1.
NMR Biomed ; 36(8): e4923, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36914278

RESUMEN

Hyperpolarized 129 Xe MRI (Xe-MRI) is increasingly used to image the structure and function of the lungs. Because 129 Xe imaging can provide multiple contrasts (ventilation, alveolar airspace size, and gas exchange), imaging often occurs over several breath-holds, which increases the time, expense, and patient burden of scans. We propose an imaging sequence that can be used to acquire Xe-MRI gas exchange and high-quality ventilation images within a single, approximately 10 s, breath-hold. This method uses a radial one-point Dixon approach to sample dissolved 129 Xe signal, which is interleaved with a 3D spiral ("FLORET") encoding pattern for gaseous 129 Xe. Thus, ventilation images are obtained at higher nominal spatial resolution (4.2 × 4.2 × 4.2 mm3 ) compared with gas-exchange images (6.25 × 6.25 × 6.25 mm3 ), both competitive with current standards within the Xe-MRI field. Moreover, the short 10 s Xe-MRI acquisition time allows for 1 H "anatomic" images used for thoracic cavity masking to be acquired within the same breath-hold for a total scan time of about 14 s. Images were acquired using this single-breath method in 11 volunteers (N = 4 healthy, N = 7 post-acute COVID). For 11 of these participants, a separate breath-hold was used to acquire a "dedicated" ventilation scan and five had an additional "dedicated" gas exchange scan. The images acquired using the single-breath protocol were compared with those from dedicated scans using Bland-Altman analysis, intraclass correlation (ICC), structural similarity, peak signal-to-noise ratio, Dice coefficients, and average distance. Imaging markers from the single-breath protocol showed high correlation with dedicated scans (ventilation defect percent, ICC = 0.77, p = 0.01; membrane/gas, ICC = 0.97, p = 0.001; red blood cell/gas, ICC = 0.99, p < 0.001). Images showed good qualitative and quantitative regional agreement. This single-breath protocol enables the collection of essential Xe-MRI information within one breath-hold, simplifying scanning sessions and reducing costs associated with Xe-MRI.


Asunto(s)
COVID-19 , Isótopos de Xenón , Humanos , Pulmón/diagnóstico por imagen , Respiración , Contencion de la Respiración , Imagen por Resonancia Magnética/métodos , Gases
2.
NMR Biomed ; 35(3): e4639, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34729838

RESUMEN

RATIONALE: Hyperpolarized (HP) 129 Xe-MRI provides non-invasive methods to quantify lung function and structure, with the 129 Xe apparent diffusion coefficient (ADC) being a well validated measure of alveolar airspace size. However, the experimental factors that impact the precision and accuracy of HP 129 Xe ADC measurements have not been rigorously investigated. Here, we introduce an analytical model to predict the experimental uncertainty of 129 Xe ADC estimates. Additionally, we report ADC dependence on age in healthy pediatric volunteers. METHODS: An analytical expression for ADC uncertainty was derived from the Stejskal-Tanner equation and simplified Bloch equations appropriate for HP media. Parameters in the model were maximum b-value (bmax ), number of b-values (Nb ), number of phase encoding lines (Nph ), flip angle and the ADC itself. This model was validated by simulations and phantom experiments, and five fitting methods for calculating ADC were investigated. To examine the lower range for 129 Xe ADC, 32 healthy subjects (age 6-40 years) underwent diffusion-weighted 129 Xe MRI. RESULTS: The analytical model provides a lower bound on ADC uncertainty and predicts that decreased signal-to-noise ratio yields increases in relative uncertainty (ϵADC) . As such, experimental parameters that impact non-equilibrium 129 Xe magnetization necessarily impact the resulting ϵADC . The values of diffusion encoding parameters (Nb and bmax ) that minimize ϵADC strongly depend on the underlying ADC value, resulting in a global minimum for ϵADC . Bayesian fitting outperformed other methods (error < 5%) for estimating ADC. The whole-lung mean 129 Xe ADC of healthy subjects increased with age at a rate of 1.75 × 10-4  cm2 /s/yr (p = 0.001). CONCLUSIONS: HP 129 Xe diffusion MRI can be improved by minimizing the uncertainty of ADC measurements via uncertainty propagation. Doing so will improve experimental accuracy when measuring lung microstructure in vivo and should allow improved monitoring of regional disease progression and assessment of therapy response in a range of lung diseases.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Pulmón/diagnóstico por imagen , Isótopos de Xenón , Adolescente , Adulto , Factores de Edad , Niño , Difusión , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Relación Señal-Ruido , Incertidumbre , Adulto Joven
3.
Magn Reson Med ; 86(6): 2966-2986, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34478584

RESUMEN

Hyperpolarized (HP) 129 Xe MRI uniquely images pulmonary ventilation, gas exchange, and terminal airway morphology rapidly and safely, providing novel information not possible using conventional imaging modalities or pulmonary function tests. As such, there is mounting interest in expanding the use of biomarkers derived from HP 129 Xe MRI as outcome measures in multi-site clinical trials across a range of pulmonary disorders. Until recently, HP 129 Xe MRI techniques have been developed largely independently at a limited number of academic centers, without harmonizing acquisition strategies. To promote uniformity and adoption of HP 129 Xe MRI more widely in translational research, multi-site trials, and ultimately clinical practice, this position paper from the 129 Xe MRI Clinical Trials Consortium (https://cpir.cchmc.org/XeMRICTC) recommends standard protocols to harmonize methods for image acquisition in HP 129 Xe MRI. Recommendations are described for the most common HP gas MRI techniques-calibration, ventilation, alveolar-airspace size, and gas exchange-across MRI scanner manufacturers most used for this application. Moreover, recommendations are described for 129 Xe dose volumes and breath-hold standardization to further foster consistency of imaging studies. The intention is that sites with HP 129 Xe MRI capabilities can readily implement these methods to obtain consistent high-quality images that provide regional insight into lung structure and function. While this document represents consensus at a snapshot in time, a roadmap for technical developments is provided that will further increase image quality and efficiency. These standardized dosing and imaging protocols will facilitate the wider adoption of HP 129 Xe MRI for multi-site pulmonary research.


Asunto(s)
Pulmón , Isótopos de Xenón , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Multicéntricos como Asunto , Ventilación Pulmonar , Respiración
4.
Am J Respir Crit Care Med ; 202(4): 524-534, 2020 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-32510976

RESUMEN

Rationale: Adverse events have limited the use of bronchial thermoplasty (BT) in severe asthma.Objectives: We sought to evaluate the effectiveness and safety of using 129Xe magnetic resonance imaging (129Xe MRI) to prioritize the most involved airways for guided BT.Methods: Thirty subjects with severe asthma were imaged with volumetric computed tomography and 129Xe MRI to quantitate segmental ventilation defects. Subjects were randomized to treatment of the six most involved airways in the first session (guided group) or a standard three-session BT (unguided). The primary outcome was the change in Asthma Quality of Life Questionnaire score from baseline to 12 weeks after the first BT for the guided group compared with after three treatments for the unguided group.Measurements and Main Results: There was no significant difference in quality of life after one guided compared with three unguided BTs (change in Asthma Quality of Life Questionnaire guided = 0.91 [95% confidence interval, 0.28-1.53]; unguided = 1.49 [95% confidence interval, 0.84-2.14]; P = 0.201). After one BT, the guided group had a greater reduction in the percentage of poorly and nonventilated lung from baseline when compared with unguided (-17.2%; P = 0.009). Thirty-three percent experienced asthma exacerbations after one guided BT compared with 73% after three unguided BTs (P = 0.028).Conclusions: Results of this pilot study suggest that similar short-term improvements can be achieved with one BT treatment guided by 129Xe MRI when compared with standard three-treatment-session BT with fewer periprocedure adverse events.


Asunto(s)
Asma/cirugía , Termoplastia Bronquial/métodos , Imagen por Resonancia Magnética/métodos , Cirugía Asistida por Computador , Isótopos de Xenón/uso terapéutico , Adulto , Termoplastia Bronquial/efectos adversos , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Calidad de Vida , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
5.
NMR Biomed ; 33(7): e4302, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32285574

RESUMEN

Fast apparent transverse relaxation (short T2 *) is a common obstacle when attempting to perform quantitative 1 H MRI of the lungs. While T2 * times are longer for pulmonary hyperpolarized (HP) gas functional imaging (in particular for gaseous 129 Xe), T2 * can still lead to quantitative inaccuracies for sequences requiring longer echo times (such as diffusion weighted images) or longer readout duration (such as spiral sequences). This is especially true in preclinical studies, where high magnetic fields lead to shorter relaxation times than are typically seen in human studies. However, the T2 * of HP 129 Xe in the most common animal model of human disease (mice) has not been reported. Herein, we present a multi-echo radial flyback imaging sequence and use it to measure HP 129 Xe T2 * at 7 T under a variety of respiratory conditions. This sequence mitigates the impact of T1 relaxation outside the animal by using multiple gradient-refocused echoes to acquire images at a number of effective echo times for each RF excitation. After validating the sequence using a phantom containing water doped with superparamagnetic iron oxide nanoparticles, we measured the 129 Xe T2 * in vivo for 10 healthy C57Bl/6 J mice and found T2 * ~ 5 ms in the lung airspaces. Interestingly, T2 * was relatively constant over all experimental conditions, and varied significantly with sex, but not age, mass, or the O2 content of the inhaled gas mixture. These results are discussed in the context of T2 * relaxation within porous media.


Asunto(s)
Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Respiración , Isótopos de Xenón/química , Animales , Femenino , Procesamiento de Imagen Asistido por Computador , Masculino , Ratones Endogámicos C57BL , Fantasmas de Imagen
6.
Magn Reson Med ; 77(1): 265-272, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-26778748

RESUMEN

PURPOSE: Chronic obstructive pulmonary disease (COPD) is an irreversible lung disease characterized by small-airway obstruction and alveolar-airspace destruction. Hyperpolarized 129 Xe diffusion MRI of lung is a promising biomarker for assessing airspace enlargement, but has yet to be validated by direct comparison to lung histology. Here we have compared diffusion measurements of hyperpolarized (HP) 129 Xe in explanted lungs to regionally matched morphological measures of airspace size. METHODS: Explanted lungs from five COPD patients and two idiopathic pulmonary fibrosis (IPF) patients were imaged using MRI with hyperpolarized 129 Xe using a two-b-value gradient-echo diffusion sequence, and 34 histological samples were taken from these lungs for quantitative histology. Mean-linear-intercept (Lm ) was compared with spatially matched measures of apparent diffusion coefficient (ADC) from 129 Xe MRI. RESULTS: The mean ADC from COPD lung samples was 0.071 ± 0.011 cm2 /s, and for IPF lungs was 0.033 ± 0.001 cm2 /s (P < 10-15 between groups). The mean Lm in COPD samples was 0.076 ± 0.027 cm and 0.041 ± 0.004 cm in IPF (P = 2.7 × 10-7 between groups). The Pearson-correlation between ADC and Lm measurements was r = 0.59. CONCLUSIONS: Diffusion MRI of HP 129 Xe quantifies regional airspace enlargement in COPD. 129 Xe ADC showed much less overlap between groups than quantitative histology, consistent with our past experience with 3 He diffusion MRI in COPD. Magn Reson Med 77:265-272, 2017. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Histocitoquímica/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/diagnóstico por imagen , Isótopos de Xenón/química , Adulto , Anciano , Femenino , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Pulmón/química , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen
7.
Magn Reson Med ; 77(3): 1284-1295, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-26972576

RESUMEN

PURPOSE: To implement pulmonary three-dimensional (3D) radial ultrashort echo-time (UTE) MRI in non-sedated, free-breathing neonates and adults with retrospective motion tracking of respiratory and intermittent bulk motion, to obtain diagnostic-quality, respiratory-gated images. METHODS: Pulmonary 3D radial UTE MRI was performed at 1.5 tesla (T) during free breathing in neonates and adult volunteers for validation. Motion-tracking waveforms were obtained from the time course of each free induction decay's initial point (i.e., k-space center), allowing for respiratory-gated image reconstructions that excluded data acquired during bulk motion. Tidal volumes were calculated from end-expiration and end-inspiration images. Respiratory rates were calculated from the Fourier transform of the motion-tracking waveform during quiet breathing, with comparison to physiologic prediction in neonates and validation with spirometry in adults. RESULTS: High-quality respiratory-gated anatomic images were obtained at inspiration and expiration, with less respiratory blurring at the expense of signal-to-noise for narrower gating windows. Inspiration-expiration volume differences agreed with physiologic predictions (neonates; Bland-Altman bias = 6.2 mL) and spirometric values (adults; bias = 0.11 L). MRI-measured respiratory rates compared well with the observed rates (biases = -0.5 and 0.2 breaths/min for neonates and adults, respectively). CONCLUSIONS: Three-dimensional radial pulmonary UTE MRI allows for retrospective respiratory self-gating and removal of intermittent bulk motion in free-breathing, non-sedated neonates and adults. Magn Reson Med 77:1284-1295, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Artefactos , Displasia Broncopulmonar/diagnóstico por imagen , Hernia Diafragmática/diagnóstico por imagen , Aumento de la Imagen/métodos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto , Algoritmos , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Recién Nacido , Masculino , Movimiento (Física) , Reproducibilidad de los Resultados , Mecánica Respiratoria , Estudios Retrospectivos , Sensibilidad y Especificidad , Técnica de Sustracción
8.
J Magn Reson Imaging ; 45(2): 463-471, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27458992

RESUMEN

PURPOSE: To determine the feasibility of pulmonary magnetic resonance imaging (MRI) of neonatal lung structures enabled by combining two novel technologies: first, a 3D radial ultrashort echo time (UTE) pulse sequence capable of high spatial resolution full-chest imaging in nonsedated quiet-breathing neonates; and second, a unique, small-footprint 1.5T MRI scanner design adapted for neonatal imaging and installed within the neonatal intensive care unit (NICU). MATERIALS AND METHODS: Ten patients underwent MRI within the NICU, in accordance with an approved Institutional Review Board protocol. Five had clinical diagnoses of bronchopulmonary dysplasia (BPD), and five had putatively normal lung function. Pulmonary imaging was performed at 1.5T using 3D radial UTE and standard 3D fast gradient recalled echo (FGRE). Diagnostic quality, presence of motion artifacts, and apparent severity of lung pathology were evaluated by two radiologists. Quantitative metrics were additionally used to evaluate lung parenchymal signal. RESULTS: UTE images showed significantly higher signal in lung parenchyma (P < 0.0001) and fewer apparent motion artifacts compared to FGRE (P = 0.046). Pulmonary pathology was more severe in patients diagnosed with BPD relative to controls (P = 0.001). Infants diagnosed with BPD also had significantly higher signal in lung parenchyma, measured using UTE, relative to controls (P = 0.002). CONCLUSION: These results demonstrate the technical feasibility of pulmonary MRI in free-breathing, nonsedated infants in the NICU at high, isotropic resolutions approaching that achievable with computed tomography (CT). There is potential for pulmonary MRI to play a role in improving how clinicians understand and manage care of neonatal and pediatric pulmonary diseases. J. Magn. Reson. Imaging 2016. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:463-471.


Asunto(s)
Imagenología Tridimensional/instrumentación , Unidades de Cuidado Intensivo Neonatal , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Femenino , Humanos , Aumento de la Imagen/instrumentación , Masculino , Miniaturización , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
J Magn Reson Imaging ; 46(4): 992-1000, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28160357

RESUMEN

PURPOSE: To demonstrate that ultrashort echo time (UTE) magnetic resonance imaging (MRI) can achieve computed tomography (CT)-like quantification of lung parenchyma in free-breathing, non-sedated neonates. Because infant CTs are used sparingly, parenchymal disease evaluation via UTE MRI has potential for translational impact. MATERIALS AND METHODS: Two neonatal control cohorts without suspected pulmonary morbidities underwent either a research UTE MRI (n = 5; 1.5T) or a clinically-ordered CT (n = 9). Whole-lung means and anterior-posterior gradients of UTE-measured image intensity (arbitrary units, au, normalized to muscle) and CT-measured density (g/cm3 ) were compared (Mann-Whitney U-test). Separately, a diseased neonatal cohort (n = 5) with various pulmonary morbidities underwent both UTE MRI and CT. UTE intensity and CT density were compared with Spearman correlations within ∼33 anatomically matched regions of interest (ROIs) in each diseased subject, spanning low- to high-density tissues. Radiological classifications were evaluated in all ROIs, with mean UTE intensities and CT densities compared in each classification. RESULTS: In control subjects, whole-lung UTE intensities (0.51 ± 0.04 au) were similar to CT densities (0.44 ± 0.09 g/cm3 ) (P = 0.062), as were UTE (0.021 ± 0.020 au/cm) and CT (0.034 ± 0.024 [g/cm3 ]/cm) anterior-posterior gradients (P = 0.351). In diseased subjects' ROIs, significant correlations were observed between UTE and CT (P ≤0.007 in each case). Relative differences between UTE and CT were small in all classifications (4-25%). CONCLUSION: These results demonstrate a strong association between UTE image intensity and CT density, both between whole-lung tissue in control patients and regional radiological pathologies in diseased patients. This indicates the potential for UTE MRI to longitudinally evaluate neonatal pulmonary disease and to provide visualization of pathologies similar to CT, without sedation/anesthesia or ionizing radiation. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:992-1000.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Enfermedades Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Recién Nacido , Pulmón/anatomía & histología , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
J Magn Reson Imaging ; 44(6): 1656-1663, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27185386

RESUMEN

PURPOSE: To further validate the ability of ultrashort echo-time (UTE) magnetic resonance imaging (MRI) in quantifying lung density in patients diagnosed with chronic obstructive pulmonary disease (COPD) and to develop an MRI-based emphysema index (EI). MATERIALS AND METHODS: Ten subjects clinically diagnosed with COPD (5M/5F, age 62.6 ± 8.5 years) and ten healthy subjects (2M/8F, age 48.9 ± 19.2 years) were imaged via UTE MRI at 3T (4 mm slices, 1.39 × 1.39 mm2 pixels). Chest computed tomography (CT) images (generally 5 mm slices, ≈0.55 × 0.55 mm2 pixels), acquired retrospectively, were compared to UTE MRI. CT lung densities, MR lung-signal density, and EI were quantified from both CT and UTE MR images via a quantitative automated analysis and compared to the percent predicted forced expiratory volume in 1 second (FEV1 % predicted). RESULTS: EI quantified in controls via CT and UTE MRI was 0.23 ± 0.78% and 2.40 ± 1.50%, respectively; in COPD subjects it was 13.3 ± 14.9% (P = 0.021) and 12.0 ± 9.8% (P = 0.013), respectively. Bland-Altman determined the mean differences and 95% limits of agreement for COPD subjects and healthy controls were 0.06 (12.50 to -12.38). Strong correlation (R2 = 0.79, P < 0.0001) existed between EIs quantified from both CT and UTE MRI. There was a slightly higher correlation between FEV1 % predicted and the UTE MRI EI (R2 = 0.65, P < 0.0001) compared to CT EI (R2 = 0.49, P < 0.0001). CONCLUSION: Our results demonstrate a significant positive correlation between lung density and EI assessed with CT and MRI. Furthermore, UTE MRI exhibits its potential as a diagnostic alternative to CT for assessing the extent and the severity of emphysema, particularly for longitudinal studies. J. Magn. Reson. Imaging 2016;44:1656-1663.


Asunto(s)
Densitometría/métodos , Enfisema/patología , Enfisema/fisiopatología , Imagen por Resonancia Magnética/métodos , Enfermedad Pulmonar Obstructiva Crónica/patología , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Anciano , Enfisema/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Am J Respir Crit Care Med ; 192(10): 1215-22, 2015 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-26186608

RESUMEN

RATIONALE: Bronchopulmonary dysplasia (BPD) is a prevalent yet poorly characterized pulmonary complication of premature birth; the current definition is based solely on oxygen dependence at 36 weeks postmenstrual age without objective measurements of structural abnormalities across disease severity. OBJECTIVES: We hypothesize that magnetic resonance imaging (MRI) can spatially resolve and quantify the structural abnormalities of the neonatal lung parenchyma associated with premature birth. METHODS: Using a unique, small-footprint, 1.5-T MRI scanner within our neonatal intensive care unit (NICU), diagnostic-quality MRIs using commercially available sequences (gradient echo and spin echo) were acquired during quiet breathing in six patients with BPD, six premature patients without diagnosed BPD, and six full-term NICU patients (gestational ages, 23-39 wk) at near term-equivalent age, without administration of sedation or intravenous contrast. Images were scored by a radiologist using a modified Ochiai score, and volumes of high- and low-signal intensity lung parenchyma were quantified by segmentation and threshold analysis. MEASUREMENTS AND MAIN RESULTS: Signal increases, putatively combinations of fibrosis, edema, and atelectasis, were present in all premature infants. Infants with diagnosed BPD had significantly greater volume of high-signal lung (mean ± SD, 26.1 ± 13.8%) compared with full-term infants (7.3 ± 8.2%; P = 0.020) and premature infants without BPD (8.2 ± 6.4%; P = 0.026). Signal decreases, presumably alveolar simplification, only appeared in the most severe BPD cases, although cystic appearance did increase with severity. CONCLUSIONS: Pulmonary MRI reveals quantifiable, significant differences between patients with BPD, premature patients without BPD, and full-term control subjects. These methods could be implemented to individually phenotype disease, which may impact clinical care and predict future outcomes.


Asunto(s)
Displasia Broncopulmonar/patología , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Displasia Broncopulmonar/diagnóstico , Femenino , Humanos , Recién Nacido , Recien Nacido Prematuro , Recién Nacido de muy Bajo Peso , Unidades de Cuidado Intensivo Neonatal , Imagen por Resonancia Magnética/instrumentación
13.
Pediatr Radiol ; 46(12): 1651-1662, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27492388

RESUMEN

BACKGROUND: Hyperpolarized 129Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. OBJECTIVE: To assess the feasibility, safety and tolerability of hyperpolarized 129Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. MATERIALS AND METHODS: Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent 129Xe MRI, receiving up to three doses of 129Xe gas prepared by either a commercially available or a homebuilt 129Xe polarizer. Subject heart rate and SpO2 were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. RESULTS: All children tolerated multiple doses of 129Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO2 (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO2 values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following 129Xe MRI, but all were deemed unrelated to the study. CONCLUSION: The feasibility, safety and tolerability of 129Xe MRI has been assessed in a small group of children as young as 6 years. SpO2 changes were consistent with the expected physiological effects of a short anoxic breath-hold, and other mild side effects were consistent with the known anesthetic properties of xenon and with previous safety assessments of 129Xe MRI in adults. Hyperpolarized 129Xe is a safe and well-tolerated inhaled contrast agent for pulmonary MR imaging in healthy children and in children with cystic fibrosis who have mild to moderate lung disease.


Asunto(s)
Medios de Contraste/efectos adversos , Fibrosis Quística/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Niño , Estudios de Factibilidad , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Isótopos de Xenón/efectos adversos
14.
Radiology ; 274(1): 250-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25144646

RESUMEN

PURPOSE: To quantify regional lung ventilation in healthy volunteers and patients with severe asthma (both before and after thermoplasty) by using a combination of helium 3 ((3)He) magnetic resonance (MR) imaging and computed tomography (CT), with the intention of developing more effective image-guided treatments for obstructive lung diseases. MATERIALS AND METHODS: With approval of the local institutional review board, informed consent, and an Investigational New Drug Exemption, six healthy volunteers and 10 patients with severe asthma were imaged in compliance with HIPAA regulations by using both multidetector CT and (3)He MR imaging. Individual bronchopulmonary segments were labeled voxel by voxel from the CT images and then registered to the (3)He MR images by using custom software. The (3)He signal intensity was then analyzed by evaluating the volume-weighted fraction of total-lung signal intensity present in each segment (segmental ventilation percentage [ SVP segmental ventilation percentage ]) and by identifying the whole-lung defect percentage and the segmental defect percentage. Of the 10 patients with asthma, seven received treatment with bronchial thermoplasty and were imaged with (3)He MR a second time. Changes in segmental defect percentages and whole-lung defect percentages are presented. RESULTS: Ventilation measures for healthy volunteers yielded smaller segment-to-segment variation (mean SVP segmental ventilation percentage , 100% ± 18 [standard deviation]) than did the measures for patients with severe asthma (mean SVP segmental ventilation percentage , 97% ± 23). Patients with asthma also demonstrated larger segmental defect percentages (median, 13.5%; interquartile range, 8.9%-17.8%) than healthy volunteers (median, 6%; interquartile range, 5.6%-6.3%). These quantitative results confirm what is visually observed on the (3)He images. A Spearman correlation of r = -0.82 was found between the change in whole-lung defect percentage and the number of days between final treatment and second (3)He imaging. CONCLUSION: Regional quantification of lung ventilation is indeed feasible and may be a useful technique for image-guided treatment of obstructive lung diseases, such as bronchial thermoplasty for severe asthma. In these patients, ventilation defects decreased as a function of time after treatment.


Asunto(s)
Asma/fisiopatología , Asma/cirugía , Ablación por Catéter/métodos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Asma/diagnóstico por imagen , Femenino , Helio , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Resultado del Tratamiento
15.
Magn Reson Med ; 73(5): 1970-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24954886

RESUMEN

PURPOSE: To demonstrate that longitudinal, noninvasive monitoring via MRI can characterize acute cellular rejection in mouse orthotopic lung allografts. METHODS: Nineteen Balb/c donor to C57BL/6 recipient orthotopic left lung transplants were performed, further divided into control-Ig versus anti-CD4/anti-CD8 treated groups. A two-dimensional multislice gradient-echo pulse sequence synchronized with ventilation was used on a small-animal MR scanner to acquire proton images of lung at postoperative days 3, 7, and 14, just before sacrifice. Lung volume and parenchymal signal were measured, and lung compliance was calculated as volume change per pressure difference between high and low pressures. RESULTS: Normalized parenchymal signal in the control-Ig allograft increased over time, with statistical significance between day 14 and day 3 posttransplantation (0.046→0.789; P < 0.05), despite large intermouse variations; this was consistent with histopathologic evidence of rejection. Compliance of the control-Ig allograft decreased significantly over time (0.013→0.003; P < 0.05), but remained constant in mice treated with anti-CD4/anti-CD8 antibodies. CONCLUSION: Lung allograft rejection in individual mice can be monitored by lung parenchymal signal changes and by lung compliance through MRI. Longitudinal imaging can help us better understand the time course of individual lung allograft rejection and response to treatment.


Asunto(s)
Rechazo de Injerto/patología , Trasplante de Pulmón , Pulmón/patología , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Aloinjertos , Animales , Anticuerpos Monoclonales/farmacología , Antígenos CD4/inmunología , Antígenos CD8/inmunología , Rechazo de Injerto/inmunología , Estudios Longitudinales , Pulmón/inmunología , Rendimiento Pulmonar/efectos de los fármacos , Rendimiento Pulmonar/fisiología , Masculino , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C57BL , Tamaño de los Órganos/efectos de los fármacos , Tamaño de los Órganos/fisiología
16.
PLoS One ; 16(8): e0256460, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34411195

RESUMEN

Computational fluid dynamics (CFD) simulations of respiratory airflow have the potential to change the clinical assessment of regional airway function in health and disease, in pulmonary medicine and otolaryngology. For example, in diseases where multiple sites of airway obstruction occur, such as obstructive sleep apnea (OSA), CFD simulations can identify which sites of obstruction contribute most to airway resistance and may therefore be candidate sites for airway surgery. The main barrier to clinical uptake of respiratory CFD to date has been the difficulty in validating CFD results against a clinical gold standard. Invasive instrumentation of the upper airway to measure respiratory airflow velocity or pressure can disrupt the airflow and alter the subject's natural breathing patterns. Therefore, in this study, we instead propose phase contrast (PC) velocimetry magnetic resonance imaging (MRI) of inhaled hyperpolarized 129Xe gas as a non-invasive reference to which airflow velocities calculated via CFD can be compared. To that end, we performed subject-specific CFD simulations in airway models derived from 1H MRI, and using respiratory flowrate measurements acquired synchronously with MRI. Airflow velocity vectors calculated by CFD simulations were then qualitatively and quantitatively compared to velocity maps derived from PC velocimetry MRI of inhaled hyperpolarized 129Xe gas. The results show both techniques produce similar spatial distributions of high velocity regions in the anterior-posterior and foot-head directions, indicating good qualitative agreement. Statistically significant correlations and low Bland-Altman bias between the local velocity values produced by the two techniques indicates quantitative agreement. This preliminary in vivo comparison of respiratory airway CFD and PC MRI of hyperpolarized 129Xe gas demonstrates the feasibility of PC MRI as a technique to validate respiratory CFD and forms the basis for further comprehensive validation studies. This study is therefore a first step in the pathway towards clinical adoption of respiratory CFD.


Asunto(s)
Isótopos de Xenón , Humanos , Hidrodinámica , Imagen por Resonancia Magnética , Tráquea
17.
PLoS One ; 15(10): e0240265, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33031412

RESUMEN

Adolescent idiopathic scoliosis (AIS) is associated with decreased respiratory quality of life and impaired diaphragm function. Recent hyperpolarized helium (HHe) MRI studies show alveolarization continues throughout adolescence, and mechanical forces are known to impact alveolarization. We therefore hypothesized that patients with AIS would have alterations in alveolar size, alveolar number, or alveolar septal dimensions compared to adolescents without AIS, and that posterior spinal fusion (PSF) might reverse these differences. We conducted a prospective observational trial using HHe MRI to test for changes in alveolar microstructure in control and AIS subjects at baseline and one year. After obtaining written informed consent from subjects' legal guardians and assent from the subjects, we performed HHe and proton MRI in 14 AIS and 16 control subjects aged 8-21 years. The mean age of control subjects (12.9 years) was significantly less than AIS (14.9 years, p = 0.003). At baseline, there were no significant differences in alveolar size, number, or alveolar duct morphometry between AIS and control subjects or between the concave (compressed) and convex (expanded) lungs of AIS subjects. At one year after PSF AIS subjects had an increase in alveolar density in the formerly convex lung (p = 0.05), likely reflecting a change in thoracic anatomy, but there were no other significant changes in lung microstructure. Modeling of alveolar size over time demonstrated similar rates of alveolar growth in control and AIS subjects in both right and left lungs pre- and post-PSF. Although this study suffered from poor age-matching, we found no evidence that AIS or PSF impacts lung microstructure. Trial registration: Clinical trial registration number NCT03539770.


Asunto(s)
Pulmón/patología , Escoliosis/patología , Escoliosis/terapia , Fusión Vertebral , Adolescente , Estudios de Casos y Controles , Niño , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Masculino , Escoliosis/diagnóstico por imagen , Resultado del Tratamiento , Adulto Joven
18.
Neonatology ; 117(6): 704-712, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33176330

RESUMEN

BACKGROUND: Alveolar development and lung parenchymal simplification are not well characterized in vivo in neonatal patients with respiratory morbidities, such as bronchopulmonary dysplasia (BPD). Hyperpolarized (HP) gas diffusion magnetic resonance imaging (MRI) is a sensitive, safe, nonionizing, and noninvasive biomarker for measuring airspace size in vivo but has not yet been implemented in young infants. OBJECTIVE: This work quantified alveolar airspace size via HP gas diffusion MRI in healthy and diseased explanted infant lung specimens, with comparison to histological morphometry. METHODS: Lung specimens from 8 infants were obtained: 7 healthy left upper lobes (0-16 months, post-autopsy) and 1 left lung with filamin-A mutation, closely representing BPD lung disease (11 months, post-transplantation). Specimens were imaged using HP 3He diffusion MRI to generate apparent diffusion coefficients (ADCs) as biomarkers of alveolar airspace size, with comparison to mean linear intercept (Lm) via quantitative histology. RESULTS: Mean ADC and Lm were significantly increased throughout the diseased specimen (ADC = 0.26 ± 0.06 cm2/s, Lm = 587 ± 212 µm) compared with healthy specimens (ADC = 0.14 ± 0.03 cm2/s, Lm = 133 ± 37 µm; p < 1 × 10-7); increased values reflect enlarged airspaces. Mean ADCs in healthy specimens were significantly correlated to Lm (r = 0.69, p = 0.041). CONCLUSIONS: HP gas diffusion MRI is sensitive to healthy and diseased regional alveolar airspace size in infant lungs, with good comparison to quantitative histology in ex vivo specimens. This work demonstrates the translational potential of gas MRI techniques for in vivo assessment of normal and abnormal alveolar development in neonates with pulmonary disease.


Asunto(s)
Helio , Pulmón , Imagen de Difusión por Resonancia Magnética , Humanos , Lactante , Recién Nacido , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética
19.
Ann Am Thorac Soc ; 16(8): 1008-1016, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31038987

RESUMEN

Rationale: Lymphangioleiomyomatosis (LAM) is a rare disease associated with cystic destruction of the pulmonary parenchyma and chronic respiratory failure, and there are trials underway to determine if early intervention can prevent disease progression. An imaging technique that is sensitive to early regional disease would therefore be valuable for patient care and clinical trials.Objectives: We postulated that hyperpolarized 129Xe MRI would be sensitive to ventilation abnormalities and alveolar airspace dilation in patients with mild LAM disease and normal pulmonary function and that 129Xe MRI would reveal important features of cyst ventilation.Methods:129Xe ventilation and diffusion-weighted MR images were acquired in 22 patients with LAM during two breath-holds of hyperpolarized 129Xe. 129Xe ventilation defect percentage (VDP; percentage of voxels <60% of the mean whole-lung 129Xe MRI signal) and apparent diffusion coefficient (ADC), a measure of alveolar airspace size, were quantified and compared with pulmonary function test parameters with Spearman statistics. Sixteen patients with LAM had a recent, clinical chest computed tomography (CT) scan available, and cyst ventilation was assessed by thresholding cysts on the CT images and registration to the 129Xe ventilation images.Results: Ventilation deficits were observed in all patients with LAM, including those with normal pulmonary function and few cysts, and the mean VDP was 19.2% (95% confidence interval [CI], 14.8-23.5%). 129Xe VDP was strongly correlated with forced expiratory volume in 1 second (FEV1)/forced vital capacity (FVC) ratio (r = -0.51, P = 0.02) and diffusing capacity of the lung for carbon monoxide (DlCO) (r = -0.60, P = 0.009) but not with FEV1 (r = -0.33, P = 0.13), likely because of the sensitivity of 129Xe MRI to mild LAM disease in patients with normal FEV1. The mean ADC was 0.048 cm2/s (95% CI, 0.042-0.053 cm2/s). In many cases, ADC was elevated relative to previously reported values in adults, and ADC was correlated with FEV1, FEV1/FVC ratio, and DlCO (P ≤ 0.02 for all). Co-registered 129Xe MRI and CT imaging revealed considerable ventilation heterogeneity within individual patients with LAM and across patients with similarly sized cysts.Conclusions:129Xe MRI provides a means to assess the complex regional ventilation and alveolar airspace size changes of LAM with high sensitivity and may be a clinically useful future tool for screening, managing patients, and measuring treatment efficacy.


Asunto(s)
Linfangioleiomiomatosis/diagnóstico por imagen , Linfangioleiomiomatosis/fisiopatología , Imagen por Resonancia Magnética , Adulto , Dilatación , Femenino , Volumen Espiratorio Forzado , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Ventilación Pulmonar , Pruebas de Función Respiratoria , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Isótopos de Xenón
20.
J Cyst Fibros ; 16(2): 275-282, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27477942

RESUMEN

BACKGROUND: Cystic fibrosis (CF) is a genetic disease which carries high morbidity and mortality from lung-function decline. Monitoring disease progression and treatment response in young patients is desirable, but serial imaging via CT is often considered prohibitive, and detailed functional information cannot be obtained using conventional imaging techniques. Hyperpolarized 129Xe magnetic resonance imaging (MRI) can depict and quantify regional ventilation, but has not been investigated in pediatrics. We hypothesized that 129Xe MRI is feasible and would demonstrate ventilation defects in mild CF lung disease with greater sensitivity than FEV1. METHODS: 11 healthy controls (age 6-16years) and 11 patients with mild CF (age 8-16years, Forced Expiratory Volume (FEV1) percent predicted >70%) were recruited for this study. Nine CF patients had an FEV1>85%. Each subject was imaged via hyperpolarized 129Xe MRI, and the ventilation defect percentage (VDP) was measured. FEV1 and VDP were compared between the groups. RESULTS: FEV1 for controls was 100.3%±8.5% (mean±sd) and for CF patients was 97.9%±16.0% (p=0.67). VDP was 6.4%±2.8% for controls and 18.3%±8.6% for CF (p<0.001). When considering the 9 CF patients with normal FEV1 (>85%), the mean FEV1 was 103.1%±12.3% (p=0.57 compared to controls) and VDP was 15.4%±6.3% (p=0.002). CONCLUSIONS: Hyperpolarized 129Xe MRI demonstrated ventilation defects in CF patients with normal FEV1 and more effectively discriminated CF from controls than FEV1. Thus 129Xe may be a useful outcome measure to detect mild CF lung disease, to investigate regional lung function in pediatric lung diseases, and to follow disease progression.


Asunto(s)
Fibrosis Quística , Imagen por Resonancia Magnética/métodos , Isótopos de Xenón/farmacología , Adolescente , Niño , Fibrosis Quística/diagnóstico , Fibrosis Quística/fisiopatología , Progresión de la Enfermedad , Femenino , Volumen Espiratorio Forzado , Humanos , Masculino , Valor Predictivo de las Pruebas , Ventilación Pulmonar , Pruebas de Función Respiratoria/métodos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA