RESUMEN
A sensitive full-automated micromagnetic particles (MMPs) based competitive chemiluminescent immunoassay (CLIA) was developed to detect cortisol in milk. Polyclonal antibody (pAb) with good specificity against cortisol was produced. The antigen (cortisol-OVA) was labeled with acridinium ester (cortisol-OVA-AE) as signal tracer. During the detection, the free cortisol in sample will compete with cortisol-OVA-AE for binding to pAb. To capture pAb, MMPs conjugated with goat anti-rabbit IgG was added. The whole immunoassay process (exclude sample pretreatment) was performed by automatic chemiluminescence immunoassay instrument, which could consume less test time (within 40â¯min) and avoid error from manual operation. The method showed a good detection limit of 0.12â¯ng/mL, a broad linear range from 0.42 to 72.27â¯ng/mL for cortisol detection, negligible cross-reactivity with related analogues and satisfied recovery (84.3%-102.3%) for spiked milk samples test. Simultaneously, since the results of proposed method had no significant difference with those of LC-MS/MS, the proposed method was confirmed to have a potential applicability for rapidly monitoring cortisol in the food.