Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 29(5): 2340-2349, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30488106

RESUMEN

OBJECTIVES: To compare aortic size and stiffness parameters on MRI between bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) patients with aortic stenosis (AS). METHODS: MRI was performed in 174 patients with asymptomatic moderate-severe AS (mean AVAI 0.57 ± 0.14 cm2/m2) and 23 controls on 3T scanners. Valve morphology was available/analysable in 169 patients: 63 BAV (41 type-I, 22 type-II) and 106 TAV. Aortic cross-sectional areas were measured at the level of the pulmonary artery bifurcation. The ascending and descending aorta (AA, DA) distensibility, and pulse wave velocity (PWV) around the aortic arch were calculated. RESULTS: The AA and DA areas were lower in the controls, with no difference in DA distensibility or PWV, but slightly lower AA distensibility than in the patient group. With increasing age, there was a decrease in distensibility and an increase in PWV. After correcting for age, the AA maximum cross-sectional area was higher in bicuspid vs. tricuspid patients (12.97 [11.10, 15.59] vs. 10.06 [8.57, 12.04] cm2, p < 0.001), but there were no significant differences in AA distensibility (p = 0.099), DA distensibility (p = 0.498) or PWV (p = 0.235). Patients with BAV type-II valves demonstrated a significantly higher AA distensibility and lower PWV compared to type-I, despite a trend towards higher AA area. CONCLUSIONS: In patients with significant AS, BAV patients do not have increased aortic stiffness compared to those with TAV despite increased ascending aortic dimensions. Those with type-II BAV have less aortic stiffness despite greater dimensions. These results demonstrate a dissociation between aortic dilatation and stiffness and suggest that altered flow patterns may play a role. KEY POINTS: • Both cellular abnormalities secondary to genetic differences and abnormal flow patterns have been implicated in the pathophysiology of aortic dilatation and increased vascular complications associated with bicuspid aortic valves (BAV). • We demonstrate an increased ascending aortic size in patients with BAV and moderate to severe AS compared to TAV and controls, but no difference in aortic stiffness parameters, therefore suggesting a dissociation between dilatation and stiffness. • Sub-group analysis showed greater aortic size but lower stiffness parameters in those with BAV type-II AS compared to BAV type-I.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Imagen por Resonancia Magnética , Válvula Tricúspide/diagnóstico por imagen , Rigidez Vascular , Adulto , Anciano , Aorta/fisiopatología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/patología , Aorta Torácica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/patología , Enfermedad de la Válvula Aórtica Bicúspide , Dilatación Patológica , Femenino , Enfermedades de las Válvulas Cardíacas/patología , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Análisis de la Onda del Pulso , Válvula Tricúspide/patología , Válvula Tricúspide/fisiopatología
2.
J Interv Cardiol ; 31(3): 391-399, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29696693

RESUMEN

OBJECTIVES: We sought to compare using serial CMR, the quantity of AR and associated valve hemodynamics, following the first-generation CoreValve (Medtronic, Minneapolis, MN) and the second-generation Lotus valve (Boston Scientific, Natick, MA). BACKGROUND: Aortic regurgitation (AR) following Transcatheter Aortic Valve Replacement (TAVR) confers a worse prognosis and can be accurately quantified using cardiovascular magnetic resonance (CMR). Second generation valves have been specifically designed to reduce paravalvular AR and improve clinical outcomes. METHODS: Fifty-one patients (79.0 ± 7.7 years, 57% male) were recruited and imaged at three time points: immediately pre- and post-TAVR, and at 6 months. RESULTS: CMR-derived AR fraction immediately post-TAVR was greater in the CoreValve compared to Lotus group (11.7 ± 8.4 vs. 4.3 ± 3.4%, P = 0.001), as was the frequency of ≥moderate AR (9/24 (37.5%) versus 0/27, P < 0.001). However, at 6 months AR fraction had improved significantly in the CoreValve group such that the two valve designs were comparable (6.4 ± 5.0 vs 5.6 ± 5.3%, P = 0.623), with no patient in either group having ≥moderate AR. The residual peak pressure gradient immediately following TAVR was significantly lower with CoreValve compared to Lotus (14.1 ± 5.6 vs 25.4 ± 11.6 mmHg, P = 0.001), but again by 6 months the two valve designs were comparable (16.5 ± 9.4 vs 19.7 ± 10.5 mmHg, P = 0.332). There was no difference in the degree of LV reverse remodeling between the two valves at 6 months. CONCLUSION: Immediately post-TAVR, there was significantly less AR but a higher residual peak pressure gradient with the Lotus valve compared to CoreValve. However, at 6 months both devices had comparable valve hemodynamics and LV reverse remodeling.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Imagen por Resonancia Magnética , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Femenino , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
3.
J Cardiovasc Magn Reson ; 19(1): 22, 2017 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-28222749

RESUMEN

BACKGROUND: Left bundle branch block (LBBB) is common following trans-catheter aortic valve replacement (TAVR) and has been linked to increased mortality, although whether this is related to less favourable cardiac reverse remodeling is unclear. The aim of the study was to investigate the impact of TAVR induced LBBB on cardiac reverse remodeling. METHODS: 48 patients undergoing TAVR for severe aortic stenosis were evaluated. 24 patients with new LBBB (LBBB-T) following TAVR were matched with 24 patients with a narrow post-procedure QRS (nQRS). Patients underwent cardiovascular magnetic resonance (CMR) prior to and 6 m post-TAVR. Measured cardiac reverse remodeling parameters included left ventricular (LV) size, ejection fraction (LVEF) and global longitudinal strain (GLS). Inter- and intra-ventricular dyssynchrony were determined using time to peak radial strain derived from CMR Feature Tracking. RESULTS: In the LBBB-T group there was an increase in QRS duration from 96 ± 14 to 151 ± 12 ms (P < 0.001) leading to inter- and intra-ventricular dyssynchrony (inter: LBBB-T 130 ± 73 vs nQRS 23 ± 86 ms, p < 0.001; intra: LBBB-T 118 ± 103 vs. nQRS 13 ± 106 ms, p = 0.001). Change in indexed LV end-systolic volume (LVESVi), LVEF and GLS was significantly different between the two groups (LVESVi: nQRS -7.9 ± 14.0 vs. LBBB-T -0.6 ± 10.2 ml/m2, p = 0.02, LVEF: nQRS +4.6 ± 7.8 vs LBBB-T -2.1 ± 6.9%, p = 0.002; GLS: nQRS -2.1 ± 3.6 vs. LBBB-T +0.2 ± 3.2%, p = 0.024). There was a significant correlation between change in QRS and change in LVEF (r = -0.434, p = 0.002) and between change in QRS and change in GLS (r = 0.462, p = 0.001). Post-procedure QRS duration was an independent predictor of change in LVEF and GLS at 6 months. CONCLUSION: TAVR-induced LBBB is associated with less favourable cardiac reverse remodeling at medium term follow up. In view of this, every effort should be made to prevent TAVR-induced LBBB, especially as TAVR is now being extended to a younger, lower risk population.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bloqueo de Rama/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Izquierda , Remodelación Ventricular , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Fenómenos Biomecánicos , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/fisiopatología , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Imagen por Resonancia Magnética , Masculino , Contracción Miocárdica , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Estrés Mecánico , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento
4.
J Cardiovasc Magn Reson ; 19(1): 13, 2017 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-28173819

RESUMEN

BACKGROUND: It is unknown whether circumferential strain is associated with prognosis after treatment of aortic stenosis (AS). We aimed to characterise strain in severe AS, using myocardial tagging cardiovascular magnetic resonance (CMR), prior to and following Transcatheter Aortic Valve Implantation (TAVI) and Surgical Aortic Valve Replacement (SAVR), and determine whether abnormalities in strain were associated with outcome. METHODS: CMR was performed pre- and 6 m post-intervention in 98 patients (52 TAVI, 46 SAVR; 77 ± 8 years) with severe AS. TAVI patients were older (80.9 ± 6.4 vs. 73.0 ± 7.0 years, p < 0.01) with a higher STS score (2.06 ± 0.6 vs. 6.03 ± 3.4, p < 0.001). Tagged cine images were acquired at the basal, mid and apical LV levels with a complementary spatial modulation of magnetization (CSPAMM) pulse sequence. Circumferential strain, strain rate and rotation were calculated using inTag© software. RESULTS: No significant change in basal or mid LV circumferential strain, or of diastolic strain rate, was seen following either intervention. However, a significant and comparable decline in LV torsion and twist was observed (SAVR: torsion 14.08 ± 8.40 vs. 7.81 ± 4.51, p < 0.001, twist 16.17 ± 7.01 vs.12.45 ± 4.78, p < 0.01; TAVI: torsion 14.43 ± 4.66 vs. 11.20 ± 4.62, p < 0.001, twist 16.08 ± 5.36 vs. 12.36 ± 5.21, p < 0.001) which likely reflects an improvement towards normal physiology following relief of AS. Over a maximum 6.0y follow up, there were 23 (16%) deaths following valve intervention. On multivariable Cox analysis, baseline mid LV circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01-1.05; p = 0.009) independent of age, LV ejection fraction and STS mortality risk score. ROC analysis indicated a mid LV circumferential strain > -18.7% was associated with significantly reduced survival. CONCLUSION: TAVI and SAVR procedures are associated with comparable declines in rotational LV mechanics at 6 m, with largely unchanged strain and strain rates. Pre-operative peak mid LV circumferential strain is associated with post-operative mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Área Bajo la Curva , Fenómenos Biomecánicos , Distribución de Chi-Cuadrado , Inglaterra , Femenino , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Interpretación de Imagen Asistida por Computador , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Curva ROC , Recuperación de la Función , Factores de Riesgo , Índice de Severidad de la Enfermedad , Programas Informáticos , Estrés Mecánico , Volumen Sistólico , Torsión Mecánica , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
5.
Am Heart J ; 175: 101-11, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27179729

RESUMEN

BACKGROUND: Cardiac adaptation to aortic stenosis (AS) appears to differ according to sex, but reverse remodeling after aortic valve replacement has not been extensively described. The aim of the study was to determine using cardiac magnetic resonance imaging whether any sex-related differences exist in AS in terms of left ventricular (LV) remodeling, myocardial fibrosis, and reverse remodeling after valve replacement. METHODS: One hundred patients (men, n = 60) with severe AS undergoing either transcatheter or surgical aortic valve replacement underwent cardiac magnetic resonance scans at baseline and 6 months after valve replacement. RESULTS: Despite similar baseline comorbidity and severity of AS, women had a lower indexed LV mass than did men (65.3 ± 18.4 vs 81.5 ± 21.3 g/m(2), P < .001) and a smaller indexed LV end-diastolic volume (87.3 ± 17.5 vs 101.2 ± 28.6 mL/m(2), P = .002) with a similar LV ejection fraction (58.6% ± 10.2% vs 54.8% ± 12.9%, P = .178). Total myocardial fibrosis mass was similar between sexes (2.3 ± 4.1 vs 1.3 ± 1.1 g, P = .714), albeit with a differing distribution according to sex. After aortic valve replacement, men had more absolute LV mass regression than did women (18.3 ± 10.6 vs 12.7 ± 8.8 g/m(2), P = .007). When expressed as a percentage reduction of baseline indexed LV mass, mass regression was similar between the sexes (men 21.7% ± 10.1% vs women 18.4% ± 11.0%, P = .121). There was no sex-related difference in postprocedural LV ejection fraction or aortic regurgitation. Sex was not found to be a predictor of LV reverse remodeling on multiple regression analysis. CONCLUSIONS: There are significant differences in the way that male and female hearts adapt to AS. Six months after aortic valve replacement, there are no sex-related differences in reverse remodeling, but superior reverse remodeling in men as a result of their more adverse remodeling profile at baseline.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ventrículos Cardíacos , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Tamaño de los Órganos , Periodo Posoperatorio , Factores Sexuales , Estadística como Asunto , Volumen Sistólico , Reino Unido
6.
J Cardiovasc Magn Reson ; 18(1): 37, 2016 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-27287000

RESUMEN

BACKGROUND: Aortic stiffness is increasingly used as an independent predictor of adverse cardiovascular outcomes. We sought to compare the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon aortic vascular function using cardiovascular magnetic resonance (CMR) measurements of aortic distensibility and pulse wave velocity (PWV). METHODS AND RESULTS: A 1.5 T CMR scan was performed pre-operatively and at 6 m post-intervention in 72 patients (32 TAVI, 40 SAVR; age 76 ± 8 years) with high-risk symptomatic severe aortic stenosis. Distensibility of the ascending and descending thoracic aorta and aortic pulse wave velocity were determined at both time points. TAVI and SAVR patients were comparable for gender, blood pressure and left ventricular ejection fraction. The TAVI group were older (81 ± 6.3 vs. 72.8 ± 7.0 years, p < 0.05) with a higher EuroSCORE II (5.7 ± 5.6 vs. 1.5 ± 1.0 %, p < 0.05). At 6 m, SAVR was associated with a significant decrease in distensibility of the ascending aorta (1.95 ± 1.15 vs. 1.57 ± 0.68 × 10(-3)mmHg(-1), p = 0.044) and of the descending thoracic aorta (3.05 ± 1.12 vs. 2.66 ± 1.00 × 10(-3)mmHg(-1), p = 0.018), with a significant increase in PWV (6.38 ± 4.47 vs. 11.01 ± 5.75 ms(-1), p = 0.001). Following TAVI, there was no change in distensibility of the ascending aorta (1.96 ± 1.51 vs. 1.72 ± 0.78 × 10(-3)mmHg(-1), p = 0.380), descending thoracic aorta (2.69 ± 1.79 vs. 2.21 ± 0.79 × 10(-3)mmHg(-1), p = 0.181) nor in PWV (8.69 ± 6.76 vs. 10.23 ± 7.88 ms(-1), p = 0.301) at 6 m. CONCLUSIONS: Treatment of symptomatic severe aortic stenosis by SAVR but not TAVI was associated with an increase in aortic stiffness at 6 months. Future work should focus on the prognostic implication of these findings to determine whether improved patient selection and outcomes can be achieved.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Imagen por Resonancia Cinemagnética , Reemplazo de la Válvula Aórtica Transcatéter , Rigidez Vascular , Anciano , Anciano de 80 o más Años , Aorta Torácica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Inglaterra , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Análisis de la Onda del Pulso , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
J Magn Reson Imaging ; 42(4): 946-53, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25857628

RESUMEN

PURPOSE: To demonstrate the feasibility of an automatic adaptive acquisition sequence. Magnetic resonance perfusion pulse sequences often leave potential acquisition time unused in patients with lower heart-rates (HR) and smaller body size. MATERIALS AND METHODS: A perfusion technique was developed that automatically adapts to HR and field-of-view by maximizing in-plane spatial resolution while maintaining temporal resolution every cardiac cycle. Patients (n = 10) and volunteers (n = 10) were scanned with both a standard resolution and adaptive method. Image quality was scored, signal-to-noise ratio (SNR) calculated, and width of dark-rim artifact (DRA) measured. RESULTS: The acquired spatial resolution of the adaptive sequence (1.92 × 1.92 mm(2) ± 0.34) was higher than the standard resolution (2.42 × 2.42 mm(2) ) (P < 0.0001). Mean DRA width was reduced using the adaptive pulse sequence (1.94 ± 0.60 mm vs. 2.82 ± 0.65 mm, P < 0.0001). The signal-to-noise ratio (SNR) was higher with the standard pulse sequence (6.7 ± 2.2 vs. 3.8 ± 1.8, P < 0.0001). There was no difference in image quality score between sequences in either volunteers (1.1 ± 0.31 vs. 1.0 ± 0.0, P = 0.34) or patients (1.3 ± 0.48 vs. 1.3 ± 0.48, P = 1.0). CONCLUSION: Optimizing the use of available imaging time during first-pass perfusion with a magnetic resonance imaging pulse sequence that adapts image acquisition duration to HR and patient size is feasible. Acquired in-plane spatial resolution is improved, the DRA is reduced, and while SNR is reduced with the adaptive sequence consistent with the lower voxel size used, image quality is maintained.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Enfermedad de la Arteria Coronaria/patología , Prueba de Esfuerzo/métodos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Adulto , Anciano , Tamaño Corporal , Estudios de Factibilidad , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Persona de Mediana Edad , Medicina de Precisión/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
8.
J Cardiovasc Magn Reson ; 17(1): 4, 2015 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-25630861

RESUMEN

BACKGROUND: Myocardial blood flow (MBF) varies throughout the cardiac cycle in response to phasic changes in myocardial tension. The aim of this study was to determine if quantitative myocardial perfusion imaging with cardiovascular magnetic resonance (CMR) can accurately track physiological variations in MBF throughout the cardiac cycle. METHODS: 30 healthy volunteers underwent a single stress/rest perfusion CMR study with data acquisition at 5 different time points in the cardiac cycle (early-systole, mid-systole, end-systole, early-diastole and end-diastole). MBF was estimated on a per-subject basis by Fermi-constrained deconvolution. Interval variations in MBF between successive time points were expressed as percentage change. Maximal cyclic variation (MCV) was calculated as the percentage difference between maximum and minimum MBF values in a cardiac cycle. RESULTS: At stress, there was significant variation in MBF across the cardiac cycle with successive reductions in MBF from end-diastole to early-, mid- and end-systole, and an increase from early- to end-diastole (end-diastole: 4.50 ± 0.91 vs. early-systole: 4.03 ± 0.76 vs. mid-systole: 3.68 ± 0.67 vs. end-systole 3.31 ± 0.70 vs. early-diastole: 4.11 ± 0.83 ml/g/min; all p values <0.0001). In all cases, the maximum and minimum stress MBF values occurred at end-diastole and end-systole respectively (mean MCV = 26 ± 5%). There was a strong negative correlation between MCV and peak heart rate at stress (r = -0.88, p < 0.001). The largest interval variation in stress MBF occurred between end-systole and early-diastole (24 ± 9% increase). At rest, there was no significant cyclic variation in MBF (end-diastole: 1.24 ± 0.19 vs. early-systole: 1.28 ± 0.17 vs.mid-systole: 1.28 ± 0.17 vs. end-systole: 1.27 ± 0.19 vs. early-diastole: 1.29 ± 0.19 ml/g/min; p = 0.71). CONCLUSION: Quantitative perfusion CMR can be used to non-invasively assess cyclic variations in MBF throughout the cardiac cycle. In this study, estimates of stress MBF followed the expected physiological trend, peaking at end-diastole and falling steadily through to end-systole. This technique may be useful in future pathophysiological studies of coronary blood flow and microvascular function.


Asunto(s)
Circulación Coronaria , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Imagen de Perfusión Miocárdica/métodos , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Adulto Joven
9.
J Cardiovasc Magn Reson ; 16: 19, 2014 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-24565078

RESUMEN

BACKGROUND: Two-dimensional (2D) perfusion cardiovascular magnetic resonance (CMR) remains limited by a lack of complete myocardial coverage. Three-dimensional (3D) perfusion CMR addresses this limitation and has recently been shown to be clinically feasible. However, the feasibility and potential clinical utility of quantitative 3D perfusion measurements, as already shown with 2D-perfusion CMR and positron emission tomography, has yet to be evaluated. The influence of systolic or diastolic acquisition on myocardial blood flow (MBF) estimates, diagnostic accuracy and image quality is also unknown for 3D-perfusion CMR. The purpose of this study was to establish the feasibility of quantitative 3D-perfusion CMR for the detection of coronary artery disease (CAD) and to compare systolic and diastolic estimates of MBF. METHODS: Thirty-five patients underwent 3D-perfusion CMR with data acquired at both end-systole and mid-diastole. MBF and myocardial perfusion reserve (MPR) were estimated on a per patient and per territory basis by Fermi-constrained deconvolution. Significant CAD was defined as stenosis ≥70% on quantitative coronary angiography. RESULTS: Twenty patients had significant CAD (involving 38 out of 105 territories). Stress MBF and MPR had a high diagnostic accuracy for the detection of CAD in both systole (area under curve [AUC]: 0.95 and 0.92, respectively) and diastole (AUC: 0.95 and 0.94). There were no significant differences in the AUCs between systole and diastole (p values >0.05). At stress, diastolic MBF estimates were significantly greater than systolic estimates (no CAD: 3.21 ± 0.50 vs. 2.75 ± 0.42 ml/g/min, p < 0.0001; CAD: 2.13 ± 0.45 vs. 1.98 ± 0.41 ml/g/min, p < 0.0001); but at rest, there were no significant differences (p values >0.05). Image quality was higher in systole than diastole (median score 3 vs. 2, p = 0.002). CONCLUSIONS: Quantitative 3D-perfusion CMR is feasible. Estimates of MBF are significantly different for systole and diastole at stress but diagnostic accuracy to detect CAD is high for both cardiac phases. Better image quality suggests that systolic data acquisition may be preferable.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Circulación Coronaria , Estenosis Coronaria/diagnóstico , Vasos Coronarios/fisiopatología , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética , Imagen de Perfusión Miocárdica/métodos , Anciano , Área Bajo la Curva , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Diástole , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Sístole , Factores de Tiempo
10.
J Cardiovasc Magn Reson ; 16: 34, 2014 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-24886614

RESUMEN

BACKGROUND: Aberrant coronary arteries represent a diverse group of congenital disorders. Post-mortem studies reveal a high risk of exercise-related sudden cardiac death in those with an anomalous coronary artery originating from the opposite sinus of Valsalva (ACAOS) with an inter-arterial course. There is little documentation of lifetime history and long-term follow-up of patients with coronary artery anomalies. METHODS: Patients with anomalous coronary arteries undergoing cardiovascular magnetic resonance over a 15-year period were identified and classified by anatomy and course. Medical records were reviewed for major adverse cardiovascular events (MACE). Revascularisation or myocardial infarction counted only if occurring in the distribution of the anomalous artery. RESULTS: Consecutive patients with coronary artery anomalies were retrospectively identified (n = 172). Median follow-up time was 4.3 years (IQR 2.5-7.8, maximum 15.6). 116 patients had ACAOS of which 64 (55%) had an inter-arterial course (IAC) and 52 (45%) did not. During follow up 110 ACAOS patients were alive, 5 died and 1 lost to follow-up.ACAOS patients experienced 58 MACE events (5 cardiovascular deaths, 5 PCI, 24 CABG and 24 had myocardial infarction). 47 MACE events occurred in ACAOS with IAC and 11 in those without (p < 0.0001), the statistical difference driven by surgical revascularisation and myocardial infarction. CONCLUSIONS: In life, patients with an anomalous coronary artery originating from the opposite sinus of Valsalva taking an IAC have higher rates of both myocardial infarction and surgical revascularisation during long-term follow up, compared to those without IAC.


Asunto(s)
Anomalías de los Vasos Coronarios/diagnóstico , Vasos Coronarios/patología , Imagen por Resonancia Magnética , Seno Aórtico/anomalías , Centros de Atención Terciaria , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Puente de Arteria Coronaria , Anomalías de los Vasos Coronarios/complicaciones , Anomalías de los Vasos Coronarios/mortalidad , Anomalías de los Vasos Coronarios/patología , Anomalías de los Vasos Coronarios/terapia , Inglaterra , Humanos , Lactante , Estimación de Kaplan-Meier , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Adulto Joven
11.
Radiology ; 268(1): 26-43, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23793590

RESUMEN

Cardiac masses are usually first detected at echocardiography. In their further evaluation, cardiac magnetic resonance (MR) imaging has become a highly valuable technique. MR imaging offers incremental value owing to its larger field of view, superior tissue contrast, versatility in image planes, and unique ability to enable discrimination of different tissue characteristics, such as water and fat content, which give rise to particular signal patterns with T1- and T2-weighted techniques. With contrast material-enhanced MR imaging, additional tissue properties such as vascularity and fibrosis can be demonstrated. MR imaging can therefore contribute to the diagnosis of a cardiac mass as well as be used to detail its relationship to other cardiac and extracardiac structures. These assessments are important to plan therapy, such as surgical intervention. In addition, serial MR studies can be used to monitor tumor regression after surgery or chemotherapy. Primary cardiac tumors are very rare; metastases and pseudotumors (eg, thrombus) are much more common. This article provides an overview of cardiac masses and reviews the optimal MR imaging techniques for their assessment.


Asunto(s)
Neoplasias Cardíacas/diagnóstico , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Diagnóstico Diferencial , Ecocardiografía , Fibrosis/diagnóstico , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Neovascularización Patológica/diagnóstico , Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
12.
J Cardiovasc Magn Reson ; 15: 58, 2013 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-23806080

RESUMEN

BACKGROUND: Following acute myocardial infarction (AMI), microvascular obstruction (MO) and intramyocardial hemorrhage (IMH) adversely affect left ventricular remodeling and prognosis independently of infarct size. Whether this is due to infarct zone remodeling, changes in remote myocardium or other factors is unknown. We investigated the role of MO and IMH in recovery of contractility in infarct and remote myocardium. METHODS: Thirty-nine patients underwent cardiovascular magnetic resonance (CMR) with T2-weighted and T2* imaging, late gadolinium enhancement (LGE) and myocardial tagging at 2, 7, 30 and 90 days following primary percutaneous coronary intervention for AMI. Circumferential strain in infarct and remote zones was stratified by presence of MO and IMH. RESULTS: Overall, infarct zone strain recovered with time (p < 0.001). In the presence of MO with IMH and without IMH, epicardial strain recovered (p = 0.03, p < 0.01 respectively), but mid-myocardial or endocardial strain did not (mid-myocardium: p = 0.05, p = 0.12; endocardium: p = 0.27, p = 0.05, respectively). By day 90, infarcts with MO had more attenuated strain in all myocardial layers compared to infarcts without MO (p < 0.01); those with IMH were attenuated further (p < 0.01). Remote myocardial strain was similar across groups at all time-points (p > 0.2). Infarct transmural extent did not correlate with strain (p > 0.05 at each time point). In multivariable logistic regression, MO and IMH were the only significant independent predictors of attenuated 90-day infarct zone strain (p = 0.004, p = 0.011, respectively). CONCLUSIONS: Strain improves within the infarct zone overall following reperfusion with or without MO or IMH. Mid-myocardial and endocardial infarct contractility is diminished in the presence of MO, and further in the presence of IMH. MO and IMH are greater independent predictors of infarct zone contractile recovery than infarct volume or transmural extent.


Asunto(s)
Ventrículos Cardíacos/fisiopatología , Hemorragia/fisiopatología , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Infarto del Miocardio/terapia , Reperfusión Miocárdica/métodos , Fenómeno de no Reflujo/fisiopatología , Intervención Coronaria Percutánea , Función Ventricular Izquierda , Anciano , Fenómenos Biomecánicos , Medios de Contraste , Circulación Coronaria , Inglaterra , Femenino , Gadolinio DTPA , Ventrículos Cardíacos/patología , Hemorragia/diagnóstico , Hemorragia/etiología , Humanos , Masculino , Microcirculación , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/fisiopatología , Reperfusión Miocárdica/efectos adversos , Fenómeno de no Reflujo/diagnóstico , Fenómeno de no Reflujo/etiología , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Remodelación Ventricular
13.
J Cardiovasc Dev Dis ; 10(3)2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36975884

RESUMEN

Objective: We aimed to study the long-term association of LV mass index (LVMI) and myocardial fibrosis with ventricular arrhythmia (VA) in a population of patients with confirmed hypertrophic cardiomyopathy (HCM) using cardiac magnetic resonance imaging (CMR). Methods: We retrospectively analyzed the data in consecutive HCM patients confirmed on CMR referred to an HCM clinic between January 2008 and October 2018. Patients were followed up yearly following diagnosis. Baseline demographics, risk factors and clinical outcomes from cardiac monitoring and an implanted cardioverter defibrillator (ICD) were analyzed for association of LVMI and LV late gadolinium enhancement (LVLGE) with VA. Patients were then allocated to one of two groups according to the presence of VA (Group A) or absence of VA (Group B) during the follow-up period. The transthoracic echocardiogram (TTE) and CMR parameters were compared between the two groups. Results: A total of 247 patients with confirmed HCM (age 56.2 ± 16.6, male = 71%) were studied over the follow-up period of 7 ± 3.3 years (95% CI = 6.6-7.4 years). LVMI derived from CMR was higher in Group A (91.1 ± 28.1 g/m2 vs. 78.8 ± 28.3 g/m2, p = 0.003) when compared to Group B. LVLGE was higher in Group A (7.3 ± 6.3% vs. 4.7 ± 4.3%, p = 0.001) when compared to Group B. Multivariable Cox regression analysis showed LVMI (hazard ratio (HR) = 1.02, 95% CI = 1.001-1.03, p = 0.03) and LVLGE (HR = 1.04, 95% CI = 1.001-1.08, p = 0.04) to be independent predictors for VA. Receiver operative curves showed higher LVMI and LVLGE with a cut-off of 85 g/m2 and 6%, respectively, to be associated with VA. Conclusions: LVMI and LVLGE are strongly associated with VA over long-term follow-up. LVMI requires more thorough studies to consider it as a risk stratification tool in patients with HCM.

14.
Int J Cardiovasc Imaging ; 35(1): 161-170, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30182320

RESUMEN

Current echocardiographic data reporting the impact of concomitant mitral regurgitation (MR) on outcome in patients who undergo transcatheter aortic valve replacement (TAVR) are conflicting. Using cardiovascular magnetic resonance (CMR) imaging, this study aimed to assess the impact of MR severity on cardiac reverse remodeling and patient outcome. 85 patients undergoing TAVR with CMR pre- and 6 m post-TAVR were evaluated. The CMR protocol included cines for left (LV) and right ventricular (RV) volumes, flow assessment, and myocardial scar assessment by late gadolinium enhancement (LGE). Patients were dichotomised according to CMR severity of MR fraction at baseline ('non-significant' vs 'significant') and followed up for a median duration of 3 years. Forty-two (49%) patients had 'significant MR' at baseline; they had similar LV and RV size and function compared to the 'non-significant MR' group but had greater LV mass at baseline. In those with significant MR at baseline, 77% (n = 32) had a reduction in MR post-TAVR, moving them into the 'non-significant' category at 6-months, with an overall reduction in MR fraction from 34 to 17% (p < 0.001). Improvement in MR was not associated with more favourable cardiac reverse remodeling when compared with the 'non-improvers'. Significant MR at baseline was not associated with increased mortality at follow-up. Significant MR is common in patients undergoing TAVR and improves in the majority post-procedure. Improvement in MR was not associated with more favourable LV reverse remodeling and baseline MR severity was not associated with mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Imagen por Resonancia Cinemagnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
15.
BMJ Open ; 9(1): e022329, 2019 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-30670503

RESUMEN

OBJECTIVE: To compare the incidence of silent cerebral infarction and impact on cognitive function following transcatheter aortic valve implantation (TAVI) with the first-generation CoreValve (Medtronic, Minneapolis, Minnesota, USA) and second-generation Lotus valve (Boston Scientific, Natick Massachusetts, USA). DESIGN: A prospective observational study comprising a 1.5 T cerebral MRI scan, performed preoperatively and immediately following TAVI, and neurocognitive assessments performed at baseline, 30 days and 1 year follow-up. SETTING: University hospitals of Leeds and Leicester, UK. PATIENTS: 66 (80.6±8.0 years, 47% male) patients with high-risk severe symptomatic aortic stenosis recruited between April 2012 and May 2015. MAIN OUTCOME MEASURES: Incidence of new cerebral microinfarction and objective decline in neurocognitive performance. RESULTS: All underwent cerebral MRI at baseline and immediately following TAVI, and 49 (25 Lotus, 24 CoreValve) completed neurocognitive assessments at baseline, 30 days and 1 year. There was a significantly greater incidence of new cerebral microinfarction observed following the Lotus TAVI (23 (79%) vs 22 (59%), p=0.025) with a greater number of new infarcts per patient (median 3.5 (IQR 7.0) vs 2.0 (IQR 3.0), p=0.002). The mean volume of infarcted cerebral tissue per patient was equivalent following the two prostheses (p=0.166). More patients suffered new anterior (14 (48%) vs 2 (5%), p=0.001) and vertebrobasilar (15 (52%) vs 7 (19%), p=0.005) lesions following Lotus. Lotus was associated with a decline in verbal memory and psychomotor speed at 30 days. However, performance longitudinally at 1 year was preserved in all neurocognitive domains. CONCLUSIONS: There was a higher incidence of silent cerebral microinfarction and a greater number of lesions per patient following Lotus compared with CoreValve. However, there was no objective decline in neurocognitive function discernible at 1 year following TAVI with either prosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Infarto Cerebral/fisiopatología , Cognición , Prótesis Valvulares Cardíacas/clasificación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Infarto Cerebral/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Masculino , Pruebas de Estado Mental y Demencia , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Reino Unido
17.
JRSM Open ; 8(2): 2054270416685207, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28203386

RESUMEN

Rare case of concurrent subarachnoid haemorrhage and ST elevation myocardial infarction, highlighting the importance of detailed history in an emergency.

18.
Quant Imaging Med Surg ; 7(1): 38-47, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28275558

RESUMEN

BACKGROUND: Symptomatic severe aortic stenosis (AS) is a class I indication for replacement in patients when left ventricular ejection fraction (LVEF) is preserved. However, symptom reporting is often equivocal and decision making can be challenging. We aimed to quantify myocardial deformation using cardiovascular magnetic resonance (CMR) in patients classified by symptom severity. METHODS: Forty-two patients with severe AS referred to heart valve clinic were studied using tagged CMR imaging. All had preserved LVEF. Patients were grouped by symptoms as either "none/mild" (n=21, NYHA class I, II) or "significant" (n=21, NYHA class III, IV, angina, syncope) but were comparable for age (72.8±5.4 vs. 71.0±6.8 years old, P=0.345), surgical risk (EuroSCORE II: 1.90±1.7 vs. 1.31±0.4, P=0.302) and haemodynamics (peak aortic gradient: 55.1±20.8 vs. 50.4±15.6, P=0.450). Thirteen controls matched in age and LVEF were also studied. LV circumferential strain was calculated using inTag© software and longitudinal strain using feature tracking analysis. RESULTS: Compared to healthy controls, patients with severe AS had significantly worse longitudinal and circumferential strain, regardless of symptom status. Patients with "significant" symptoms had significantly worse peak longitudinal systolic strain rates (-83.352±24.802%/s vs. -106.301±43.276%/s, P=0.048) than those with "no/mild" symptoms, with comparable peak longitudinal strain (PLS), peak circumferential strain and systolic and diastolic strain rates. CONCLUSIONS: Patients with severe AS who have no or only mild symptoms exhibit comparable reduction in circumferential and longitudinal fibre function to those with significant symptoms, in whom AVR is clearly indicated. Given these findings of equivalent subclinical dysfunction, reportedly borderline symptoms should be handled cautiously to avoid potentially adverse delays in intervention.

19.
EuroIntervention ; 13(2): e153-e160, 2017 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-28117280

RESUMEN

AIMS: Myocardial injury assessed using cardiac biomarker release is ubiquitous following surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI), preventing accurate discrimination between focal myocardial infarction (MI) and global injury. Cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) imaging was used to compare rates of new MI following SAVR and TAVI. METHODS AND RESULTS: Identical CMR scans were obtained at baseline and six months post procedure in ninety-six patients undergoing SAVR (n=39) and TAVI (n=57). The rate of new MI was greater following SAVR than TAVI (SAVR, n=10 [26%] vs. TAVI, n=3 [5%], p=0.004). Infarct mass was similar between groups (SAVR 1.1±0.6 vs. TAVI 2.0±1.4 g, p=0.395). New MI did not impact on change in LV ejection fraction (SAVR:LGE[+]2.2±4.7 vs. LGE[-]0.9±8.0%, p=0.437, TAVI:LGE[+]-0.9±6.0 vs. LGE[-]2.0±7.8%, p=0.420). Thirty-four patients (60%) in the TAVI group had non-revascularised coronary artery disease (CAD) at the time of TAVI, of whom three (9%) had new MI. CONCLUSIONS: MI is an infrequent complication of TAVI but is more common following SAVR. Infarct size is small following both procedures. The low new infarct rate in TAVI, especially in the context of high rates of non-revascularised CAD, strengthens data from previous studies suggesting that coronary revascularisation pre-TAVI may be unnecessary.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Infarto del Miocardio/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Medios de Contraste/administración & dosificación , Angiografía Coronaria , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
20.
JACC Cardiovasc Imaging ; 10(9): 989-999, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-27771398

RESUMEN

OBJECTIVES: In the setting of reperfused acute myocardial infarction (AMI), the authors sought to compare prediction of contractile recovery by infarct extracellular volume (ECV), as measured by T1-mapping cardiac magnetic resonance (CMR), with late gadolinium enhancement (LGE) transmural extent. BACKGROUND: The transmural extent of myocardial infarction as assessed by LGE CMR is a strong predictor of functional recovery, but accuracy of the technique may be reduced in AMI. ECV mapping by CMR can provide a continuous measure associated with the severity of tissue damage within infarcted myocardium. METHODS: Thirty-nine patients underwent acute (day 2) and convalescent (3 months) CMR scans following AMI. Cine imaging, tissue tagging, T2-weighted imaging, modified Look-Locker inversion T1 mapping natively and 15 min post-gadolinium-contrast administration, and LGE imaging were performed. The ability of acute infarct ECV and acute transmural extent of LGE to predict convalescent wall motion, ejection fraction (EF), and strain were compared per-segment and per-patient. RESULTS: Per-segment, acute ECV and LGE transmural extent were associated with convalescent wall motion score (p < 0.01; p < 0.01, respectively). ECV had higher accuracy than LGE extent to predict improved wall motion (area under receiver-operating characteristics curve 0.77 vs. 0.66; p = 0.02). Infarct ECV ≤0.5 had sensitivity 81% and specificity 65% for prediction of improvement in segmental function; LGE transmural extent ≤0.5 had sensitivity 61% and specificity 71%. Per-patient, ECV and LGE correlated with convalescent wall motion score (r = 0.45; p < 0.01; r = 0.41; p = 0.02, respectively) and convalescent EF (p < 0.01; p = 0.04). ECV and LGE extent were not significantly correlated (r = 0.34; p = 0.07). In multivariable linear regression analysis, acute infarct ECV was independently associated with convalescent infarct strain and EF (p = 0.03; p = 0.04), whereas LGE was not (p = 0.29; p = 0.24). CONCLUSIONS: Acute infarct ECV in reperfused AMI can complement LGE assessment as an additional predictor of regional and global LV functional recovery that is independent of transmural extent of infarction.


Asunto(s)
Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Función Ventricular Izquierda , Anciano , Área Bajo la Curva , Medios de Contraste/administración & dosificación , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Recuperación de la Función , Reproducibilidad de los Resultados , Infarto del Miocardio con Elevación del ST/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA