Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Surg Endosc ; 35(3): 1088-1092, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32107631

RESUMEN

BACKGROUND: Post-cholecystectomy bile leak is relatively a well-known surgical complication. Several potential treatment modalities for such leaks are used. The early use of ERCP to exclude significant bile duct injury and to treat the leak by various endoscopic means is supported by a large bulk of data. However, there is no consensus as to the optimal endoscopic intervention. METHODS: A retrospective review of ERCP database was done to identify all cases of bile leak related to cholecystectomy. Patient records including surgical and endoscopic reports were reviewed, and telephone interviews were conducted to collect data. RESULTS: During the period 2004-2016, 100 patients (53 men, 47 women; mean age, 55 years) with post-cholecystectomy bile leak were referred for ERCP. Cholecystectomy was done laparoscopically in 82 patients (with an open conversion rate of 13%). In the majority of cases (77%), the leak was diagnosed by ongoing bile flow from the drains. The most common symptoms were pain (17%) and fever (4%). The most common site of the leak was the cystic duct stump (79%) followed by subvesical ducts (7%). Low grade leaks were seen in 84% of cases. Treatment included stent insertion alone (9%), sphincterotomy alone (11%), combination stent/sphincterotomy (76%) and others (1%). Failed ERCP was encountered in 3%. Endoscopic therapy was successful in 90 patients (90%). In subgroup analysis, success rate of procedures with stent insertion (with or without sphincterotomy) is significantly higher compared to procedures without stent insertion (95.3% vs 72.7%, p < 0.05). The failure rate of sphincterotomy alone procedures (3/11, 27%) is much higher compared to procedures with stent insertion (4/85, 5%) with p < 0.05. Four patients (4%) developed post-ERCP pancreatitis (mild to moderate) and one patient (1%) suffered from retroperitoneal perforation. CONCLUSION: The optimal endoscopic intervention for post-cholecystectomy bile leak should include temporary insertion of a biliary stent.


Asunto(s)
Bilis/química , Colecistectomía/efectos adversos , Endoscopía , Centros de Atención Terciaria , Adolescente , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Femenino , Humanos , Laparoscopía/efectos adversos , Masculino , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento
2.
Endoscopy ; 47(12): 1151-8, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26220283

RESUMEN

BACKGROUND AND STUDY AIMS: Adenoma miss rate during colonoscopy has become a widely acknowledged proxy measure for post-colonoscopy colorectal cancer. Among other reasons, this can happen because of inadequate visualization of the proximal aspects of colonic folds and flexures. EndoRings (EndoAid Ltd., Caesarea, Israel) is a silicone-rubber device that is fitted onto the distal end of the colonoscope. Its flexible circular rings engage and mechanically stretch colonic folds during withdrawal. The primary aim of this study was to compare adenoma miss rates between standard colonoscopy and colonoscopy using EndoRings. METHODS: In this multicenter, randomized, tandem colonoscopy study, we performed same-day, back-to-back colonoscopies with EndoRings followed by standard colonoscopy, or vice versa. RESULTS: After exclusion of 10 patients for protocol violations, 116 patients (38.8% female; mean age 58.7) remained for analysis. The adenoma miss rate of EndoRings colonoscopy (7/67; 10.4%) was significantly lower (P<0.001) compared with standard colonoscopy (28/58; 48.3%). Similar results were found for polyp miss rates: EndoRings (9.1%) and standard colonoscopy (52.8%; P<0.001). Mean cecal intubation times (9.3 vs. 8.4 minutes; P=0.142) and withdrawal times (7.4 vs. 7.2 minutes; P=0.286), respectively, were not significantly different between EndoRings and standard colonoscopy. Mean total procedure time was longer with EndoRings than with standard colonoscopy (21.6 vs. 18.5 minutes, P=0.001) as more polyps were removed. CONCLUSIONS: This study demonstrates that colonoscopy with EndoRings has lower adenoma and polyp miss rates than standard colonoscopy, which may improve the efficacy particularly of screening and surveillance colonoscopies. ClinicalTrials.gov NCT01955122.


Asunto(s)
Adenoma/diagnóstico , Pólipos del Colon/diagnóstico , Colonoscopios , Colonoscopía , Neoplasias Colorrectales/prevención & control , Errores Diagnósticos , Colonoscopía/instrumentación , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Investigación sobre la Eficacia Comparativa , Errores Diagnósticos/prevención & control , Errores Diagnósticos/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud
3.
Lancet Oncol ; 15(3): 353-60, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24560453

RESUMEN

BACKGROUND: Although colonoscopy is the accepted standard for detection of colorectal adenomas and cancers, many adenomas and some cancers are missed. To avoid interval colorectal cancer, the adenoma miss rate of colonoscopy needs to be reduced by improvement of colonoscopy technique and imaging capability. We aimed to compare the adenoma miss rates of full-spectrum endoscopy colonoscopy with those of standard forward-viewing colonoscopy. METHODS: We did an international, multicentre, randomised trial at three sites in Israel, one site in the Netherlands, and two sites in the USA between Feb 1, 2012, and March 31, 2013. Patients aged 18-70 years referred for colorectal cancer screening, polyp surveillance, or diagnostic assessment underwent same-day, back-to-back tandem colonoscopy with standard forward-viewing colonoscope and the full-spectrum endoscopy colonoscope. The patients were randomly assigned (1:1), via computer-generated randomisation with block size of 20, to which procedure was done first. The endoscopist was masked to group allocation until immediately before the start of colonoscopy examinations; patients were not masked. The primary endpoint was adenoma miss rates. We did per-protocol analyses. This trial is registered with ClinicalTrials.gov, number NCT01549535. FINDINGS: 197 participants were enrolled. 185 participants were included in the per-protocol analyses: 88 (48%) were randomly assigned to receive standard forward-viewing colonoscopy first, and 97 (52%) to receive full-spectrum endoscopy colonoscopy first. By per-lesion analysis, the adenoma miss rate was significantly lower in patients in the full-spectrum endoscopy group than in those in the standard forward-viewing procedure group: five (7%) of 67 vs 20 (41%) of 49 adenomas were missed (p<0·0001). Standard forward-viewing colonoscopy missed 20 adenomas in 15 patients; of those, three (15%) were advanced adenomas. Full-spectrum endoscopy missed five adenomas in five patients in whom an adenoma had already been detected with first-pass standard forward-viewing colonoscopy; none of these missed adenomas were advanced. One patient was admitted to hospital for colitis detected at colonoscopy, whereas five minor adverse events were reported including vomiting, diarrhoea, cystitis, gastroenteritis, and bleeding. INTERPRETATION: Full-spectrum endoscopy represents a technology advancement for colonoscopy and could improve the efficacy of colorectal cancer screening and surveillance. FUNDING: EndoChoice.


Asunto(s)
Adenoma/diagnóstico , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Adolescente , Adulto , Anciano , Humanos , Persona de Mediana Edad
4.
Am J Gastroenterol ; 109(11): 1795-802; quiz 1803, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25267328

RESUMEN

OBJECTIVES: Systemic corticosteroids are among the most common anti-inflammatory treatments in elderly-onset inflammatory bowel disease (IBD) patients. Steroid use and older age each independently predisposes to infections, and infections increase mortality in hospitalized older IBD patients. Therefore, our objective was to examine the risk of serious infections in elderly-onset IBD patients treated with oral corticosteroids, and explore how the timing of exposure affects the risk estimates. METHODS: Using the health-care databases of the province of Quebec, Canada, we conducted a population-based cohort study with a nested case-control analysis. Incident IBD patients aged ≥66 years were identified. Conditional logistic regression was performed to estimate crude and adjusted rate ratios (aRRs) with 95% confidence intervals (CIs). RESULTS: We identified 3,522 elderly-onset patients, of which 564 cases with serious infections were identified during a mean 4.4 years of follow-up (incidence rate 3.7 per 100 per year) and matched to 2,646 controls. The rate of serious infections was significantly higher in those exposed to oral corticosteroids any time during the previous 6-month period compared with those nonexposed (aRR 2.3; 95% CI 1.8-2.9). Those currently exposed (within 45 days) had a higher risk (aRR 2.8; 95% CI 2.1-3.7). The residual effect of oral corticosteroids remained marginally statistically significant up to the 90-day period before the index date (aRR 1.7; 95% CI 1.0-2.7). CONCLUSIONS: We found an excess relative risk for serious infections in elderly-onset IBD patients on oral corticosteroid therapy. Those with current exposure demonstrated a higher vulnerability to infections.


Asunto(s)
Corticoesteroides/efectos adversos , Infecciones/inducido químicamente , Enfermedades Inflamatorias del Intestino/tratamiento farmacológico , Administración Oral , Corticoesteroides/administración & dosificación , Edad de Inicio , Anciano , Estudios de Casos y Controles , Comorbilidad , Femenino , Humanos , Incidencia , Infecciones/epidemiología , Masculino , Quebec/epidemiología
5.
Endoscopy ; 46(10): 883-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25225962

RESUMEN

BACKGROUND AND STUDY AIMS: Although colonoscopy is the gold standard for detecting colorectal cancer (CRC), adenomas and cancers are missed. We aimed to establish the safety and feasibility of use of a novel balloon-colonoscope. PATIENTS AND METHODS: Patients (40 - 75 years) referred for CRC screening, polyp surveillance, or diagnostic evaluation were enrolled in a prospective pilot cohort study whose primary endpoint was device safety. Additional endpoints included success of and time to cecal intubation, withdrawal and total procedure times, polyp detection rate (PDR), adenoma detection rate (ADR), and success of polypectomies. RESULTS: Among 50 patients (mean age 59.0 years, 27 women [54 %]), three were excluded (inadequate colon preparation, technical problem, abdominal hernia) and 47 were analyzed. Two patients experienced minor adverse events (diarrhea, abdominal pain). Cecal intubation rate was 47 /47 (100 %). Mean times, to reach cecum, withdrawal, and total procedure, were 4.3, 7.4, and 16.5 minutes, respectively. We identified 44 polyps (all successfully removed) in 25 /47 patients (PDR 53.2 %), 35 polyps (79.5 %) were 1 - 5 mm, 4 (9.1 %) 6 - 9 mm, and 5 (11.4 %) ≥ 10 mm. Of 44 polyps, 36 (81.8 %) were "adenomas"; 21/47 patients had ≥ 1 adenoma (ADR 44.7 %). CONCLUSIONS: The NaviAid G-EYE balloon-colonoscope appears safe and feasible to use. Comparative human studies are underway.Clinicaltrials.gov identifier: NCT01749722.


Asunto(s)
Adenoma/diagnóstico , Pólipos del Colon/diagnóstico , Colonoscopios/efectos adversos , Colonoscopía/efectos adversos , Colonoscopía/instrumentación , Neoplasias Colorrectales/diagnóstico , Detección Precoz del Cáncer/instrumentación , Dolor Abdominal/etiología , Adenoma/cirugía , Adulto , Anciano , Cateterismo , Ciego , Pólipos del Colon/patología , Pólipos del Colon/cirugía , Diarrea/etiología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Proyectos Piloto , Estudios Prospectivos , Factores de Tiempo
7.
Gastrointest Endosc ; 77(3): 472-9, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23410700

RESUMEN

BACKGROUND: Although colonoscopy is the criterion standard for detecting colorectal adenomas and cancers, a significant percentage of adenomas are missed. OBJECTIVE: To compare forward-viewing with ultrawide-viewing colonoscopy in the detection of simulated colon polyps in an in vitro colon model. DESIGN: Prospective, multicenter. SETTING: Six endoscopy units (3 in the United States and 3 in Israel). PATIENTS: In vitro colon model with simulated colon polyps (n = 21 metallic beads). INTERVENTIONS: Detection of simulated colon polyps on colonoscope withdrawal. MAIN OUTCOME MEASUREMENTS: Incremental detection of simulated colon polyps and endoscopist evaluation of the usability, visibility, and maneuverability of ultrawide-viewing colonoscopy. RESULTS: On forward-viewing colonoscopy, the number of simulated polyps (mean ± standard deviation) detected per endoscopist was 11.1 ± 2.3 polyps, a 52.9% detection rate. Simulated polyp detection rates per colon segment were 3.0 ± 0.93 (60.0%) right colon, 2.4 ± 0.87 (48.0%) transverse colon, and 5.7 ± 1.5 (51.8%) left colon. On ultrawide-viewing colonoscopy, the simulated polyp detection rate per endoscopist significantly increased to 18.0 ± 1.98 polyps, an overall 85.7% polyp detection rate (P < .001). Simulated polyp detection rates were also significantly higher by using the ultrawide-viewing mode in each colon segment, 4.5 ± 0.65 polyps (90.0%) right colon, 4.0 ± 0.87 (80.0%) polyps transverse colon, and 9.6 ± 1.28 polyps (87.3%) left colon (all comparisons, P < .001). Importantly, the ultrawide-viewing mode detected significantly more "hidden" simulated polyps (81.9% vs 31.9%, P < .0001). LIMITATIONS: Nonrandomized design, use of a colon model, and "simulated" colon polyps. CONCLUSIONS: Ultrawide-view colonoscopy significantly improved simulated polyp detection in a colon model. Clinical studies in human subjects should be pursued to further evaluate this new endoscopic technology.


Asunto(s)
Pólipos del Colon/diagnóstico , Colonoscopios , Colonoscopía/métodos , Adulto , Actitud del Personal de Salud , Competencia Clínica , Colonoscopía/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Dispositivos Ópticos , Estudios Prospectivos
8.
Endoscopy ; 45(9): 697-702, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23939509

RESUMEN

BACKGROUND AND STUDY AIMS: Although colonoscopy is the criterion standard for detecting colorectal adenomas and cancers, a significant percentage of adenomas are missed with this technique. We aimed to establish the feasibility, usability, and safety of a novel colonoscopy platform featuring full-spectrum endoscopy (FUSE). PATIENTS AND METHODS: This was a prospective, single-center pilot and feasibility study. In total, 50 individuals, ages 18 - 70 years, underwent colonoscopy featuring FUSE (up to 330° field of view) for colorectal cancer screening, polyp surveillance, or diagnostic evaluation. Study end points included success of cecal intubation, time to cecal intubation, withdrawal time, total procedure time, success of therapeutic interventions, adverse events, and endoscopists' subjective evaluation of FUSE. RESULTS: Cecal intubation was achieved in 50/50 individuals (100 %). Time to cecum (minutes, mean ± SD) was 3.1 ± 1.5 minutes, withdrawal time 12.7 ± 4.4 minutes, and total procedure time 15.3 ± 4.6 minutes. In 22/50 cases (44 %), 26 therapeutic interventions were performed: 19 (73.1 %) biopsies and 7 (26.9 %) polypectomies. No acute or delayed adverse events were observed. Patient satisfaction and endoscopist subjective evaluation were high. CONCLUSIONS: A colonoscopy platform featuring full-spectrum endoscopy appears feasible, usable, and safe. These results represent an important advance in colonoscopy imaging technology and should be further pursued in comparative human studies.


Asunto(s)
Adenoma/diagnóstico , Ciego , Colonoscopía/instrumentación , Neoplasias Colorrectales/diagnóstico , Detección Precoz del Cáncer/métodos , Intubación , Adenoma/cirugía , Adolescente , Adulto , Anciano , Actitud del Personal de Salud , Colonoscopía/efectos adversos , Neoplasias Colorrectales/cirugía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Satisfacción del Paciente , Proyectos Piloto , Factores de Tiempo , Adulto Joven
10.
Ann Gastroenterol ; 34(3): 337-343, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33948058

RESUMEN

BACKGROUND: Benign esophageal anastomotic strictures often require repeat dilation to relieve dysphagia. Little is known about the factors that affect their remediation. The purpose of this article was to retrospectively evaluate the long-term clinical results of endoscopic dilation in the treatment of benign anastomotic strictures after esophagectomy, and to identify factors associated with stricture recurrence. METHODS: A single-center retrospective analysis (using electronic records) was performed on patients who underwent endoscopic dilation for esophageal anastomotic strictures. Long-term clinical effectiveness, including technical and clinical success, and complication rate were assessed. Factors independently related to recurrence were evaluated. RESULTS: Between January 2014 and December 2017, a total of 35 patients who had benign anastomotic strictures after esophagectomy underwent 182 endoscopic dilation procedures. Technical success was 100%. Thirty-two patients (91%) had initial relief of dysphagia. The clinical success, defined as resolution of dysphagia and achieving luminal patency of 13 mm or more, was achieved in 24 patients (69%). Strictures recurred in 43% of patients, and refractory strictures were identified in 10/35 (29%). Proximal anastomosis and the presence of anastomotic foreign bodies were found to be risk factors for refractory strictures. The complication rate was low (4%) and adverse events were mild. No major complications (perforations, severe bleeding) or treatment-related deaths occurred in this series. CONCLUSIONS: Endoscopic dilation has a high technical and a good clinical success rate. However, anastomotic strictures are often refractory and frequently recur.

12.
Ann Gastroenterol ; 32(3): 303-311, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31040629

RESUMEN

BACKGROUND: Endoscopist-directed balanced propofol sedation (BPS) appears to be safe and effective for routine endoscopy. However, there are limited data on its use in endoscopic retrograde cholangiopancreatography (ERCP). We evaluated the safety and efficacy of endoscopist-directed BPS for ERCP, and compared patient outcomes with anesthesiologist-administered moderate sedation. METHODS: This was a retrospective cohort study, using prospectively collected endoscopy data from a tertiary care medical center where endoscopist-directed BPS during ERCP is routine practice. Adverse outcomes included need for bag-mask ventilation or intubation, aborted ERCP due to sedation, hospital admission post-ERCP (outpatients)/change in the level of care (inpatients), and death within 24 h. RESULTS: A total of 501 patients underwent ERCP with the use of endoscopist-directed BPS: Cohort 1 - 380 (76%) inpatients, mean age 64.1, 46% male, 24% American Society of Anesthesiologists physical status (ASA) score I, 65% ASA II, 11% ASA III. Concurrently, 24 patients received anesthesiologist-administered moderate sedation: Cohort 2 - 19 (79%) inpatients, mean age 65.0, 67% male, 12% ASA I, 25% ASA II, 38% ASA III, 25% ASA IV. In Cohort 1, none of the adverse outcomes were observed. Propofol dose was inversely correlated with age (r=-0.42, P<0.001), ASA score (r=-0.19, P<0.001), and Mallampati score (r=-0.24, P<0.001). One patient in Cohort 2 who received anesthesiologist-administered BPS required bag-mask ventilation and the ERCP was prematurely aborted because of the sedation. There were no deaths from any cause within 24 h of ERCP. CONCLUSION: Endoscopist-directed BPS appears safe, efficacious, and feasible for ASA I-III patients undergoing inpatient or ambulatory ERCP.

13.
Surg Obes Relat Dis ; 14(8): 1093-1098, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29895427

RESUMEN

BACKGROUND: Laparoscopic sleeve gastrectomy (LSG) is considered as a first line treatment for morbid obesity around the globe. Leakage and subsequent gastric fistula is the most dreadful complication, which may lead to serious morbidity and even mortality. OBJECTIVES: To assess the safety and efficacy of fibrin glue application in the setting of gastric fistula after LSG. SETTING: University hospital, Israel. METHODS: Twenty-four morbidly obese patients (mean age = 42.2 yr, mean body mass index = 42 kg/m2) developed gastric fistula after LSG. The fistula was acute in 10 patients, subacute in 9, and chronic in 5. Sixteen patients (67%) have had previous failed endoscopic interventions. Fibrin glue was applied percutaneously with fluoroscopic guidance, under endoscopic visualization. A pigtail drain was left in the distal tract to monitor and manage possible continuous leakage. RESULTS: There were no complications except abdominal pain in 2 patients associated with fever in 1. Both resolved within 1 to 2 days. Fistula closure was achieved in all patients but 1 (95.8%). Closure was accomplished after a single application in 9 patients (39%), 2 applications in 8, 3 applications in 3, 5 applications in 2, and 6 applications in 1. All patients were followed with a mean time of 42.3 months (range, 20-46). CONCLUSIONS: Although in most patients there was a need for multiple applications, our experience indicates that percutaneous fluoroscopic application of Fibrin glue under endoscopic visualization proved to be a simple, tolerable, and highly effective method for the treatment of selected patients with gastric fistula after LSG.


Asunto(s)
Adhesivo de Tejido de Fibrina/uso terapéutico , Gastrectomía/efectos adversos , Fístula Gástrica/cirugía , Laparoscopía/efectos adversos , Complicaciones Posoperatorias/cirugía , Adhesivos Tisulares/uso terapéutico , Adolescente , Adulto , Femenino , Adhesivo de Tejido de Fibrina/administración & dosificación , Adhesivo de Tejido de Fibrina/efectos adversos , Gastrectomía/estadística & datos numéricos , Humanos , Laparoscopía/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adhesivos Tisulares/administración & dosificación , Adhesivos Tisulares/efectos adversos , Adulto Joven
14.
Harefuah ; 145(11): 811-4, 862, 861, 2006 Nov.
Artículo en Hebreo | MEDLINE | ID: mdl-17183952

RESUMEN

BACKGROUND: The source of obscure bleeding is usually located in the small bowel. The use of capsule endoscopy (CE) has changed the management of these patients. GOALS: To review our experience with the diagnosis of small bowel tumors by CE in patients with obscure overt gastrointestinal bleeding. METHODS: Retrospective analysis of CE examinations performed consecutively in two university-affiliated hospitals. RESULTS: Among 156 patients who underwent CE examination (including 58 patients with obscure overt bleeding), five patients, all of whom presented with melena, were diagnosed as having a small bowel tumor. Three tumors were found in one patient (two ileal carcinoids and one ileal benign stromal tumor). A jejunal benign stromal tumor was diagnosed in two other patients by push enteroscopy. One of these was missed by a subsequent capsule endoscopy examination, and in the other, only active bleeding was detected by prior capsule endoscopy. In two patients, three small tumors were detected, beyond the reach of push enteroscopy, but surgical confirmation was not available. No tumors were found among patients in whom the indication for CE examination was not obscure overt bleeding. CONCLUSIONS: The possibility of finding a small bowel tumor emphasizes the role of capsule endoscopy in patients with obscure overt gastrointestinal bleeding. Push enteroscopy should be performed when capsule endoscopy yields negative or only suspicious findings.


Asunto(s)
Endoscopía Capsular/métodos , Hemorragia Gastrointestinal/etiología , Neoplasias Intestinales/diagnóstico , Anciano , Femenino , Humanos , Neoplasias del Yeyuno/diagnóstico , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
15.
Free Radic Biol Med ; 39(3): 336-44, 2005 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-15993332

RESUMEN

The paraoxonase (PON) family contains three genes (PON1/2/3) that are believed to be involved in the protection against oxidative stress. PON1 and PON3 are circulating in serum attached to high-density lipoprotein fraction (HDL), whereas PON2 is ubiquitously expressed. The intestine is the second major organ that synthesizes lipoproteins; therefore, we examined PON mRNA expression and protein levels in gastrointestinal biopsies from humans, from C57BL6 mice, and from Caco-2 cells, a colon carcinoma-derived cell line that exhibits properties of intestinal epithelium at differentiation. PON 1/2/3 mRNA and proteins were present in human biopsies with variable expression among different gastrointestinal segments. Only PON2 and PON3 were present in mice. All PON mRNA, proteins, and enzymatic activities were present in Caco-2 cells. Oxidation of CaCo-2 cells with ferrum ascorbate had no significant effect on PON mRNA expression, but it increased paraoxonase and lactonase activity, whereas statinase activity was decreased. We showed polarized secretion of PON1 (basolateral) and PON2 (apical) into Caco-2 culture medium, raising the possibility that intestine is capable of producing and releasing PON1 and PON3 to the circulation, whereas PON2 is released at the brush-border membrane to intestinal lumen where it may perform another yet unclear function.


Asunto(s)
Arildialquilfosfatasa/biosíntesis , Tracto Gastrointestinal/enzimología , Tracto Gastrointestinal/metabolismo , Animales , Línea Celular Tumoral , Humanos , Masculino , Ratones , Oxidación-Reducción , ARN Mensajero/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
16.
Obes Surg ; 25(5): 942-5, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25716127

RESUMEN

BACKGROUND: The intragastric migration of a surgically placed adjustable gastric band is believed to occur slowly, over months to years. Band removal procedures necessitate surgical laparotomy, thus increasing the risk of complications. METHODS: The endoscopic technique for band removal described in this case-series provides a minimally invasive approach. RESULTS: Fifteen patients referred for endoscopic removal of a partially migrated intragastric band. The partially migrated intragastric bands were all successfully removed in a mean of 1.1 endoscopic sessions. No patient required subsequent surgical intervention, and there were no immediate or delayed adverse events including no infections, bleeding, or perforations. CONCLUSIONS: Endoscopic removal of partially migrated intragastric bands appears feasible, effective, safe, and is a minimally invasive alternative to repeat surgery.


Asunto(s)
Remoción de Dispositivos/métodos , Migración de Cuerpo Extraño/cirugía , Gastroplastia/instrumentación , Adulto , Endoscopía , Femenino , Gastroplastia/métodos , Humanos , Laparotomía , Masculino , Estudios Prospectivos
17.
Eur J Gastroenterol Hepatol ; 15(4): 363-7, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12655255

RESUMEN

BACKGROUND: The recently introduced wireless M2A capsule video endoscopy (CVE) has been demonstrated to be superior to barium follow-through and enteroscopy in diagnosing patients with occult blood loss and iron-deficiency anaemia. OBJECTIVE: To further investigate CVE in comparison to barium follow-through and entero-computerized tomography (CT) in establishing the diagnosis of patients with suspected Crohn's disease. DESIGN AND SETTING: The study was conducted in one academic hospital. Twenty patients with recurrent abdominal pain and/or weight loss or chronic diarrhoea underwent barium follow-through as their initial examination, followed by CVE (if there was no stricture) and entero-CT. The radiologist that performed the barium follow-through and entero-CT was blinded to the results of the CVE. A blinded reader who was unaware of the study objective diagnosed the results of the CVE. In most cases in which there was a discrepancy between examinations, colonoscopy and ileoscopy were performed. For each patient, the diagnosis and disease extent were recorded. RESULTS: Twenty patients (13 males, 7 females; mean age 31 years, range 20-57) were included in the study. Ninety-five per cent of the patients had abdominal pain, 75% had diarrhoea, and 65% had weight loss. The mean haemoglobin level of the group was 13.1 g% (range 10-15.5). Only 13 patients underwent entero-CT.CVE confirmed the diagnosis of Crohn's disease that was suspected by alternative methods in six of the 20 patients. CVE made the diagnosis of Crohn's disease in six patients that had normal barium follow-through or entero-CT. CVE ruled out a diagnosis of Crohn's disease suspected by other modalities in three patients. CVE extended the involvement of Crohn's disease in three of the patients, and established new diagnoses in two patients. SUMMARY: CVE established new diagnoses, confirmed existing diagnoses, enlarged the extent of the disease, and ruled out the suspicion of Crohn's disease in 70% of the patients. Barium follow-through established diagnoses, measured the extent of the disease, and ruled out the suspicion of Crohn's disease in 37% of the patients. The capsule detected all of the lesions diagnosed by barium follow-through and entero-CT. CVE detected additional lesions that were not detected by other modalities in 47% of cases and ruled out lesions that were detected by other modalities in 16% of cases (P < 0.05). CONCLUSION: CVE is a superior and more sensitive procedure than barium follow-through and entero-CT in establishing the diagnosis and estimating the extent of Crohn's disease.


Asunto(s)
Sulfato de Bario , Enfermedad de Crohn/diagnóstico , Endoscopía Gastrointestinal/métodos , Tomografía Computarizada por Rayos X , Adulto , Enfermedad de Crohn/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
20.
Pancreas ; 35(2): 130-4, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17632318

RESUMEN

OBJECTIVES: Between 1997 and 2001, a single-center chart review demonstrated significant impact of endoscopic ultrasonography (EUS) in evaluating suspected pancreatic cancer (PCA). Repeating and comparing this review with that from 2001 to 2004 was performed to determine whether increased use of EUS results in more patients being accurately chosen for curative versus palliative procedures, and for surgical versus nonsurgical oncotherapy. METHODS: The complete systematic review was made up of electronic files from the gastroenterology, oncology, and pathology departments of patients presenting with suspected PCA. Results were compared with those obtained in 1997-2001. RESULTS: From 2001 to 2004, 72 patients had PCA. Seven tumor types were identified. Forty-seven percent (34/72) of patients with suspected PCA were preoperatively staged by EUS; 24% (17/72) of all patients underwent surgery. Comparatively, from 1997 to 2001, only 32% (20/62) of patients were evaluated by EUS (P = 0.056) and 45% (28/62) of all patients underwent surgery (P < 0.01). The EUS detected a tumor in 32 of 34 cases. The EUS-guided fine-needle aspiration cytology identified PCA in 14 of 18 cases. F-18-deoxyglucose-positron emission tomography and magnetic resonance imaging were not used. Endoscopic retrograde cholangiopancreatography was performed in 29% (21/72) of patients, with 15 stents inserted. CONCLUSIONS: Increased EUS use for diagnosing and staging PCA resulted in fewer patients undergoing futile surgery. The EUS plays a pivotal role in the management of patients with PCA.


Asunto(s)
Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Anciano , Endoscopía , Femenino , Humanos , Estudios Longitudinales , Masculino , Estadificación de Neoplasias , Neoplasias Pancreáticas/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA