Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Ophthalmol ; 23(1): 313, 2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37438729

RESUMEN

PURPOSE: To observe the distribution characteristics of corneal higher-order aberrations (HOAs) in cataract patients, and analyze the relationship of HOAs with patients' age and ocular biometric parameters. METHODS: This retrospective study reviews the patients with cataract in Wuhan Aier Eye Department from January to August 2022. Root mean square (RMS) of the total HOA (tHOA), spherical aberration (SA), coma and trefoil aberration of the anterior cornea at central 4 and 6 mm optic zone were measured by the Wavefront Aberrometer (OPD-Scan III; Nidek Inc, Tokyo, Japan). The biometric parameters including axial length (AL), keratometry (K), central corneal thickness (CCT) and lens thickness (LT) were measured by swept-source coherence laser interferometry (OA-2000; TOMEY Corp, Aichi, Japan). Subgroup analyses and multiple linear regression analyses were used to determine whether HOAs were associated with age and ocular biometric parameters. RESULTS: A total of 976 patients (976 eyes) were included, averagely aged 65 years. At central 4 and 6 mm optic zone, the mean RMS of tHOA were respectively 0.20 and 0.65 µm, the SA were 0.06 and 0.30 µm, the coma aberration were 0.11 and 0.35 µm, and the trefoil aberration were 0.12 and 0.30 µm. The tHOA decreased with age until 60 years and then started to increase afterwards. The tHOA, coma and trefoil aberration increased with corneal astigmatism. The tHOA, SA, and coma aberration differ among different AL groups, and emmetropes had the smallest tHOA, SA, and coma aberration. CONCLUSIONS: With increasing age, the value of tHOA decrease first and started increasing at 60 years. The trends of corneal HOAs are consistent with corneal low-order aberrations. The values of tHOA, SA and coma aberration were the smallest in emmetropic eyes.


Asunto(s)
Catarata , Enfermedades de la Córnea , Humanos , Persona de Mediana Edad , Coma , Estudios Retrospectivos , Córnea
2.
J Cataract Refract Surg ; 50(1): 12-17, 2024 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-37702493

RESUMEN

PURPOSE: To compare the accuracy, safety, and consistency of asymmetric trapezoid and near-square side-port incision in cataract surgery. SETTING: Aier Eye Hospital of Wuhan University, Wuhan, Hubei Province, China. DESIGN: Prospective pilot study. METHODS: This study included patients who underwent phacoemulsification between January 2022 and August 2022. They were divided into Group A and Group B using the random number table method. Group A was given a near-square side-port incision and Group B was given an asymmetric trapezoid side-port incision. We contrasted the differences in incision length, width, and shape; surgical time; and postoperative intraocular pressure (IOP) between the 2 groups. RESULTS: 220 eyes of 220 patients were included. The mean external width of the incision in Group A was much smaller than that in Group B ( P < .01), and the consistency of the incision diameter in Group A was better than that in Group B. There was no statistically significant difference in incision length between the 2 groups ( P = .75). 1 day after surgery, there was no statistically significant difference in incision morphology between the 2 groups ( P = .72). The operating time for Group A was significantly shorter than that of Group B ( P < .01). There was no obvious incision leakage in both groups after surgery, and the IOP was generally elevated after surgery, but there was no significant statistical difference between the 2 groups ( P = .98). CONCLUSIONS: The present study suggests that a near-square side-port results in better consistency of incision width and shorter surgical time.


Asunto(s)
Extracción de Catarata , Catarata , Facoemulsificación , Herida Quirúrgica , Humanos , Estudios Prospectivos , Proyectos Piloto , Facoemulsificación/métodos , Presión Intraocular
3.
Front Bioeng Biotechnol ; 10: 855013, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35497342

RESUMEN

Hydrogels with adhesive properties have the potential for rapid haemostasis and wound healing in uncontrolled non-pressurized surface bleeding. Herein, a typical hydrogen bond-crosslinked hydrogel with the above functions was constructed by directly mixing solutions of humic acid (HA) and polyvinylpyrrolidone (PVP), in which the HA worked as a crosslinking agent to form hydrogen bonds with the PVP. By altering the concentration of HA, a cluster of stable and uniform hydrogels were prepared within 10 s. The dynamic and reversible nature of the hydrogen bonds gave the HA/PVP complex (HPC) hydrogels injectability and good flexibility, as well as a self-healing ability. Moreover, the numerous functional groups in the hydrogels enhanced the cohesion strength and interaction on the interface between the hydrogel and the substrate, endowing them with good adhesion properties. The unique chemical composition and cross-linking mechanism gave the HPC hydrogel good biocompatibility. Taking advantage of all these features, the HPC hydrogels obtained in this work were broadly applied as haemostatic agents and showed a good therapeutic effect. This work might lead to an improvement in the development of multifunctional non-covalent hydrogels for application to biomaterials.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA