Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Vox Sang ; 114(5): 487-494, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31056755

RESUMEN

BACKGROUND AND OBJECTIVES: The 30-min rule has been used to maintain a core temperature (CT) of red-blood-cell (RBC) units below 10°C during transportation. We evaluated the utility of temperature-sensitive indicators (TIs) to monitor the surface temperature (ST) of RBC units and to explore whether TIs can help with compliance with the 30-min rule by extrapolating or correlating temperature change with time. MATERIALS AND METHODS: Two US FDA-approved TIs, Safe-T-Vue 10 (STV10; Temptime Corporation, Morris Plains, NJ, USA) and Timestrip Blood Temp 10 (BT10; Timestrip UK Ltd, Cambridge, UK), were attached to 50 RBC units. After issue, their colour change indicating 10°C was monitored, and temperature excursions were measured by standard reading. In additional 18 RBC units, both ST and CT were monitored simultaneously. RESULTS: In 50 RBC units, 94% of STV10 and 100% of BT10 showed colour change indicating 10°C within 30 min; 4% of STV10 and 18% of BT10 showed it during transportation. The time for colour change indicating 10°C differed significantly between STV10 and BT10 (19·0 vs. 5·6 min, P < 0·001). In additional 18 RBC units, 83·3% of STV10, 100% of BT10 and 88·9% of CT reached 10°C within 30 min, and the time for colour change indicating 10°C was 24·4 min in STV10, 14·6 min in BT 10 and 24·2 min in CT (P < 0·001). CONCLUSION: In two TIs, the time for colour change indicating 10°C varied considerably. To enhance the utility of TIs, further improvement and standardization would be needed.


Asunto(s)
Conservación de la Sangre/normas , Eritrocitos , Temperatura , Conservación de la Sangre/métodos , Humanos , Indicadores y Reactivos
2.
Clin Biochem ; 113: 59-63, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36627012

RESUMEN

BACKGROUND: There is an increased need for the sensitive and accurate measurement of estradiol levels in patients with estradiol-related endocrine disorders. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a reliable and accurate method for measuring steroid hormone levels. Here, we aimed to establish an LC-MS/MS-based method to quantify estradiol levels without sample derivatization and evaluated its analytical performance. METHODS: Sciex Triple Quad 6500 + LC-MS/MS was used for estradiol analysis. We evaluated its analytical performance, including linearity, precision, the lower limit of detection and quantification (LoD and LoQ, respectively), accuracy, and carryover. The estradiol results determined by LC-MS/MS were compared with those obtained using a chemiluminescent microparticle immunoassay. RESULTS: The LC-MS/MS output was linear for serum estradiol concentrations in the range of 0.2-10311.6 pmol/L. The intra-laboratory precision (coefficient of variation) was 3.0-10.1 %. The LoD and LoQ were 2.8 and 7.5 pmol/L, respectively. The overall accuracy was within 15 % of bias, and the carryover was within the acceptable range (<1.0 %). The results of the estradiol analysis determined by LC-MS/MS were comparable to those obtained by the chemiluminescent microparticle immunoassay (r2 = 0.9843), although there was a negative bias of - 17.82 (95 % confidence interval, -27.21 to - 8.44). CONCLUSIONS: A highly sensitive, derivatization-free LC-MS/MS method was successfully developed in this study. This may be beneficial for estradiol measurements in patients with estradiol-related endocrine disorders.


Asunto(s)
Estradiol , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Técnicas para Inmunoenzimas , Reproducibilidad de los Resultados
3.
Clin Biochem ; 113: 52-58, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36627011

RESUMEN

BACKGROUND: Ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) is a reliable and accurate method for measuring steroid hormone levels. There is an increasing need for sensitive and precise methods to measure estradiol in pediatric patients. Here, we established reference intervals for estradiol in healthy children using a UHPLC-MS/MS-based method for the first time in South Korea. METHODS: Serum estradiol was measured using a Sciex Triple QuadTM 6500 + UHPLC-MS/MS (Sciex, Framingham, MA, USA). Reference intervals for estradiol were established according to the CLSI document EP28-A3c:2008. The reference intervals were validated using serum samples from 634 pediatric patients, including neonates, children, and adolescents. Among them, 389 specimens were used in analysis of the specimen acceptance time. Statistical analysis was performed using MedCalc (MedCalc, Ostend, Belgium) and Analyse-it (Analyse-it Software Ltd., Leeds, United Kingdom) software. RESULTS: Reference intervals for boys (n = 297) were <16.6, <7.3, <19.0, <30.5, 7.6-96.5, and 10.6-134.4 pmol/L among those aged <1, 1-5, 6-9, 10-11, 12-14, and 15-17 years, respectively. Reference intervals for girls (n = 337) were <114.7, <24.2, <34.8, 8.0-177.0, 10.4-480.5, and 9.1-486.7 pmol/L among those aged <1, 1-5, 6-9, 10-11, 12-14, and 15-17 years, respectively. Overall, there was no effect of specimen acceptance time on estradiol measurements in boys or girls, except for that in the group aged 10-11 years. CONCLUSIONS: The reference intervals for healthy children were validated using a UHPLC-MS/MS-based method. The highly analytical sensitive UHPLC-MS/MS method may be useful for estradiol determination in pediatric patients.


Asunto(s)
Estradiol , Espectrometría de Masas en Tándem , Masculino , Femenino , Adolescente , Recién Nacido , Humanos , Niño , Cromatografía Líquida de Alta Presión , Espectrometría de Masas en Tándem/métodos , Valores de Referencia , Programas Informáticos
4.
Ann Lab Med ; 43(1): 19-28, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36045053

RESUMEN

Background: Mass spectrometry methods exhibit higher accuracy and lower variability than immunoassays at low testosterone concentrations. We developed and validated an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantifying serum total testosterone. Methods: We used an ExionLC UPLC (Sciex, Framingham, MA, USA) system and a Sciex Triple Quad 6500+ (Sciex) MS/MS system in electrospray ionization and positive ion modes with multiple reaction monitoring transitions to evaluate precision, accuracy, linearity, lower limit of quantitation (LLOQ), carryover, ion suppression, stability, and reference intervals. For method comparison, we measured serum testosterone concentrations using this method in 40 subjects whose testosterone concentrations ranged from 0.14 to 55.48 nmol/L as determined using the Architect i2000 immunoassay (Abbott Diagnostics, Abbott Park, IL, USA) and in an additional 160 sera with testosterone concentrations <1.67 nmol/L. Results: The intra- and inter-run precision CVs were <2.81%, and the accuracy bias values were <3.85%, which were all acceptable. The verified linear interval was 0.03-180.84 nmol/L; the LLOQ was 0.03 nmol/L. No significant carryover and ion suppression were observed. The testosterone in serum was stable at 4°C, at -20°C, and after three freeze-thaw cycles. The reference intervals were successfully verified. The correlation was good at testosterone concentrations of 0.14-55.48 nmol/L; however, the Architect assay showed positive percent bias at concentrations <1.67 nmol/L. Conclusions: The UPLC-MS/MS assay shows acceptable performance, with a lower LLOQ than the immunoassay. This method will enable the quantitation of low testosterone concentrations.


Asunto(s)
Espectrometría de Masas en Tándem , Testosterona , Cromatografía Liquida/métodos , Humanos , Inmunoensayo/métodos , Valores de Referencia , Reproducibilidad de los Resultados
5.
Ann Lab Med ; 41(1): 60-67, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32829580

RESUMEN

BACKGROUND: Neutrophil gelatinase-associated lipocalin (NGAL) is a useful biomarker for acute kidney injury (AKI) prediction. However, studies on whether using both plasma NGAL (PNGAL) and urine NGAL (UNGAL) can improve AKI prediction are limited. We investigated the best approach to predict AKI in high-risk patients when using PNGAL and UNGAL together. METHODS: We enrolled 151 AKI suspected patients with one or more AKI risk factors. We assessed the diagnostic performance of PNGAL and UNGAL for predicting AKI according to chronic kidney disease (CKD) status by determining the areas under the receiver operating curve (AuROC). Independent predictors of AKI were assessed using univariate and multivariate logistic regression analyses. RESULTS: In the multivariate logistic regression analysis for all patients (N=151), Model 2 and 3, including PNGAL (P=0.012) with initial serum creatinine (S-Cr), showed a better AKI prediction power (R2=0.435, both) than Model 0, including S-Cr only (R2=0.390). In the non-CKD group (N=135), the AuROC of PNGAL for AKI prediction was larger than that of UNGAL (0.79 vs 0.66, P=0.010), whereas in the CKD group (N=16), the opposite was true (0.94 vs 0.76, P=0.049). CONCLUSIONS: PNGAL may serve as a useful biomarker for AKI prediction in high-risk patients. However, UNGAL predicted AKI better than PNGAL in CKD patients. Our findings provide guidance for selecting appropriate specimens for NGAL testing according to the presence of CKD in AKI high-risk patients.


Asunto(s)
Lesión Renal Aguda/diagnóstico , Biomarcadores/sangre , Lipocalina 2/sangre , Anciano , Área Bajo la Curva , Biomarcadores/orina , Creatinina/sangre , Femenino , Tasa de Filtración Glomerular , Humanos , Lipocalina 2/orina , Modelos Logísticos , Masculino , Persona de Mediana Edad , Curva ROC , Factores de Riesgo
6.
Ann Lab Med ; 38(3): 204-211, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29401554

RESUMEN

BACKGROUND: The prognostic utility of cardiac biomarkers, high-sensitivity cardiac troponin I (hs-cTnI) and soluble suppression of tumorigenicity-2 (sST2), in non-cardiac surgery is not well-defined. We evaluated hs-cTnI and sST2 as predictors of 30-day major adverse cardiac events (MACE) in patients admitted to the surgical intensive care unit (SICU) following major non-cardiac surgery. METHODS: hs-cTnI and sST2 concentrations were measured in 175 SICU patients immediately following surgery and for three days postoperatively. The results were analyzed in relation to 30-day MACE and were compared with the revised Goldman cardiac risk index (RCRI) score. RESULTS: Overall, 30-day MACE was observed in 16 (9.1%) patients. hs-cTnI and sST2 concentrations differed significantly between the two groups with and without 30-day MACE (P<0.05). The maximum concentration of sST2 was an independent predictor of 30-day MACE (odds ratio=1.016, P=0.008). The optimal cut-off values of hs-cTnI and sST2 for predicting 30-day MACE were 53.0 ng/L and 182.5 ng/mL, respectively. A combination of hs-cTnI and sST2 predicted 30-day MACE better than the RCRI score. Moreover, 30-day MACE was observed more frequently with increasing numbers of above-optimal cut-off hs-cTnI and sST2 values (P<0.0001). Reclassification analyses indicated that the addition of biomarkers to RCRI scores improved the prediction of 30-day MACE. CONCLUSIONS: This study demonstrates the utility of hs-cTnI and sST2 in predicting 30-day MACE following non-cardiac surgery. Cardiac biomarkers would provide enhanced risk stratification in addition to clinical RCRI scores for patients undergoing major non-cardiac surgery.


Asunto(s)
Cardiopatías/diagnóstico , Proteína 1 Similar al Receptor de Interleucina-1/análisis , Troponina I/análisis , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Biomarcadores/análisis , Electrocardiografía , Ensayo de Inmunoadsorción Enzimática , Femenino , Cardiopatías/patología , Humanos , Unidades de Cuidados Intensivos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Periodo Posoperatorio , Pronóstico , Estudios Prospectivos , Curva ROC
7.
PLoS One ; 13(1): e0191486, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29364941

RESUMEN

OBJECTIVE: Presepsin is a novel biomarker to diagnose sepsis but its prognostic value has not been comprehensively reviewed. We conducted this meta-analysis to evaluate the mortality prediction value of presepsin in sepsis. METHODS: We searched comprehensive electronic databases from PubMed, EMBASE, and Cochrane Library through September 2017 using the key words of ('presepsin' or 'sCD14-ST' or 'soluble CD14 subtype') and ('sepsis' or 'septic shock') and ('prognosis' or 'prognostic value' or 'prognostic biomarker' or 'mortality'). We extracted the presepsin levels in survivors and non-survivors from each individual study and evaluated the standardized mean difference (SMD) using a web-based meta-analysis with the R statistical analysis program. RESULTS: A total of 10 studies and 1617 patients were included. Presepsin levels in the first sampling (within 24 hours) were significantly lower among survivors as compared with non-survivors: the pooled SMD between survivors and non-survivors was 0.92 (95% CI: 0.62-1.22) in the random effects model (I2 = 79%, P< 0.01). In subgroups, divided by the sepsis severity or study site, pooled SMD was consistently noting higher presepsin levels in non-survivals (P< 0.05). CONCLUSION: This meta-analysis demonstrates some mortality prediction value in presepsin in patients with sepsis. Further studies are needed to define the optimal cut-off point to predict mortality in sepsis.


Asunto(s)
Receptores de Lipopolisacáridos/metabolismo , Fragmentos de Péptidos/metabolismo , Sepsis/metabolismo , Humanos , Pronóstico , Sepsis/patología
8.
Clin Biochem ; 55: 75-79, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29608892

RESUMEN

OBJECTIVES: The diagnostic tests for autoimmune disease include screening for autoantibodies for nuclear antigens (ANA) and antibodies against extractable nuclear antigens (ENA). Using the line immunoassay (LIA) method, various kinds of ENA antibodies can be detected simultaneously. We evaluated the performance of the newly launched LIA-ANA-Profile-17S (Shenzhen YHLO Biotech, Shenzhen, China) as compared to a conventional LIA kit. METHODS: Residual samples were collected from 200 patients who had been tested for ANA using indirect immunofluorescence. The LIA-ANA-Profile-17S was compared to the EuroLine ANA (Euroimmun, Oberlausitz, Germany) for the analysis of 17 different autoantibodies. The concordance rate and agreement between assays were determined. Samples showing discrepancies between the LIA-ANA-Profile-17S and EuroLine tests were further examined through additional analysis. RESULTS: The overall agreement was moderate (kappa = 0.759, 95% CI = 0.712-0.805). Agreement between assays ranged from weak to almost perfect, except for those tests targeting nucleosomes, histones, and PM-Scl. Of the 57 disparate results between LIA-ANA-Profile-17S and EuroLine, 38 (66.7%) samples tested positive under an additional assay, showing variable patterns between types of autoantibodies. The positive rate of each autoantibody between LIA-ANA-Profile-17S and EuroLine did not differ significantly, except for anti-nucleosome and anti-histone assays in samples from patients diagnosed with systemic lupus erythematosus (P = 0.004 and 0.001, respectively). CONCLUSIONS: Compared to those from the conventional EuroLine assay, the LIA-ANA-Profile-17S results showed variable agreement in samples showing different prevalence of each autoantibody. The most frequently detected antibodies showed almost perfect agreement. The LIA-ANA-Profile-17S could play a role in the diagnosis of systemic autoimmune disease in ANA-positive samples.


Asunto(s)
Anticuerpos Antinucleares/sangre , Enfermedades Autoinmunes/sangre , Adulto , Femenino , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA