Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Bone Joint Surg Br ; 94(5): 713-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22529097

RESUMEN

Elastic stable intramedullary nailing (ESIN) is generally acknowledged to be the treatment of choice for displaced diaphyseal femoral fractures in children over the age of three years, although complication rates of up to 50% are described. Pre-bending the nails is recommended, but there are no published data to support this. Using synthetic bones and a standardised simulated fracture, we performed biomechanical testing to determine the influence on the stability of the fracture of pre-bending the nails before implantation. Standard ESIN was performed on 24 synthetic femoral models with a spiral fracture. In eight cases the nails were inserted without any pre-bending, in a further eight cases they were pre-bent to 30° and in the last group of eight cases they were pre-bent to 60°. Mechanical testing revealed that pre-bending to 60° produced a significant increase in the stiffness or stability of the fracture. Pre-bending to 60° showed a significant positive influence on the stiffness compared with unbent nails. Pre-bending to 30° improved stiffness only slightly. These findings validate the recommendations for pre-bending, but the degree of pre-bend should exceed 30°. Adopting higher degrees of pre-bending should improve stability in spiral fractures and reduce the complications of varus deformity and shortening.


Asunto(s)
Clavos Ortopédicos , Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas/instrumentación , Modelos Anatómicos , Adolescente , Preescolar , Elasticidad , Diseño de Equipo , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/métodos , Humanos , Ensayo de Materiales/métodos , Radiografía , Estrés Mecánico
2.
Clin Biomech (Bristol, Avon) ; 26(6): 592-7, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21345557

RESUMEN

BACKGROUND: Flexible intramedullary nail fixation of dislocated diaphyseal femur fractures has gained wide acceptance for children and adolescents with open physes. Studies with a special emphasis on complications reveal frequent problems regarding stability, usually in complex fracture types such as spiral fractures and in older children weighing >40kg. This biomechanical study analyses how much the material of the nails influences the stiffness in a synthetic bone model. METHODS: Twenty-four composite grafts (Sawbones®, 4th generation, medullar canal of 10mm) with an identical spiral fracture were used in three configurations of eight grafts. Elastic stable intramedullary nailing was performed in a retrograde C-shaped manner with two nails of equal size (2×3.5mm). Close contact of the fragments could be achieved. We compared Group A (steel nails) with Group B and C (two types of titanium nails). All specimens underwent 4-point bending, torsion and axial compression in the 0° and 9° positions, and the results were analysed. FINDINGS: Group A (steel nails) revealed a significantly higher stiffness in all directions than Group B. Apart from compression in the 9° position this steel nail fixation showed significant higher stiffness than titanium nails of Group C. Comparing Group B and C did not show an systematic difference. INTERPRETATION: In this biomechanical study with composite artificial bones the use of steel Nails demonstrated the highest stiffness in our model when compared to two different titanium nail configurations. Apart from in cases of known allergy or planned MRI-examinations our results and data from the literature question the use of titanium nails.


Asunto(s)
Fijación Intramedular de Fracturas/métodos , Adolescente , Fenómenos Biomecánicos , Clavos Ortopédicos , Huesos/patología , Niño , Elasticidad , Fracturas del Fémur/cirugía , Fémur/cirugía , Fijación Intramedular de Fracturas/instrumentación , Fracturas Óseas/patología , Humanos , Fijadores Internos , Imagen por Resonancia Magnética/métodos , Acero/química , Estrés Mecánico , Titanio/química
6.
Psychiatr Prax ; 22(5): 206-8, 1995 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-7480373

RESUMEN

A modified version of the Global Assessment of Functioning Scale (GAFS-M) which is proposed as axis V for DSM-IV by Goldman et al. (1992), was analyzed in a consecutive series of 266 psychiatric patients. Scores were clearly dependent on ICD-10 diagnosis and on other psychiatric variables. The scale was almost independent on self-rating in relevant psychopathological dimensions. Altogether, the results favour the view that the modified version of the GAFS is an economic and sufficient instrument for assessing adaptive functioning in psychiatric patients.


Asunto(s)
Trastornos Mentales/psicología , Determinación de la Personalidad/estadística & datos numéricos , Ajuste Social , Adaptación Psicológica , Adolescente , Adulto , Femenino , Humanos , Masculino , Trastornos Mentales/rehabilitación , Persona de Mediana Edad , Escalas de Valoración Psiquiátrica/estadística & datos numéricos , Psicometría , Reproducibilidad de los Resultados
7.
Paediatr Anaesth ; 8(3): 221-7, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9608967

RESUMEN

One hundred-and-fifty-five neonates and infants up to the sixth month of postnatal age were investigated to reveal the cause of clinically relevant stridor. In 100 patients congenital stridor was found, in 55 children the stridor was considered to be acquired. A curled, soft epiglottis, almost synonymously used with the diagnosis of congenital stridor, was found in 7% only, indicating different methods of investigation and different selection of patients compared to previous years. In acquired stridor the majority of infants showed laryngeal and tracheal trauma, mostly due to the use of too large tracheal tubes.


Asunto(s)
Anestesia por Inhalación , Intubación Intratraqueal , Ruidos Respiratorios/etiología , Obstrucción de las Vías Aéreas/congénito , Obstrucción de las Vías Aéreas/etiología , Obstrucción de las Vías Aéreas/fisiopatología , Anestésicos por Inhalación/administración & dosificación , Cartílago Aritenoides/anomalías , Cartílago Aritenoides/patología , Enfermedades Bronquiales/complicaciones , Broncoscopía , Constricción Patológica/complicaciones , Epiglotis/anomalías , Diseño de Equipo , Atresia Esofágica/complicaciones , Femenino , Glotis/anomalías , Glotis/patología , Halotano/administración & dosificación , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/instrumentación , Enfermedades de la Laringe/complicaciones , Laringoestenosis/congénito , Laringe/lesiones , Masculino , Estudios Prospectivos , Ruidos Respiratorios/fisiopatología , Propiedades de Superficie , Tráquea/lesiones , Enfermedades de la Tráquea/complicaciones , Fístula Traqueoesofágica/complicaciones , Pliegues Vocales/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA