RESUMEN
BACKGROUND: Ileocolic intussusception is considered a pediatric emergency, with concerns for risk of significant morbidity in children with a prolonged intussusception state. Emergent therapy is standard of care, as prior studies have shown poor outcomes in patients with long delays (> 24 h) before intervention. Various factors can result in shorter delays, and there are limited studies evaluating outcomes in these patients. This study aimed to determine if there were differences in reduction success rates associated with short in-hospital time delays. OBJECTIVE: This study is to determine enema success rate and morbidity in patients with documented time delays between intussusception diagnosis and therapeutic enema. MATERIALS AND METHODS: A retrospective evaluation of pediatric patients with intussusception at a single children's hospital between 2007 and 2019 was performed. Patient's records were reviewed for time of symptom onset, radiologic diagnosis, and attempted enema. Ultrasounds and radiographs were reviewed for bowel obstruction, free peritoneal fluid, trapped fluid around the intussusceptum, and absent bowel wall perfusion. Patients were evaluated for efficacy of reduction attempt, requirement for surgical reduction, and complications including bowel resection and bowel perforation. RESULTS: There were 175 cases of ileocolic intussusception requiring enema reduction. Successful reduction occurred in 72.2% (13/18) of cases performed within 1 h of diagnosis; 74.3% (78/105) between 1 and3 h; 73.2% (30/41) between 3 and 6 h; and 81.2% (9/11) with greater than 6 h. Need for bowel resection was not associated with short delays between diagnosis and reduction attempts (p = .07). CONCLUSIONS: There was no difference in intussusception reduction efficacy or complication rate in patients with increasing time between imaging diagnosis of ileocolic intussusception and reduction attempt, including delay intervals up to 8 h.
Asunto(s)
Enfermedades del Íleon , Obstrucción Intestinal , Intususcepción , Niño , Humanos , Lactante , Intususcepción/diagnóstico por imagen , Intususcepción/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Enema/métodos , Obstrucción Intestinal/etiología , Enfermedades del Íleon/diagnóstico por imagen , Enfermedades del Íleon/terapiaRESUMEN
OBJECTIVES: We examined the association between fluid overload and major adverse kidney events in critically ill patients requiring continuous renal replacement therapy for acute kidney injury. DESIGN: Retrospective cohort study. SETTING: ICU in a tertiary medical center. PATIENTS: Four-hundred eighty-one critically ill adults requiring continuous renal replacement therapy for acute kidney injury. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Fluid overload was assessed as fluid balance from admission to continuous renal replacement therapy initiation, adjusted for body weight. Major adverse kidney events were defined as a composite of mortality, renal replacement therapy-dependence or inability to recover 50% of baseline estimated glomerular filtration rate (if not on renal replacement therapy) evaluated up to 90 days after discharge. Patients with fluid overload less than or equal to 10% were less likely to experience major adverse kidney events than those with fluid overload greater than 10% (71.6% vs 79.4%; p = 0.047). Multivariable logistic regression showed that fluid overload greater than 10% was associated with a 58% increased odds of major adverse kidney events (p = 0.046), even after adjusting for timing of continuous renal replacement therapy initiation. There was also a 2.7% increased odds of major adverse kidney events for every 1 day increase from ICU admission to continuous renal replacement therapy initiation (p = 0.024). Fluid overload greater than 10% was also found to be independently associated with an 82% increased odds of hospital mortality (p = 0.004) and 2.5 fewer ventilator-free days (p = 0.044), compared with fluid overload less than or equal to 10%. CONCLUSIONS: In critically ill patients with acute kidney injury requiring continuous renal replacement therapy, greater than 10% fluid overload was associated with higher risk of 90-day major adverse kidney events, including mortality and decreased renal recovery. Increased time between ICU admission and continuous renal replacement therapy initiation was also associated with decreased renal recovery. Fluid overload represents a potentially modifiable risk factor, independent of timing of continuous renal replacement therapy initiation, that should be further examined in interventional studies.
Asunto(s)
Terapia de Reemplazo Renal Continuo/métodos , Enfermedad Crítica/terapia , Enfermedades Renales/epidemiología , Equilibrio Hidroelectrolítico/fisiología , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/terapia , Adulto , Anciano , Comorbilidad , Femenino , Tasa de Filtración Glomerular , Humanos , Unidades de Cuidados Intensivos/organización & administración , Enfermedades Renales/prevención & control , Modelos Logísticos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Centros de Atención Terciaria/organización & administraciónRESUMEN
BACKGROUND: The objective of this study was to evaluate whether the choice of intravenous access (IVA) site affects aortic attenuation during thoracic computed tomographic angiography (T-CTA) and any associated risks with intravenous device placement. METHODS: All T-CTA exams performed between 1/1/2013 and 8/14/2015 were retrospectively reviewed to identify those performed with contrast media injection via alternative (i.e. non-antecubital) IVA (n = 1769). Using time matching, antecubital IVA exams (n = 1769) were selected as controls. For each exam, attenuation was measured in the ascending aorta. Patient and technical data was subsequently collected from all 3538 patients included in this study. Multiple linear regression was used to determine if IVA site affected attenuation. Lastly, data related to extravasations for the entire T-CTA cohort were collected and compared. RESULTS: Hand/wrist, arm, and central venous access device IVA were all equivalent to antecubital IVA in terms of attenuation (P = 0.579, P = 0.599, and P = 0.522 respectively). Forearm and intraosseous IVA had significantly higher attenuation (P = 0.010 and P = 0.002, respectively) than antecubital IVA. Right-sided IVA was associated with a small attenuation increase of 11 Hounsfield Units (P < 0.001) compared to left-sided IVA. In terms of extravasation, antecubital IVA was equivalent to hand/wrist, forearm, and upper arm IVA (P = 0.778, P = 0.060, and P = 0.090 respectively). CONCLUSIONS: Satisfactory aortic attenuation achieved with non-antecubital IVA is equivalent to attenuation achieved with antecubital IVA for T-CTA imaging. The risk of contrast media extravasation in peripheral IVA devices was relatively low, however, appropriate IVA site selection should be considered an important factor for successful administration of contrast media for future imaging studies. This prevents undue harm to patients through preventable device failures when using a peripheral IV device in areas of high flexion/range of movements undergoing pressure injection for contrast media.
Asunto(s)
Angiografía , Medios de Contraste , Humanos , Medios de Contraste/efectos adversos , Estudios de Casos y Controles , Estudios Retrospectivos , Angiografía por Tomografía Computarizada/efectos adversosRESUMEN
BACKGROUND: The objective of this study is to evaluate the safety and quality of computed tomographic angiography of the thoracic aorta (CTA-TA) exams performed using intraosseous needle intravenous access (ION-IVA) for contrast media injection (CMI). METHODS: All CTA-TA exams at the study institution performed between 1/1/2013 and 8/14/2015 were reviewed retrospectively to identify those exams which had been performed using ION-IVA (ION-exams). ION-exams were then analyzed to determine aortic attenuation and contrast-to-noise ratio (CNR). Linear regression was used to determine how injection rate and other variables affected image quality for ION-exams. Patient electronic medical records were reviewed to identify any adverse events related to CTA-TA or ION-IVA. RESULTS: 17 (â¼0.2%) of 7401 exams were ION-exams. ION-exam CMI rates varied between 2.5 and 4 ml/s. Mean attenuation was 312 HU (SD 88 HU) and mean CNR was 25 (SD 9.9). A strong positive linear association between attenuation and injection rate was found. No immediate or delayed complications related to the ION-exams, or intraosseous needle use in general, occurred. CONCLUSION: For CTA-TA, ION-IVA appears to be a safe and effective route for CMI at rates up to 4 ml/s.