Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(2)2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38257463

RESUMEN

Dispersive interferometry based on a femtosecond laser is extensively utilized for achieving absolute distance measurements with high accuracy. However, this method cannot measure arbitrary distances without encountering a dead zone, and deviations in its output results are inevitable due to inherent theory limitations. Therefore, two enhanced data-processing algorithms are proposed to improve the accuracy and reduce the dead zone of dispersive interferometry. The principles of the two proposed algorithms, namely the truncated-spectrum algorithm and the high-order-angle algorithm, are proposed after explaining the limitations of conventional methods. A series of simulations were conducted on these algorithms to show the improved accuracy of measurement results and the elimination of the dead zone. Furthermore, an experimental setup based on a dispersive interferometer was established for the application of these proposed algorithms to the experimental interference spectral signals. The results demonstrated that compared with the conventional algorithm, the proposed truncated-spectrum algorithm could reduce the output distance deviations derived from direct inverse Fourier transforming by eight times to reach as low as 1.3 µm. Moreover, the unmeasurable dead zone close to the zero position of the conventional algorithm, i.e., the minimum working distance of a dispersive interferometer, could be shortened to 22 µm with the implementation of the proposed high-order-angle algorithm.

2.
Sensors (Basel) ; 24(9)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38732974

RESUMEN

Spectrally resolved interferometry utilizing a femtosecond laser is widely employed for absolute distance measurement. However, deviations in the output time pulse of the conventional algorithm through inverse Fourier transform are inevitable. Herein, an improved data processing algorithm employing a time-shifting parameter is proposed to improve the accuracy of spectrally resolved interferometry. The principle of the proposed time-shifting algorithm is analyzed theoretically after clarifying the deviation source of the conventional algorithm. Simulation and experimental work were conducted to indicate the improvement in the accuracy of the output absolute distance. The results demonstrated that the proposed algorithm could reduce the deviation of output distances towards the reference values, reaching 0.58 µm by half compared to the conventional algorithm. Furthermore, the measurement uncertainty was evaluated using the Guide to the Expression of Uncertainty in Measurement (GUM), resulting in an expanded uncertainty of 0.71 µm with a 95% confidence.

3.
Sensors (Basel) ; 23(10)2023 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-37430864

RESUMEN

Two algorithms of data processing are proposed to shorten the unmeasurable dead-zone close to the zero-position of measurement, i.e., the minimum working distance of a dispersive interferometer using a femtosecond laser, which is a critical issue in millimeter-order short-range absolute distance measurement. After demonstrating the limitation of the conventional data processing algorithm, the principles of the proposed algorithms, namely the spectral fringe algorithm and the combined algorithm that combines the spectral fringe algorithm with the excess fraction method, are presented, together with simulation results for demonstrating the possibility of the proposed algorithms for shortening the dead-zone with high accuracy. An experimental setup of a dispersive interferometer is also constructed for implementing the proposed data processing algorithms over spectral interference signals. Experimental results demonstrate that the dead-zone using the proposed algorithms can be as small as half of that of the conventional algorithm while measurement accuracy can be further improved using the combined algorithm.