Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 184
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Chem ; 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39245958

RESUMEN

BACKGROUND: Timely and accurate notification of critical results is crucial in laboratory medicine and mandated by accreditation standards like ISO15189. Alert lists do, however, vary widely and clinical laboratories typically rely on a combination of in-house agreed and/or literature-based critical values. Communication by phone is still the preferred method of notification, but digital communication could help improve communication of critical results. CONTENT: We review the available evidence concerning critical result thresholds and critical result notification practices. The evidence is ranked using an adaptation of the Stockholm Hierarchy. In addition, we propose an evidence-based list of critical result thresholds for hospitalized patients that laboratories can use as a starter list and further customize based on the clinical needs of their patient population. SUMMARY: A clear distinction between critical results and significantly abnormal results is essential for effective and timely healthcare interventions. Implementation of a policy using differentiated thresholds taking into account individual patient characteristics and how fast medical attention is needed, and the use alternative communication methods could enhance communication efficiency and reduce notification fatigue.

2.
Am J Kidney Dis ; 84(4): 427-436.e1, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38796137

RESUMEN

RATIONALE & OBJECTIVE: Kidneys are vital for vitamin D metabolism, and disruptions in both production and catabolism occur in chronic kidney disease. Although vitamin D activation occurs in numerous tissues, the kidneys are the most relevant source of circulating active vitamin D. This study investigates extrarenal vitamin D activation and the impact of kidney transplantation on vitamin D metabolism in patients who are anephric. STUDY DESIGN: Case series. SETTING & PARTICIPANTS: Adult patients with previous bilateral nephrectomy (anephric) not receiving active vitamin D therapy evaluated at the time of (N=38) and 1 year after (n=25) kidney transplantation. ANALYTICAL APPROACH: Chromatography with tandem mass spectrometry was used to measure vitamin D metabolites. Activity of CYP24A1 [24,25(OH)2D/25(OH)D] and CYP27B1 [1α,25(OH)2D/25(OH)D] is expressed as metabolic ratios. Differences between time points were evaluated by paired t-test or Wilcoxon matched-pairs signed-rank test. RESULTS: At time of transplantation, 1α,25(OH)2D was detectable in all patients (4-36pg/mL). There was a linear relationship between 25(OH)D and 1α,25(OH)2D levels (r=0.58, P<0.001), with 25(OH)D explaining 34% of the variation in 1α,25(OH)2D levels. There were no associations between 1α,25(OH)2D and biointact parathyroid hormone (PTH) or fibroblast growth factor 23 (FGF-23). One year after transplantation, 1α,25(OH)2D levels recovered (+205%), and CYP27B1 activity increased (+352%). Measures of vitamin D catabolism, 24,25(OH)2D and CYP24A1 activity increased 3- to 5-fold. Also, at 12 months after transplantation, 1α,25(OH)2D was positively correlated with PTH (ρ=0.603, P=0.04) but not with levels of 25(OH)D or FGF-23. LIMITATIONS: Retrospective, observational study design with a small cohort size. CONCLUSIONS: Low-normal levels of 1α,25(OH)2D was demonstrated in anephric patients, indicating production outside the kidneys. This extrarenal CYP27B1 activity may be more substrate driven than hormonally regulated. Kidney transplantation seems to restore kidney CYP27B1 and CYP24A1 activity, as evaluated by vitamin D metabolic ratios, resulting in both increased vitamin D production and catabolism. These findings may have implications for vitamin D supplementation strategies in the setting of kidney failure and transplantation. PLAIN-LANGUAGE SUMMARY: Vitamin D activation occurs in multiple tissues, but the kidneys are considered the only relevant source of circulating levels. This study investigates vitamin D activation outside the kidneys by measuring vitamin D metabolites in 38 patients without kidneys. Active vitamin D was detectable in all patients, indicating production outside of the kidneys. There was a strong relationship between active and precursor vitamin D levels, but no association with mineral metabolism hormones, indicating that vitamin D production was more substrate dependent than hormonally regulated. One year after kidney transplantation, active vitamin D levels increased 2-fold and breakdown products increased 3-fold, indicating that production and degradation of the hormone recovers after kidney transplantation. These findings are relevant for future research into vitamin D supplementation in kidney failure.


Asunto(s)
25-Hidroxivitamina D3 1-alfa-Hidroxilasa , Factor-23 de Crecimiento de Fibroblastos , Trasplante de Riñón , Vitamina D3 24-Hidroxilasa , Vitamina D , Humanos , Masculino , Femenino , Vitamina D/sangre , Vitamina D/metabolismo , Vitamina D/análogos & derivados , Persona de Mediana Edad , 25-Hidroxivitamina D3 1-alfa-Hidroxilasa/metabolismo , Vitamina D3 24-Hidroxilasa/metabolismo , Adulto , Factores de Crecimiento de Fibroblastos/sangre , Factores de Crecimiento de Fibroblastos/metabolismo , Anciano , Nefrectomía , Periodo Preoperatorio , Estudios Retrospectivos
3.
Clin Chem Lab Med ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38747408

RESUMEN

High quality laboratory results are critical for patient management. However, poor sample quality can impact these results and patient safety. To ensure reliable and accurate results laboratories must be aware of each analyte's stability under various storage conditions and matrices to guarantee correct and dependable outcomes. This knowledge allows laboratories to define the allowable delay between sample collection and centrifugation/analysis for all analytes to guarantee appropriate results quality and interpretation. The EFLM WG-PRE therefore established a 4-step plan to tackle this issue, aiming to standardize and harmonize stability studies for improved comparison and meta-analysis. The plan included the development of checklists and how-to guides for performing and reporting stability studies as well as a central resource of stability data. This manuscript deals with the issue of evaluating publications and incorporating them into a central resource. To evaluate stability studies, the CRESS checklist was used to structure 20 sections used to judge the quality of studies. Each section has 4 levels of quality, with scores converted to numerical values and weighted based on expert opinion. Based on this, a final score ranging from A to D was determined. The procedure was then tested on six manuscripts and checked for agreement between expert judgements. The results demonstrated that the proposed evaluation process is a useful tool to distinguish between best in class manuscripts and those of lower quality. The EFLM WG-PRE strongly believes that the provided recommendations and checklists will help improving stability studies both in quality and standardisation.

4.
Clin Chem Lab Med ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39072394

RESUMEN

OBJECTIVES: Stability of concentrations of urinary stone-related metabolites was analyzed from samples of recurrent urinary stone formers to assess necessity and effectiveness of urine acidification during collection and storage. METHODS: First-morning urine was collected from 20 adult calcium-stone forming patients at Tomas Bata Hospital in the Czech Republic. Urine samples were analyzed for calcium, magnesium, inorganic phosphate, uric acid, sodium, potassium, chloride, citrate, oxalate, and urine particles. The single-voided specimens were collected without acidification, after which they were divided into three groups for storage: samples without acidification ("NON"), acidification before storage ("PRE"), or acidification after storage ("POST"). The analyses were conducted on the day of arrival (day 0, "baseline"), or after storage for 2 or 7 days at room temperature. The maximum permissible difference (MPD) was defined as ±20 % from the baseline. RESULTS: The urine concentrations of all stone-related metabolites remained within the 20 % MPD limits in NON and POST samples after 2 days, except for calcium in NON sample of one patient, and oxalate of three patients and citrate of one patient in POST samples. In PRE samples, stability failed in urine samples for oxalate of three patients, and for uric acid of four patients after 2 days. Failures in stability often correlated with high baseline concentrations of those metabolites in urine. CONCLUSIONS: Detailed procedures are needed to collect urine specimens for analysis of urinary stone-related metabolites, considering both patient safety and stability of those metabolites. We recommend specific preservation steps.

5.
Clin Chem Lab Med ; 62(8): 1538-1547, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38581294

RESUMEN

AIM: Blood Sampling Guidelines have been developed to target European emergency medicine-related professionals involved in the blood sampling process (e.g. physicians, nurses, phlebotomists working in the ED), as well as laboratory physicians and other related professionals. The guidelines population focus on adult patients. The development of these blood sampling guidelines for the ED setting is based on the collaboration of three European scientific societies that have a role to play in the preanalytical phase process: EuSEN, EFLM, and EUSEM. The elaboration of the questions was done using the PICO procedure, literature search and appraisal was based on the GRADE methodology. The final recommendations were reviewed by an international multidisciplinary external review group. RESULTS: The document includes the elaborated recommendations for the selected sixteen questions. Three in pre-sampling, eight regarding sampling, three post-sampling, and two focus on quality assurance. In general, the quality of the evidence is very low, and the strength of the recommendation in all the questions has been rated as weak. The working group in four questions elaborate the recommendations, based mainly on group experience, rating as good practice. CONCLUSIONS: The multidisciplinary working group was considered one of the major contributors to this guideline. The lack of quality information highlights the need for research in this area of the patient care process. The peculiarities of the emergency medical areas need specific considerations to minimise the possibility of errors in the preanalytical phase.


Asunto(s)
Recolección de Muestras de Sangre , Servicio de Urgencia en Hospital , Humanos , Recolección de Muestras de Sangre/normas , Recolección de Muestras de Sangre/métodos , Medicina de Emergencia/normas , Fase Preanalítica/normas , Europa (Continente) , Sociedades Médicas , Química Clínica/normas , Química Clínica/métodos
6.
Clin Chem Lab Med ; 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39259894

RESUMEN

The ultimate goal of value-based laboratory medicine is maximizing the effectiveness of laboratory tests in improving patient outcomes, optimizing resources and minimizing unnecessary costs. This approach abandons the oversimplified notion of test volume and cost, in favor of emphasizing the clinical utility and quality of diagnostic tests in the clinical decision-making. Several key elements characterize value-based laboratory medicine, which can be summarized in some basic concepts, such as organization of in vitro diagnostics (including appropriateness, integrated diagnostics, networking, remote patient monitoring, disruptive innovations), translation of laboratory data into clinical information and measurable outcomes, sustainability, reimbursement, ethics (e.g., patient empowerment and safety, data protection, analysis of big data, scientific publishing). Education and training are also crucial, along with considerations for the future of the profession, which will be largely influenced by advances in automation, information technology, artificial intelligence, and regulations concerning in vitro diagnostics. This collective opinion paper, composed of summaries from presentations given at the two-day European Federation of Laboratory Medicine (EFLM) Strategic Conference "A vision to the future: value-based laboratory medicine" (Padova, Italy; September 23-24, 2024), aims to provide a comprehensive overview of value-based laboratory medicine, projecting the profession into a more clinically effective and sustainable future.

7.
J Med Virol ; 95(4): e28736, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-37185854

RESUMEN

Rates and modulators of SARS-CoV-2 vaccine nonresponse and breakthrough infections remain unclear in serially vaccinated transplant recipients. In a prospective, mono-centric, observational study, 1878 adult solid organ and hematopoietic cell transplant recipients, with prior SARS-CoV-2 vaccination, were included between March 2021 and February 2022. SARS-CoV-2 anti-spike IgG antibodies were measured at inclusion and details on SARS-CoV-2 vaccine doses and infection were collected. No life-threatening adverse events were reported after a total of 4039 vaccine doses. In transplant recipients without prior SARS-CoV-2 infection (n = 1636), antibody response rates ranged widely, from 47% in lung transplant to 90% in liver transplant and 91% in hematopoietic cell transplant recipients after third vaccine dose. Antibody positivity rate and levels increased after each vaccine dose in all types of transplant recipients. In multivariable analysis, older age, chronic kidney disease and daily dose of mycophenolate and corticosteroids were negatively associated with antibody response rate. Overall rate of breakthrough infections was 25.2% and mainly (90.2%) occurred after third and fourth vaccine dose. Lung transplant recipients had the highest rates of severe breakthrough infection (10.5%) and death (2.5%). In multivariable analysis, older age, daily dose of mycophenolate and corticosteroids were associated with severe breakthrough infection. Transplant recipients with infection before first vaccine dose (n = 160) had higher antibody response rates and levels after each vaccine dose, and a significantly lower overall rate of breakthrough infections compared to those without prior infection. Antibody response after SARS-CoV-2 vaccination and rate of severe breakthrough infections vary largely between different transplant types and are modulated by specific risk factors. The observed heterogeneity supports a tailored approach against COVID-19 in transplant recipients.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Trasplante de Células Madre Hematopoyéticas , Adulto , Humanos , Anticuerpos Antivirales , Formación de Anticuerpos , Infección Irruptiva , COVID-19/prevención & control , Vacunas contra la COVID-19/administración & dosificación , Inmunoglobulina G , Inmunosupresores/efectos adversos , Estudios Prospectivos , SARS-CoV-2 , Receptores de Trasplantes
8.
Clin Chem Lab Med ; 61(4): 580-586, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36539928

RESUMEN

Among medical specialties, laboratory medicine is the largest producer of structured data and must play a crucial role for the efficient and safe implementation of big data and artificial intelligence in healthcare. The area of personalized therapies and precision medicine has now arrived, with huge data sets not only used for experimental and research approaches, but also in the "real world". Analysis of real world data requires development of legal, procedural and technical infrastructure. The integration of all clinical data sets for any given patient is important and necessary in order to develop a patient-centered treatment approach. Data-driven research comes with its own challenges and solutions. The Findability, Accessibility, Interoperability, and Reusability (FAIR) Guiding Principles provide guidelines to make data findable, accessible, interoperable and reusable to the research community. Federated learning, standards and ontologies are useful to improve robustness of artificial intelligence algorithms working on big data and to increase trust in these algorithms. When dealing with big data, the univariate statistical approach changes to multivariate statistical methods significantly shifting the potential of big data. Combining multiple omics gives previously unsuspected information and provides understanding of scientific questions, an approach which is also called the systems biology approach. Big data and artificial intelligence also offer opportunities for laboratories and the In Vitro Diagnostic industry to optimize the productivity of the laboratory, the quality of laboratory results and ultimately patient outcomes, through tools such as predictive maintenance and "moving average" based on the aggregate of patient results.


Asunto(s)
Inteligencia Artificial , Macrodatos , Humanos , Algoritmos , Atención a la Salud , Medicina de Precisión/métodos
9.
Clin Chem Lab Med ; 61(10): 1708-1718, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37021544

RESUMEN

OBJECTIVES: Knowledge of the stability of analytes in clinical specimens is a prerequisite for proper transport and preservation of samples to avoid laboratory errors. The new version of ISO 15189:2022 and the European directive 2017/746 increase the requirements on this topic for manufacturers and laboratories. Within the project to generate a stability database of European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group Preanalytical Phase (WG-PRE), the need to standardise and improve the quality of published stability studies has been detected, being a manifest deficit the absence of international guidelines for the performance of stability studies on clinical specimens. METHODS: These recommendations have been developed and summarised by consensus of the WG-PRE and are intended primarily to improve the quality of sample stability claims included in information for users provided by assay supplier companies, according to the requirements of the new European regulations and standards for accreditation. RESULTS: This document provides general recommendations for the performance of stability studies, oriented to the estimation of instability equations in the usual working conditions, allowing flexible adaptation of the maximum permissible error specifications to obtain stability limits adapted to the intended use. CONCLUSIONS: We present this recommendation based on the opinions of the EFLM WG-PRE group for the standardisation and improvement of stability studies, with the intention to improve the quality of the studies and the transferability of their results to laboratories.


Asunto(s)
Química Clínica , Fase Preanalítica , Humanos , Laboratorios , Estándares de Referencia , Acreditación
10.
Pediatr Nephrol ; 38(9): 3043-3053, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36939917

RESUMEN

BACKGROUND: Young autosomal dominant polycystic kidney disease (ADPKD) patients are becoming the new target population for the development of new treatment options. Determination of a reliable equation for estimated glomerular filtration rate (eGFR) from early stages is needed with the promising potential interventional therapies. METHODS: Prospective and longitudinal study on a cohort of 68 genotyped ADPKD patients (age range 0-23 years) with long-term follow-up. Commonly used equations for eGFR were compared for their relative performance. RESULTS: The revised Schwartz formula (CKiD) showed a highly significant decline in eGFR with aging (- 3.31 mL/min/1.73 m2/year, P < 0.0001). The recently updated equation by the Schwartz group (CKiDU25) showed a smaller (- 0.90 mL/min/1.73 m2/year) but significant (P = 0.001) decline in eGFR with aging and also showed a significant sex difference (P < 0.0001), not observed by the other equations. In contrast, the full age spectrum (FAS) equations (FAS-SCr, FAS-CysC, and the combined) showed no age and sex dependency. The prevalence of hyperfiltration is highly dependent on the formula used, and the highest prevalence was observed with the CKiD Equation (35%). CONCLUSIONS: The most widely used methods to calculate eGFR in ADPKD children (CKiD and CKiDU25 equations) were associated with unexpected age or sex differences. The FAS equations were age- and sex-independent in our cohort. Hence, the switch from the CKiD to CKD-EPI equation at the transition from pediatric to adult care causes implausible jumps in eGFR, which could be misinterpreted. Having reliable methods to calculate eGFR is indispensable for clinical follow-up and clinical trials. A higher resolution version of the Graphical abstract is available as Supplementary information.


Asunto(s)
Riñón Poliquístico Autosómico Dominante , Insuficiencia Renal Crónica , Transición a la Atención de Adultos , Humanos , Niño , Femenino , Masculino , Adulto Joven , Recién Nacido , Lactante , Preescolar , Adolescente , Adulto , Tasa de Filtración Glomerular , Riñón Poliquístico Autosómico Dominante/diagnóstico , Riñón Poliquístico Autosómico Dominante/genética , Estudios Longitudinales , Estudios Prospectivos , Creatinina
11.
Am J Hum Genet ; 104(5): 835-846, 2019 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-30982613

RESUMEN

Phosphoglucomutase 1 (PGM1) encodes the metabolic enzyme that interconverts glucose-6-P and glucose-1-P. Mutations in PGM1 cause impairment in glycogen metabolism and glycosylation, the latter manifesting as a congenital disorder of glycosylation (CDG). This unique metabolic defect leads to abnormal N-glycan synthesis in the endoplasmic reticulum (ER) and the Golgi apparatus (GA). On the basis of the decreased galactosylation in glycan chains, galactose was administered to individuals with PGM1-CDG and was shown to markedly reverse most disease-related laboratory abnormalities. The disease and treatment mechanisms, however, have remained largely elusive. Here, we confirm the clinical benefit of galactose supplementation in PGM1-CDG-affected individuals and obtain significant insights into the functional and biochemical regulation of glycosylation. We report here that, by using tracer-based metabolomics, we found that galactose treatment of PGM1-CDG fibroblasts metabolically re-wires their sugar metabolism, and as such replenishes the depleted levels of galactose-1-P, as well as the levels of UDP-glucose and UDP-galactose, the nucleotide sugars that are required for ER- and GA-linked glycosylation, respectively. To this end, we further show that the galactose in UDP-galactose is incorporated into mature, de novo glycans. Our results also allude to the potential of monosaccharide therapy for several other CDG.


Asunto(s)
Trastornos Congénitos de Glicosilación/metabolismo , Fibroblastos/metabolismo , Galactosa/administración & dosificación , Fosfoglucomutasa/deficiencia , Uridina Difosfato Galactosa/metabolismo , Uridina Difosfato Glucosa/metabolismo , Células Cultivadas , Estudios de Cohortes , Trastornos Congénitos de Glicosilación/tratamiento farmacológico , Trastornos Congénitos de Glicosilación/patología , Fibroblastos/efectos de los fármacos , Fibroblastos/patología , Glicosilación , Humanos
12.
J Inherit Metab Dis ; 45(6): 1151-1162, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36053909

RESUMEN

Porphyrias are rare metabolic disorders of the haem synthesis. They can present with acute neurovisceral attacks, cutaneous symptoms, or a combination of both. As they present with a wide variety of clinical symptoms, diagnosis is often delayed and correct interpretation of porphyria-related tests remains a challenge for many physicians. We developed and validated two algorithms for the laboratory diagnosis of porphyrias based on presenting symptoms. Based on a literature search and clinical/laboratory expertise, we developed algorithms for acute and cutaneous porphyrias. We validated these algorithms using all porphyria related laboratory test requests between January 1st 2000 and September 30th 2020 in UZ Leuven. In addition, we also evaluated our algorithm using samples from the European porphyria network (EPNET) external quality assessment scheme (2010-2021). Sensitivity of the algorithm for acute porphyria was 100.0% [74.9%-100.0%] (13 acute intermittent porphyria (AIP) and 1 variegate porphyria [VP]) with a specificity of 98.5% [91.0%-100.0%] (65 patients). Sensitivity of the algorithm for cutaneous porphyria was 100% [95.1%-100.0%] (7 VP, 59 porphyria cutanea tarda (PCT), 23 erythropoietic protoporphyria (EPP), 2 X-linked erythropoietic protoporphyria [XLEPP]) with a specificity of 93.9% [82.9%-98.5%]. There were no diagnostic samples of other types of porphyria. The algorithms correctly identified 18 of the 19 EPNET porphyria cases. One of the two hereditary coproporphyria cases was missed. The algorithms for acute and cutaneous porphyria showed high sensitivity and specificity and can be used to aid the clinician in correctly interpreting the laboratory findings of porphyria-related tests.


Asunto(s)
Porfiria Intermitente Aguda , Porfirias Hepáticas , Porfirias , Protoporfiria Eritropoyética , Humanos , Porfirias/diagnóstico , Técnicas de Laboratorio Clínico , Algoritmos
13.
Clin Chem Lab Med ; 60(9): 1356-1364, 2022 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-35696446

RESUMEN

OBJECTIVES: Although laboratory result presentation may lead to information overload and subsequent missed or delayed diagnosis, little has been done in the past to improve this post-analytical issue. We aimed to investigate the efficiency, efficacy and user satisfaction of alternative report formats. METHODS: We redesigned cumulative (sparkline format) and single reports (improved tabular and z-log format) and tested these on 46 physicians, nurses and medical students in comparison to the classical tabular formats, by asking standardized questions on general items on the reports as well as on suspected diagnosis and follow-up treatment or diagnostics. RESULTS: Efficacy remained at a very high level both in the new formats as well as in the classical formats. We found no significant difference in any of the groups. Efficiency improved in all groups when using the sparkline cumulative format and marginally when showing the improved tabular format. When asking medical questions, efficiency and efficacy remained similar between report formats and groups. All alternative reports were subjectively more attractive to the majority of participants. CONCLUSIONS: Showing cumulative reports as a graphical display led to faster detection of general information on the report with the same level of correctness. Considering the familiarity bias of the classical single report formats, the borderline-significant improvement of the alternative tabular format and the non-inferiority of the z-log format, suggests that single reports might benefit from some improvements derived from basic information design.


Asunto(s)
Química Clínica , Satisfacción Personal , Humanos , Laboratorios , Informe de Investigación
14.
Artif Organs ; 46(2): 246-258, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34633676

RESUMEN

BACKGROUND: There is a continued interest in ex situ heart perfusion as an alternative strategy for donor heart preservation. We hypothesize that oxygenated machine perfusion of donor hearts at a temperature that avoids both normothermia and deep hypothermia offers adequate and safe preservation. METHODS: Cardioplegia-arrested porcine donor hearts were randomly assigned to six hours of preservation using cold storage (CS, n = 5) or machine perfusion using an oxygenated acellular perfusate at 21°C (MP, n = 5). Subsequently, all grafts were evaluated using the Langendorff method for 120 min. Metabolic parameters and histology were analyzed. Systolic function was assessed by contractility and elastance. Diastolic function was assessed by lusitropy and stiffness. RESULTS: For both groups, in vivo baseline and post-Langendorff biopsies were comparable, as were lactate difference and myocardial oxygen consumption. Injury markers gradually increased and were comparable. Significant weight gain was seen in MP (p = 0.008). Diastolic function was not impaired in MP, and lusitropy was superior from 30 min up to 90 min of reperfusion. Contractility was superior in MP during the first hour of evaluation. CONCLUSION: We conclude that the initial functional outcome of MP-preserved hearts was transiently superior compared to CS, with no histological injury post-Langendorff. Our machine perfusion strategy could offer feasible and safe storage of hearts prior to transplantation. Future studies are warranted for further optimization.


Asunto(s)
Trasplante de Corazón , Corazón/fisiología , Preservación de Órganos/métodos , Animales , Frío , Femenino , Paro Cardíaco Inducido , Ácido Láctico/metabolismo , Preservación de Órganos/instrumentación , Oxígeno/metabolismo , Perfusión/métodos , Porcinos
15.
J Clin Microbiol ; 59(7): e0037421, 2021 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-33849953

RESUMEN

We evaluated the quantitative DiaSorin Liaison severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen test in symptomatic and asymptomatic individuals consulting their general practitioners (GPs) during a period of stable intense virus circulation (213/100,000 habitants per day). Leftover reverse transcription-PCR (RT-PCR) positive (n = 204) and negative (n = 210) nasopharyngeal samples were randomly selected among fresh routine samples collected from patients consulting their GPs. Samples were tested on Liaison XL according to the manufacturer's instructions. Equivocal results were considered negative. The overall sensitivity and specificity of the Liaison antigen test compared to RT-PCR were 65.7% (95% confidence interval [CI], 58.9% to 71.9%) and 100% (CI, 97.8% to 100%). Sensitivity in samples with viral loads of ≥105, ≥104, and ≥103 copies/ml were 100% (CI, 96.3% to 100.0%), 96.5% (CI, 91.8% to 98.7%), and 87.4% (CI, 81.3% to 91.5%), respectively. All samples with ≤103 copies/ml were antigen negative. The ratio of antigen concentration to viral load in samples with ≥103 copies/ml was comparable in symptomatic and asymptomatic individuals (P = 0.58). The proportion of RT-PCR-positive participants with a high viral load (≥105 copies/ml) was not significantly higher in symptomatic than in asymptomatic participants (63.9% [CI, 54.9% to 72.0%] versus 51.9% [CI, 41.1% to 62.6%]; P = 0.11), but the proportion of participants with a low viral load (<103 copies/ml) was significantly higher in asymptomatic than in symptomatic RT-PCR-positive participants (35.4% [CI, 25.8% to 46.4%] versus 14.3% [CI, 9.0% to 21.8%]; P < 0.01). Sensitivity and specificity in samples with a viral load of ≥104 copies/ml were 96.5% and 100%. The correlation of antigen concentration with viral load was comparable in symptomatic and asymptomatic individuals.


Asunto(s)
COVID-19 , Humanos , Pacientes Ambulatorios , Reacción en Cadena en Tiempo Real de la Polimerasa , Transcripción Reversa , SARS-CoV-2 , Sensibilidad y Especificidad , Carga Viral
16.
Electrophoresis ; 42(4): 402-428, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33280143

RESUMEN

The presence of a dynamic and balanced equilibrium between the production of reactive oxygen (ROS) and nitrogen (RNS) species and the in-house antioxidant defense mechanisms is characteristic for a healthy body. During oxidative stress (OS), this balance is switched to increased production of ROS and RNS, exceeding the capacity of physiological antioxidant systems. This can cause damage to biological molecules, leading to loss of function and even cell death. Nowadays, there is increasing scientific and clinical interest in OS and the associated parameters to measure the degree of OS in biofluids. An increasing number of reports using LC-MS/MS methods for the analysis of OS biomarkers can be found. Since bioanalysis is usually complicated by matrix effects, various types of cleanup procedures are used to effectively separate the biomarkers from the matrix. This is an essential part of the analysis to prepare a reproducible and homogenous solution suitable for injection onto the column. The present review gives a summary of the chromatographic methods used for the determination of OS biomarkers in both urine and plasma, serum, and whole blood samples. The first part mainly describes the biological background of the different OS biomarkers, while the second part reports examples of chromatographic methods for the analysis of different metabolites connected with OS in biofluids, covering a period from 2015 till early 2020. The selected examples mainly include LC-MS/MS methods for isoprostanes, oxidized proteins, oxidized lipoproteins, and DNA/RNA biomarkers. The last part explains the clinical relevance of this review.


Asunto(s)
Biomarcadores , Cromatografía Liquida , Estrés Oxidativo/fisiología , Espectrometría de Masas en Tándem , Biomarcadores/sangre , Biomarcadores/orina , Humanos , Peroxidación de Lípido/fisiología , Lipoproteínas LDL/sangre
17.
Clin Chem Lab Med ; 59(6): 1047-1061, 2021 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-33554545

RESUMEN

The International Organization for Standardization (ISO) 15189:2012 standard aims to improve quality in medical laboratories through standardization of all key elements in the total testing process, including the pre-analytical phase. It is hence essential that accreditation bodies, assessing laboratories against ISO15189:2012, pay sufficient attention to auditing pre-analytical activities. However, there are significant differences in how technical auditors interpret the pre-analytical requirements described in ISO15189:2012. In this consensus document, the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Pre-analytical Phase (WG-PRE) sets out to review pre-analytical requirements contained in ISO15189:2012 and provide guidance for laboratories on how to meet these requirements. The target audience for this consensus document is laboratory professionals who wish to improve the quality of the pre-analytical phase in their laboratory. For each of the ISO requirements described in ISO15189:2012, members of EFLM WG-PRE agreed by consensus on minimal recommendations and best-in-class solutions. The minimal consensus recommendation was defined as the minimal specification which laboratories should implement in their quality management system to adequately address the pre-analytical requirement described in ISO15189:2012. The best-in-class solution describes the current state-of-the-art in fulfilling a particular pre-analytical requirement in ISO15189:2012. We fully acknowledge that not every laboratory has the means to implement these best-in-class solutions, but we hope to challenge laboratories in critically evaluating and improving their current procedures by providing this expanded guidance.


Asunto(s)
Servicios de Laboratorio Clínico , Laboratorios Clínicos , Química Clínica , Técnicas de Laboratorio Clínico , Consenso , Humanos
18.
Mycoses ; 64(9): 1111-1116, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33963620

RESUMEN

BACKGROUND: Isavuconazole is a triazole antifungal drug, approved for the treatment of invasive aspergillosis and mucormycosis. Isavuconazole is metabolised by CYP3A4 and CYP3A5, and it has been shown that the CYP3A inducer rifampin reduces isavuconazole exposure. By extrapolation, the concomitant use of isavuconazole with moderate and strong CYP450 inducers is contraindicated, although it is known that some CYP450 inducers are less potent in comparison with rifampin. OBJECTIVES: We aim to document exposure to isavuconazole in patients concomitantly treated with a CYP450 inducer that is less potent compared to rifampin. Moreover, although it is well known that CYP3A enzymes are important for the metabolism of isavuconazole, this induction effect has never been studied in combination with the patient's CYP3A genotype. PATIENTS: We report three patients treated with both isavuconazole and a CYP3A inducer that is less potent compared to rifampin (rifabutin or phenobarbital), in whom we determined isavuconazole concentrations. RESULTS: These cases suggest that the CYP3A4/5 genotype is an important determinant for isavuconazole exposure and that it might also influence the CYP450 induction interaction. CONCLUSIONS: CYP3A inducers that are less potent compared to rifampin, may be combined with isavuconazole in patients with loss of CYP3A5 activity (CYP3A5*3/*3). Therapeutic drug monitoring is recommended during this combination. However, low-isavuconazole exposure was observed in the extensive metaboliser with CYP3A4*1/*1 and CYP3A5*1/*3 alleles.


Asunto(s)
Inductores del Citocromo P-450 CYP3A , Nitrilos , Farmacogenética , Piridinas , Triazoles , Alelos , Citocromo P-450 CYP3A/genética , Inductores del Citocromo P-450 CYP3A/farmacocinética , Inductores del Citocromo P-450 CYP3A/uso terapéutico , Genotipo , Humanos , Nitrilos/farmacocinética , Nitrilos/uso terapéutico , Piridinas/farmacocinética , Piridinas/uso terapéutico , Rifampin , Triazoles/farmacocinética , Triazoles/uso terapéutico
19.
Ophthalmic Plast Reconstr Surg ; 37(3S): S162-S164, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32991495

RESUMEN

Amid the global coronavirus disease 2019 (COVID-19) outbreak, an 89-year-old male with chronic kidney disease presented with acute dacryocystitis and a persistent dry cough. After a course of antibiotics, external dacryocystorhinostomy was performed under local anesthesia without sedation. During planned hemodialysis in the early hours after the procedure, the patient developed nausea and hematemesis followed by severe dyspnea and hypoxemia. The patient was diagnosed with aspiration pneumonia, a previously unreported complication in lacrimal surgery.


Asunto(s)
COVID-19 , Dacriocistitis , Dacriocistorrinostomía , Neumonía por Aspiración , Anciano de 80 o más Años , Anestesia Local/efectos adversos , Dacriocistitis/diagnóstico , Dacriocistitis/etiología , Dacriocistitis/cirugía , Humanos , Masculino , SARS-CoV-2
20.
Clin Chem Lab Med ; 59(1): 101-106, 2020 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-32692695

RESUMEN

Objectives: The new European In Vitro Diagnostic (IVD) Regulation 2017/746 (IVDR) restricts the use of lab-developed tests (LDT) after 26th May 2022. There are no data on the impact of the IVDR on laboratories in the European Union. Methods: Laboratory tests performed in UZ Leuven were divided in four groups: core laboratory, immunology, special chemistry, and molecular microbiology testing. Each test was classified as Conformité Européenne (CE)-IVD, modified/off-label CE-IVD, commercial Research Use Only (RUO) or LDT. Each matrix was considered a separate test. Results: We found that 97.6% of the more than 11.5 million results/year were generated with a CE-IVD method. Of the 922 different laboratory tests, however, only 41.8% were CE-IVD, 10.8% modified/off-label CE-IVD, 0.3% RUO, and 47.1% LDT. Off-label CE-IVD was mainly used to test alternative matrices not covered by the claim of the manufacturer (e.g., pleural or peritoneal fluid). LDTs were mainly used for special chemistry, flow cytometry, and molecular testing. Excluding flow cytometry, the main reasons for the use of 377 LDTs were lack of a CE-IVD method (71.9%), analytical requirements (14.3%), and the fact the LDT was in use before CE-IVD available (11.9%). Conclusions: While the large majority of results (97.6%) were generated with a CE-IVD method, only 41.8% of laboratory tests were CE-IVD. There is currently no alternative on the market for 71.5% of the 537 LDTs performed in our laboratory which do not fall within the scope of the current IVD directive (IVDD). Compliance with the IVDR will require a major investment of time and effort.


Asunto(s)
Hospitales Universitarios/normas , Laboratorios de Hospital/normas , Juego de Reactivos para Diagnóstico/normas , Bélgica , Técnicas de Química Analítica/normas , Técnicas de Química Analítica/estadística & datos numéricos , Hospitales Universitarios/legislación & jurisprudencia , Hospitales Universitarios/estadística & datos numéricos , Humanos , Pruebas Inmunológicas/normas , Pruebas Inmunológicas/estadística & datos numéricos , Laboratorios de Hospital/legislación & jurisprudencia , Laboratorios de Hospital/estadística & datos numéricos , Técnicas Microbiológicas/normas , Técnicas Microbiológicas/estadística & datos numéricos , Juego de Reactivos para Diagnóstico/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA