1.
Stereotact Funct Neurosurg ; 101(5): 326-331, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37607507

RESUMEN

BACKGROUND: Advances in MRI technology have increased interest in direct targeting for deep brain stimulation (DBS). Various imaging sequences have been shown to provide increased contrast of numerous common DBS targets, such as T1-weighted, Fast Gray Matter Acquisition T1 Inversion Recovery (FGATIR), gray matter nulled, and Edge-Enhancing Gradient Echo (EDGE); however, the continual increase in the number of necessary sequences has led to an increase in imaging time, which is undesirable. Additionally, carefully timed inversion pulses can often lead to less-than-ideal contrast in some subjects, particularly in ultra-high field MRI, where B1+ field inhomogeneity can lead to substantial contrast variation. OBJECTIVES: This study proposes using 3D MP2RAGE-based T1 maps to retrospectively synthesize images of any desired inversion time, including T1-weighted, FGATIR, and EDGE contrasts, to visualize specific DBS targets at both 3T and 7T. METHOD: First, a systematic sequence optimization framework was applied to optimize MP2RAGE T1 mapping sequence parameters for the purpose of DBS planning. Next, we show that synthetic inversion-time images can be generated through a mathematical transformation of the T1 maps. The sequence was then applied to patients undergoing preoperative planning for DBS at 3T and 7T to generate synthetic contrasts used in surgical planning. RESULTS: We show that synthetic image contrasts can be generated across a full range of inversion times at 3T and 7T, including commonly used sequences for DBS targeting, such as T1-weighted, FGATIR, and EDGE. Acquisition through a single sequence shortens scan time compared to acquiring the sequences independently without affecting image quality or contrast. CONCLUSIONS: The generation of synthetic images for DBS targeting allows faster acquisition of many key sequences, as well as the ability to optimize contrast properties post-acquisition to account for the variable B1+ effects present in ultra-high field MRI. The proposed approach has the potential to reduce imaging time and improve the accuracy of DBS targeting at 1.5T, 3T, and 7T.

2.
Neuroimage ; 252: 119043, 2022 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-35235838

RESUMEN

Deep brain stimulation (DBS) is an increasingly utilized treatment for multiple neurological disorders. Continued improvements in DBS outcome are, in part, related to increasing ability to directly visualize stimulation targets by MRI. However, it is challenging to image DBS targets with conventional MRI techniques due to limited contrast. Fast Gray Matter Acquisition T1 Inversion Recovery (FGATIR) is a commonly used MRI sequence that improves visualization of several key DBS targets by suppressing white matter (WM) signal to better reveal deep-brain gray matter (GM) structures. Due to increased signal level at high field strength, application of FGATIR on 7T MRI may allow higher spatial resolution and better DBS targeting accuracy. However, successful utilization of FGATIR requires meticulous sequence optimization involving multiple parameters to maximize GM signal while suppressing WM. This is further complicated by the transmit RF field (B1+) inhomogeneity on 7T, which can cause severe contrast degradation. In this work, we introduce a systematic approach to optimize FGATIR and to improve visualization of thalamic DBS targets on 7T. FGATIR optimization is cast into a constrained optimization problem whose objective function and constraints are designed to maximize the GM-WM contrast-to-noise ratio (CNR) while accounting for B1+ inhomogeneity. This approach allows a systematic search for optimal parameters across the multi-dimensional parametric space while limiting the negative effect of B1+ variation. Bloch equation simulations were performed to solve the proposed optimization problem and to compare the sequence derived from this method against the sequence optimized without considering B1+ inhomogeneity. The results showed that this approach can improve GM-WM CNR in the presence of B1+ inhomogeneity, especially in some high relative B1+ areas where several key thalamic DBS targets are located. Additionally, in vivo images were acquired on a clinical 7T MRI to further validate this approach. Severe contrast degradation in the thalamus was observed when B1+ effect was not considered in sequence optimization, while the proposed approach yielded improved image contrast in the thalamus with key DBS targets well-defined. These results demonstrated that the proposed method allowed optimization of FGATIR on 7T to better visualize thalamic DBS targets, which may lead to improved DBS targeting accuracy as well as treatment outcome.


Asunto(s)
Estimulación Encefálica Profunda , Sustancia Blanca , Encéfalo/diagnóstico por imagen , Corteza Cerebral , Estimulación Encefálica Profunda/métodos , Sustancia Gris/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Sustancia Blanca/diagnóstico por imagen
3.
Eur Radiol ; 31(9): 6621-6630, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33713174

RESUMEN

OBJECTIVES: To compare the accuracy of coronary calcium quantification of cadaveric specimens imaged from a photon-counting detector (PCD)-CT and an energy-integrating detector (EID)-CT. METHODS: Excised coronary specimens were scanned on a PCD-CT scanner, using both the PCD and EID subsystems. The scanning and reconstruction parameters for EID-CT and PCD-CT were matched: 120 kV, 9.3-9.4 mGy CTDIvol, and a quantitative kernel (D50). PCD-CT images were also reconstructed using a sharper kernel (D60). Scanning the same specimens using micro-CT served as a reference standard for calcified volumes. Calcifications were segmented with a half-maximum thresholding technique. Segmented calcified volume differences were analyzed using the Friedman test and post hoc pairwise Wilcoxon signed rank test with the Bonferroni correction. Image noise measurements were compared between EID-CT and PCD-CT with a repeated-measures ANOVA test and post hoc pairwise comparison with the Bonferroni correction. A p < 0.05 was considered statistically significant. RESULTS: The volume measurements in 12/13 calcifications followed a similar trend: EID-D50 > PCD-D50 > PCD-D60 > micro-CT. The median calcified volumes in EID-D50, PCD-D50, PCD-D60, and micro-CT were 22.1 (IQR 10.2-64.8), 21.0 (IQR 9.0-56.5), 18.2 (IQR 8.3-49.3), and 14.6 (IQR 5.1-42.4) mm3, respectively (p < 0.05 for all pairwise comparisons). The average image noise in EID-D50, PCD-D50, and PCD-D60 was 60.4 (± 3.5), 56.0 (± 4.2), and 113.6 (± 8.5) HU, respectively (p < 0.01 for all pairwise comparisons). CONCLUSION: The PCT-CT system quantified coronary calcifications more accurately than EID-CT, and a sharp PCD-CT kernel further improved the accuracy. The PCD-CT images exhibited lower noise than the EID-CT images. KEY POINTS: • High spatial resolution offered by PCD-CT reduces partial volume averaging and consequently leads to better morphological depiction of coronary calcifications. • Improved quantitative accuracy for coronary calcification volumes could be achieved using high-resolution PCD-CT compared to conventional EID-CT. • PCD-CT images exhibit lower image noise than conventional EID-CT at matched radiation dose and reconstruction kernel.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Cadáver , Humanos , Fantasmas de Imagen , Tomógrafos Computarizados por Rayos X
4.
J Magn Reson Imaging ; 51(1): 296-310, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31111581

RESUMEN

BACKGROUND: Distortion-free, high-resolution diffusion imaging using DIADEM (Distortion-free Imaging: A Double Encoding Method), proposed recently, has great potential for clinical applications. However, it can suffer from prolonged scan times and its reliability for quantitative diffusion imaging has not been evaluated. PURPOSE: To investigate the clinical feasibility of DIADEM-based high-resolution diffusion imaging on a novel compact 3T (C3T) by evaluating the reliability of quantitative diffusion measurements and utilizing both the high-performance gradients (80 mT/m, 700 T/m/s) and the sequence optimization with the navigator acquisition window reduction and simultaneous multislice (multiband) imaging. STUDY TYPE: Prospective feasibility study. PHANTOM/SUBJECTS: Diffusion quality control phantom scans to evaluate the reliability of quantitative diffusion measurements; 36 normal control scans for B0 -field mapping; six healthy and two patient subject scans with a brain tumor for comparisons of diffusion and anatomical imaging. FIELD STRENGTH/SEQUENCE: 3T; the standard single-shot echo-planar-imaging (EPI), multishot DIADEM diffusion, and anatomical (2D-FSE [fast-spin-echo], 2D-FLAIR [fluid-attenuated-inversion-recovery], and 3D-MPRAGE [magnetization prepared rapid acquisition gradient echo]) imaging. ASSESSMENT: The scan time reduction, the reliability of quantitative diffusion measurements, and the clinical efficacy for high-resolution diffusion imaging in healthy control and brain tumor volunteers. STATISTICAL TEST: Bland-Altman analysis. RESULTS: The scan time for high in-plane (0.86 mm2 ) resolution, distortion-free, and whole brain diffusion imaging were reduced from 10 to 5 minutes with the sequence optimizations. All of the mean apparent diffusion coefficient (ADC) values in phantom were within the 95% confidence interval in the Bland-Altman plot. The proposed acquisition with a total off-resonance coverage of 597.2 Hz wider than the expected bandwidth of 500 Hz in human brain could yield a distortion-free image without foldover artifacts. Compared with EPI, therefore, this approach allowed direct image matching with the anatomical images and enabled improved delineation of the tumor boundaries. DATA CONCLUSION: The proposed high-resolution diffusion imaging approach is clinically feasible on C3T due to a combination of hardware and sequence improvements. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1 J. Magn. Reson. Imaging 2020;51:296-310.


Asunto(s)
Encéfalo/anatomía & histología , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen Eco-Planar , Estudios de Factibilidad , Humanos , Fantasmas de Imagen , Estudios Prospectivos , Reproducibilidad de los Resultados
5.
Radiographics ; 39(3): 729-743, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31059394

RESUMEN

Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X/métodos , Animales , Medios de Contraste , Diseño de Equipo , Humanos , Compuestos de Yodo , Dosis de Radiación , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/tendencias
7.
Radiology ; 288(2): 476-484, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29664337

RESUMEN

Purpose To describe the relationship between conventional magnetic resonance (MR) imaging parameters and MR elastography of the pancreas in association with pancreatic histologic features and occurrence of postoperative pancreatic fistula (POPF). Materials and Methods Patients who underwent preoperative MR imaging (MR elastography and diffusion-, T1-, and T2-weighted imaging) followed by pancreatectomy with pancreaticoenteric anastomosis were included. The relationships between preoperative MR imaging parameters, demographic data, and intraoperative factors with POPF risk were analyzed with logistic regression analyses. The correlation of MR imaging parameters with histologic characteristics was evaluated with multivariate regression analysis. Results A total of 112 patients (64 men, 48 women; median age, 58 years) were evaluated. Forty-two patients (37.5%) developed POPF and 20 (17.9%) developed high-grade POPF (grades B and C). Lower pancreatic stiffness (≤1.43 kPa; odds ratio [OR], 9.196; 95% confidence interval [CI]: 1.92, 43.98), nondilated main pancreatic duct (MPD) diameter (<3 mm; OR, 7.298; 95% CI: 1.51, 35.34), and larger stump area (≥211 mm2; OR, 9.210; 95% CI: 1.53, 55.26) were risk factors for POPF. Lower pancreatic stiffness (≤1.27 kPa; OR, 8.389; 95% CI: 1.88, 37.41) was the only independent predictor of high-grade POPF. Log-transformed pancreatic stiffness was independently associated with fibrosis (ß = 0.060; 95% CI: 0.052, 0.068), acinar atrophy (ß = 0.015; 95% CI: 0.003, 0.028), and lipomatosis (ß = -0.016; 95% CI: -0.026, -0.006). Conclusion Preoperative MR assessment of pancreatic stiffness, MPD diameter, and stump area are important predictors of POPF.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Páncreas/patología , Páncreas/cirugía , Fístula Pancreática/epidemiología , Complicaciones Posoperatorias/epidemiología , Anastomosis Quirúrgica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Páncreas/diagnóstico por imagen , Valor Predictivo de las Pruebas , Periodo Preoperatorio , Factores de Riesgo
8.
Magn Reson Med ; 79(4): 2024-2035, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28833440

RESUMEN

PURPOSE: To develop a fully automated trajectory and gradient waveform design for the non-Cartesian shells acquisition, and to develop a magnetization-prepared (MP) shells acquisition to achieve an efficient three-dimensional acquisition with improved gray-to-white brain matter contrast. METHODS: After reviewing the shells k-space trajectory, a novel, fully automated trajectory design is developed that allows for gradient waveforms to be automatically generated for specified acquisition parameters. Designs for two types of shells are introduced, including fully sampled and undersampled/accelerated shells. Using those designs, an MP-Shells acquisition is developed by adjusting the acquisition order of shells interleaves to synchronize the center of k-space sampling with the peak of desired gray-to-white matter contrast. The feasibility of the proposed design and MP-Shells is demonstrated using simulation, phantom, and volunteer subject experiments, and the performance of MP-Shells is compared with a clinical Cartesian magnetization-prepared rapid gradient echo acquisition. RESULTS: Initial experiments show that MP-Shells produces excellent image quality with higher data acquisition efficiency and improved gray-to-white matter contrast-to-noise ratio (by 36%) compared with the conventional Cartesian magnetization-prepared rapid gradient echo acquisition. CONCLUSION: We demonstrated the feasibility of a three-dimensional MP-Shells acquisition and an automated trajectory design to achieve an efficient acquisition with improved gray-to-white matter contrast. Magn Reson Med 79:2024-2035, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/diagnóstico por imagen , Sustancia Gris/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética , Magnetismo , Sustancia Blanca/diagnóstico por imagen , Algoritmos , Automatización , Medios de Contraste , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Programas Informáticos
9.
Magn Reson Med ; 79(3): 1538-1544, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28639370

RESUMEN

PURPOSE: Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second-order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth-order or B0 ) and linear (first-order) spatial dependence. METHODS: This work demonstrates a general solution to eliminate the zeroth-order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo-planar imaging (EPI), and fast spin-echo imaging. RESULTS: A global phase offset is reduced in the phase-contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase-encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast-spin echo images. CONCLUSION: A user-transparent method to compensate the zeroth-order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences-both product and research-to be retained without any modifications. Magn Reson Med 79:1538-1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Humanos , Procesamiento de Señales Asistido por Computador , Muñeca/diagnóstico por imagen
10.
Magn Reson Med ; 79(3): 1354-1364, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28643408

RESUMEN

PURPOSE: To investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first-order spatial dependence on fast/turbo spin-echo acquisitions, and to demonstrate the effectiveness of their real-time compensation. METHODS: After briefly reviewing the CF produced by asymmetric gradients, the effects of the additional zeroth and first-order CFs on these systems are investigated using extended-phase graph simulations. Phantom and in vivo experiments are performed to corroborate the simulation. Experiments are performed before and after the real-time compensations using frequency tracking and gradient pre-emphasis to demonstrate their effectiveness in correcting the additional CFs. The interaction between the CFs and prescan-based correction to compensate for eddy currents is also investigated. RESULTS: It is demonstrated that, unlike the second-order CFs on conventional gradients, the additional zeroth/first-order CFs on asymmetric gradients cause substantial signal loss and dark banding in fast spin-echo acquisitions within a typical brain-scan field of view. They can confound the prescan correction for eddy currents and degrade image quality. Performing real-time compensation successfully eliminates the artifacts. CONCLUSIONS: We demonstrate that the zeroth/first-order CFs specific to asymmetric gradients can cause substantial artifacts, including signal loss and dark bands for brain imaging. These effects can be corrected using real-time compensation. Magn Reson Med 79:1354-1364, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Artefactos , Encéfalo/diagnóstico por imagen , Simulación por Computador , Humanos , Fantasmas de Imagen
11.
J Magn Reson Imaging ; 48(6): 1498-1507, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30255963

RESUMEN

BACKGROUND: Gradient nonlinearity (GNL) leads to biased apparent diffusion coefficients (ADCs) in diffusion-weighted imaging. A gradient nonlinearity correction (GNLC) method has been developed for whole body systems, but is yet to be tested for the new compact 3T (C3T) scanner, which exhibits more complex GNL due to its asymmetrical design. PURPOSE: To assess the improvement of ADC quantification with GNLC for the C3T scanner. STUDY TYPE: Phantom measurements and retrospective analysis of patient data. PHANTOM/SUBJECTS: A diffusion quality control phantom with vials containing 0-30% polyvinylpyrrolidone in water was used. For in vivo data, 12 patient exams were analyzed (median age, 33). FIELD STRENGTH/SEQUENCE: Imaging was performed on the C3T and two commercial 3T scanners. A clinical DWI (repetition time [TR] = 10,000 msec, echo time [TE] = minimum, b = 1000 s/mm2 ) sequence was used for phantom imaging and 10 patient cases and a clinical DTI (TR = 6000-10,000 msec, TE = minimum, b = 1000 s/mm2 ) sequence was used for two patient cases. ASSESSMENT: The 0% vial was measured along three orthogonal axes, and at two different temperatures. The ADC for each concentration was compared between the C3T and two whole-body scanners. Cerebrospinal fluid and white matter ADCs were quantified for each patient and compared to values in literature. STATISTICAL TESTS: Paired t-test and two-way analysis of variance (ANOVA). RESULTS: For all PVP concentrations, the corrected ADC was within 2.5% of the reference ADC. On average, the ADC of cerebrospinal fluid and white matter post-GNLC were within 1% and 6%, respectively, of values reported in the literature and were significantly different from the uncorrected data (P < 0.05). DATA CONCLUSION: This study demonstrated that GNL effects were more severe for the C3T due to the asymmetric gradient design, but our implementation of a GNLC compensated for these effects, resulting in ADC values that are in good agreement with values from the literature. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:1498-1507.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador/métodos , Adolescente , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Dinámicas no Lineales , Fantasmas de Imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
12.
Eur Radiol ; 28(3): 936-945, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28986646

RESUMEN

OBJECTIVES: To determine the diagnostic performance of MR elastography (MRE) and compare it with serum CA19-9 in differentiating malignant from benign pancreatic masses, with emphasis on differentiating between pancreatic ductal adenocarcinoma (PDAC) and mass-forming pancreatitis (MFP). METHODS: We performed a prospective, consecutive, 24-month study in 85 patients with solid pancreatic masses confirmed by histopathologic examinations. The mass stiffness and stiffness ratio (calculated as the ratio of mass stiffness to the parenchymal stiffness) were assessed. The diagnostic accuracy was analysed by calculating the area under the ROC curve (AUROC). RESULTS: The final diagnosis included 54 malignant tumours (43 patients with PDAC) and 31 benign masses (24 patients with MFP). The stiffness ratio showed better diagnostic performance than the mass stiffness and serum CA19-9 for the differentiation between malignant and benign masses (AUC: 0.912 vs. 0.845 vs. 0.702; P = 0.026, P < 0.001) and, specifically, between PDAC and MFP (AUC: 0.955 vs. 0.882 vs. 0.745; P = 0.026, P = 0.003). The sensitivity, specificity, and accuracy of stiffness ratio for the differentiation of PDAC and MFP were all higher than 0.9. CONCLUSIONS: MRE presents an effective and quantitative strategy for non-invasive differentiation between PDAC and MFP based on their mechanical properties. KEY POINTS: • 3D MRE is useful for calculating stiffness of solid pancreatic tumours. • Stiffness ratio outperformed stiffness and CA19-9 for differentiating PDAC from MFP. • Incorporation of 3D MRE into a standard MRI protocol is recommended.


Asunto(s)
Carcinoma Ductal Pancreático/diagnóstico , Imagen Eco-Planar/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Imagenología Tridimensional/métodos , Neoplasias Pancreáticas/diagnóstico , Pancreatitis/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Páncreas/diagnóstico por imagen , Estudios Prospectivos , Curva ROC , Neoplasias Pancreáticas
13.
Magn Reson Med ; 77(6): 2250-2262, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27373901

RESUMEN

PURPOSE: To develop a gradient pre-emphasis scheme that prospectively counteracts the effects of the first-order concomitant fields for any arbitrary gradient waveform played on asymmetric gradient systems, and to demonstrate the effectiveness of this approach using a real-time implementation on a compact gradient system. METHODS: After reviewing the first-order concomitant fields that are present on asymmetric gradients, we developed a generalized gradient pre-emphasis model assuming arbitrary gradient waveforms to counteract their effects. A numerically straightforward, easily implemented approximate solution to this pre-emphasis problem was derived that was compatible with the current hardware infrastructure of conventional MRI scanners for eddy current compensation. The proposed method was implemented on the gradient driver subsystem, and its real-time use was tested using a series of phantom and in vivo data acquired from two-dimensional Cartesian phase-difference, echo-planar imaging, and spiral acquisitions. RESULTS: The phantom and in vivo results demonstrated that unless accounted for, first-order concomitant fields introduce considerable phase estimation error into the measured data and result in images with spatially dependent blurring/distortion. The resulting artifacts were effectively prevented using the proposed gradient pre-emphasis. CONCLUSION: We have developed an efficient and effective gradient pre-emphasis framework to counteract the effects of first-order concomitant fields of asymmetric gradient systems. Magn Reson Med 77:2250-2262, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Algoritmos , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Humanos , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
14.
Am J Gastroenterol ; 111(6): 823-33, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26977760

RESUMEN

OBJECTIVES: Magnetic resonance elastography (MRE) with three-dimensional spin-echo echo planar imaging (3D-SE-EPI) is a newly emerging noninvasive method for assessing liver fibrosis. We hypothesized that 3D-SE-EPI might have better diagnostic accuracy than conventional two-dimensional gradient-recalled echo (2D-GRE). METHODS: We prospectively included 179 consecutive patients with chronic hepatitis B (CHB) or C (CHC) who underwent both MRE and liver biopsy. Liver stiffness was measured by both 3D-SE-EPI and 2D-GRE for staging biopsy-proven liver fibrosis (using METAVIR scores). A receiver-operating characteristic analysis using the area under the receiver-operating characteristic curve (AUC) was used to compare the diagnostic performance in predicting liver fibrosis between these two techniques, and compared them to serum markers of fibrosis. RESULTS: The technical failure rate of 3D-SE-EPI (2.2%, n=4/179) was lower compared with 2D-GRE (8.3%, n=15/179). The stiffness measured by 3D-SE-EPI was slightly lower compared with 2D-GRE, with the mean difference of 0.57 kPa (Bland and Altman plot, 95% limits of agreement: -0.32 and 1.45 kPa). AUCs for the characterization of ≥F1, ≥F2, ≥F3, and F4 were 0.957 (95% confidence interval (CI): 0.913-0.983), 0.971 (0.932-0.991), 0.991 (0.961-0.999), and 0.979 (0.942-0.995) for 3D-SE-EPI, which was slightly higher compared with the AUCs for 2D-GRE at each fibrosis stage (0.948 (0.901-0.977), 0.959 (0.915-0.981), 0.979 (0.943-0.995), and 0.976 (0.938-0.994), respectively), although none reached statistical significance (P=0.160-0.585). In an "intention-to-diagnose" analysis, the diagnostic accuracy (the proportion of well-classified patients) by EPI (86.7-91.3%, n=169) was higher compared with GRE (80.9-82.1%, n=158) after applying optimal cutoffs. Both 3D-SE-EPI and 2D-GRE performed better than serum fibrosis markers. CONCLUSIONS: With respect to 2D-GRE, 3D-SE-EPI has the advantage of lower failure rate with equivalent high diagnostic performance for staging liver fibrosis in CHB/CHC patients, and thus more helpful for those challenging cases in 2D-GRE.


Asunto(s)
Imagen Eco-Planar/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Hepatitis B Crónica/complicaciones , Hepatitis C Crónica/complicaciones , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/etiología , Adulto , Anciano , Biomarcadores/sangre , Biopsia , China , Estudios Transversales , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
15.
Magn Reson Med ; 75(6): 2534-44, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26183425

RESUMEN

PURPOSE: To describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction. METHODS: Starting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction. RESULTS: Phantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL-induced coarse-scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries. CONCLUSION: Noniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534-2544, 2016. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Dinámicas no Lineales , Encéfalo/diagnóstico por imagen , Análisis de Fourier , Humanos , Fantasmas de Imagen
16.
Magn Reson Med ; 74(4): 1019-31, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25298258

RESUMEN

PURPOSE: To describe a model-based reconstruction strategy for routine magnetic resonance imaging that accounts for gradient nonlinearity (GNL) during rather than after transformation to the image domain, and demonstrate that this approach reduces the spatial resolution loss that occurs during strictly image-domain GNL-correction. METHODS: After reviewing conventional GNL-correction methods, we propose a generic signal model for GNL-affected magnetic resonance imaging acquisitions, discuss how it incorporates into contemporary image reconstruction platforms, and describe efficient nonuniform fast Fourier transform-based computational routines for these. The impact of GNL-correction on spatial resolution by the conventional and proposed approaches is investigated on phantom data acquired at varying offsets from gradient isocenter, as well as on fully sampled and (retrospectively) undersampled in vivo acquisitions. RESULTS: Phantom results demonstrate that resolution loss that occurs during GNL-correction is significantly less for the proposed strategy than for the standard approach at distances >10 cm from isocenter with a 35 cm field-of-view gradient coil. The in vivo results suggest that the proposed strategy better preserves fine anatomical detail than retrospective GNL-correction while offering comparable geometric correction. CONCLUSION: Accounting for GNL during image reconstruction allows geometric distortion to be corrected with less spatial resolution loss than is typically observed with the conventional image domain correction strategy.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Análisis de Fourier , Cabeza/anatomía & histología , Humanos , Dinámicas no Lineales , Fantasmas de Imagen
17.
J Imaging Inform Med ; 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38639807

RESUMEN

Deep brain stimulation (DBS) is a method of electrical neuromodulation used to treat a variety of neuropsychiatric conditions including essential tremor, Parkinson's disease, epilepsy, and obsessive-compulsive disorder. The procedure requires precise placement of electrodes such that the electrical contacts lie within or in close proximity to specific target nuclei and tracts located deep within the brain. DBS electrode trajectory planning has become increasingly dependent on direct targeting with the need for precise visualization of targets. MRI is the primary tool for direct visualization, and this has led to the development of numerous sequences to aid in visualization of different targets. Synthetic inversion recovery images, specified by an inversion time parameter, can be generated from T1 relaxation maps, and this represents a promising method for modifying the contrast of deep brain structures to accentuate target areas using a single acquisition. However, there is currently no accessible method for dynamically adjusting the inversion time parameter and observing the effects in real-time in order to choose the optimal value. In this work, we examine three different approaches to implementing an application for real-time optimal synthetic inversion recovery image selection and evaluate them based on their ability to display continually-updated synthetic inversion recovery images as the user modifies the inversion time parameter. These methods include continuously computing the inversion recovery equation at each voxel in the image volume, limiting the computation only to the voxels of the orthogonal slices currently displayed on screen, or using a series of lookup tables with precomputed solutions to the inversion recovery equation. We find the latter implementation provides for the quickest display updates both when modifying the inversion time and when scrolling through the image. We introduce a publicly available cross-platform application built around this conclusion. We also briefly discuss other details of the implementations and considerations for extensions to other use cases.

18.
NPJ Parkinsons Dis ; 10(1): 13, 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38191546

RESUMEN

Parkinson's disease (PD) is a prevalent neurodegenerative disorder that presents a diagnostic challenge due to symptom overlap with other disorders. Neuromelanin (NM) imaging is a promising biomarker for PD, but adoption has been limited, in part due to subpar performance at standard MRI field strengths. We aimed to evaluate the diagnostic utility of ultra-high field 7T NM-sensitive imaging in the diagnosis of PD versus controls and essential tremor (ET), as well as NM differences among PD subtypes. A retrospective case-control study was conducted including PD patients, ET patients, and controls. 7T NM-sensitive 3D-GRE was acquired, and substantia nigra pars compacta (SNpc) volumes, contrast ratios, and asymmetry indices were calculated. Statistical analyses, including general linear models and ROC curves, were employed. Twenty-one PD patients, 13 ET patients, and 18 controls were assessed. PD patients exhibited significantly lower SNpc volumes compared to non-PD subjects. SNpc total volume showed 100% sensitivity and 96.8% specificity (AUC = 0.998) for differentiating PD from non-PD and 100% sensitivity and 95.2% specificity (AUC = 0.996) in differentiating PD from ET. Contrast ratio was not significantly different between PD and non-PD groups (p = 0.07). There was also significantly higher asymmetry index in SNpc volume in PD compared to non-PD cohorts (p < 0.001). NM signal loss in PD predominantly involved the inferior, posterior, and lateral aspects of SNpc. Akinetic-rigid subtype showed more significant NM signal loss compared to tremor dominant subtype (p < 0.001). 7T NM imaging demonstrates potential as a diagnostic tool for PD, including potential distinction between subtypes, allowing improved understanding of disease progression and subtype-related characteristics.

19.
Invest Radiol ; 59(7): 513-518, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38193790

RESUMEN

OBJECTIVES: Detection of infratentorial demyelinating lesions in multiple sclerosis (MS) presents a challenge in magnetic resonance imaging (MRI), a difficulty that is further heightened in 7 T MRI. This study aimed to assess the efficacy of a novel MRI approach, lesion-attenuated magnetization-prepared gradient echo acquisition (LAMA), for detecting demyelinating lesions within the posterior fossa and upper cervical spine on 7 T MRI and contrast its performance with conventional double-inversion recovery (DIR) and T2-weighted turbo spin echo sequences. MATERIALS AND METHODS: We conducted a retrospective cross-sectional study in 42 patients with a confirmed diagnosis of MS. All patients had 7 T MRI that incorporated LAMA, 3D DIR, and 2D T2-weighted turbo spin echo sequences. Three readers assessed lesion count in the brainstem, cerebellum, and upper cervical spinal cord using both DIR and T2-weighted images in one session. In a separate session, LAMA was analyzed alone. Contrast-to-noise ratio was also compared between LAMA and the conventional sequences. Lesion counts between methods were assessed using nonparametric Wilcoxon signed rank test. Interrater agreement in lesion detection was estimated by intraclass correlation coefficients. RESULTS: LAMA identified a significantly greater number of lesions than DIR + T2 (mean 6.4 vs 3.0; P < 0.001). LAMA also exhibited better interrater agreement (intraclass correlation coefficient [95% confidence interval], 0.75 [0.41-0.88] vs 0.61 [0.35-0.78]). The contrast-to-noise ratio for LAMA (3.7 ± 0.9) significantly exceeded that of DIR (1.94 ± 0.7) and T2 (1.2 ± 0.7) (all P 's < 0.001). In cases with no lesions detected using DIR + T2, at least 1 lesion was identified in 83.3% with LAMA. Across all analyzed brain regions, LAMA consistently detected more lesions than DIR + T2. CONCLUSIONS: LAMA significantly improves the detection of infratentorial demyelinating lesions in MS patients compared with traditional methods. Integrating LAMA with standard magnetization-prepared 2 rapid acquisition gradient echo acquisition provides a valuable tool for accurately characterizing the extent of MS disease.


Asunto(s)
Imagen por Resonancia Magnética , Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico por imagen , Femenino , Masculino , Adulto , Estudios Transversales , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Anciano
20.
J Neurosurg ; 141(1): 252-259, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38394660

RESUMEN

OBJECTIVE: The aim of this study was to compare outcomes of direct targeting in deep brain stimulation (DBS) for essential tremor using 7T MRI versus 3T MRI. The authors hypothesized that 7T MRI direct targeting would be noninferior to 3T MRI in early tremor outcomes. METHODS: A retrospective study was conducted on patients undergoing unilateral thalamic DBS for essential tremor between 2021 and 2023. Two matched cohorts were assessed, one using 7T MRI and the other using 3T MRI for surgical planning. The primary endpoint was the percentage improvement in the Fahn-Tolosa-Marin Tremor Rating Scale (TRS) scores. Additionally, the authors assessed optimized programming settings and variance in electrode position on postoperative imaging. Demographic and clinical data were compared using the nonparametric Mann-Whitney U-test. The squared Euclidean distance of each contact from the group mean centroid was calculated and averaged across the entire cohort to provide the variance (i.e., the mean squared distance) of electrode contact position. RESULTS: A total of 34 patients were analyzed, with 17 in each cohort. There were no significant differences in demographic information or mean surgical dates between the groups. There were no differences in intraoperative target repositioning or adverse events. The 7T group had a significantly greater TRS improvement than the 3T group (64.9% ± 11.4% vs 50.9% ± 16.4%, p = 0.004). Patients in the 7T cohort also had a lower mean stimulation current compared with those in the 3T cohort (2.0 ± 0.8 mA vs 2.7 ± 0.9 mA, p = 0.01). Image evaluation revealed that although the mean electrode position was comparable between 7T and 3T, the 7T electrode positioning was more clustered, indicating a lower variance in the final electrode location. The mean Euclidean distance between the individual electrode tips and the group centroid was significantly less at 7T than at 3T (1.82 ± 0.68 mm vs 2.75 ± 0.81 mm, p = 0.001). CONCLUSIONS: Despite concerns for increased artifacts and distortions at 7T, the authors show that these effects can be mitigated with an appropriate workflow, leading to improved surgical outcomes with direct targeting using 7T MRI. Their results suggest similar accuracy but greater precision in targeting with 7T MRI compared with 3T MRI, resulting in lower stimulation currents and improved tremor reduction. Future studies are needed to assess outcomes related to 7T MRI in targeting other subcortical structures.


Asunto(s)
Estimulación Encefálica Profunda , Temblor Esencial , Imagen por Resonancia Magnética , Humanos , Estimulación Encefálica Profunda/métodos , Temblor Esencial/terapia , Temblor Esencial/diagnóstico por imagen , Temblor Esencial/cirugía , Masculino , Femenino , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Tálamo/diagnóstico por imagen , Tálamo/cirugía , Electrodos Implantados