Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Diabetologia ; 65(12): 2044-2055, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36102938

RESUMEN

AIMS/HYPOTHESIS: Cancer has contributed to an increasing proportion of diabetes-related deaths, while lifestyle management is the cornerstone of both diabetes care and cancer prevention. We aimed to evaluate the associations of combined healthy lifestyles with total and site-specific cancer risks among individuals with diabetes. METHODS: We included 92,239 individuals with diabetes but without cancer at baseline from five population-based cohorts in the USA (National Health and Nutrition Examination Survey and National Institutes of Health [NIH]-AARP Diet and Health Study), the UK (UK Biobank study) and China (Dongfeng-Tongji cohort and Kailuan study). Healthy lifestyle scores (range 0-5) were constructed based on current nonsmoking, low-to-moderate alcohol drinking, adequate physical activity, healthy diet and optimal bodyweight. Cox regressions were used to calculate HRs for cancer morbidity and mortality, adjusting for sociodemographic, medical and diabetes-related factors. RESULTS: During 376,354 person-years of follow-up from UK Biobank and the two Chinese cohorts, 3229 incident cancer cases were documented, and 6682 cancer deaths were documented during 1,089,987 person-years of follow-up in the five cohorts. The pooled multivariable-adjusted HRs (95% CIs) comparing participants with 4-5 vs 0-1 healthy lifestyle factors were 0.73 (0.61, 0.88) for incident cancer and 0.55 (0.46, 0.67) for cancer mortality, and ranged between 0.41 and 0.63 for oesophagus, lung, liver, colorectum, breast and kidney cancers. Findings remained consistent across different cohorts and subgroups. CONCLUSIONS/INTERPRETATION: This international cohort study found that adherence to combined healthy lifestyles was associated with lower risks of total cancer morbidity and mortality as well as several subtypes (oesophagus, lung, liver, colorectum, breast and kidney cancers) among individuals with diabetes.


Asunto(s)
Diabetes Mellitus , Neoplasias Renales , Humanos , Estudios de Cohortes , Encuestas Nutricionales , Estudios Prospectivos , Estilo de Vida Saludable , Morbilidad , China/epidemiología , Reino Unido/epidemiología , Factores de Riesgo
2.
Environ Res ; 172: 665-674, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30878738

RESUMEN

Blood trihalomethanes (THMs) and urinary haloacetic acids (HAAs) are the leading candidate biomarkers for disinfection byproduct (DBP) exposure. However, no studies have assessed the exposure profiles, temporal variability, and potential predictors of these biomarkers during pregnancy. Here we collected blood (n = 4304) and urine samples (n = 4165) from 1760 Chinese pregnant women during early, mid-, and late pregnancy, which were separately analyzed for 4 THMs and 2 HAAs. We calculated the intraclass correlation coefficients (ICCs) to assess the variability of these biomarkers and estimated their correlations with sociodemographic, water-use behavioral, dietary and sample collection factors using mixed models. The median concentrations of TCM, BDCM, Br-THMs [sum of BDCM, dibromochloromethane (DBCM), bromoform (TBM)], total THMs (TTHMs, sum of TCM and Br-THMs), DCAA and TCAA in the water distribution system were 4.2 µg/L, 1.7 µg/L, 2.9 µg/L, 7.1 µg/L, 3.4 µg/L and 8.2 µg/L, respectively. Chloroform (TCM), bromodichloromethane (BDCM), dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) were detected in > 75% of the biospecimens. Repeated measurements of blood TCM, BDCM, Br-THMs and TTHMs and urinary DCAA and TCAA uniformly exhibited high variability (ICCs = 0.01-0.13); the use of a single measurement to classify gestational average exposure resulted in a high degree of exposure misclassification. The sampling season was a strong predictor of all analyzed DBPs. Additionally, we detected a positive association of blood TCM and BDCM with household income, urinary DCAA with age, and urinary TCAA with tap water usage, education level and amount of tap water consumed. Inverse associations were found between blood BDCM and vegetable consumption, and between blood Br-THM and TTHM and time interval since the last bathing/showering. Afternoon samples had lower DCAA concentrations than did early morning samples. Our results indicate that blood THM and urinary HAA concentrations vary greatly over the course of pregnancy and are affected by sampling season, time of day of blood/urine collection, sociodemographic factors, recent water-use activities and dietary intake.


Asunto(s)
Trihalometanos , Contaminantes Químicos del Agua , Biomarcadores/sangre , Biomarcadores/orina , China , Ácido Dicloroacético/orina , Exposición a Riesgos Ambientales/análisis , Exposición a Riesgos Ambientales/estadística & datos numéricos , Femenino , Humanos , Embarazo , Ácido Tricloroacético/orina , Trihalometanos/sangre , Contaminantes Químicos del Agua/sangre , Contaminantes Químicos del Agua/orina
4.
Mayo Clin Proc ; 98(1): 60-74, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36603958

RESUMEN

OBJECTIVE: To prospectively examine the associations of combined lifestyle factors with incident cardiovascular disease (CVD) and mortality in patients with diabetes. PATIENTS AND METHODS: Patients with prevalent diabetes were included from 5 prospective, population-based cohorts in China (Dongfeng-Tongji cohort and Kailuan study), the United Kingdom (UK Biobank study), and the United States (National Health and Nutrition Examination Survey and National Institutes of Health-AARP Diet and Health Study). Healthy lifestyle scores were constructed according to non-current smoking, low to moderate alcohol drinking, regular physical activity, healthy diet, and optimal body weight; the healthy level of each lifestyle factor was assigned 1 point, or 0 for otherwise, and the range of the score was 0 to 5. Cox proportional hazards models were used to estimate hazard ratios for incident CVD, CVD mortality, and all-cause mortality adjusting for sociodemographic, medical, and diabetes-related factors, and outcomes were obtained by linkage to medical records and death registries. Data were collected from October 18, 1988, to September 30, 2020. RESULTS: A total of 6945 incident CVD cases were documented in 41,350 participants without CVD at baseline from the 2 Chinese cohorts and the UK Biobank during 389,330 person-years of follow-up, and 40,353 deaths were documented in 101,219 participants from all 5 cohorts during 1,238,391 person-years of follow-up. Adjusted hazard ratios (95% CIs) comparing patients with 4 or 5 vs 0 or 1 healthy lifestyle factors were 0.67 (0.60 to 0.74) for incident CVD, 0.58 (0.50 to 0.68) for CVD mortality, and 0.60 (0.53 to 0.68) for all-cause mortality. Findings remained consistent across different cohorts, subgroups, and sensitivity analyses. CONCLUSION: The international analyses document that adherence to multicomponent healthy lifestyles is associated with lower risk of CVD and premature death of patients with diabetes.


Asunto(s)
Enfermedades Cardiovasculares , Diabetes Mellitus , Humanos , Estados Unidos/epidemiología , Factores de Riesgo , Estudios Prospectivos , Encuestas Nutricionales , Estilo de Vida Saludable , Diabetes Mellitus/epidemiología
5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(4): 1142-6, 2011 Apr.
Artículo en Zh | MEDLINE | ID: mdl-21714279

RESUMEN

The crater depth value of sample surface during sputtering is important analysis information for the depth profile analysis of glow discharge spectrometry. Real-time sputtered depth measurement with Laser triangulation measurement method for glow discharge compositional analysis, effectively solves the issues of incorrect depth value calculation and complicated procedures in traditional depth analysis method. This paper presents a new Grimm-type glow discharge source for real-time sputtering depth measurement by laser displacement sensor. This GD source also ensures fine sputtering effects and ideal resolution for multi-layer structure and interface. Optical fiber is used to transmit glow spectrum signal from GD-source to multi-channel photoelectric detection system. The design for the first time accomplishes the real-time signal collection and time-based synchronization analysis for both spectrum signal and sputtering depth signal. The real-time sputtering depth measurement curve of standard samples is obtained. The design and operating principle of this new-type GD-source is described in detail. Under the sputtering conditions of 30 mA, 900 V and 20 minutes, the sputtering rates of iron-based and copper-based sample sputtered by this GD source with good depth resolution are about 10 and 55 nm x s(-1). Surface topography picture of sputtering crater and microphotograph of metal samples are provided in the paper. Low-alloy steel standard sample is tested with this new GD source, the relative standard deviation (RSD) of C, Cu, Al, Ni, Mo, Mn and V elements are less than 1.7%, while for Cr and Si elements RSDs are less than 2.6%. The result data of the testing is provided in this paper.

6.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(3): 839-43, 2011 Mar.
Artículo en Zh | MEDLINE | ID: mdl-21595252

RESUMEN

There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.

7.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(9): 2536-41, 2011 Sep.
Artículo en Zh | MEDLINE | ID: mdl-22097866

RESUMEN

This paper presents the traditional methods of GD depth analysis method and also its limitations, and the earlier studies of real-time depth measurement technology. A new method of real-time depth determination by laser technology for GD-OES depth analysis is proposed. The real-time depth measurement system is composed of laser displacement sensor and new designed Grimm-type GD source based on laser measurement method, and the system design and technical principles are described in detail. Sputtering depth measurement signal and element spectrum signal can be synchronously collected by this system. The displacement phenomenon of glow discharge source during real-time sputtering depth measurement process is analyzed. The real-time sputtering depth measurement curve of zinc alloy standard sample was tested by two laser displacement sensors measurement system. The actual value of sputtering depth was obtained by adding the depth measurement curve of sputtering surface and the reference plane curve, and the actual depth result is in line with Dektak8-type surface profilometer.

8.
Chemosphere ; 214: 791-800, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30296767

RESUMEN

BACKGROUND: Exposure to high levels of metals/metalloids may impair semen quality. Computer-aided sperm analysis (CASA) can be used for kinematic analysis of spermatozoa, which provides additional insights into sperm motion characteristics. OBJECTIVE: To explore the associations of urinary and seminal plasma metal/metalloid concentrations with CASA motion parameters and assess the degree of correspondence between the two sample types. METHODS: Eighteen metals/metalloids in seminal plasma and repeated urine samples were determined among 746 men recruited from a reproductive center. We assessed their associations with 6 CASA motion parameters [i.e., straight-line velocity (VSL), curvilinear velocity (VCL), average path velocity (VAP), linearity (LIN), straightness (STR) and amplitude head displacement (ALH)] using multivariable linear regression models. RESULTS: We found significantly inverse dose-dependent relationships between seminal plasma arsenic (As) and VSL, VCL and VAP, between seminal plasma selenium (Se) and VSL and VAP, between seminal plasma zinc (Zn) and STR and LIN, and between seminal plasma manganese (Mn) and LIN in single-metal models [all false discovery rate (FDR) adjusted P for trend < 0.05]. These dose-response relationships remained statistically significant based on multiple-metal models and restricted cubic spline functions. Metal/metalloid concentrations in urine poorly predicted the same-day seminal plasma concentrations [coefficient of determination (R2) < 0.15]. We didn't find any significant associations between urinary metal/metalloid concentrations and the CASA motion parameters. CONCLUSION: Exposure to high levels of As, Se, Mn and Zn may impair sperm motion capacity. Concentrations of metals/metalloids in spot urine samples cannot accurately predict same-day seminal plasma exposure levels.


Asunto(s)
Dimenhidrinato/química , Metaloides/orina , Análisis de Semen/métodos , Semen/química , Humanos , Masculino , Espermatozoides/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA