Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Histopathology ; 74(3): 504-513, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30239030

RESUMEN

AIM: Primary cutaneous neuroendocrine carcinoma, or Merkel cell carcinoma (MCC), cannot be distinguished morphologically from small-cell neuroendocrine carcinomas (SmCC) from other sites. Immunohistochemistry is required to confirm cutaneous origin, and is also used for detection of sentinel lymph node (SLN) metastases of MCC. Cytokeratin 20 (CK20) expression is commonly used for these purposes, but is negative in some MCC cases, and has unclear specificity. We evaluated immunohistochemistry for neurofilament and CK20 in MCC compared with SmCC from other sites. METHODS AND RESULTS: We evaluated neurofilament expression in 55 MCC specimens from 39 unique patients, including nine CK20-negative MCC tumours. Neurofilament expression was observed in 42 of 55 (76.4%) MCC cases, including seven of nine (77.8%) CK20-negative MCC cases. Neurofilament was expressed in nine of 12 (75%) Merkel cell polyomavirus-positive tumours and five of 10 (50%) virus-negative tumours. Compared to a standard immunohistochemical panel (cytokeratin cocktail and CK20), neurofilament was 87.5% sensitive for detecting SLN metastases. Neurofilament and CK20 expression was also assessed in 61 extracutaneous SmCC from 60 unique patients, with primary sites including lung (27), bladder (18), cervix (3), gastrointestinal tract (3), sinonasal tract (2) and other sites (7). The specificity of neurofilament and CK20 for MCC versus non-cutaneous SmCC was 96.7% and 59.0%, respectively. CONCLUSIONS: Neurofilament has superior specificity to CK20 in distinguishing MCC from non-cutaneous SmCC. Neurofilament is frequently expressed in CK20- and virus-negative MCC tumours. Limitations of neurofilament immunohistochemistry include lower sensitivity than CK20 and subtle staining in some tumours. However, our findings indicate that neurofilament is useful for excluding non-cutaneous SmCC.


Asunto(s)
Biomarcadores de Tumor/análisis , Carcinoma de Células de Merkel/diagnóstico , Filamentos Intermedios , Neoplasias Cutáneas/diagnóstico , Humanos , Inmunohistoquímica , Queratina-20/análisis , Sensibilidad y Especificidad
2.
Antioxidants (Basel) ; 11(8)2022 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-36009344

RESUMEN

We have previously shown in a murine model of Non-alcoholic Fatty Liver Disease (NAFLD) that chronic, low-dose exposure to the Harmful Algal Bloom cyanotoxin microcystin-LR (MC-LR), resulted in significant hepatotoxicity including micro-vesicular lipid accumulation, impaired toxin metabolism as well as dysregulation of the key signaling pathways involved in inflammation, immune response and oxidative stress. On this background we hypothesized that augmentation of hepatic drug metabolism pathways with targeted antioxidant therapies would improve MC-LR metabolism and reduce hepatic injury in NAFLD mice exposed to MC-LR. We chose N-acetylcysteine (NAC, 40 mM), a known antioxidant that augments the glutathione detoxification pathway and a novel peptide (pNaKtide, 25 mg/kg) which is targeted to interrupting a specific Src-kinase mediated pro-oxidant amplification mechanism. Histological analysis showed significant increase in hepatic inflammation in NAFLD mice exposed to MC-LR which was attenuated on treatment with both NAC and pNaKtide (both p ≤ 0.05). Oxidative stress, as measured by 8-OHDG levels in urine and protein carbonylation in liver sections, was also significantly downregulated upon treatment with both antioxidants after MC-LR exposure. Genetic analysis of key drug transporters including Abcb1a, Phase I enzyme-Cyp3a11 and Phase II metabolic enzymes-Pkm (Pyruvate kinase, muscle), Pklr (Pyruvate kinase, liver, and red blood cell) and Gad1 (Glutamic acid decarboxylase) was significantly altered by MC-LR exposure as compared to the non-exposed control group (all p ≤ 0.05). These changes were significantly attenuated with both pNaKtide and NAC treatment. These results suggest that MC-LR metabolism and detoxification is significantly impaired in the setting of NAFLD, and that these pathways can potentially be reversed with targeted antioxidant treatment.

3.
Arch Pathol Lab Med ; 141(11): 1490-1502, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29072946

RESUMEN

CONTEXT: - Basal cell carcinoma (BCC) is the most common human malignant neoplasm and is a frequently encountered diagnosis in dermatopathology. Although BCC may be locally destructive, it rarely metastasizes. Many diagnostic entities display morphologic and immunophenotypic overlap with BCC, including nonneoplastic processes, such as follicular induction over dermatofibroma; benign follicular tumors, such as trichoblastoma, trichoepithelioma, or basaloid follicular hamartoma; and malignant tumors, such as sebaceous carcinoma or Merkel cell carcinoma. Thus, misdiagnosis has significant potential to result in overtreatment or undertreatment. OBJECTIVE: - To review key features distinguishing BCC from histologic mimics, including current evidence regarding immunohistochemical markers useful for that distinction. DATA SOURCES: - Review of pertinent literature on BCC immunohistochemistry and differential diagnosis. CONCLUSIONS: - In most cases, BCC can be reliably diagnosed by histopathologic features. Immunohistochemistry may provide useful ancillary data in certain cases. Awareness of potential mimics is critical to avoid misdiagnosis and resulting inappropriate management.


Asunto(s)
Carcinoma Basocelular/diagnóstico , Neoplasias Cutáneas/diagnóstico , Piel/patología , Adenocarcinoma Sebáceo/diagnóstico , Adenocarcinoma Sebáceo/inmunología , Adenocarcinoma Sebáceo/metabolismo , Adenocarcinoma Sebáceo/patología , Biomarcadores de Tumor/metabolismo , Carcinoma Basocelular/inmunología , Carcinoma Basocelular/metabolismo , Carcinoma Basocelular/patología , Diagnóstico Diferencial , Hamartoma/diagnóstico , Hamartoma/inmunología , Hamartoma/metabolismo , Hamartoma/patología , Histiocitoma Fibroso Benigno/diagnóstico , Histiocitoma Fibroso Benigno/inmunología , Histiocitoma Fibroso Benigno/metabolismo , Histiocitoma Fibroso Benigno/patología , Humanos , Inmunohistoquímica/tendencias , Inmunofenotipificación/tendencias , Piel/inmunología , Piel/metabolismo , Neoplasias Cutáneas/inmunología , Neoplasias Cutáneas/metabolismo , Neoplasias Cutáneas/patología
5.
PLoS One ; 9(2): e89395, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24586747

RESUMEN

BACKGROUND: Reverse transcription quantitative real-time PCR (RT-qPCR) tests support personalized cancer treatment through more clinically meaningful diagnosis. However, samples obtained through standard clinical pathology procedures are formalin-fixed, paraffin-embedded (FFPE) and yield small samples with low integrity RNA containing PCR interfering substances. RT-qPCR tests able to assess FFPE samples with quality control and inter-laboratory reproducibility are needed. METHODS: We developed an RT-qPCR method by which 1) each gene was measured relative to a known number of its respective competitive internal standard molecules to control for interfering substances, 2) two-color fluorometric hydrolysis probes enabled analysis on a real-time platform, 3) external standards controlled for variation in probe fluorescence intensity, and 4) pre-amplification maximized signal from FFPE RNA samples. Reagents were developed for four genes comprised by a previously reported lung cancer diagnostic test (LCDT) then subjected to analytical validation using synthetic native templates as test articles to assess linearity, signal-to-analyte response, lower detection threshold, imprecision and accuracy. Fitness of this method and these reagents for clinical testing was assessed in FFPE normal (N = 10) and malignant (N = 10) lung samples. RESULTS: Reagents for each of four genes, MYC, E2F1, CDKN1A and ACTB comprised by the LCDT had acceptable linearity (R(2)>0.99), signal-to-analyte response (slope 1.0 ± 0.05), lower detection threshold (<10 molecules) and imprecision (CV <20%). Poisson analysis confirmed accuracy of internal standard concentrations. Internal standards controlled for experimentally introduced interference, prevented false-negatives and enabled pre-amplification to increase signal without altering measured values. In the fitness for purpose testing of this two-color fluorometric LCDT using surgical FFPE samples, the diagnostic accuracy was 93% which was similar to that previously reported for analysis of fresh samples. CONCLUSIONS: This quality-controlled two-color fluorometric RT-qPCR approach will facilitate the development of reliable, robust RT-qPCR-based molecular diagnostic tests in FFPE clinical samples.


Asunto(s)
Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Humanos , Adhesión en Parafina , Fijación del Tejido
6.
J Mol Diagn ; 15(3): 391-400, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23541592

RESUMEN

Reliable breakpoint cluster region (BCR)--Abelson (ABL) 1 measurement is essential for optimal management of chronic myelogenous leukemia. There is a need to optimize quality control, sensitivity, and reliability of methods used to measure a major molecular response and/or treatment failure. The effects of room temperature storage time, different primers, and RNA input in the reverse transcription (RT) reaction on BCR-ABL1 and ß-glucuronidase (GUSB) cDNA yield were assessed in whole blood samples mixed with K562 cells. BCR-ABL1 was measured relative to GUSB to control for sample loading, and each gene was measured relative to known numbers of respective internal standard molecules to control for variation in quality and quantity of reagents, thermal cycler conditions, and presence of PCR inhibitors. Clinical sample and reference material measurements with this test were concordant with results reported by other laboratories. BCR-ABL1 per 10(3) GUSB values were significantly reduced (P = 0.004) after 48-hour storage. Gene-specific primers yielded more BCR-ABL1 cDNA than random hexamers at each RNA input. In addition, increasing RNA inhibited the RT reaction with random hexamers but not with gene-specific primers. Consequently, the yield of BCR-ABL1 was higher with gene-specific RT primers at all RNA inputs tested, increasing to as much as 158-fold. We conclude that optimal measurement of BCR-ABL1 per 10(3) GUSB in whole blood is obtained when gene-specific primers are used in RT and samples are analyzed within 24 hours after blood collection.


Asunto(s)
Técnicas de Laboratorio Clínico/métodos , Proteínas de Fusión bcr-abl/genética , Leucemia Mielógena Crónica BCR-ABL Positiva/genética , Cartilla de ADN/genética , ADN Complementario/genética , Proteínas de Fusión bcr-abl/sangre , Glucuronidasa/genética , Humanos , Células K562 , Leucemia Mielógena Crónica BCR-ABL Positiva/sangre , Control de Calidad , ARN/genética , ARN/aislamiento & purificación , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
7.
PLoS One ; 8(11): e79120, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24236095

RESUMEN

Whole transcriptome RNA-sequencing is a powerful tool, but is costly and yields complex data sets that limit its utility in molecular diagnostic testing. A targeted quantitative RNA-sequencing method that is reproducible and reduces the number of sequencing reads required to measure transcripts over the full range of expression would be better suited to diagnostic testing. Toward this goal, we developed a competitive multiplex PCR-based amplicon sequencing library preparation method that a) targets only the sequences of interest and b) controls for inter-target variation in PCR amplification during library preparation by measuring each transcript native template relative to a known number of synthetic competitive template internal standard copies. To determine the utility of this method, we intentionally selected PCR conditions that would cause transcript amplification products (amplicons) to converge toward equimolar concentrations (normalization) during library preparation. We then tested whether this approach would enable accurate and reproducible quantification of each transcript across multiple library preparations, and at the same time reduce (through normalization) total sequencing reads required for quantification of transcript targets across a large range of expression. We demonstrate excellent reproducibility (R²â€Š= 0.997) with 97% accuracy to detect 2-fold change using External RNA Controls Consortium (ERCC) reference materials; high inter-day, inter-site and inter-library concordance (R²â€Š= 0.97-0.99) using FDA Sequencing Quality Control (SEQC) reference materials; and cross-platform concordance with both TaqMan qPCR (R²â€Šâ€Š= 0.96) and whole transcriptome RNA-sequencing following "traditional" library preparation using Illumina NGS kits (R²â€Š= 0.94). Using this method, sequencing reads required to accurately quantify more than 100 targeted transcripts expressed over a 107-fold range was reduced more than 10,000-fold, from 2.3×109 to 1.4×105 sequencing reads. These studies demonstrate that the competitive multiplex-PCR amplicon library preparation method presented here provides the quality control, reproducibility, and reduced sequencing reads necessary for development and implementation of targeted quantitative RNA-sequencing biomarkers in molecular diagnostic testing.


Asunto(s)
Reacción en Cadena de la Polimerasa Multiplex , Perfilación de la Expresión Génica , Biblioteca de Genes , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Curva ROC , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Análisis de Secuencia de ARN , Transcriptoma
8.
J Virol Methods ; 189(1): 129-42, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23375747

RESUMEN

Viral Hemorrhagic Septicemia virus (VHSv) causes one of the world's most important finfish diseases, killing >80 species across Eurasia and North America. A new and especially virulent strain (IVb) emerged in the North American Great Lakes in 2003, threatening fisheries, baitfish, and aquaculture industries. Weeks-long and costly cell culture is the OIE and USDA-APHIS approved diagnostic. A new Standardized Reverse Transcriptase Polymerase Chain Reaction (StaRT-PCR) assay that uniquely incorporates internal standards to improve accuracy and prevent false negatives was developed and evaluated for its ability to detect and quantify VHSv. Results from StaRT-PCR, SYBR(®) green real time qRT-PCR, and cell culture were compared, as well as the effects of potential PCR inhibitors (EDTA and high RNA). Findings show that StaRT-PCR is sensitive, detecting a single molecule, with 100% accuracy at six molecules, and had no false negatives. In comparison, false negatives ranged from 14 to 47% in SYBR(®) green real time qRT-PCR tests, and 47-70% with cell culture. StaRT-PCR uniquely controlled for EDTA and RNA interference. Range of VHSv quantitation by StaRT-PCR was 1.0×10(0)-1.2×10(5) VHSv/10(6)actb1 molecules in wild caught fishes and 1.0×10(0)-8.4×10(5) molecules in laboratory challenged specimens. In the latter experiments, muskellunge with skin lesions had significantly more viral molecules (mean=1.9×10(4)) than those without (1.1×10(3)) (p<0.04). VHSv infection was detected earlier in injection than in immersion challenged yellow perch (two versus three days), with molecule numbers in both being comparable and relatively consistent over the remaining course of the experiment. Our results show that the StaRT-PCR test accurately and reliably detects and quantifies VHSv.


Asunto(s)
Esocidae/virología , Enfermedades de los Peces/diagnóstico , Novirhabdovirus/aislamiento & purificación , Percas/virología , Infecciones por Rhabdoviridae/veterinaria , Animales , Secuencia de Bases , Benzotiazoles , Línea Celular , Diaminas , Reacciones Falso Negativas , Enfermedades de los Peces/virología , Datos de Secuencia Molecular , Novirhabdovirus/genética , Compuestos Orgánicos , Control de Calidad , Quinolinas , Estándares de Referencia , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Infecciones por Rhabdoviridae/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA