Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Electrophoresis ; 39(20): 2581-2589, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29772601

RESUMEN

In this work a hollow mesoporous structured molecularly imprinted polymer was synthetized and used as adsorbent in pipette-tip solid-phase extraction for the determination of lamivudine (3TC), zidovudine (AZT) and efavirenz (EFZ) from plasma of human immunodeficiency virus (HIV) infected patients by high-performance liquid chromatography (HPLC). All parameters that influence the recovery of the pipette tip based on hollow mesoporous molecularly imprinted polymer solid-phase extraction (PT-HM-MIP-SPE) method were systematically studied and discussed in detail. The adsorbent material was prepared using methacrylic acid and 4-vinylpyridine as functional monomers, ethylene glycol dimethacrylate as crosslinker, acetonitrile as solvent, 4,4'-azobis(4-cyanovaleric acid) as radical initiator, benzalkonium chloride as surfactant, 3TC, and AZT as templates. The simultaneous separation of 3TC, AZT and EFZ by HPLC-UV was performed using a Gemini C18 Phenomenex® column (250 mm × 4.6 mm, 5 µm) and mobile phase consisting of acetonitrile: water pH 3.2 (68:32, v/v), flow rate of 1.0 mL/min and λ = 260 nm. The method was linear over the concentration range from 0.25 to 10 µg/mL for 3TC and EFZ, and 0.05 to 2.0 µg mL-1 for AZT, with correlation coefficients larger than 0.99 for all analytes. Recovery ± relative standard deviations (RSDs %) were 41.99 ± 2.38%, 82.29 ± 1.63%, and 83.72 ± 7.52% for 3TC, AZT, and EFZ, respectively. The RSDs and relative errors (REs) were lower than 15% for intra and interday assays. The method has been successfully applied for monitoring HIV-infected patients outside the therapeutic dosage.


Asunto(s)
Antirretrovirales/sangre , Infecciones por VIH/tratamiento farmacológico , Impresión Molecular/métodos , Extracción en Fase Sólida/métodos , Antirretrovirales/aislamiento & purificación , Antirretrovirales/uso terapéutico , Cromatografía Líquida de Alta Presión , Humanos , Límite de Detección , Modelos Lineales , Reproducibilidad de los Resultados
2.
Food Chem ; 345: 128745, 2021 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-33302105

RESUMEN

In this work, we report the synthesis of a mesoporous molecularly imprinted polymer on the surface of silica nanoparticles (core@mMIP) to be applied as adsorbent in microextraction by packed sorbent (MEPS) for selective determination of pesticides in apple juice. The core@mMIP was properly characterized, showing good adhesion of the polymer to the silica core. The best extraction conditions were: 200 µL of ultrapure water as washing solvent, 150 µL of acetonitrile as eluent, 100 µL of sample at pH 2.5, five draw-eject cycles and 8 mg of adsorbent. Thereby, recoveries of 96.12 ± 1.05%, 76.88 ± 6.18% and 76.18 ± 5.57% were obtained for pyriproxyfen (PPX), deltamethrin (DTM) and etofenprox (ETF), respectively. After validation, the method presented linearity in the range of 0.02-10 µg mL-1 (r > 0.99), limit of detection of 0.005 µg mL-1, satisfactory selectivity, and proper precision and accuracy. The method was successfully applied real samples of processed and fresh apple juice.


Asunto(s)
Análisis de los Alimentos/métodos , Jugos de Frutas y Vegetales/análisis , Malus/química , Nanopartículas/química , Residuos de Plaguicidas/análisis , Residuos de Plaguicidas/aislamiento & purificación , Dióxido de Silicio/química , Adsorción , Contaminación de Alimentos/análisis , Polímeros Impresos Molecularmente/química , Porosidad , Solventes/química , Agua/química
3.
Braz. J. Pharm. Sci. (Online) ; 58: e19587, 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1384015

RESUMEN

This work aims to develop analytical methods using high-performance liquid chromatography with a diode array detector (HPLC-DAD) for analysis and quantification of avermectins (AVMs) and milbemycins (MBMs) in bulk samples. First, the methods were optimized and some parameters such as temperature, flow rate, injection volume and mobile phase with different proportions of solvents were evaluated. The best chromatographic conditions were obtained using the Phenomenex® C18 (150 × 4.60 mm, 5 µm) column at a temperature of 20 °C, flow rate of 1.2 mL min-1, injection volume of 20 µL, and detection at 250 nm. Acetonitrile: ultrapure water (87: 13, v/v) was used as mobile phase for moxidectin and eprinomectin, and acetonitrile: methanol: ultrapure water (53: 35: 12, v/v/v) for abamectin and ivermectin. Under these conditions satisfactory results were obtained, with appropriate limits of detection and quantification, acceptable linearity, precision, accuracy, and robustness. These methods satisfy the need for analytical methods for the multi-determination of MBMs and the B1a and B1b forms of AVMs by HPLC-DAD, which can be considered simple, effective, innovative and should aid in the development of the fiel


Asunto(s)
Métodos de Análisis de Laboratorio y de Campo , Cromatografía Líquida de Alta Presión/métodos , Estudio de Validación , Control de Calidad , Ivermectina/efectos adversos , Métodos de Análisis de Laboratorio y de Campo , Inseminación Artificial Heteróloga/clasificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA