Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cardiovasc Drugs Ther ; 36(4): 705-712, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-33988835

RESUMEN

PURPOSE: The clinical course of COVID-19 may be complicated by acute respiratory distress syndrome (ARDS) and thromboembolic events, which are associated with high risk of mortality. Although previous studies reported a lower rate of death in patients treated with heparin, the potential benefit of chronic oral anticoagulation therapy (OAT) remains unknown. We aimed to investigate the association between OAT with the risk of ARDS and mortality in hospitalized patients with COVID-19. METHODS: This is a multicenter retrospective Italian study including consecutive patients hospitalized for COVID-19 from March 1 to April 22, 2020, at six Italian hospitals. Patients were divided into two groups according to the chronic assumption of oral anticoagulants. RESULTS: Overall, 427 patients were included; 87 patients (19%) were in the OAT group. Of them, 54 patients (13%) were on treatment with non-vitamin k oral anticoagulants (NOACs) and 33 (8%) with vitamin-K antagonists (VKAs). OAT patients were older and had a higher rate of hypertension, diabetes, and coronary artery disease compared to No-OAT group. The rate of ARDS at admission (26% vs 28%, P=0.834), or developed during the hospitalization (9% vs 10%, P=0.915), was similar between study groups; in-hospital mortality (22% vs 26%, P=0.395) was also comparable. After balancing for potential confounders by using the propensity score matching technique, no differences were found in term of clinical outcome between OAT and No-OAT patients CONCLUSION: Oral anticoagulation therapy, either NOACs or VKAs, did not influence the risk of ARDS or death in patients hospitalized with COVID-19.


Asunto(s)
Fibrilación Atrial , COVID-19 , Síndrome de Dificultad Respiratoria , Administración Oral , Anticoagulantes , Fibrilación Atrial/tratamiento farmacológico , Fibrinolíticos/uso terapéutico , Humanos , Estudios Retrospectivos , Vitamina K
2.
Catheter Cardiovasc Interv ; 93(7): E394-E399, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30536530

RESUMEN

BACKGROUND: Trans-catheter closure of coronary artery fistulae (CAF) has become a successful alternative to cardiac surgery with excellent results and acceptable low rate of complications. Different techniques and devices are available to treat the extreme anatomical variability of CAF. AIM: We retrospectively describe our case series of five patients trans-radially treated using an Amplatzer vascular plug IV (AVP-IV) with telescoping catheter technique. RESULTS: Trans-radial closure of CAF using the "Child in Mother" technique with dedicated catheters to deliver the vascular plugs AVP-IV was successfully performed in all patients, in one case for a complex CAF, an hybrid step approach using coils and plugs was needed. CONCLUSIONS: Trans-radial closure of CAF using AVP-IV and a telescoping catheter appeared to be safe and feasible in our case series. A persistent closure of CAF was achieved in all patients at 2 year coronary angiography follow-up.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Cateterismo Periférico , Anomalías de los Vasos Coronarios/terapia , Embolización Terapéutica/instrumentación , Arteria Radial , Fístula Vascular/terapia , Adulto , Anciano , Aleaciones , Cateterismo Cardíaco/efectos adversos , Catéteres Cardíacos , Cateterismo Periférico/efectos adversos , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/fisiopatología , Embolización Terapéutica/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Punciones , Estudios Retrospectivos , Resultado del Tratamiento , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/fisiopatología
3.
Catheter Cardiovasc Interv ; 93(1): E56-E62, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244510

RESUMEN

BACKGROUND: Iatrogenic hemorrhagic pericardial tamponade (IHPT) represents a life-threating condition requiring emergency pericardiocentesis. In this clinical context, reinfusion of pericardial blood can stabilize the patient and sustain hemodynamic conditions. AIMS AND METHODS: We reviewed all cases of IHPT occurred at our hospital over a 10 years span. In all patient autologous blood reinfusion through a femoral vein was performed. RESULTS: In our clinical experience of 30 consecutive patients with hemorrhagic cardiac tamponade, this technique was successful to limit blood transfusions, to prevent further clinical worsening and bridge patients with intractable bleeding, to cardiac surgery. No major adverse reactions were directly related to blood autotransfusion. CONCLUSION: In the complex clinical scenario of acute tamponade occurring during catheter-based cardiac procedures, autotransfusion of pericardial blood through a femoral vein is safe and effective. It can be a useful trick up the sleeve of the interventional cardiologist.


Asunto(s)
Transfusión de Sangre Autóloga , Cateterismo Cardíaco/efectos adversos , Taponamiento Cardíaco/terapia , Vena Femoral , Hemorragia/terapia , Enfermedad Iatrogénica , Pericardiocentesis , Anciano , Anciano de 80 o más Años , Transfusión de Sangre Autóloga/efectos adversos , Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/etiología , Estudios de Factibilidad , Femenino , Hemorragia/diagnóstico por imagen , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Pericardiocentesis/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
4.
Eur Heart J ; 39(26): 2448-2456, 2018 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-29788263

RESUMEN

Aims: Delayed healing and endothelial dysfunction may occur with drug-eluting stents (DES), promoting accelerated infiltration of lipids in the neointima and development of neoatherosclerosis (NA). Pathology data suggest durable polymer (DP) of DES to play a major role in this process. Whether biodegradable polymer (BP) may address these issues is uncertain. We compared in vivo vessel healing and NA of current generation BP- or DP-DES using serial optical coherence tomography (OCT) assessments. Methods and results: Ninety patients with multivessel coronary artery disease were randomized 1:1 to BP everolimus-eluting stents (EES, Synergy) or DP zotarolimus-eluting stents (ZES, Resolute Integrity). Co-primary endpoints were the maximum length of uncovered struts at 3 months (powered for non-inferiority) and the percentage of patients presenting with frames of NA at 18 months (powered for superiority) as measured by OCT. The maximum length of uncovered struts at 3 months was 10 ± 8 mm in the BP-EES group and 11 ± 7 mm in the DP-ZES group (mean difference -1 mm; upper 97.5% confidence interval +2 mm; P = 0.05 for non-inferiority; P = 0.45 for superiority). The percentage of patients presenting with frames of NA at 18 months was low and similar between BP-EES and DP-ZES groups (11.6% vs. 15.9%; P = 0.56). There was no stent thrombosis in both groups at 24 months. Conclusion: BP-EES and DP-ZES showed a similar healing response at 3 months and a low incidence of NA at 18 months. Biocompatible polymers, regardless of whether they are durable or biodegradable, may favourably impact the long-term vascular response to current-generation DES.


Asunto(s)
Implantes Absorbibles , Aterosclerosis/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Neointima/diagnóstico por imagen , Intervención Coronaria Percutánea , Anciano , Materiales Biocompatibles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Everolimus/administración & dosificación , Femenino , Humanos , Inmunosupresores/administración & dosificación , Masculino , Persona de Mediana Edad , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Factores de Tiempo , Tomografía de Coherencia Óptica , Cicatrización de Heridas
5.
Catheter Cardiovasc Interv ; 91(1): 97-102, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28463463

RESUMEN

OBJECTIVES: to understand the role of a transradial (TR) secondary approach during complex percutaneous interventions. BACKGROUND: The value of the TR route for ancillary vascular approach has not been adequately validated in this setting, and there is scant data on its role in reducing bleeding complications. METHODS: In the present study we retrospectively included patients undergoing the following interventions requiring two vascular approaches at nine high-volume centers in Italy: structural cardiac interventions, complex PCI, endovascular aortic repair (EVAR) and complex lower limb angioplasty. We compared procedural outcomes according to the type of ancillary vascular approach selected, namely TR or transfemoral/transbrachial (TF/TB). Primary endpoints of the study were procedural success and in-hospital BARC grade 3-5 bleedings. RESULTS: We included 906 patients, 433 receiving TR and 473 TF/TB ancillary approaches. Baseline characteristics did not differ significantly. Patients underwent the following types of intervention: structural 50%, complex coronary PCI 37%, EVAR 11%, peripheral angioplasty 2%. Procedural success was similar (90% in TR and 92% TF/TB, P = NS). In-hospital BARC 3/5 bleedings were more common in TF/TB group as compared to TR group (19.7% vs. 6.7%,P < 0.001). In TF/TB group we also observed a higher postprocedural hemoglobin drop (1.92 vs 1.13 g/dl, P = 0.008) and longer hospital stay as compared to TR group. Similar results were observed in a propensity score-matched population of 450 patients. CONCLUSIONS: In our study TR ancillary approach was associated with a significant reduction in the risk of major bleedings, without jeopardizing the success of complex structural, coronary, and peripheral percutaneous interventions. The value of the transradial route for ancillary vascular approach during percutaneous interventions has not been adequately validated yet. We retrospectively included 906 patients, 433 receiving TR and 473 TF/TB ancillary approach at nine high-volume centers for the following interventions: structural cardiac interventions, complex PCI, EVAR and complex peripheral angioplasty. Procedural success was similar, whereas in-hospital BARC bleedings were more common in the transfemoral/brachial group. Similar results were observed in a propensity score-matched population. In our study TR ancillary approach was associated with a significant reduction in the risk of major bleedings, without jeopardizing the success of complex interventions. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Enfermedad de la Arteria Coronaria/terapia , Procedimientos Endovasculares/métodos , Arteria Femoral , Enfermedades Vasculares Periféricas/terapia , Arteria Radial , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Periférico/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Hemorragia/etiología , Hemorragia/prevención & control , Humanos , Italia , Masculino , Persona de Mediana Edad , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Punciones , Arteria Radial/diagnóstico por imagen , Sistema de Registros , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 84(5): 734-41, 2014 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-24948549

RESUMEN

BACKGROUND: The Cappella Sideguard (CS) sidebranch stent is a self-expanding, thin-strut, nitinol device with anatomic flaring at the sidebranch ostium designed to treat bifurcation lesions. OBJECTIVE: To evaluate the mechanism of long-term lumen patency of the novel, self-expanding CS sidebranch stent compared with a balloon-expandable stent in the main vessel. METHODS: We performed intravascular ultrasound postintervention and at follow-up in 24 CS stents and in 28 balloon-expandable drug-eluting stents deployed in the corresponding main vessel. Thirteen patients also had optical coherence tomography (OCT) at follow-up to evaluate neointimal hyperplasia and strut coverage. RESULTS: CS stent area at the sidebranch carina increased significantly from 3.8 ± 1.2 mm(2) postintervention to 4.6 ± 1.2 mm(2) at follow-up (P < 0.001), resulting in no change in lumen area (3.8 ± 1.2 mm(2) to 3.7 ± 1.2 mm(2) , P = 0.72) despite a neointimal area at follow-up of 0.9 ± 0.8 mm(2) . Volumetric changes were similar, and the distribution of neointimal hyperplasia peaked 1-2 mm distal to the carina. Change of lumen volume inversely correlated to the neointimal volume (R = -0.48, P < 0.001), but correlated positively to the change in stent volume (R = 0.52, P < 0.0001). By OCT, most CS struts were covered (100% [98.9, 100]) at the bifurcation site, whereas 61% of floating DES struts that crossed the sidebranch were covered by smooth tissue with a similar texture compared with neointima. CONCLUSION: Although neointimal hyperplasia accumulates within the CS stent mainly 1-2 mm distal to the carina, the self-expanding CS stent may be effective in maintaining an adequate patency in the sidebranch by continued stent expansion noted at follow-up.


Asunto(s)
Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Grado de Desobstrucción Vascular/fisiología , Anciano , Aleaciones , Análisis de Varianza , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Distribución de Chi-Cuadrado , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Neointima/patología , Neointima/fisiopatología , Docilidad , Estudios Prospectivos , Diseño de Prótesis , Estadísticas no Paramétricas
7.
Catheter Cardiovasc Interv ; 82(5): 748-54, 2013 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-23592513

RESUMEN

OBJECTIVES: We compared the mechanisms of lumen gain after Cappella Sideguard (CS) side branch (SB) bifurcation stent deployment versus a balloon-expandable stent in the corresponding main vessel (MV). BACKGROUND: The novel CS SB bifurcation stent is a self-expanding, thin-strut, nitinol device with anatomic flaring at the SB ostium. METHODS: In 28 bifurcation lesions, intravascular ultrasound imaging of both the SB and the MV was performed both pre- and postintervention; vessel and lumen areas were measured every 1 mm over a 5 mm segment beginning at the carina. RESULTS: Although minimum lumen area (MLA) within the distal 5 mm segment beginning at the carina increased from 2.8 ± 1.3 mm(2) to 3.8 ± 1.1 mm(2), P < 0.001, in the SB and from 3.4 ± 1.4 mm(2) to 6.0 ± 1.1 mm(2), P < 0.001, in the MV, stent expansion (minimum stent area/distal reference lumen area) was significantly less in the SB compared with the MV (77.8 ± 21.3% vs. 91.6 ± 18.4%, P = 0.02). Post stenting, the MLA site was located at the carina more frequently in the SB (85.7%) than in the MV (60.7%), P = 0.04. Plaque volume in the 5 mm proximal to carina in the MV tended to decrease, whereas plaque volume in the SB increased slightly with no change in overall plaque volume in the 5-mm-long segment distal to the carina in the MV, suggesting plaque shift from the proximal MV to the SB. CONCLUSIONS: Acute CS lumen gain is less than the lumen gain of a balloon-expandable stent in the MV because of less aggressive acute expansion and/or the plaque shift from the proximal MV to the SB.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Ultrasonografía Intervencional , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 81(3): 510-8, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22431208

RESUMEN

BACKGROUND: New generation drug-eluting stents (DES) incorporate thinner struts and novel alloys to improve clinical performance. Nevertheless, the impact of novel stent materials and designs on human vascular response to DES remains elusive. We sought to evaluate the in-vivo coronary artery response to platinum-chromium (PtCr) versus cobalt-chromium (CoCr) stents featuring the same durable polymer and antiproliferative drug by optical coherence tomography (OCT). METHODS AND RESULTS: A total of 42 patients with de novo lesions in native coronary vessels was treated with PtCr-everolimus eluting stent (EES; n = 21) or CoCr-EES (n = 21). Angiography, intravascular ultrasound, and OCT were performed at the index procedure and 6-month follow-up. PtCr-EES and CoCr-EES had similar concentric expansion (stent eccentricity index; median 0.91 vs. 0.90, respectively, P = 0.47) and very low rate of strut malapposition (median 1.15 vs. 1.80%, P = 0.92) at post implantation. Proportion of struts embedded in tissue was lower in PtCr-EES compared to CoCr-EES (median 2.67 vs. 15.23%, P < 0.001). The primary prespecified end point, the percentage of uncovered struts per patient at 6 months follow-up, was 8.46% [interquartile range (IQR) = 3.05-17.26] in PtCr-EES and 5.88% (IQR = 1.35-13.27) in CoCr-EES (P = 0.36), whereas malapposed struts were observed in 0.00% (IQR = 0.00-0.25) versus 0.48% (IQR = 0.00-1.44), respectively, (P = 0.10). Strut-level neointimal thickness did not differ between the two platforms (median 0.09 vs. 0.08 mm, P = 0.49). CONCLUSIONS: Acute and mid-term responses to EES using PtCr or CoCr platforms were similar, with concentric stent expansion, low malapposition, similar strut coverage and limited amount of neointima. Conversely, at postprocedure, PtCr-EES had fewer embedded struts compared with CoCr-EES.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Revascularización Miocárdica/instrumentación , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica/métodos , Anciano , Antineoplásicos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Everolimus , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sirolimus/farmacología , Ultrasonografía Intervencional
9.
Circulation ; 123(3): 274-81, 2011 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-21220730

RESUMEN

BACKGROUND: The safety of drug-eluting stents in ST-segment elevation myocardial infarction (STEMI) continues to be debated. Pathological studies have demonstrated an association between uncovered struts and subsequent stent thrombosis. Optical coherence tomography can detect stent strut coverage in vivo on a micron-scale level. We therefore used optical coherence tomography to examine strut coverage in patients with STEMI treated with paclitaxel-eluting stents (PES) and bare metal stents (BMS). METHODS AND RESULTS: In the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, patients with STEMI were randomized 3:1 to PES or BMS implantation. In a formal substudy, optical coherence tomography at 13 months was performed in 118 consecutive randomized patients (89 PES, 29 BMS) in whom 188 stents were assessed (146 PES and 42 BMS). A total of 44 139 stent struts were analyzed by an independent core laboratory blinded to stent assignment. The primary prespecified end point, the percentage of uncovered stent struts per lesion at follow-up, was 1.1 ± 2.5% in BMS lesions versus 5.7 ± 7.0% in PES lesions (P < 0.0001). Malapposed struts were observed in 0.1 ± 0.2% of BMS lesions versus 0.9 ± 2.1% of PES lesions (P = 0.0003). Percentage net volume obstruction was 36.0 ± 15.4% with BMS and 19.2 ± 11.3% with PES (P < 0.0001). CONCLUSIONS: In patients with STEMI undergoing primary percutaneous coronary intervention, implantation of PES as compared with BMS significantly reduces neointimal hyperplasia but results in higher rates of uncovered and malapposed stent struts as assessed by optical coherence tomography at 13-month follow-up. Further studies are required to determine the clinical significance of these findings. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00433966.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Stents Liberadores de Fármacos/efectos adversos , Infarto del Miocardio/terapia , Neointima/etiología , Paclitaxel/administración & dosificación , Tomografía de Coherencia Óptica , Anciano , Trombosis Coronaria/etiología , Trombosis Coronaria/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Metales , Persona de Mediana Edad , Infarto del Miocardio/patología , Neointima/patología , Estudios Prospectivos , Moduladores de Tubulina/administración & dosificación
10.
Catheter Cardiovasc Interv ; 80(3): 395-405, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22109961

RESUMEN

BACKGROUND: Bleeding has emerged as a predictor of early and late mortality after percutaneous coronary interventions. However, the prevalence and predictors of long-term bleeding events in patients on prolonged dual antiplatelet therapy (DAPT) after drug-eluting stent (DES) implantation has been poorly explored. METHODS: A total of 1,437 patients undergoing DES implantation discharged on DAPT with aspirin and clopidogrel for 1 year were studied. Patients were followed for up to 4 years (34.3 ± 14.4 months) and the prevalence and predictors of in-hospital and long-term thrombolysis in myocardial infarction (TIMI) major and minor bleeding events evaluated. The impact of bleeding events on major adverse cardiac events (MACE), overall death, and stent thrombosis (ST) was also assessed. RESULTS: The incidences of 30 days major and minor bleeding were 1.3 and 3.3%, respectively. The incidences of 1-year major and minor bleeding were 3.0 and 5.6%, respectively. The incidences of major and minor bleeding up to 4-year follow-up were 3.6 and 6.9%, respectively. At multivariable analysis, 1-year major bleeding was positively predicted by use of oral anticoagulants at hospital discharge [odds ratio (OR) = 13.4, 95% confidence interval (CI) 3.0-59.2, P = 0.001], anemia at admission (OR = 6.7, 95% CI = 2.7-16.5, P < 0.001) and use of glycoprotein IIb/IIIa inhibitors (OR = 2.7, 95% CI = 1.1-6.5, P = 0.03) and negatively predicted by male gender (OR = 0.39, 95% CI = 0.16-0.97, P = 0.042). Overall, major bleeding at 1 year and at long-term follow-up was associated with an increased risk of MACE, cardiac death and ST. Patients who had any bleeding event were more likely to prematurely discontinue antiplatelet therapy (50% vs. 9.6%, P < 0.001). CONCLUSIONS: In DES-treated patients on prolonged DAPT, major bleeding occurring at 1 year and up to 4 years following DES implantation in patients on prolonged DAPT is associated with poor long-term prognosis.


Asunto(s)
Aspirina/efectos adversos , Enfermedad de la Arteria Coronaria/terapia , Trombosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Hemorragia/inducido químicamente , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/efectos adversos , Ticlopidina/análogos & derivados , Anciano , Aspirina/administración & dosificación , Distribución de Chi-Cuadrado , Clopidogrel , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Quimioterapia Combinada , Femenino , Hemorragia/mortalidad , Humanos , Incidencia , Italia , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Prevalencia , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Ticlopidina/administración & dosificación , Ticlopidina/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
11.
Indian Heart J ; 62(3): 226-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21275298

RESUMEN

BACKGROUND AND PURPOSE: Transradial approach for diagnostic and interventional procedures is becoming common practice. It has not been well determined how many times the same radial artery can be cannulated without complications. Aim of the study was to evaluate safety, feasibility and efficacy of repeat transradial procedures. METHODS: From May 1998 to March 2009 we studied 4818 consecutive patients (75.44% male; age 64.02 +/- 11.6 Years) via radial artery by a single experienced operator. RESULTS: A repeat transradial procedure through the same radial artery was performed in 670 patients: twice in 514 cases, three times in 119, four times in 25 patients, five times in 7 patients, six times in 3 patients and seven times in one patient. Repeat PCI was performed in 412 patients. 6F catheters were used in 98.11%. There was no significant difference in radial puncture success rate and vascular access time: puncture success rate was 99.23% in the initial procedure and 98.11% (5 puncture failure) in repeated transradial artery procedures, and vascular access time was 1.5 +/- 2.1 min at the initial procedure and 2.2 +/- 3.1 min at repeat (p = ns). CONCLUSIONS: Failure of repeat puncture may be due to thickening of the tunica intima resulting from sheath insertion injuries or because of periarterial fibrosis at the prior radial puncture site. We believe that repeated use of the same radial artery is effective in considering its high procedural success and low complication rates in majority of patients in the hands of experienced operators.


Asunto(s)
Angioplastia Coronaria con Balón , Brazo/irrigación sanguínea , Cateterismo Periférico/métodos , Arteria Radial/cirugía , Angiografía , Brazo/diagnóstico por imagen , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Persona de Mediana Edad , Punciones , Arteria Radial/diagnóstico por imagen , Retratamiento , Estadísticas no Paramétricas
12.
Indian Heart J ; 62(3): 255-7, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21275304

RESUMEN

BACKGROUND AND PURPOSE: Right transradial approach (TRA) for cardiovascular procedures is becoming common practice, but angiography and PCI of left mammary artery by-pass graft (LIMA) via the right radial artery is still technically challenging. Aim of the study was to evaluate the possibility to put a stable catheter in left mammary from right radial approach. METHODS: From June 2002 to March 2009, 246 consecutive patients (88% male; age 67.7 +/- 7.8 years) with previous CABG underwent LIMA graft angiography via right TRA by a single experienced operator. RESULTS: An adequate radial access was obtained in all patients. Selective angiography of LIMA was successfully performed in 218 patients (89.1%). In the remaining 28 (10.9%) the LIMA approach from right radial failed because of severe tortuosity of brachiocephalic trunk or severe calcified and tortuous left subclavian artery. 13 patients underwent PCI and stentingon mid-distal native LAD trough LIMA using 6FIM4 guiding catheter. No periprocedural cerebro-vascular complications, no vascular injury at the LIMA takeoff as a result of selective canulation, no injury of the left subclavian artery were observed CONCLUSIONS: In patients with previous CABG, the presence of LIMA grafts is not a limitation to successfully perform diagnostic and interventional procedures via the right radial approach with experienced operators.


Asunto(s)
Angiografía/métodos , Cateterismo Cardíaco/métodos , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/cirugía , Anastomosis Interna Mamario-Coronaria , Arterias Mamarias/diagnóstico por imagen , Arterias Mamarias/cirugía , Arteria Radial/diagnóstico por imagen , Anciano , Puente de Arteria Coronaria , Estudios de Factibilidad , Femenino , Humanos , Masculino , Arteria Subclavia/diagnóstico por imagen , Resultado del Tratamiento
13.
J Invasive Cardiol ; 30(6): 218-223, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29543187

RESUMEN

BACKGROUND: Distal transradial access in the anatomical snuffbox has advantages over standard access in terms of patient and operator comfort levels and risk of ischemia. Radial artery preservation could be a relevant issue in patients requiring multiple radial artery procedures and coronary bypass with the use of a radial graft. One relevant drawback is the challenging puncture of a small and weak artery, with a steeper learning curve. AIM: The study was aimed at proving feasibility and safety of right and left transradial access in the anatomical snuffbox. METHODS: All 52 consecutive patients assigned to only one operator program underwent diagnostic or procedural intervention through distal transradial access in the anatomical snuffbox. RESULTS: The overall feasibility was 90%, greater than expected in our early clinical experience, with 47 successful accesses out of 52 patients. Failures were due to proximal radial artery occlusion and hypoplastic/vasospastic distal radial artery. CONCLUSION: Distal transradial access in the anatomical snuffbox is an appealing and feasible option for both patients and operators. Further studies are needed to evaluate the clinical benefits conferred by this approach.


Asunto(s)
Cateterismo Cardíaco/métodos , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Arteria Radial/cirugía , Anciano , Cateterismo Cardíaco/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos
14.
J Invasive Cardiol ; 30(6): E48-E49, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29799428

RESUMEN

Percutaneous aortic balloon valvuloplasty as a bridge-to-decision strategy was performed in an 89-year-old woman with multiple comorbidities and cachexia. The patient did well; after 2 weeks, she was discharged home and referred for possible TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Aortografía/métodos , Femenino , Humanos , Arteria Radial/cirugía
15.
Cardiovasc Revasc Med ; 18(7): 504-506, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28600020

RESUMEN

Trans-ulnar access is a viable alternative approach by experienced operators when the radial and femoral arteries cannot be accessed or used to preserve the contralateral radial artery as possible vascular graft for coronary bypass surgery, hemodynamic monitoring, or shunt creation for hemodialysis. We report a challenging case of ipsilateral trans-ulnar recanalization of a chronic radial artery occlusion, which allowed us to perform a complex trans-ulnar PCI.


Asunto(s)
Angioplastia de Balón , Arteriopatías Oclusivas/terapia , Cateterismo Periférico , Oclusión Coronaria/terapia , Intervención Coronaria Percutánea , Arteria Radial , Arteria Cubital , Angiografía , Angioplastia de Balón/instrumentación , Arteriopatías Oclusivas/complicaciones , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Enfermedad Crónica , Constricción Patológica , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Punciones , Arteria Radial/diagnóstico por imagen , Arteria Radial/fisiopatología , Resultado del Tratamiento , Arteria Cubital/diagnóstico por imagen , Grado de Desobstrucción Vascular
16.
G Ital Cardiol (Rome) ; 18(4): 322-324, 2017 Apr.
Artículo en Italiano | MEDLINE | ID: mdl-28492572

RESUMEN

Iatrogenic coronary and aortic dissection is one of the worst complication during a percutaneous coronary intervention. Nevertheless, it can be approached and effectively resolved by a percutaneous way, sealing the false lumen "entry door" with a covered stent, even if this device is more thrombogenic than other bare-metal or drug-eluting stents. We report the case of a 60-year-old man with acute ST-elevation myocardial infarction complicated by both iatrogenic dissection and multiple stent thrombosis.


Asunto(s)
Aorta/lesiones , Vasos Coronarios/lesiones , Intervención Coronaria Percutánea , Humanos , Enfermedad Iatrogénica , Masculino , Persona de Mediana Edad
17.
Cardiovasc Revasc Med ; 18(3): 154-159, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28119043

RESUMEN

BACKGROUND: Transradial approach (TRA) for percutaneous coronary procedures is associated with improved patient outcome and is being increasingly adopted worldwide. We surveyed Italian interventional cardiologists in order to take a snapshot of the current practice of TRA. METHODS: A web-based questionnaire was emailed to all members of the Italian Society of Interventional Cardiology. RESULTS: The survey was taken by 508 respondents. Cardiogenic shock and chronic total occlusions represented the principal limitations to TRA. Right TRA was the default approach for 81% of respondents. Both diagnostic and interventional procedures were routinely performed through 6 Fr sheaths (83% and 93%, respectively); dedicated TRA curves were used in 11% of diagnostic and in about 3% of interventional procedures. Almost 70% of the operators did not assess dual hand circulation. In case of crossover, the contralateral radial artery was the preferred site (57%). Radial artery hemostasis was mostly achieved by pneumatic bracelet (64%) and patency of the radial artery during hemostasis was ensured in 60% of cases. Pre-discharge patency of the radial artery was routinely assessed by almost 60% of respondents. For diagnostic procedures, adequate heparin anticoagulation (5000IU) was only given by 45% of operators. Most respondents believed that TRA is associated with greater radiation exposure for both the patient (82%) and the operator (98%) as compared to transfemoral approach. CONCLUSIONS: This survey provides contemporary data about the adoption of TRA in Italy and gives interesting insights about several technical and clinical issues related to the practice of this vascular approach for coronary procedures.


Asunto(s)
Cateterismo Cardíaco/tendencias , Intervención Coronaria Percutánea/tendencias , Pautas de la Práctica en Medicina/tendencias , Arteria Radial , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Catéteres Cardíacos/tendencias , Toma de Decisiones Clínicas , Diseño de Equipo , Encuestas de Atención de la Salud , Humanos , Italia , Exposición Profesional , Selección de Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Arteria Radial/diagnóstico por imagen , Dosis de Radiación , Exposición a la Radiación , Radiografía Intervencional/tendencias , Factores de Riesgo , Sociedades Médicas
18.
Int J Cardiol ; 233: 52-60, 2017 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-28188002

RESUMEN

OBJECTIVE: The aim of this study was to investigate interactions among pre-procedural aortic regurgitation (AR), post-procedural paravalvular leak (PVL) and long-term clinical outcomes. METHODS AND RESULTS: We analyzed data prospectively collected in the Italian Transcatheter balloon-Expandable Registry (ITER) on aortic stenosis (AS) patients. The degree of pre-procedural AR and post-procedural PVL was stratified as: absent/trivial, mild, and moderate/severe. VARC definitions were applied to outcomes. Of 1708 patients, preoperatively, AR was absent/trivial in 40% of the patients, mild in 42%, and moderate in 18%. Postoperatively, PVL was moderate-severe in 5%, mild in 32% of patients, and absent/trivial in 63%. Clinical follow-up, median 821days (IQR 585.75), was performed in 99.7% of patients. PVL, but not preoperative AR, was a major predictor of adverse outcome (HR 1.33, CI 95% 0.9-2.05, p=0.012 for mild PVL, HR 1.36, CI 95% 0.9-2.05, p<0.001 for PVL≥moderate and OR 1.04, p=0.97 respectively). Patients with moderate-severe PVL and preoperative left ventricle (LV) dilatation (LVEDVi>75ml/m2) showed better survival than those without dilatation (HR 8.63, p=0.001). CONCLUSIONS: In patients with severe AS treated with balloon-expandable TAVI, the presence of PVL, but not pre-procedural AR, was a major predictor of adverse outcome. Preoperative LV dilatation seemed to offer some clinical advantages.


Asunto(s)
Insuficiencia de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/mortalidad , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Pronóstico , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias
19.
Am J Cardiol ; 119(9): 1438-1442, 2017 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28325569

RESUMEN

Advanced chronic kidney disease (CKD) is associated with poor outcomes in patients who underwent surgical aortic valve replacement, whereas its prognostic role in transcatheter aortic valve implantation (TAVI) remains unclear. This study aimed to investigate outcomes in patients with advanced CKD who underwent TAVI. A total of 1,904 consecutive patients who underwent balloon-expandable TAVI in 33 centers between 2007 and 2012 were enrolled in the Italian Transcatheter Balloon-Expandable Valve Implantation Registry. Advanced CKD was defined according to the estimated glomerular filtration rate: 15 to 29 ml/min/1.73 m2 stage 4 (S4), <15 ml/min/1.73 m2 stage 5 (S5). Edwards Sapien or Sapien-XT prosthesis were used. The primary end point was all-cause mortality during follow-up. Secondary end points were major adverse cardiac events at 30 days and at follow-up, defined with Valve Academic Research Consortium 2 criteria. A total of 421 patients were staged S5 (n = 74) or S4 (n = 347). S5 patients were younger and had more frequently porcelain aorta and a lower incidence of previous stroke. Periprocedural and 30-day outcomes were similar in S5 and S4 patients. During 670 (±466) days of follow-up, S5 patients had higher mortality rates (69% vs 39%, p <0.01) and cardiac death (19% vs 9%, p = 0.02) compared with S4 patients. Male gender (hazard ratio [HR] 1.6, 95% confidence interval [CI] 1.2 to 2.2), left ventricular ejection fraction <30% (HR 2.3, 95% CI 1.3 to 4), atrial fibrillation (HR 1.4, 95% CI 1.0 to 1.9), and S5 CKD (HR 1.5, 95% CI 1.0 to 2.1) were independent predictors of death. In conclusion, TAVI in predialytic or dialytic patients (i.e., S5) is independently associated with poor outcomes with more than double risk of death compared with patients with S4 renal function. Conversely, in severe CKD (i.e., S4) a rigorous risk stratification is required to avoid the risk of futility risk.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Tasa de Filtración Glomerular , Fallo Renal Crónico/terapia , Mortalidad , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Diálisis Renal , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Fibrilación Atrial/epidemiología , Femenino , Humanos , Fallo Renal Crónico/complicaciones , Masculino , Modelos de Riesgos Proporcionales , Insuficiencia Renal Crónica/complicaciones , Índice de Severidad de la Enfermedad , Factores Sexuales , Volumen Sistólico , Resultado del Tratamiento
20.
Cardiovasc Revasc Med ; 17(5): 339-43, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27053437

RESUMEN

Despite remarkable advances in the interventional landscape, device delivery during percutaneous coronary intervention (PCI) can still present technical challenges especially when performed in complex anatomical settings and through radial approach. To overcome difficult coronary stent delivery, several strategies have been developed. A niche option in such complex cases is the anchoring balloon technique, which involves inflation of a balloon non-coaxially in a side branch or distally to the target lesion in a coaxial fashion, to facilitate stent delivery. However, the main limitation of this technique is the requirement of a large guide catheter (≥7French) which may preclude the use of radial approach. We describe, step-by-step, the distal anchoring ballooning technique performed by a 6Fr radial approach to overcome the stent delivery failure in complex anatomical scenarios and to safely and successfully carry out the PCI procedures.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Enfermedad de la Arteria Coronaria/terapia , Arteria Radial , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Cateterismo Periférico/instrumentación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos , Humanos , Masculino , Punciones , Arteria Radial/diagnóstico por imagen , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA