Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Asunto principal
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 2968-2974, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35125260

RESUMEN

OBJECTIVE: Acute kidney injury (AKI) is a common perioperative complication in patients undergoing cardiovascular surgery, increasing mortality, morbidities, and costs. Recently, growing interest has risen in the use of the renal-resistive index (RRI) as a predictor of perioperative AKI. The aim of this study was to evaluate the role of RRI variation to identify postoperative AKI. DESIGN: An observational, prospective, pilot study. SETTING: Department of Vascular Surgery, University Hospital of Padova. PARTICIPANTS: The study authors included 53 consecutive patients undergoing aortic surgery from September 2018 to June 2019. MEASUREMENTS AND MAIN RESULTS: Basal and daily postoperative serum creatinine and urine output were assessed. RRI was measured preoperatively and on the first postoperative day. AKI was defined using Kidney Disease Improving Global Outcome criteria. Twelve patients out of 53 developed AKI. The RRI percentage increase (%RRI) was associated with the development of AKI by univariate regression (p = 0.01). The receiver operating characteristic curve showed an overall diagnostic accuracy of 0.75 (95% confidence interval [CI], 58.2-92.6). The cutoff of 7 percentage points in the %RRI resulted in early identification of AKI onset with 90% specificity (95% CI, 76.9-97.3). The net benefit of postoperative RRI-based management was 11%. CONCLUSIONS: RRI variation could be a useful tool to investigate kidney function in patients undergoing aortic surgery. The %RRI in the perioperative time seems to detect AKI onset early and potentially could enhance renal-protective management within 24 hours after surgery.


Asunto(s)
Lesión Renal Aguda , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Creatinina , Humanos , Riñón , Proyectos Piloto , Estudios Prospectivos
2.
Life (Basel) ; 13(1)2022 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-36675977

RESUMEN

After fluid status optimization, norepinephrine infusion represents the cornerstone of septic shock treatment. De-escalation of vasopressors should be considered with caution, as hypotension increases the risk of mortality. In this prospective observational study including 42 patients, we assess the role of dynamic elastance (EaDyn), i.e., the ratio between pulse pressure variation and stroke volume variation, which can be measured noninvasively by the MostCare monitoring system, to predict a mean arterial pressure (MAP) drop > 10% 30 min after norepinephrine reduction. Patients were divided into responders (MAP falling > 10%) and non-responders (MAP falling < 10%). The receiver-operating-characteristic curve identified an area under the curve of the EaDyn value to predict a MAP decrease > 10% of 0.84. An EaDyn cut-off of 0.84 predicted a MAP drop > 10% with a sensitivity of 0.71 and a specificity of 0.89. In a multivariate logistic regression, EaDyn was significantly and independently associated with MAP decrease (OR 0.001, 95% confidence interval 0.00001−0.081, p < 0.001). The nomogram model for the probability of MAP decrease > 10% showed a C-index of 0.90. In conclusion, in a septic shock cohort, EaDyn correlates well with the risk of decrease of MAP > 10% after norepinephrine reduction.

3.
J Clin Med ; 10(2)2021 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-33435270

RESUMEN

There are no reliable, non-invasive methods to accurately measure cardiac output (CO) in septic patients. MostCare (Vytech Health™, Vygon, Padova, Italy), is a beat-to-beat, self calibrated method for CO measurement based on continuous analysis of reflected arterial pressure waveforms. We enrolled 40 patients that were suffering from septic shock and requiring norepinephrine infusion to target blood pressure in order to to evaluate the level of agreement between a calibrated transpulmonary thermodilution device (PiCCO System, Pulsion Medical Systems, Feldkirchen, Germany) and the MostCare system in detecting and tracking changes in CO measurements related to norepinephrine reduction in septic shock patients,. PiCCO was connected to a 5 Fr femoral artery catheter and to a central venous catheter. System calibration was performed with 15 mL of cold saline injection over about 3 s. The MostCare device was connected to the artery catheter to analyze the arterial waveform. Before reducing norepinephrine infusion, the PiCCO system was calibrated, the MostCare waveform was optimized, and the values of the complete hemodynamic profile were recorded (T1). Norepinephrine infusion was then reduced by 0.03 mcg/Kg/min. After 30 min, a new calibration of PiCCO system and a new record on both monitors were performed (T2). Static measurements agreements were assessed using the Bland-Altman test, while trending ability was investigated using polar plot analysis. If volume expansion occurred, then related data were separately analyzed. At T1 mean the CO was 5.38 (SD 0.60) L/min, the mean difference was 0.176 L/min, the limits of agreement (LoA) was +1.39 and -1.04 L/min, and the percentage error (PE) was 22.6%; at T2 the mean CO was 5.44 (SD 0.73) L/min, the mean difference was 0.053 L/min, the LoA was +1.51 and -1.40, and the PE was 27%. After considering the volume expansion between T1 and T2, the mean CO at T1 was 5.39 L/min (SD 0.47), the LoA was +1.09 and -0.78 L/min, and the percentage error (PE) was 17%; at T2 the mean CO was 5.35 L/min (SD 0.81), the LoA was +1.73 and -1.52 L/min, and the PE was 30%. The polar plot diagram seems to confirm the trending ability of MostCare system versus the reference method. In septic patients, when the arterial waveform is accurate, MostCare and PiCCO transpulmonary thermodilution exhibit good agreement even after the reduction of norepinephrine and changes in vascular tone or volume expansion. MostCare could be a rapid to set, reliable, and useful tool to monitor hemodynamic variations in septic patients in emergency contexts where thermodilution methods or other advanced systems are not easily available.

4.
Ultrasound J ; 13(1): 10, 2021 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-33624222

RESUMEN

BACKGROUND: During COVID-19 pandemic, optimization of the diagnostic resources is essential. Lung Ultrasound (LUS) is a rapid, easy-to-perform, low cost tool which allows bedside investigation of patients with COVID-19 pneumonia. We aimed to investigate the typical ultrasound patterns of COVID-19 pneumonia and their evolution at different stages of the disease. METHODS: We performed LUS in twenty-eight consecutive COVID-19 patients at both admission to and discharge from one of the Padua University Hospital Intensive Care Units (ICU). LUS was performed using a low frequency probe on six different areas per each hemithorax. A specific pattern for each area was assigned, depending on the prevalence of A-lines (A), non-coalescent B-lines (B1), coalescent B-lines (B2), consolidations (C). A LUS score (LUSS) was calculated after assigning to each area a defined pattern. RESULTS: Out of 28 patients, 18 survived, were stabilized and then referred to other units. The prevalence of C pattern was 58.9% on admission and 61.3% at discharge. Type B2 (19.3%) and B1 (6.5%) patterns were found in 25.8% of the videos recorded on admission and 27.1% (17.3% B2; 9.8% B1) on discharge. The A pattern was prevalent in the anterosuperior regions and was present in 15.2% of videos on admission and 11.6% at discharge. The median LUSS on admission was 27.5 [21-32.25], while on discharge was 31 [17.5-32.75] and 30.5 [27-32.75] in respectively survived and non-survived patients. On admission the median LUSS was equally distributed on the right hemithorax (13; 10.75-16) and the left hemithorax (15; 10.75-17). CONCLUSIONS: LUS collected in COVID-19 patients with acute respiratory failure at ICU admission and discharge appears to be characterized by predominantly lateral and posterior non-translobar C pattern and B2 pattern. The calculated LUSS remained elevated at discharge without significant difference from admission in both groups of survived and non-survived patients.

5.
Ann Intensive Care ; 10(1): 133, 2020 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-33044646

RESUMEN

BACKGROUND: A Covid-19 outbreak developed in Lombardy, Veneto and Emilia-Romagna (Italy) at the end of February 2020. Fear of an imminent saturation of available ICU beds generated the notion that rationing of intensive care resources could have been necessary. RESULTS: In order to evaluate the impact of Covid-19 on the ICU capacity to manage critically ill patients, we performed a retrospective analysis of the first 2 weeks of the outbreak (February 24-March 8). Data were collected from regional registries and from a case report form sent to participating sites. ICU beds increased from 1545 to 1989 (28.7%), and patients receiving respiratory support outside the ICU increased from 4 (0.6%) to 260 (37.0%). Patients receiving respiratory support outside the ICU were significantly older [65 vs. 77 years], had more cerebrovascular (5.8 vs. 13.1%) and renal (5.3 vs. 10.0%) comorbidities and less obesity (31.4 vs. 15.5%) than patients admitted to the ICU. PaO2/FiO2 ratio, respiratory rate and arterial pH were higher [165 vs. 244; 20 vs. 24 breath/min; 7.40 vs. 7.46] and PaCO2 and base excess were lower [34 vs. 42 mmHg; 0.60 vs. 1.30] in patients receiving respiratory support outside the ICU than in patients admitted to the ICU, respectively. CONCLUSIONS: Increase in ICU beds and use of out-of-ICU respiratory support allowed effective management of the first 14 days of the Covid-19 outbreak, avoiding resource rationing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA