Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Stroke ; 55(2): 432-442, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38252754

RESUMEN

BACKGROUND: While most European Regions perform well in global comparisons, large discrepancies within stroke epidemiological parameters exist across Europe. The objective of this analysis was to evaluate the stroke burden across European regions and countries in 2019 and its difference to 2010. METHODS: The GBD 2019 analytical tools were used to evaluate regional and country-specific estimates of incidence, prevalence, deaths, and disability-adjusted life years of stroke for the European Region as defined by the World Health Organization, with its 53 member countries (EU-53) and for European Union as defined in 2019, with its 28 member countries (EU-28), between 2010 and 2019. Results were analyzed at a regional, subregional, and country level. RESULTS: In EU-53, the absolute number of incident and prevalent strokes increased by 2% (uncertainty interval [UI], 0%-4%), from 1 767 280 to 1 802 559 new cases, and by 4% (UI, 3%-5%) between 2010 and 2019, respectively. In EU-28, the absolute number of prevalent strokes and stroke-related deaths increased by 4% (UI, 2%-5%) and by 6% (UI, 1%-10%), respectively. All-stroke age-standardized mortality rates, however, decreased by 18% (UI, -22% to -14%), from 82 to 67 per 100 000 people in the EU-53, and by 15% (UI, -18% to -11%), from 49.3 to 42.0 per 100 000 people in EU-28. Despite most countries presenting reductions in age-adjusted incidence, prevalence, mortality, and disability-adjusted life year rates, these rates remained 1.4×, 1.2×, 1.6×, and 1.7× higher in EU-53 in comparison to the EU-28. CONCLUSIONS: EU-53 showed a 2% increase in incident strokes, while they remained stable in EU-28. Age-standardized rates were consistently lower for all-stroke burden parameters in EU-28 in comparison to EU-53, and huge discrepancies in incidence, prevalence, mortality, and disability-adjusted life-year rates were observed between individual countries.


Asunto(s)
Carga Global de Enfermedades , Accidente Cerebrovascular , Humanos , Europa (Continente)/epidemiología , Accidente Cerebrovascular/epidemiología , Incertidumbre , Organización Mundial de la Salud
2.
Ann Surg ; 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38501239

RESUMEN

OBJECTIVE: This study aimed to present the early and mid-term outcomes of fenestrated/branched thoracic endovascular aortic repair (f/bTEVAR) for aortic arch pathologies. BACKGROUND: f/bTEVAR represents a less invasive treatment option for aortic arch diseases. Previous published series showed decreased early mortality and morbidity compared to open repair. METHODS: A single-center retrospective analysis of consecutive patients, managed with f/bTEVAR (Cook Medical, Bloomington, IN, USA) between 01.09.11and 30.06.22 was conducted. Primary outcomes were technical success, 30-day mortality and stroke. Data during follow-up and factors affecting early mortality and stroke were analyzed. RESULTS: 209 patients were included (38.3% females; mean age 69.8±3.4years; mean aortic diameter 61±4.7 mm); 14.4% were managed urgently. Fenestrations/scallop configuration was used in 39.7%, branched devices in 55.5% and branch/scallop combination in 4.8%. Landing to zone 0 was performed in 65.5% and in zone 1 in 32.1%. Non-native aortas were used for landing in 39.2%. Technical success was 97.1% and 30-day mortality 9.5%. Strokes were identified in 10%; 5.7% major. Non-native proximal aortic landing zone was an independent protective factor for stroke (P=0.002). Post-operative stroke (P<0.001) and pericardial effusion (P<0.001) were independently related to 30-day mortality. The mean follow-up was 21±8 months. The estimated survival and freedom from reintervention rates were 79.5% (standard error; SE3.1%) and 47.1% (SE 4.3%) at 24months, respectively. CONCLUSIONS: f/bTEVAR presented high technical success and acceptable 30-day mortality. Non-native proximal landing zone was related to lower stroke rate. Half of patients needed a reintervention within the 24-month follow-up.

3.
Ann Surg ; 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38323417

RESUMEN

OBJECTIVE: To analyze the outcomes of urgent/emergent endovascular aortic repair of patients with free/contained ruptured thoracoabdominal aortic aneurysms (rTAAA). BACKGROUND: Endovascular repair of rTAAA has been scarcely described in emergent setting. METHODS: An international multicenter retrospective observational study (ClinicalTrials.govID:NCT05956873) from January-2015 to January-2023 in 6 European and 1 United States Vascular Surgery Centers. Primary end-points were technical success, 30-day and/or in-hospital mortality and follow-up survival. RESULTS: A total of 100 rTAAA patients were included (75 male; mean age 73 y). All patients (86 contained and 14 free ruptures) were symptomatic and treated within 24-hours from diagnosis: multi-branched off-the-shelf devices (Zenith t-branch,Cook Medical Inc.Bjaeverskov,Denmark) in 88 patients, physician-modified endografts in 8, patient-specific device or parallel grafts in two patients each. Primary technical success was achieved in 89 patients and 30-day and/or in-hospital mortality was 24%. Major adverse events (MAEs) occurred in 34% of patients (permanent dialysis and paraplegia in 4 and 8 patients, respectively). No statistical differences were detected in mortality rates between free and contained ruptured patients (43%vs.21%; P =0.075). Multivariate analysis revealed contained rupture favoring technical success (Odd-Ratio10.1;95%Confidence-Interval:3.0-33.6; P =<0.001). MAEs (OR9.4;95%C-I:2.8-30.5; P =<0.001) and pulmonary complications (OR11.3;95%CI:3.0-41.5; P =<0.001) were independent risk factors for 30-day and/or in-hospital mortality. Median follow-up time was 13 months (interquartile range 5-24); 1-year survival rate was 65%. Aneurysm diameter>80 mm (Hazard-Ratio:2.0;95%CI:1.0-30.5; P =0.037), technical failure (HR:2.6;95%CI:1.1-6.5; P =0.045) and pulmonary complications (HR:3.0;95%CI:1.2-7.9; P =0.021) were independent risk factors for follow-up mortality. CONCLUSION: Endovascular repair of rTAAA shows high technical success; the presence of free rupture alone appear not to correlate with early mortality. Effective prevention/management of post-operative complications is crucial for survival.

4.
Ann Surg ; 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38647145

RESUMEN

OBJECTIVE: With an increasing life expectancy, more octogenarian patients are referred with complex aortic aneurysms (cAAA). The aim of this study was to evaluate short and mid-term outcomes following fenestrated aortic repair (FEVAR) in octogenarians. SUMMARY BACKGROUND DATA: Few studies looking at octogenarian-specific outcomes with diverging results. METHODS: Retrospective, multicentre cohort study including consecutive patients undergoing elective FEVAR for cAAAs or type IV thoracoabdominal aortic aneurysms between 2007-2022 in eight high-volume centres. Octogenarians vs. non-octogenarians were compared. The primary outcome was 30-day mortality. Secondary outcomes included 1, 2 and 5-year survival and reintervention rates. RESULTS: A total of 729 patients (median age of 74.8 years [IQR 69.2 - 79.14]) were included, 169 (23%) of which were octogenarians, with 316 (43.3%) patients undergoing juxta/pararenal aneurysm repair. Although octogenarians presented less complex but larger (61 mm vs. 58 mm) aneurysms, the number of fenestrations was similar across groups. No differences in in-hospital mortality (4.1 vs. 3.0%), MAE (16.6% vs 12.2%) or reintervention rates (11.2 vs. 10%) were found. Multivariable logistic regression of in-hospital mortality identified BMI (OR 0.66, 95% CI 0.51-0.95, P=0.003), chronic heart failure (OR 7.70, 95% CI 1.36-36.15, P=0.003) and GFR<45 ml/min/1.73 m2 (OR 5.25, 95% CI 1.20-22.86, P=0.027) as independent predictors. Median follow-up was 41 months. The 1, 2 and 5-year survival rates were 91.3%, 81.8% and 49.5% in octogenarians vs 90.6%, 86.5% and 68.8% in non-octogenarian patients (Log-rank: =0.001). Freedom from aortic-related death and freedom from reintervention at five-years were similar across groups (log-rank=0.94 and .76, respectively). Age>80 was not an independent predictor of 30-day or long-term mortality on multivariable and Cox regression analysis. CONCLUSIONS: Elective FEVAR in octogenarians appears to be safe, with similar outcomes as in younger patients. Future studies looking at improved patient selection methods to ensure long-term survival benefits in both octogenarians and younger patients are warranted.

5.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38453660

RESUMEN

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Isquemia de la Médula Espinal , Masculino , Humanos , Anciano , Femenino , Reparación Endovascular de Aneurismas , Prótesis Vascular , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Isquemia de la Médula Espinal/etiología , Paraplejía/etiología
6.
J Endovasc Ther ; : 15266028241245345, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654600

RESUMEN

PURPOSE: To present a novel technique that enables safe and effective cannulation of target vessels with challenging anatomy during fenestrated/branched endovascular aortic repair (F/B-EVAR). TECHNIQUE: Following deployment of the F/B-EVAR endograft, the target vessels (TVs) are cannulated. The bundle wire technique provides a solution to challenging TVs and uses multiple fine atraumatic guidewires that together serve as a stiff guidewire. The technique can be executed in 2 ways using: (1) one 0.018 inch and one 0.014 inch guidewire or (2) three 0.014 inch guidewires. We demonstrate the technique in a case of a complex abdominal aortic aneurysm treated using branched EVAR in which the left renal artery with severe ostial stenosis was catheterized using the bundle wire technique. CONCLUSIONS: The bundle wire technique offers a technically feasible and economically viable solution for facilitating catheter and bridging stent delivery in anatomically challenging TVs during F/B-EVAR. It is a useful addition to the therapeutic armamentarium available to physicians for accessing demanding TVs.

7.
J Endovasc Ther ; : 15266028241231882, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38400539

RESUMEN

OBJECTIVE: Fenestrated endovascular aneurysm repair (FEVAR) has become one of the standard treatment options for complex abdominal aortic aneurysms (cAAAs) and thoraco-abdominal aortic aneurysms (TAAAs). Despite technological advances in the main endograft design, the lack of dedicated bridging stent-grafts (BSGs) is still the Achilles heel of the procedure. The aim of this study was to evaluate the mid-term outcomes of the BeGraft stent-graft as a dedicated bridging stent for FEVAR and to review the current evidence in literature. METHODS: Retrospective single center study, including all consecutive FEVARs performed between September 2018 and December 2022 for the treatment of cAAAs and TAAAs with implantation of at least one BeGraft peripheral as the main BSG in one of the target vessels (TVs). Primary endpoints were technical success and TV instability of TV bridged with a BeGraft stent, as well as 30-day mortality and re-intervention rates. Secondary endpoints were follow-up TV instability, re-interventions, and mortality. RESULTS: A total of 113 patients (93 male, mean age 71.1±9.7) and 440 TV (14 scallops and 426 fenestrations) were included. Of the 440 TV, 406 received primary stenting. Be Grafts were used in 88.9% of these (n=361; celiac trunk [CT]=67, superior mesenteric artery [SMA]=98, right renal artery [RRA]=97, and left renal artery [LRA]=99). The technical success rate was 99.4% (359/361). The 30-day TV instability rate was 0.27% (1/361) with one early renal artery occlusion. During a median follow-up of 20 months (6-32), TV instability rate was 0.8% (3/361). Freedom from TV instability was 99.3%, 98.8%, and 98.8% at 1, 2, and 3 years, respectively. CONCLUSION: Early-term and mid-term results regarding TV instability are satisfactory and support the use of BeGraft as BSG in FEVAR for cAAAs and TAAAs. CLINICAL IMPACT: The findings of the current study show that the use of the BeGraft stent graft as bridging stent in FEVAR is associated with a high technical success and low early and mid-term instability rate and support the standard use as a bridging stent in fenestrated aneurysm repair.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38685310

RESUMEN

OBJECTIVE: This study aimed to evaluate the impact of target vessel anatomy and bridging stent geometry on target vessel instability in branched endovascular aortic repair (B-EVAR). METHODS: This retrospective, single centre cohort study included all consecutive B-EVARs performed between September 2018 and December 2022 for thoraco-abdominal aortic aneurysm (TAAA) or complex abdominal aortic aneurysm (CAAA). The primary endpoints were target vessel instability and related re-interventions at 12 months. Secondary endpoints were 30 day results, including target vessel instability and re-interventions. Target vessel instability analysis consisted of assessment of target vessel anatomy, including diameter, aortic trunk to branch angle, and tortuosity. Post-operative parameters included change of clock position/horizontal misalignment, bridging length (gap), sealing length, tortuosity, post-stenting angle, and oversizing ratio. RESULTS: A total of 69 patients (TAAA: n = 56, 81%; CAAA: n = 13, 19%) and 271 (133 visceral and 138 renal) target vessels were included. The cumulative incidence of target vessel instability was 4.8%, 6.4%, and 7.9% at one, two, and three years, respectively. In the renal target vessel group, vessel diameter ≤ 4 mm (hazard ratio [HR] 1.28, 95% confidence interval [CI] 1.116 - 2.54; p = .022) and a bridging length ≥ 25 mm (HR 1.320, 95% CI 1.066 - 1.636; p = .011) were associated with increased target vessel instability. In visceral vessels, a change in clock position/horizontal misalignment ≥ 70 minutes (HR 1.072, 95% CI 1.026 - 1.121; p = .002) showed a significant association with target vessel instability. CONCLUSION: Target vessel diameter, bridging length (gap), and horizontal misalignment seemed to be associated with adverse target vessel outcomes. This may be solved with more customised endograft solutions to reduce the negative impact of the latter parameter.

9.
Eur J Vasc Endovasc Surg ; 67(1): 106-116, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37536517

RESUMEN

OBJECTIVE: Fenestrated and branched thoracic endovascular aortic repair (F/B-TEVAR) of the aortic arch is a viable approach in patients unsuitable for open repair. The aim was to summarise the published results of manufactured F/B-TEVAR devices for partial and total repair of the aortic arch, and to compare fenestrated with branched configurations. DATA SOURCES: PubMed, Scopus and The Cochrane Library were searched for articles (2018 - 2021) about patients with elective, urgent, or emergency aortic requiring a proximal landing zone in the aortic arch (zone 0 - 1 - 2) and treated by F/B-TEVAR. REVIEW METHODS: The systematic review and meta-analysis were performed according to the PRISMA guidelines. Open repair, supra-aortic trunk (SAT) debranching + standard TEVAR, and in situ physician modified and parallel grafts were excluded. Primary outcomes were technical success and 30 day mortality rate. Secondary outcomes were 30 day major adverse events, and overall survival and procedure related endpoints during follow up. RESULTS: Of 458 articles screened, 18 articles involving 571 patients were selected. Indications for intervention were chronic dissections (50.1%), degenerative aneurysms (39.6%), penetrating aortic ulcers (7.4%), and pseudoaneurysms (2%). F-TEVAR, B-TEVAR, and F+B-TEVAR were used in 38.4%, 54.1%, and 7.5% of patients, respectively. Overall, technical success was 95.9% (95% confidence interval [CI] 0.93 - 0.97; I2 = 0%; p for heterogeneity (Het) = .77) and the 30 day mortality rate was 6.7% (95% CI 0.05 - 0.09; I2 = 0%; p Het = .66). No statistical differences were found comparing fenestrated with branched endografts, except for a higher rate of type I - III endoleaks in F-TEVAR (9.8% vs. 2.6%; p = .034). The overall survival rate and freedom from aortic related death at the one year follow up ranged between 82 - 96.4% and 94 - 94.7%, respectively. Thirteen and five studies were considered at moderate and high risk of bias, respectively. CONCLUSION: F/B-TEVAR for the treatment of the aortic arch, according to experience in dedicated centres, now enjoys a satisfactory level of technical success together with a progressively reduced early mortality rate. There are several limitations, and further studies are needed to reach clearer conclusions.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Resultado del Tratamiento , Factores de Riesgo , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Estudios Retrospectivos
10.
Artículo en Inglés | MEDLINE | ID: mdl-38879148

RESUMEN

OBJECTIVE: To evaluate sex based differences in ascending aorta and arch anatomy in patients with underlying proximal aortic disease and to evaluate their impact on feasibility for total endovascular repair with custom made, arch branched devices. METHODS: This was a retrospective cross-sectional review of all patients undergoing open and or total endovascular arch repair due to distal ascending aorta and or aortic arch pathologies in a single high volume aortic centre between 2012 and 2022. Anatomical ascending aorta and aortic arch parameters were analysed on a centreline of flow on a dedicated 3D workstation. Sex related differences of the ascending aorta, aortic arch, and supra-aortic vessels were evaluated. Subsequently, four endovascular devices were assessed for feasibility: double and triple branched devices both for the Zenith (Cook Medical) and Relay (Terumo Aortic) platforms, first in accordance with the instructions for use and then considering the possibility of adjunctive cervical debranching. The primary endpoints were sex specific differences in aortic anatomy, while secondary endpoints included sex based feasibility of branched endograft devices. RESULTS: During the study period, 395 patients underwent total aortic arch repair, of whom 152 (51 female, 33.5%) had high quality available computed tomography angiographies and were included in the study. Female patients had a shorter proximal landing zone than male patients (22 mm vs. 47 mm; p < .001). Left subclavian artery dissection was more frequent in men (24.8% vs. 3.9%; p < .001). Other anatomical parameters showed a similar distribution between sexes. Female patients presented a lower feasibility for double branched devices (35.3% vs. 58.4%; p = .015) as well as a tendency for lower feasibility rates for triple branched devices (31.4% vs. 47.5%; p = .081). CONCLUSION: Although most ascending aortic and arch parameters showed similar trends in both sexes, the availability of a suitable proximal landing zone was lower in female patients. Consequently, female patients had lower feasibility rates for double arch branched endografts and, to lesser extent, for triple arch branched endografts.

11.
Eur J Vasc Endovasc Surg ; 67(1): 132-145, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37777049

RESUMEN

OBJECTIVE: To evaluate the contemporary growth rate of small abdominal aortic aneurysms (AAAs) in view of recent epidemiological changes, such as decreasing smoking rates and establishment of population screening programmes. DATA SOURCES: MEDLINE, CENTRAL, PsycINFO, Web of Science Core Collection, and OpenGrey databases. REVIEW METHODS: Systematic review following the PRISMA guidelines. In October 2021, databases were queried for studies reporting on AAA growth rates published from 2015 onwards. The primary outcome was contemporary AAA growth rates in mm/year. Data were pooled in a random effects model meta-analysis, and heterogeneity was assessed through the I2 statistic. GRADE assessment of the findings was performed. The protocol was published in PROSPERO (CRD42022297404). RESULTS: Of 8 717 titles identified, 43 studies and 28 277 patients were included: 1 241 patients from randomised controlled trials (RCTs), 23 941 from clinical observational studies, and 3 095 from radiological or translational research studies. The mean AAA growth rate was 2.38 mm/year (95% CI 2.16 - 2.60 mm/year; GRADE = low), with meta-regression analysis adjusted for baseline diameter showing an increase of 0.08 mm/year (95% CI 0.024 - 0.137 mm/year; p = .005) for each millimetre of increased baseline diameter. When analysed by study type, the growth rate estimated from RCTs was 1.88 mm/year (95% CI 1.69 - 2.06 mm/year; GRADE = high), while it was 2.31 mm/year (95% CI 1.95 - 2.67 mm/year; GRADE = moderate) from clinical observational studies, and 2.85 mm/year (95% CI 2.44 - 3.26 mm/year; GRADE = low) from translational and radiology based studies (p < .001). Heterogeneity was high, and small study publication bias was present (p = .003), with 27 studies presenting a moderate to high risk of bias. The estimated growth rate from low risk studies was 2.09 mm/year (95% CI 1.87 - 2.32; GRADE = high). CONCLUSION: This study estimated a contemporaneous AAA growth rate of 2.38 mm/year, being unable to demonstrate any clinically meaningful AAA growth rate reduction concomitant with changed AAA epidemiology. This suggests that the RESCAN recommendations on small AAA surveillance are still valid. However, sub-analysis results from RCTs and high quality study data indicate potential lower AAA growth rates of 1.88 - 2.09 mm/year, findings that should be validated in a high quality prospective registry.

12.
Artículo en Inglés | MEDLINE | ID: mdl-38705454

RESUMEN

OBJECTIVE: This study aimed to report the initial experience with a novel bidirectional double cuff inner branch design for incorporation of renal and mesenteric arteries in patients undergoing fenestrated and branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective review was undertaken of the experience of F/BEVAR with grafts integrating at least one bidirectional double cuffed inner branch implanted at three tertiary aortic centres between March 2022 and June 2023. All consecutive patients were included. Baseline characteristics, operative data, and follow up data were collected. Results were presented as number or median (interquartile range) unless otherwise stated. RESULTS: Thirteen patients (10 male; median age 72 [68, 77] years) had F/BEVAR using a total of 15 bidirectional double cuffed inner branches (30 cuffs). Indications for bidirectional doubled cuffed inner branches included cranial vessel orientation or double renal arteries in four patients each, common coeliomesenteric trunk in three patients, and early renal artery bifurcation, renal artery origin from a false lumen requiring a flexible route for catheterisation, and surplus configuration in one patient each. Twenty three of the 30 cuffs were used, whereas the remaining seven cuffs were intentionally occluded with vascular plugs. Target vessel incorporation was successful in all bidirectional branches. There was one technical failure related to unsuccessful catheterisation of a left renal artery targeted through a unidirectional caudal inner branch. During a median follow up of seven months there were no instances of target vessel instability or re-interventions and two patients died of causes unrelated to the bidirectional branches. CONCLUSION: The results of the use of bidirectional double cuff inner branches are promising, with high technical success and no short term branch related complications in this preliminary experience. This could potentially expand the applicability of branch endografting of complex endovascular aortic repairs, but long term results are still missing.

13.
Eur J Vasc Endovasc Surg ; 67(2): 192-331, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38307694

RESUMEN

OBJECTIVE: The European Society for Vascular Surgery (ESVS) has developed clinical practice guidelines for the care of patients with aneurysms of the abdominal aorta and iliac arteries in succession to the 2011 and 2019 versions, with the aim of assisting physicians and patients in selecting the best management strategy. METHODS: The guideline is based on scientific evidence completed with expert opinion on the matter. By summarising and evaluating the best available evidence, recommendations for the evaluation and treatment of patients have been formulated. The recommendations are graded according to a modified European Society of Cardiology grading system, where the strength (class) of each recommendation is graded from I to III and the letters A to C mark the level of evidence. RESULTS: A total of 160 recommendations have been issued on the following topics: Service standards, including surgical volume and training; Epidemiology, diagnosis, and screening; Management of patients with small abdominal aortic aneurysm (AAA), including surveillance, cardiovascular risk reduction, and indication for repair; Elective AAA repair, including operative risk assessment, open and endovascular repair, and early complications; Ruptured and symptomatic AAA, including peri-operative management, such as permissive hypotension and use of aortic occlusion balloon, open and endovascular repair, and early complications, such as abdominal compartment syndrome and colonic ischaemia; Long term outcome and follow up after AAA repair, including graft infection, endoleaks and follow up routines; Management of complex AAA, including open and endovascular repair; Management of iliac artery aneurysm, including indication for repair and open and endovascular repair; and Miscellaneous aortic problems, including mycotic, inflammatory, and saccular aortic aneurysm. In addition, Shared decision making is being addressed, with supporting information for patients, and Unresolved issues are discussed. CONCLUSION: The ESVS Clinical Practice Guidelines provide the most comprehensive, up to date, and unbiased advice to clinicians and patients on the management of abdominal aorto-iliac artery aneurysms.

14.
Vascular ; : 17085381241257736, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38807487

RESUMEN

PURPOSE: To report the first chronic limb-threatening ischemia (CLTI) patients who underwent an intravascular lithotripsy (IVL)-assisted percutaneous deep vein arterialization (pDVA). CASE REPORT 1: An 81-year-old patient presented with CLTI and a heavily calcified lesion of the popliteal artery and tibioperoneal trunk (TPT), with a distal tibial and foot arch occlusion. The patient underwent IVL and drug-coated balloon angioplasty for the distal popliteal artery and of the TPT to improve the inflow prior to pDVA. The wound situation remained stable without secondary procedure until the patient`s deaths due to complications of urosepsis 3 months later. CASE REPORT 2: A 64-year-old patient with rest pain of the left limb with a single-vessel tibial run-off (peroneal artery) and occluded pedal arch was treated with 3.5 mm IVL followed by a successful pDVA as mentioned above. IVL performed in the proximal posterior tibial artery to optimize the inflow to the circuit and change the compliance of the crossing point from the arterial to the vein system. The patient underwent repeat angioplasty of the plantar vein arch 5 months after the index procedure and thereafter remained asymptomatic during 2 years of follow-up. CONCLUSION: The combined use of IVL and pDVA could improve the patency of the reconstruction with clinical benefits in no-option CTLI patients.

15.
Ann Surg ; 278(2): e389-e395, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35837956

RESUMEN

OBJECTIVE: To report the mid-term outcomes of fenestrated-branched endovascular aneurysm repair (F-BEVAR) following a failed previous endovascular aneurysm repair (pEVAR) or previous open aneurysm repair (pOAR). METHODS: Data from consecutive patients who underwent F-BEVAR for pEVAR or pOAR from 2006 to 2021 from 17 European vascular centers were analyzed. Endpoints included technical success, major adverse events, 30-day mortality, and 5-year estimates of survival, target vessel primary patency, freedom from reinterventions, type I/III endoleaks, and sac growth >5 mm. BACKGROUND: Treatment of a failed previous abdominal aortic aneurysm repair is a complex undertaking. F-BEVAR is becoming an increasingly attractive option, although comparative data are limited regarding associated risk factors, indications for treatment, and various outcomes. RESULTS: There were 526 patients included, 268 pOAR and 258 pEVAR. The median time from previous repair to F-BEVAR was 7 (interquartile range, 4-12) years, 5 (3-8) for pEVAR, and 10 (6-14) for pOAR, P <0.001. Predominant indication for treatment was type Ia endoleak for pEVAR and progression of the disease for pOAR. Technical success was 92.8%, pOAR (92.2%), and pEVAR (93.4%), P =0.58. The 30-day mortality was 6.5% overall, 6.7% for pOAR, and 6.2% for pEVAR, P =0.81. There were 1853 treated target vessels with 5-year estimates of primary patency of 94.4%, pEVAR (95.2%), and pOAR (94.4%), P =0.03. Five-year estimates for freedom from type I/III endoleaks were similar between groups; freedom from reintervention was lower for pEVAR (38.3%) than for pOAR (56.0%), P =0.004. The most common indication for reinterventions was for type I/III endoleaks (37.5%). CONCLUSIONS: Repair of a failed pEVAR or pOARis safe and feasible with comparable technical success and survival rates. While successful treatment can be achieved, significant rates of reintervention should be anticipated, particularly for issues related to instability of target vessels/bridging stents.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Endofuga/epidemiología , Endofuga/cirugía , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Factores de Riesgo , Sistema de Registros , Estudios Retrospectivos , Diseño de Prótesis
16.
Ann Surg ; 278(4): 568-577, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37395613

RESUMEN

OBJECTIVE: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs). BACKGROUND: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described. METHODS: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair. RESULTS: A total of 2603 patients (69% males; mean age 72±10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P <0.001) and rates of MAEs (34% vs 20%, P <0.001). Median follow-up was 15 months (interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50±4% vs 70±1% and 21±3% vs 7±1%, P <0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality (hazard ratio, 1.92; 95% CI] 1.50-2.44; P <0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P <0.001). CONCLUSIONS: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Estudios Retrospectivos , Prótesis Vascular
17.
J Vasc Surg ; 78(2): 289-298, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37044318

RESUMEN

OBJECTIVE: The aim of this study was to assess clinical outcomes and target vessel patency through 2 years following thoracoabdominal aortic aneurysms (TAAA) repair with the off-the-shelf Zenith t-Branch Thoracoabdominal Endovascular Graft (William Cook Europe). METHODS: This post-market observational study was conducted at three European sites with ambispective enrollment from 2012 to 2017. Patients underwent endovascular TAAA repair with the t-Branch graft and bridging stent grafts (BSGs) for the celiac (CA), superior mesenteric (SMA), left renal (LRA), and/or right renal (RRA) arteries. Follow-up was through 2 years, per sites' standard of care. Procedural and 1-year results were reported previously. RESULTS: Eighty patients (mean age, 71.0±7.4 years; 70.0% men) were enrolled; six patients had symptomatic TAAAs, and 15 patients had contained ruptures. Technical success was achieved in 98.8% of patients (79/80). Median follow-up was 22.2 months (interquartile range, 9.2-25.1 months). At 24 months, Kaplan-Meier (KM) freedom from all-cause and aneurysm-related mortality were 78.5% and 98.6%, respectively. Beyond 12 months, 38 adverse events occurred in 20 patients, including two aortic ruptures (one study aneurysm and one non-study aneurysm) and six deaths (none aneurysm-related, as reported by the site). Compared with postprocedure, maximum aneurysm diameter decreased (>5 mm) in 84.6% (44/52), remained unchanged in 3.8% (2/52), and increased (>5 mm) in 11.5% (6/52) of patients with imaging follow-up after 12 months. No conversions to open repair, and no t-Branch graft or other endograft component migration or integrity issues were reported. No loss of patency was reported in the t-Branch or iliac limb grafts throughout the study. Throughout study duration, four patients had five imaging-reported BSG compressions, none of which required secondary intervention. KM freedom from secondary intervention was 76.3% at 24 months. Fourteen target vessel-related secondary interventions were performed, primarily consisting of stent placement for endoleak, stenosis, or occlusion. KM freedom from loss of primary patency was 94.8%, 100%, 91.3%, and 89.3% for the CA, SMA, LRA, and RRA, respectively, at 24 months. KM freedom from loss of secondary patency in the CA, SMA, LRA, and RRA were 96.3%, 100%, 98.2%, and 98.3% at 24 months, respectively. A total of 298 vessels were targeted, of which 12 were occluded over the study period. CONCLUSIONS: Primary and secondary target vessel patency rates through 2 years demonstrated durable repair with the t-Branch graft in patients treated for symptomatic or asymptomatic thoracoabdominal aortic aneurysms.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Resultado del Tratamiento , Factores de Riesgo , Complicaciones Posoperatorias , Stents/efectos adversos , Diseño de Prótesis
18.
J Vasc Surg ; 78(4): 863-873.e3, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37330705

RESUMEN

OBJECTIVE: Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. METHODS: A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. RESULTS: Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean ,3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. CONCLUSIONS: The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Femenino , Prótesis Vascular , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos , Estudios de Cohortes , Resultado del Tratamiento , Factores de Tiempo , Diseño de Prótesis
19.
J Vasc Surg ; 77(6): 1588-1597.e4, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36731757

RESUMEN

OBJECTIVE: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs). METHODS: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single- or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality. RESULTS: A total of 1947 patients (65% male; mean age, 71 ± 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9±1.3% vs 79.6±1.7%) and 3 years (72.7±2.1% vs 64.2±2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach. CONCLUSIONS: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years.


Asunto(s)
Aneurisma , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Prótesis Vascular , Aneurisma/cirugía , Estudios Retrospectivos , Diseño de Prótesis
20.
J Endovasc Ther ; 30(4): 609-614, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35502737

RESUMEN

PURPOSE: To describe the technical aspects and early results of a new endovascular fenestration method for false lumen occlusion in chronic aortic dissection: the Knickerbocker Technique. METHODS: A retrospective observational study including all consecutively treated patients between November 1, 2012, through May 31, 2016, who underwent thoracic endovascular aortic repair with false lumen occlusion using the Knickerbocker Technique for thoracic false lumen aneurysm in chronic aortic dissection in a tertiary care center. Primary endpoints consisted of technical (correct deployment of the stent-graft) and clinical (false lumen occlusion) success. Secondary endpoints included overall survival and morbidity after 30 days. In 12 patients, follow-up computed tomography angiogram (CTA) was available and aortic remodeling was evaluated. RESULTS: We identified 16 eligible patients (75% men, mean age: 69 years, range: 52-80 years). Technical success was 94%. Overall survival after 30 days was 100%; there was 1 aortic reintervention (additional false lumen embolization due to endoleak type 1a in 1 patient). Median total follow-up was 31.5 months (range: 3-66 months). Four (25%) of 16 patients died during follow-up, in 3 of those patients the cause of death is unknown, and 1 patient developed cardiac tamponade after being treated by fenestrated thoracic endovascular aortic repair. Imaging follow-up with CTA was available in 12 patients (median imaging follow-up: 27.5 months, range: 1-57 months). Nine (75%) of 12 patients showed thoracic aortic remodeling, and in 3 patients aneurysm size was stable. No patient showed aneurysm growth. CONCLUSION: The Knickerbocker Technique is a feasible endovascular fenestration method to achieve false lumen occlusion and aortic remodeling in chronic aortic dissection with low invasiveness.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Femenino , Prótesis Vascular , Resultado del Tratamiento , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Estudios Retrospectivos , Stents
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA