Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-35469557

RESUMEN

Since Queensland eased border restrictions to the rest of Australia on 13 December 2021, notified cases of Coronavirus disease 2019 (COVID-19) dramatically increased, with the SARS-CoV-2 Omicron variant now the most widespread variant of concern: 145,881 cases and 13 deaths were recorded in Queensland in the month following the opening of the border. For an effective public health response to a highly transmissible disease, it is important to know the prevalence in the community, but the exponential increase in cases meant that many with symptoms had difficulty getting tested. We implemented a surveillance program on the Gold Coast that used a modified randomised household cluster survey method to estimate the point prevalence of individuals with SARS-CoV-2 detected by polymerase chain reaction (PCR). The estimated point prevalence of SARS-CoV-2 detected by PCR on self-collected swabs was 17.2% on the first visit to households (22 January 2022). This subsequently decreased to 5.2% (5 February 2022) and finally to 1.1% (19 February 2022). Out of 1,379 specimens tested over five weeks, 63 had detected SARS-CoV-2 and 35 (55.6%) were sequenced. All were SARS-CoV-2 variant: B.1.1.529 (i.e. Omicron). This surveillance program could be scaled up or reproduced in other jurisdictions to estimate the prevalence of COVID-19 in the community.Since Queensland eased border restrictions to the rest of Australia on 13 December 2021, notified cases of Coronavirus disease 2019 (COVID-19) dramatically increased, with the SARS-CoV-2 Omicron variant now the most widespread variant of concern: 145,881 cases and 13 deaths were recorded in Queensland in the month following the opening of the border. For an effective public health response to a highly transmissible disease, it is important to know the prevalence in the community, but the exponential increase in cases meant that many with symptoms had difficulty getting tested. We implemented a surveillance program on the Gold Coast that used a modified randomised household cluster survey method to estimate the point prevalence of individuals with SARS-CoV-2 detected by polymerase chain reaction (PCR). The estimated point prevalence of SARS-CoV-2 detected by PCR on self-collected swabs was 17.2% on the first visit to households (22 January 2022). This subsequently decreased to 5.2% (5 February 2022) and finally to 1.1% (19 February 2022). Out of 1,379 specimens tested over five weeks, 63 had detected SARS-CoV-2 and 35 (55.6%) were sequenced. All were SARS-CoV-2 variant: B.1.1.529 (i.e. Omicron). This surveillance program could be scaled up or reproduced in other jurisdictions to estimate the prevalence of COVID-19 in the community.


Asunto(s)
COVID-19 , SARS-CoV-2 , Australia/epidemiología , COVID-19/epidemiología , Humanos , Prevalencia
2.
Hip Int ; 26(3): 254-9, 2016 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-27079286

RESUMEN

INTRODUCTION: During total hip arthroplasty (THA), accurately predicting acetabular cup orientation remains a key challenge, in great part because of uncertainty about pelvic orientation. This pilot study aimed to develop and validate a technique to measure pelvic orientation; establish its accuracy in the location of anatomical landmarks and subsequently; investigate if limb movement during a simulated surgical procedure alters pelvic orientation. METHODS: The developed technique measured 3-D orientation of an isolated Sawbone pelvis, it was then implemented to measure pelvic orientation in lateral decubitus with post-THA patients (n = 20) using a motion capture system. RESULTS: Orientation of the isolated Sawbone pelvis was accurately measured, demonstrated by high correlations with angular data from a coordinate measurement machine; R-squared values close to 1 for all pelvic axes. When applied to volunteer subjects, largest movements occurred about the longitudinal pelvic axis; internal and external pelvic rotation. Rotations about the anteroposterior axis, which directly affect inclination angles, showed >75% of participants had movement within ±5° of neutral, 0°. CONCLUSIONS: The technique accurately measured orientation of the isolated bony pelvis. This was not the case in a simulated theatre environment. Soft tissue landmarks were difficult to palpate repeatedly. These findings have direct clinical relevance, landmark registration in lateral decubitus is a potential source of error, contributing here to large ranges in measured movement. Surgeons must be aware that present techniques using bony landmarks to reference pelvic orientation for cup implantation, both computer-based and mechanical, may not be sufficiently accurate.


Asunto(s)
Acetábulo/anatomía & histología , Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/fisiología , Inestabilidad de la Articulación/prevención & control , Rango del Movimiento Articular/fisiología , Cirugía Asistida por Computador/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Orientación Espacial/fisiología , Proyectos Piloto , Cuidados Preoperatorios/métodos , Factores de Riesgo , Rotación , Sensibilidad y Especificidad
3.
Hip Int ; 25(5): 452-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26391265

RESUMEN

Perception of a leg length discrepancy post total hip arthroplasty (THA) is one of the most common sources of patient dissatisfaction and can have a direct influence on the considered success of the operation.This research examined postoperative perception of imposed limb discrepancies in a group of THA patients compared to a group of participants with no previous hip surgery. Two subgroups of THA patients were involved: those who did not perceive a difference in limb length following THA and those that did.Discrepancies were imposed in 2.5 mm increments. For discrepancies ≥5 mm, a significant number of participants were aware of a difference (74%). There was no significant difference in perception of imposed discrepancies between THA patients and participants with no previous hip surgery. THA patients who perceived a difference in their limb lengths postoperatively had significantly worse pain and oxford scores when compared to THA patients who perceived their limb lengths to be equal. Knowing the boundaries between LLDs that go undetected and those that patients are aware of could guide surgeons when evaluating the balance between correct soft tissue tension and the resulting unequal leg length. From these findings, discrepancies >5 mm are likely to be perceived. Whether this perception would lead directly to a negative outcome score and patient dissatisfaction is more complex to project and likely to be patient specific. Intraoperative methods to aid the controlled positioning of implanted components could help maintain and restore leg length to within an acceptable amount that patients cannot perceive.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera , Diferencia de Longitud de las Piernas/etiología , Percepción/fisiología , Complicaciones Posoperatorias/diagnóstico , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Casos y Controles , Prueba de Esfuerzo/métodos , Femenino , Humanos , Diferencia de Longitud de las Piernas/epidemiología , Diferencia de Longitud de las Piernas/psicología , Modelos Lineales , Masculino , Persona de Mediana Edad , Posicionamiento del Paciente , Complicaciones Posoperatorias/epidemiología , Valores de Referencia
4.
Hip Int ; 22(6): 683-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23233171

RESUMEN

The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons. Target angles were compared with achieved angles and deviations from desired angles were recorded. In addition, all participants orientated cups under the same conditions using two other techniques: freehand and with a propriatory Mechanical Alignment Guide. In the first trial, the mean errors (deviations) using freehand technique, the mechanical alignment guide and the new device were 5.2° +/- 4.3° (range 0.1-22.0), 3.6° +/- 3.9° (range 0.1°-33.6°) and 0.5° +/- 0.4° (range 0.0-1.9) respectively. In the second trial, the mean error for freehand technique, mechanical alignment guide and the new device were 6.2° +/- 4.2° (range 0.2-18.2), 3.8° +/- 3.3° (range 0.0-19.1) and 0.6° +/- 0.5° (range 0.0-1.8) respectively. The new device has the potential to allow the surgeon to choose and record operative inclination accurately during total hip arthroplasty in the lateral decubitus position.


Asunto(s)
Acetábulo/anatomía & histología , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Posicionamiento del Paciente , Diseño de Equipo , Humanos
5.
Acta Biomater ; 7(2): 548-57, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20849986

RESUMEN

Predicable and controlled degradation is not only central to the accurate delivery of bioactive agents and drugs, it also plays a vital role in key aspects of bone tissue engineering. The work addressed in this paper investigates the utilisation of e-beam irradiation in order to achieve a controlled (surface) degradation profile. This study focuses on the modification of commercially and clinically relevant materials, namely poly(L-lactic acid) (PLLA), poly(L-lactide-hydroxyapatite) (PLLA-HA), poly(L-lactide-glycolide) co-polymer (PLG) and poly(L-lactide-DL-lactide) co-polymer (PLDL). Samples were subjected to irradiation treatments using a 0.5MeV electron beam with delivered surface doses of 150 and 500 kGy. In addition, an acrylic attenuation shield was used for selected samples to control the penetration of the e-beam. E-beam irradiation induced chain scission in all polymers, as characterized by reduced molecular weights and glass transition temperatures (T(g)). Irradiation not only produced changes in the physical properties of the polymers but also had associated effects on surface erosion of the materials during hydrolytic degradation. Moreover, the extent to which both mechanical and hydrolytic degradation was observed is synonymous with the estimated penetration of the beam (as controlled by the employment of an attenuation shield).


Asunto(s)
Materiales Biocompatibles/química , Electrones , Polímeros/química , Rastreo Diferencial de Calorimetría , Cromatografía en Gel , Cristalización , Durapatita/química , Ácido Láctico/química , Microscopía Electrónica de Rastreo , Peso Molecular , Poliésteres/química , Poliglactina 910/química , Estrés Mecánico , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA