Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Transfusion ; 63(2): 349-359, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36537152

RESUMEN

BACKGROUND: In Poland, hepatitis A virus (HAV) RNA screening was performed in plasma for fractionation usually immediately before shipment. OBJECTIVE: Our goal was to study epidemiology, rate of transfusion transmitted HAV during epidemic (2017-2019), and viral characteristics of infected plasma donors. STUDY DESIGN AND METHODS: HAV RNA was tested in 1,866,590 donations from 1,210,423 donors using RT-PCR in mini pools of 96 (MP96) or TMA in MP16. Virological characteristics included RNA level (RL), antibody testing, and sequencing. RESULTS: Twenty-one HAV infections were identified (1.13/100,000 donations; 95% confidence interval [95% CI]: 0.74-1.72) and (1.73/100,000 donors; 95% CI: 1.35-2.65). The Blood Transfusion Centers were also informed about three donors, who were hospitalized for hepatitis A soon after their blood donation. In addition, we identified a donor, who had reactive result for HAV after receiving HAV vaccination. He tested positive twice 10 days after receiving the first and the second dose. The highest RL was 16 million IU/ml, mean 1,706,905 IU/ml, and median 220 IU/ml. The longest detectable RL lasted for 113 days. HAV-infected donors were seronegative (36%) or IgM positive (64%). We followed up on 12 HAV contaminated blood components issued for transfusion. In two out of seven identified patients viral transmission was confirmed (28.6%). CONCLUSION: Based on our results, we propose a 6 month deferral after HAV infection and 14 days post HAV vaccination. The infectivity rate was below 30%. The HAV RNA testing could be considered as an additional safeguard against HAV transmission at the time of increased incidence of HAV infections in the general population.


Asunto(s)
Virus de la Hepatitis A , Hepatitis A , Masculino , Humanos , Donantes de Sangre , Polonia/epidemiología , ARN Viral , Transfusión de Componentes Sanguíneos , Hepatitis A/epidemiología , Virus de la Hepatitis A/genética
2.
J Med Virol ; 92(3): 339-347, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31670401

RESUMEN

Nucleic acid testing (NAT) was implemented in Poland in 1999 for screening of plasma for fractionation and for all blood donors in 2002. To analyze seronegative NAT-positive samples representing hepatitis C virus (HCV) window-period (WP) in the years 2000 to 2016 and to determine infection outcome. We analyzed results of 17 502 739 donations screened in minipools (6-48) or individually. Index samples underwent viral load (VL) quantification, genotyping and Ag, and anti-HCV re-testing using chemiluminescence (CMIA), electrochemiluminescence (ECLIA), and fourth-generation enzyme-linked immunosorbent assay (IV EIA) assays. HCV-seronegative infections were identified in 126 donations (7.2/mln donations; 95% confidential intervals, 6.0-8.6). Frequency of NAT yields was decreasing over time. Of the initial 126 seronegative index cases 106 were retested: 32.1% were reactive in IV EIA, 11.3% in ECLIA, and 1.9% in CMIA. The lowest VL correlated with absent anti-HCV and HCV Ag, while VL was highest when the antigen was detectable and then it decreased when anti-HCV appeared at a level detectable by sensitive third generation tests while retesting. The proportion of genotype 1 was 38.9% in samples positive only for HCV RNA and 71.4% in samples that were anti-HCV reactive in re-testing. In parallel, genotype 3 frequency was 50% in the former group and 21% in the latter. NAT is an effective measure to limit HCV transmission by transfusion and IV EIA seems to have higher clinical sensitivity than ECLIA. Samples representing likely successive phases of early HCV infection were characterized by different genotype distribution probably due to very early elimination of genotype 3.


Asunto(s)
Donantes de Sangre , Hepatitis C/sangre , Tamizaje Masivo/normas , ARN Viral/sangre , Adolescente , Adulto , Donantes de Sangre/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Genotipo , Hepatitis C/diagnóstico , Anticuerpos contra la Hepatitis C/sangre , Humanos , Masculino , Técnicas de Amplificación de Ácido Nucleico , Polonia , Pruebas Serológicas , Carga Viral , Adulto Joven
4.
Transfusion ; 58(5): 1245-1253, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29492976

RESUMEN

BACKGROUND: Until now, markers of hepatitis E virus (HEV) infection have not been studied in blood donors throughout Poland, and no acute case of HEV infection has been closely documented or confirmed by HEV RNA detection. The prevalence of HEV infection markers, including HEV RNA in Polish blood donors and virus genotypes was investigated. STUDY DESIGN AND METHODS: In total, 12,664 individual donations from 22 Polish blood transfusion centers were tested for HEV RNA by transcription-mediated amplification. In addition, 3079 first-time donors sampled throughout Poland also were screened for antibodies to HEV. HEV RNA and immunoglobulin M-positive donations were confirmed using real-time reverse transcription-polymerase chain reaction and Western blotting, respectively. RESULTS: Ten donors were identified as RNA initial reactive (one of 1266 donors), and six (one of 2109) were identified as repeat reactive and confirmed by real-time reverse transcription-polymerase chain reaction or seroconversion. Sequence analysis identified HEV Genotype 3c in one donor and Genotype 3i in two others. On average, 43.5% of donors were immunoglobulin G-positive. Immunoglobulin G seroprevalence ranged from 22.7% to 60.8% in group ages 18 to 27 years and 48 to 57 years, respectively and differed between administrative regions from 28.9% in Podlasie to 61.3% in Wielkopolska. Thirty-nine of the donors were immunoglobulin M-positive, and seven donors were IgM positive only (0.2%). Of 37 immunoglobulin M-reactive samples tested by Western blot, 24 (64.9%) were confirmed. CONCLUSIONS: The current results indicate a high level of HEV endemicity throughout Poland compared with other countries. There is an urgent need to consider the protection of recipients of blood components against transfusion-transmitted HEV infection.


Asunto(s)
Donantes de Sangre , Enfermedades Endémicas , Virus de la Hepatitis E/genética , Hepatitis E/epidemiología , Adolescente , Adulto , Biomarcadores/sangre , Femenino , Genotipo , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Polonia , ARN Viral/sangre , Estudios Seroepidemiológicos , Reacción a la Transfusión/epidemiología , Adulto Joven
5.
Acta Haematol Pol ; 48(3): 174-182, 2017.
Artículo en Polaco | MEDLINE | ID: mdl-32226060

RESUMEN

Blood transfusion in Poland is the safest in history. High virological level of safety has been achieved mainly by improving not only the qualification of donors and methods used for donor screening, but also applying leukoreduction, pathogen reduction technology and grace period for serum.In this article, we discuss the improvement of the epidemic situation among blood donors for hepatitis B virus (HBV) and hepatitis C virus (HCV) and the increasing trend for HIV. Preliminary results of residual risk calculation for these pathogens are presented.Hepatitis E virus (HEV) and Babesia microti were considered as new factors potentially relevant for the safety of blood transfusion in our country. Due to evidence of West Nile virus (WNV) circulation in the ecosystem in Poland, it is also necessary to monitor the infections with this pathogen.In this article, it was emphasized that the reporting of all possible complications associated with transfusion and meticulous implementation of the look-back procedure play a key role for monitoring the risk of transmission of infectious agents by blood. It is especially important in view of the increasing epidemiological problems associated with emerging infectious agents.

6.
Przegl Epidemiol ; 69(3): 473-7, 591-5, 2015.
Artículo en Inglés, Polaco | MEDLINE | ID: mdl-26519842

RESUMEN

Blood donor screening of viral markers in Poland is based on serologic testing for anti-HCV, HBsAg, anti-HIV1/2 (chemiluminescence tests) and on nucleic acid testing (NAT) for RNA HCV, RNA HIV-1 and DNA HBV performed in minipools of 6 with real-time PCR (MPX 2.0 test on cobas s201) or with TMA in individual donations (Ultrio Plus or Ultrio Elite). Donors of plasma for anti-D and anti-HBs production are tested for parvovirus B19 DNA. Before implementation tests and equipment are evaluated at the Institute of Hematology and Transfusion Medicine (IHTM). The last 20 years witnessed a decreasing trend for HBsAg in both first time and repeat donors (1%-0.3% and 0.1%-0.02% respectively). Prevalence of anti-HCV repeat reactive results was stable and oscillated around 0.8% for first time donors and 0.2% for repeat donors. Elevated prevalence of seropositive HIV infected donors was recently observed (7.5-9 cases/100,000 donors). Since respective molecular markers implementation HCV RNA was detected on average in 1/119,235 seronegative donations, HIV RNA in 1/783,821 and HBV DNA in 1/61,047. HBV NAT yields were mostly occult hepatitis B (1/80,248); window period cases were less frequent (1/255,146). The efficiency of HBV DNA detection depends on the sensitivity of the HBV DNA screening system.


Asunto(s)
Donantes de Sangre/estadística & datos numéricos , ADN Viral/sangre , Tamizaje Masivo/estadística & datos numéricos , ARN Viral/sangre , Virosis/prevención & control , Selección de Donante , Humanos , Polonia , Pruebas Serológicas/estadística & datos numéricos , Virosis/sangre , Virosis/transmisión
7.
Przegl Epidemiol ; 66(1): 7-12, 2012.
Artículo en Polaco | MEDLINE | ID: mdl-22708291

RESUMEN

UNLABELLED: Since 2004 Polish blood donors have been tested for parvovirus B19 (B19V) DNA. The screening testing has been performed in donors of plasma for fractionation and anti-D and anti-HBs production and donors of erythrocytes used for immunization. AIM is to present methods of the testing, quality control and results in period 2004-2010. MATERIAL AND METHODS: Testing was performed in individual donation testing (IDT) in Regional Blood Transfusion Center (RBTC) in Lublin or in pools of 24 in Institute of Haematology and Transfusion Medicine in Warsaw (IHTM). Quantitative testing with real-time PCR was preceded with nucleic acid isolation on silica based methods (Prepito Viral DNA/RNA, Chemagen and QIAamp DNA Mini Kit, QIAGEN). Amplification was performed initially with home made method and later with commercial assay (Artus Parvo B19 RG PCR Kit on Rotor Gene 6 000). In total 17 625 donations were tested: 8 539 in pools and 9 090 individually. Beside routine external quality control programmes in which both laboratories participated (Proficiency Study VQC,Amsterdam, Holand; EQA Programe, Glasgow, Scotland), panel containing negative samples, positive with very high DNA B 19V level and plasma infected with genotype 2 was prepared for RBTC in Lublin. RESULTS: B19V infection frequency was 1:980 donations, low viraemic donations were detected most frequently (1:1 037). It was identified only one donation with DNA load that could cause potential health risk for plasma product recipients (1:17 625). In one of the donors B 19V DNA was observed for 3 years and 3 months. In acute or persistent phase of infection no clinical or laboratory symptoms (morphology of peripheral blood, ALT) were observed. Due to risk of underestimation of viral load connected with viral genome polymorphism all donations with B19V positive result were not allowed to be clinically used.


Asunto(s)
Anticuerpos Antivirales/sangre , Donantes de Sangre/estadística & datos numéricos , ADN Viral/sangre , Infecciones por Parvoviridae/prevención & control , Parvovirus B19 Humano/aislamiento & purificación , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones por Parvoviridae/epidemiología , Parvovirus B19 Humano/genética , Polonia/epidemiología , Reacción en Cadena de la Polimerasa/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad , Pruebas Serológicas/métodos , Carga Viral
8.
Viruses ; 14(6)2022 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-35746798

RESUMEN

This study aims to characterize the intermediates, and the final product (FP) obtained during the production of human intramuscular hyperimmune gamma globulin anti-SARS-CoV-2 (hIHGG anti-SARS-CoV-2) and to determine its stability. Material and methods: hIHGG anti-SARS-CoV-2 was fractionated from 270 convalescent plasma donations with the Cohn method. Prior to fractionation, the plasma was inactivated (Theraflex MB Plasma). Samples were defined using enzyme immunoassays (EIA) for anti-S1, anti-RBD S1, and anti-N antibodies, and neutralization assays with SARS-CoV-2 (VN) and pseudoviruses (PVN, decorated with SARS-CoV-2 S protein). Results were expressed as a titer (EIA) or 50% of the neutralization titer (IC50) estimated in a four-parameter nonlinear regression model. Results: Concentration of anti-S1 antibodies in plasma was similar before and after inactivation. Following fractionation, the anti-S1, anti-RBD, and anti-N (total tests) titers in FP were concentrated approximately 15-fold from 1:4 to 1:63 (1800 BAU/mL), 7-fold from 1:111 to 1:802 and from 1:13 to 1:88, respectively. During production, the IgA (anti-S1) antibody titer was reduced to an undetectable level and the IgM (anti-RBD) titer from 1:115 to 1:24. The neutralizing antibodies (nAb) titer increased in both VN (from 1:40 to 1:160) and PVN (IC50 from 63 to 313). The concentration of specific IgG in the FP did not change significantly for 14 months. Conclusions: The hIHGG anti-SARS-CoV-2 was stable, with concentration up to approximately 15-fold nAb compared to the source plasma pool.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , COVID-19/terapia , Humanos , Inmunización Pasiva , Glicoproteína de la Espiga del Coronavirus , gammaglobulinas , Sueroterapia para COVID-19
9.
J Med Virol ; 83(1): 142-9, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21108352

RESUMEN

Parvovirus B19 (B19V) is divided into three genotypes. Genotypes 2 and 3 may cause diagnostic difficulties and their epidemiology is not well understood. In the present study the prevalence of B19V genotypes in patients with symptomatic infection in Poland was evaluated and the course of infection in patients infected with non-genotype 1 strains is described. Real-time PCR, able to detect all three genotypes of B19V was used to screen patient plasma samples. Sixty-nine, mainly acute-phase B19V DNA positive cases were identified in patients from hematological and obstetric/gynecological wards between 2004 and 2008. Thirty patients were studied in greater detail and genotyping was performed by analysis of the NS1/VP1u region. The majority of samples were genotype 1. However two (6.6%) strains were identified as genotype 2, associated with high viremia and identified in a kidney transplant recipient with anemia and a leukemia patient, following chemotherapy, with pancytopenia. A change of immunosuppression treatment in the former and treatment with intravenous immunoglobulin in latter, resulted in normalization of clinical parameters, and whilst viral loads fell, B19V DNA was still detectable. The kidney transplant recipient subsequently became pregnant with no clinical complications, although persistently infected with B19V genotype 2. This is the first description of symptomatic cases of genotype 2 B19V infection in Eastern Europe suggesting that acute infection, particularly among immunocompromised patients with these virus strains may be more prevalent than thought.


Asunto(s)
Huésped Inmunocomprometido , Infecciones por Parvoviridae/epidemiología , Infecciones por Parvoviridae/virología , Parvovirus B19 Humano/clasificación , Parvovirus B19 Humano/genética , Análisis por Conglomerados , ADN Viral/genética , Femenino , Genotipo , Humanos , Datos de Secuencia Molecular , Infecciones por Parvoviridae/patología , Parvovirus B19 Humano/aislamiento & purificación , Filogenia , Polonia/epidemiología , Reacción en Cadena de la Polimerasa , Embarazo , Análisis de Secuencia de ADN , Proteínas Virales/genética
10.
Sci Rep ; 11(1): 12734, 2021 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-34140600

RESUMEN

Surveillance on the HIV molecular variability, risk of drug resistance transmission and evolution of novel viral variants among blood donors remains an understudied aspect of hemovigilance. This nationwide study analyses patterns of HIV diversity and transmitted resistance mutations. Study included 185 samples from the first time and repeat blood donors with HIV infection identified by molecular assay. HIV protease, reverse transcriptase and integrase were sequenced using population methods. Drug resistance mutation (DRM) patterns were analyzed based on the Stanford Interpretation Algorithm and standardized lists of transmitted mutations. Phylogeny was used to investigate subtyping, clustering and recombination patterns. HIV-1 subtype B (89.2%) followed by subtype A6 (7.6%) were predominant, while in three (1.6%) cases, novel recombinant B/A6 variants were identified. Non-B variants were more common among repeat donors (14.5%) compared to the first time ones (1.8%), p = 0.011, with higher frequency (9.9%) of A6 variant in the repeat donor group, p = 0.04. Major NRTI DRMs were observed in 3.8%, NNRTI and PI in 0.6% and INSTI 1.1% of cases. Additionally, E157Q polymorphism was observed in 9.8% and L74I in 11.5% of integrase sequences. Transmission of drug resistance among blood donors remains infrequent. Subtype patters increase in complexity with emergence of novel intersubtype A6B recombinants.


Asunto(s)
Fármacos Anti-VIH/farmacología , Donantes de Sangre , Farmacorresistencia Viral/genética , Infecciones por VIH/tratamiento farmacológico , VIH/efectos de los fármacos , Adulto , Fármacos Anti-VIH/uso terapéutico , Estudios de Cohortes , VIH/clasificación , VIH/genética , Humanos , Masculino , Mutación/efectos de los fármacos , Filogenia , Polonia
11.
Pol J Microbiol ; 59(2): 129-32, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20734759

RESUMEN

Extremely high viremia is observed during some viruses infection, especialy in immunocompromised patients. False negative results of Parvovirus B 19 DNA tests performed with real-time PCR in high viremic samples are reported. The way of fluorescence diagrams analysis and algorithm of positive result confirmation to exclude such phenomenon are proposed.


Asunto(s)
Parvovirus B19 Humano/aislamiento & purificación , Reacción en Cadena de la Polimerasa/métodos , Viremia/diagnóstico , Reacciones Falso Negativas , Humanos , Parvovirus B19 Humano/genética , Reacción en Cadena de la Polimerasa/normas , Viremia/virología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA