Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
EBioMedicine ; 101: 105030, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38394744

RESUMEN

BACKGROUND: Chronic lung allograft dysfunction (CLAD) encompasses three main phenotypes: bronchiolitis obliterans syndrome (BOS), restrictive allograft syndrome (RAS) and a Mixed phenotype combining both pathologies. How the airway structure in its entirety is affected in these phenotypes is still poorly understood. METHODS: A detailed analysis of airway morphometry was applied to gain insights on the effects of airway remodelling on the distribution of alveolar ventilation in end-stage CLAD. Ex vivo whole lung µCT and tissue-core µCT scanning of six control, six BOS, three RAS and three Mixed explant lung grafts (9 male, 9 female, 2014-2021, Leuven, Belgium) were used for digital airway reconstruction and calculation of airway dimensions in relation to luminal obstructions. FINDINGS: BOS and Mixed explants demonstrated airway obstructions of proximal bronchioles (starting at generation five), while RAS explants particularly had airway obstructions in the most distal bronchioles (generation >12). In BOS and Mixed explants 76% and 84% of bronchioles were obstructed, respectively, while this was 22% in RAS. Bronchiolar obstructions were mainly caused by lymphocytic inflammation of the airway wall or fibrotic remodelling, i.e. constrictive bronchiolitis. Proximal bronchiolectasis and imbalance in distal lung ventilation were present in all CLAD phenotypes and explain poor lung function and deterioration of specific lung function parameters. INTERPRETATION: Alterations in the structure of conducting bronchioles revealed CLAD to affect alveolar ventilatory distribution in a regional fashion. The significance of various obstructions, particularly those associated with mucus, is highlighted. FUNDING: This research was funded with the National research fund Flanders (G060322N), received by R.V.


Asunto(s)
Obstrucción de las Vías Aéreas , Bronquiolitis Obliterante , Trasplante de Pulmón , Humanos , Masculino , Femenino , Pulmón/diagnóstico por imagen , Pulmón/patología , Bronquiolitis Obliterante/diagnóstico por imagen , Bronquiolitis Obliterante/etiología , Trasplante de Pulmón/efectos adversos , Fenotipo , Estudios Retrospectivos
2.
Lung India ; 41(3): 230-248, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38704658

RESUMEN

Pleural effusion is a common problem in our country, and most of these patients need invasive tests as they can't be evaluated by blood tests alone. The simplest of them is diagnostic pleural aspiration, and diagnostic techniques such as medical thoracoscopy are being performed more frequently than ever before. However, most physicians in India treat pleural effusion empirically, leading to delays in diagnosis, misdiagnosis and complications from wrong treatments. This situation must change, and the adoption of evidence-based protocols is urgently needed. Furthermore, the spectrum of pleural disease in India is different from that in the West, and yet Western guidelines and algorithms are used by Indian physicians. Therefore, India-specific consensus guidelines are needed. To fulfil this need, the Indian Chest Society and the National College of Chest Physicians; the premier societies for pulmonary physicians came together to create this National guideline. This document aims to provide evidence based recommendations on basic principles, initial assessment, diagnostic modalities and management of pleural effusions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA