Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 128(18): 185002, 2022 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-35594117

RESUMEN

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr Heß spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. These advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

2.
Phys Rev Lett ; 121(9): 095002, 2018 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-30230893

RESUMEN

We report on the first multilocation electron temperature (T_{e}) and flow measurements in an ignition hohlraum at the National Ignition Facility using the novel technique of mid-Z spectroscopic tracer "dots." The measurements define a low resolution "map" of hohlraum plasma conditions and provide a basis for the first multilocation tests of particle and energy transport physics in a laser-driven x-ray cavity. The data set is consistent with classical heat flow near the capsule but reduced heat flow near the laser entrance hole. We evaluate the role of kinetic effects, self-generated magnetic fields, and instabilities in causing spatially dependent heat transport in the hohlraum.

3.
Phys Rev Lett ; 112(23): 233003, 2014 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-24972204

RESUMEN

High-resolution spectroscopy of the 2s(1/2)-2p(1/2) transition in the extreme ultraviolet region is shown to resolve the level splitting induced by the nuclear magnetic field of both the 2s(1/2) and the 2p(1/2) levels in lithiumlike (141)Pr(56+) and of the 2s(1/2)2p(1/2) (3)P(1) level in berylliumlike (141)Pr(55+). The (141)Pr ions are an ideal test of this measurement approach because their energy levels are known well from first principles and are unaffected by small energy contributions from QED and nuclear magnetization effects. The accuracy attained in the measured 196.5 ± 1.2 meV 2s(1/2) splitting is more than an order of magnitude better than that achieved before using crystal spectroscopy of the 2s(1/2)-2p(3/2) x-ray transition and at the level needed to implement a proposed scheme for disentangling the contributions from QED and nuclear magnetization effects in higher-Z ions, such as (209)Bi.

4.
Phys Rev Lett ; 111(11): 114803, 2013 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-24074095

RESUMEN

Thomson backscattering of intense laser pulses from relativistic electrons not only allows for the generation of bright x-ray pulses but also for the investigation of the complex particle dynamics at the interaction point. For this purpose a complete spectral characterization of a Thomson source powered by a compact linear electron accelerator is performed with unprecedented angular and energy resolution. A rigorous statistical analysis comparing experimental data to 3D simulations enables, e.g., the extraction of the angular distribution of electrons with 1.5% accuracy and, in total, provides predictive capability for the future high brightness hard x-ray source PHOENIX (photon electron collider for narrow bandwidth intense x rays) and potential gamma-ray sources.

5.
Phys Rev Lett ; 110(21): 213201, 2013 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-23745869

RESUMEN

The K shell excitation of H-like uranium (U(91+)) in relativistic collisions with different gaseous targets has been studied at the experimental storage ring at GSI Darmstadt. By performing measurements with different targets as well as with different collision energies, we were able to observe for the first time the effect of electron-impact excitation (EIE) process in the heaviest hydrogenlike ion. The large fine-structure splitting in H-like uranium allowed us to unambiguously resolve excitation into different L shell levels. State-of-the-art calculations performed within the relativistic framework which include excitation mechanisms due to both protons (nucleus) and electrons are in good agreement with the experimental findings. Moreover, our experimental data clearly demonstrate the importance of including the generalized Breit interaction in the treatment of the EIE process.

6.
J Dairy Sci ; 96(10): 6127-46, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23958008

RESUMEN

A typical casein micelle contains thousands of casein molecules, most of which form thermodynamically stable complexes with nanoclusters of amorphous calcium phosphate. Like many other unfolded proteins, caseins have an actual or potential tendency to assemble into toxic amyloid fibrils, particularly at the high concentrations found in milk. Fibrils do not form in milk because an alternative aggregation pathway is followed that results in formation of the casein micelle. As a result of forming micelles, nutritious milk can be secreted and stored without causing either pathological calcification or amyloidosis of the mother's mammary tissue. The ability to sequester nanoclusters of amorphous calcium phosphate in a stable complex is not unique to caseins. It has been demonstrated using a number of noncasein secreted phosphoproteins and may be of general physiological importance in preventing calcification of other biofluids and soft tissues. Thus, competent noncasein phosphoproteins have similar patterns of phosphorylation and the same type of flexible, unfolded conformation as caseins. The ability to suppress amyloid fibril formation by forming an alternative amorphous aggregate is also not unique to caseins and underlies the action of molecular chaperones such as the small heat-shock proteins. The open structure of the protein matrix of casein micelles is fragile and easily perturbed by changes in its environment. Perturbations can cause the polypeptide chains to segregate into regions of greater and lesser density. As a result, the reliable determination of the native structure of casein micelles continues to be extremely challenging. The biological functions of caseins, such as their chaperone activity, are determined by their composition and flexible conformation and by how the casein polypeptide chains interact with each other. These same properties determine how caseins behave in the manufacture of many dairy products and how they can be used as functional ingredients in other foods.


Asunto(s)
Caseínas/química , Caseínas/metabolismo , Micelas , Leche/química , Amiloide/química , Amiloide/metabolismo , Animales , Fosfatos de Calcio/metabolismo , Chaperoninas/química , Chaperoninas/metabolismo , Productos Lácteos , Interacciones Hidrofóbicas e Hidrofílicas , Conformación Proteica , Pliegue de Proteína
7.
Nat Commun ; 14(1): 7046, 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37949859

RESUMEN

Large laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal. These results nearly double the highest pressure at which extended x-ray absorption fine structure has been reported in any material. In this work, the copper temperature is unexpectedly found to be much higher than predicted when adjacent to diamond layer(s), demonstrating the important influence of the sample environment on the thermal state of materials; this effect may introduce additional temperature uncertainties in some previous experiments using diamond and provides new guidance for future experimental design.

8.
Phys Rev Lett ; 108(26): 264801, 2012 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-23004992

RESUMEN

We report on a study of the polarization transfer between transversely polarized incident electrons and the emitted x rays for electron-atom bremsstrahlung. By means of Compton polarimetry we performed for the first time an energy-differential measurement of the complete properties of bremsstrahlung emission related to linear polarization, i.e., the degree of linear polarization as well as the orientation of the polarization axis. For the high-energy end of the bremsstrahlung continuum the experimental results for both observables show a high sensitivity on the initial electron spin polarization and prove that the polarization orientation is virtually independent of the photon energy.

9.
Phys Rev Lett ; 109(6): 064802, 2012 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-23006273

RESUMEN

X-ray spectroscopy is used to obtain single-shot information on electron beam emittance in a low-energy-spread 0.5 GeV-class laser-plasma accelerator. Measurements of betatron radiation from 2 to 20 keV used a CCD and single-photon counting techniques. By matching x-ray spectra to betatron radiation models, the electron bunch radius inside the plasma is estimated to be ~0.1 µm. Combining this with simultaneous electron spectra, normalized transverse emittance is estimated to be as low as 0.1 mm mrad, consistent with three-dimensional particle-in-cell simulations. Correlations of the bunch radius with electron beam parameters are presented.

10.
Occup Med (Lond) ; 61(6): 440-2, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21824996

RESUMEN

BACKGROUND: Occupational diisocyanate-induced extrinsic allergic alveolitis (EAA) is a rare and probably underestimated diagnosis. Two acute occupational EAA cases have been described in this context, but neither of them concerned hexamethylene diisocyanate (HDI) exposure. AIMS: To investigate the cause of a life-threatening EAA arising at work in a healthy 30-year-old female paint quality controller. METHODS: Occupational medical assessment, workplace evaluation, airborne and biological monitoring and immunodermatological tests. RESULTS: Diagnosis of EAA relied on congruent clinical and radiological information, confirmed occupational HDI exposure and positive IgG antibodies and patch tests. The patient worked in a small laboratory for 7 years, only occasionally using HDI-containing hardeners. While working with HDI for 6 h, she developed breathlessness, rapidly progressing to severe respiratory failure. Workplace HDI airborne exposure values ranged from undetectable levels to 4.25 p.p.b. Biological monitoring of urinary hexamethylene diamine in co-workers ranged from <1.0 to 15.4 µg/g creatinine. Patch tests 8 months later showed delayed skin reaction to HDI at 48 h. Subsequent skin biopsy showed spongiotic dermatitis with infiltration of CD4(+) and CD8(+) T cells. CONCLUSIONS: We believe this is the first reported case of acute life-threatening EAA following exposure to HDI. Low concentrations of airborne HDI and relatively high urinary hexamethylene diamine suggest significant skin absorption of HDI could have significantly contributed to the development of this acute occupational EAA.


Asunto(s)
Contaminantes Ocupacionales del Aire/toxicidad , Alveolitis Alérgica Extrínseca/inducido químicamente , Cianatos/toxicidad , Enfermedades Profesionales/inducido químicamente , Exposición Profesional/efectos adversos , Pintura/toxicidad , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Isocianatos
11.
Rev Sci Instrum ; 92(5): 053102, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243250

RESUMEN

We report the development of a high-resolution spectrometer for extended x-ray absorption fine structure (EXAFS) studies of materials under extreme conditions. A curved crystal and detector in the spectrometer are replaceable such that a single body is employed to perform EXAFS measurements at different x-ray energy intervals of interest. Two configurations have been implemented using toroidal crystals with Ge 311 reflection set to provide EXAFS at the Cu K-edge (energy range 8.9-9.8 keV) and Ge 400 reflection set to provide EXAFS at the Ta L3-edge (9.8-10.7 keV). Key performance characteristics of the spectrometer were found to be consistent with design parameters. The data generated at the National Ignition Facility have shown an ≃3 eV spectral resolution for the Cu K-edge configuration and ≃6 eV for the Ta L3-edge configuration.

12.
Rev Sci Instrum ; 92(4): 043531, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243385

RESUMEN

This paper describes a new class of focusing crystal forms for the x-ray Bragg crystal spectroscopy of small, point-like, x-ray sources. These new crystal forms are designed with the aid of sinusoidal spirals, a family of curves, whose shapes are defined by only one parameter, which can assume any real value. The potential of the sinusoidal spirals for the design x-ray crystal spectrometers is demonstrated with the design of a toroidally bent crystal of varying major and minor radii for measurements of the extended x-ray absorption fine structure near the Ta-L3 absorption edge at the National Ignition Facility.

13.
Science ; 256(5058): 822-5, 1992 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-17756446

RESUMEN

C(60) and liquid bromine react to form C(60)Br(24), a crystalline compound isolated as a bromine solvate, C(60)Br(24)(Br(2))(x), The x-ray crystal structure defines a new pattern of addition to the carbon skeleton that imparts a rare high symmetry. The parent C(60) framework is recognizable in C(60)Br(24), but sp(3) carbons at sites of bromination distort the surface, affecting conformations of all of the hexagonal and pentagonal rings. Twenty-four bromine atoms envelop the carbon core, shielding the 18 remaining double bonds from addition. At 150 degrees to 200 degrees C there is effectively quantitative reversion of C(60)Br(24) to C(60) and Br(2).

14.
Rev Sci Instrum ; 90(12): 125113, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31893795

RESUMEN

The use of x-ray diffraction (XRD) measurements in laser-driven dynamic compression experiments at high-power laser facilities is becoming increasingly common. Diffraction allows one to probe in situ the transformations occurring at the atomic level at extreme conditions of pressure, temperature, and time scale. In these measurements, the x-ray source is generated by irradiation of a solid foil. Under certain laser drive conditions, quasimonochromatic He-α radiation is generated. Careful analysis of the x-ray source plasma spectra reveals that this radiation is not a single line emission and that monochromaticity is highly dependent on the laser irradiance. In this work, we analyze how the spectra emitted by laser-irradiated copper, germanium, and iron foils at the Omega Laser vary depending on different laser drive conditions and discuss the implications for XRD experiments.

15.
Rev Sci Instrum ; 90(1): 013506, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30709229

RESUMEN

The sensitivity of Fuji SR and MS image plates (IPs) used in x-ray spectrometers on OMEGA and the National Ignition Facility has been measured using two techniques. A set of radioisotopes has been used to constrain image-plate sensitivity between 6 and 60 keV, while a Manson source has been used to expose image plates to x rays at energies between 1.5 and 8 keV. These data have shown variation in sensitivity on the order of 5% for a given IP type and scanner settings. The radioisotope technique has also been used to assess IP fading properties for MS-type plates over long times. IP sensitivity as a function of scanner settings and pixel size has been systematically examined, showing variations of up to a factor of 2 depending on the IP type. Cross-calibration of IP scanners at different facilities is necessary to produce a consistent absolute sensitivity curve spanning the energy range of 2-60 keV.

16.
Eur Respir J ; 32(4): 962-9, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18579551

RESUMEN

Chronic obstructive pulmonary disease (COPD) is associated with important chronic comorbid diseases, including cardiovascular disease, diabetes and hypertension. The present study analysed data from 20,296 subjects aged > or =45 yrs at baseline in the Atherosclerosis Risk in Communities Study (ARIC) and the Cardiovascular Health Study (CHS). The sample was stratified based on baseline lung function data, according to modified Global Initiative for Obstructive Lung Disease (GOLD) criteria. Comorbid disease at baseline and death and hospitalisations over a 5-yr follow-up were then searched for. Lung function impairment was found to be associated with more comorbid disease. In logistic regression models adjusting for age, sex, race, smoking, body mass index and education, subjects with GOLD stage 3 or 4 COPD had a higher prevalence of diabetes (odds ratio (OR) 1.5, 95% confidence interval (CI) 1.1-1.9), hypertension (OR 1.6, 95% CI 1.3-1.9) and cardiovascular disease (OR 2.4, 95% CI 1.9-3.0). Comorbid disease was associated with a higher risk of hospitalisation and mortality that was worse in people with impaired lung function. Lung function impairment is associated with a higher risk of comorbid disease, which contributes to a higher risk of adverse outcomes of mortality and hospitalisations.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Diabetes Mellitus/terapia , Hipertensión/terapia , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Enfermedad Pulmonar Obstructiva Crónica/terapia , Enfermedades Cardiovasculares/epidemiología , Estudios de Cohortes , Complicaciones de la Diabetes/terapia , Diabetes Mellitus/epidemiología , Femenino , Hospitalización , Humanos , Hipertensión/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Riesgo , Resultado del Tratamiento
17.
Phys Rev E Stat Nonlin Soft Matter Phys ; 77(6 Pt 2): 066406, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18643382

RESUMEN

Measurements of the L -shell emission of highly charged gold ions were made under controlled laboratory conditions using the SuperEBIT electron beam ion trap, allowing detailed spectral observations of lines from Fe-like Au53+ through Ne-like Au69+ . Using atomic data from the Flexible Atomic Code, we have identified strong 3d_{52}-->2p_{32} emission features that can be used to diagnose the charge state distribution in high energy density plasmas, such as those found in the laser entrance hole of hot hohlraum radiation sources. We provide collisional-radiative calculations of the average ion charge Z as a function of temperature and density, which can be used to relate charge state distributions inferred from 3d_{52}-->2p_{32} emission features to plasma conditions, and investigate the effects of plasma density on calculated L -shell Au emission spectra.

18.
Rev Sci Instrum ; 89(10): 10F119, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399669

RESUMEN

At large laser faculties, such as OMEGA and the National Ignition Facility (NIF), x-ray spectrometers are provided by the facility to diagnose plasma conditions or monitor backlighters. Often the calibration of these spectrometers is unknown or out of date. As a remedy to this situation, we present a simple ray trace method to calibrate flat crystal spectrometers using only basic information regarding the optical design of the spectrometer. This model is then used to output photometric throughput estimates, dispersion, solid angle, and spectral resolution estimates. This model is applied to the mono angle crystal spectrometer and Super Snout I at the NIF and the X-Ray Spectrometer at the OMEGA laser facility.

19.
Rev Sci Instrum ; 89(10): 10G108, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399872

RESUMEN

In the quest for reaching ignition of deuterium-tritium (DT) fuel capsule implosions, experiments on the National Ignition Facility (NIF) have shown lower final fuel areal densities than simulated. Possible explanations for reduced compression are higher preheat that can increase the ablator-DT ice density jump and induce mix at that interface or reverberating shocks. We are hence developing x-ray Refraction Enhanced Radiography (RER) to infer the inflight density profiles in layered fuel capsule implosions. We use a 5 µm slit backlit by a Ni 7.8 keV He-α NIF laser driven x-ray source positioned at 20 mm from the capsule to cast refracted images of the inflight capsule onto a streak camera in a high magnification (M ∼ 60×) setup. Our first experiments have validated our setup that recorded a streaked x-ray fringe pattern from an undriven high density carbon (HDC) capsule consistent with ray tracing calculations at the required ∼6 µm and 25 ps resolution. Streaked RER was then applied to inflight layered HDC capsule implosions using a hydrogen-tritium fuel mix rather than DT to reduce neutron yields and associated backgrounds. The first RER of an imploding capsule revealed strong features associated with the ablation front and ice-ablator interface that are not visible in standard absorption radiographs.

20.
Rev Sci Instrum ; 89(10): 10F123, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399981

RESUMEN

At the National Ignition Facility (NIF), storage phosphor image plates (IP) are used extensively for recording x-rays, charged particles, and neutrons. For x-ray imaging and spectroscopy, absolute and relative calibrations are important for extracting plasma information from the diagnostics. We use Fuji MS, SR, and TR image plates that have been cut to fit custom diagnostic envelopes. The image plates are scanned on a General Electric FLA 7000 IP flying spot scanner. Calibrations for sensitivity, spatial scale, and temperature dependent fade are applied. During a set of recent calibrations, we noticed large shifts in the absolute calibration of the image plate system. The possible source of these shifts is discussed. We discuss scanner stability and a method for calibration. We discuss the fade and temperature effects of the image plates and how this correction is applied within the NIF environment. We also compare our NIF GE FLA 7000 IP scanner with a new General Electric Amersham Typhoon IP scanner.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA