recirculate the air inside the room without appropriate filtration and renovation with outdoor air. In this context, this work aims to analyse the performance of the window/wall air conditioning systems on indoor air ventilation in operating rooms by measuring particle number concentrations and carbon dioxide concentrations during different surgical procedures, in a single surgical room and in the nearby areas (corridor) for two cases: single surgery and two subsequent surgeries. In addition, the efficiency of the analysed air conditioning system was evaluated by comparing the ventilation level calculated in the surgical room with the ventilation required in order to maintain the carbon dioxide concentration within acceptable levels. The results showed that this type of air conditioning system is not appropriate for use in operating rooms since it cannot provide an adequate level of ventilation. The CO2 concentrations during surgeries, in fact, significantly exceeded acceptable values and a simultaneous increase in particle number concentration was observed. The results also showed that there is a high risk of contamination between subsequent surgeries in the same surgical room, due to residues of contaminants transported by the particles emitted during the surgeries that were not removed from the operating room by the air conditioning system. The particle number concentration measured in the second surgery, in fact, was approximately six times higher than in the first surgery.


Asunto(s)
Aire Acondicionado , Contaminación del Aire Interior , Dióxido de Carbono , Quirófanos , Material Particulado , Contaminación del Aire Interior/análisis , Brasil , Dióxido de Carbono/análisis , Material Particulado/análisis , Ventilación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA